BLOWER DOOR TESu FORM
MOUSe Infiltration Test Cerdilea-iGion
Prescriptive and Perf rimaliCe Methae
Date: Permit #:
Contractor:
®b Address: =S o x8 Tree fi� d Tr i I F t P. e,e, FL
Construction: New Construction — Complete
EKiSGii'>sg—After Addi�i®n
House Infiltration Test Results SLC Clirnate Zone 2
CFM (50) = l I i Test Date: B 1 LJ
Volume = I S_ 1 �) S 1
ACH (50) = CFM (50) x 60 / VoIume = '3 - � Mechanical Ventilation required less than 3 AA CN
Passing results must be & ACH (50) or less V Bass ( ) Fall
FGC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
Fac, Residential
Where the air infiltration rate of a dwelling unit is less than 13 -air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Cornpanv
P
Company Name: Pro -Duct SerVICeS Address: '1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certih/ that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with ectio 402.4.1.2 Climate %one 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 6061633
BUILDING PERFORMANCE INSTITUTE, INC.
107 Hermes Road, Suite 210
Malta, NY 12020 5 rt
(877) 274-1274"
www.bpi.org
y{yy, r
ED.BPI
Klein
BPI ID#: 5061633
5M (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES)
CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE
Infiltration & Duct leakage (IDL) 4/262021
BUILDING PERFORMANCE INSTITUTE, INC.