HomeMy WebLinkAboutREVISION,ENERGY CALCS, 6.15.20Prepared By; Ace Air Conditioning Jimmy Evans FORMS HVAC/Meohanlcal License: CAC1813633 FLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach FORM R402-2017 Climate Zone m Scope: Compliance with Section 6401.2(1) of the Florida Building Code, Energy Conservation, shall be demonstrated by the use of Form R402 for single- and multiple -family residences of three stories or less in height, additions to existing residential buildings, alterations, renovations and building systems in existing buildings, as applicable. To comply, a building must meet or exceed all of the energy efficiency requirements on Table R402A and all applicable mandatory requirements summarized in Table R4028 of this form. If a building does not comply with this method, or by the UA Alternative method, it may still comply under Section 8405 of the Florida Building Code, Energy Conservation. PROJECTNAME 5701 Sunset Blvd. BUILDER: ANDADDRESS:5701 Sunset Blvd. OWNER: Joseph Mammano PERMITTING OFFICE: JURISDICTION NUMBER: PERMIT NUMBER: General Instructions: I. Fill in all the applicable spaces of the "To Be Installed" column on Table R402A with the Information requested. All "To Be Installed" values must be equal to or more efficient than the required levels. 2. Complete page 1 based on the "To Be Installed" column Information. 3. Read the requirements of Table R402B and check each box to indicate your intent to comply with all applicable items. 4. Read, sign and date the "Prepared By" certification statement at the bottom of page 1. The owner or owner's agent must also sign and date the form 1. New construction, addition, or existing building 1. Addit ion 2. Single-family detached or multiple -family attached 2. 3. If multiple -family, number of units covered by this submission 3. 4. Is this a worst case? (yeslno) 4, No S. Conditioned floor area (sq. ft.) 5. 308 6. Windows, type and area a) U -factor: 6a. .34 b) Solar Heat Gain Coefficient (SHGC) 6b. .23 c) Area 6c. 25 _ 7. Skylights a) U -factor: 7a. b) Solar Heat Gain Coefficient (SHGC) 7b. 8. Floor type, area or perimeter, and insulation: a) Slab -on -grade (13 -value) Sa. 308 b) Wood, raised (R -value) ab. c) Wood, common (R -value) ac. d) Concrete, raised (R -value) 8d. e) Concrete, common (R -value) 8e. 9. Wali type and insulation: a) Exterior: i. Wood frame (Insulation R -value) 13 9a1. 2. Masonry (Insulation R -value) 9a2. b) Adjacent: 1. Wood frame (Insulation R -value) 9b1. 2. Masonry (Insulation R -value) 9b2. 10. Cell Ing type and insulation a) Attic(insulation R -value) 10a. R-38 b) Single assembly (Insulation R -value) lob. 11. Air distribution system: a) Duct location, insulation AttiCr R-8 Ila. b) AHU location iib. Existing/ Interior c) Total duct leakage. Test report attached. 11c. cfmlloo s.f. Yes 0 No ❑ 12. Cooling system: a) type 12a. Existing b) efliciency 12b. Existing 13. Heating system: a)type 138. Existing b) efficiency 13b. EXiSting 14. HVAC sizing calculation: attached 14. Yes IN No 11 15. Water heating system: a) type 15a. Exist ing b) efficiency 15b. I hereby certify that the plans and specifications covered by this form are Review of plans and specifications covered by this form indicate In compliance with the Florida Building Code, Energy Conservation. compliance with the Florida Building Code, Energy Conservation, Before PREPARED BY: JiMmy Evans Date -10-21-19 construction is.complete, this building will be inspected for compliance In hereby certify that this building Is In compliance with the Florida Building accordance with Section 553.908, F.S. Code, Energy Conservation. CODE OFFICIAL: OWNERIAGENT: Date: Date: FLORIDA BUILDING CODE - ENERGY CONSERVATION, 6th EDITION (2017) R-55 Prepared By; Ace Air Conditioning Jimmy Evans FORMS HVAC/Meohanlcal License: CAC1813633 FLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach FORM R402-2017 Climate Zone m Scope: Compliance with Section 6401.2(1) of the Florida Building Code, Energy Conservation, shall be demonstrated by the use of Form R402 for single- and multiple -family residences of three stories or less in height, additions to existing residential buildings, alterations, renovations and building systems in existing buildings, as applicable. To comply, a building must meet or exceed all of the energy efficiency requirements on Table R402A and all applicable mandatory requirements summarized in Table R4028 of this form. If a building does not comply with this method, or by the UA Alternative method, it may still comply under Section 8405 of the Florida Building Code, Energy Conservation. PROJECTNAME 5701 Sunset Blvd. BUILDER: ANDADDRESS:5701 Sunset Blvd. OWNER: Joseph Mammano PERMITTING OFFICE: JURISDICTION NUMBER: PERMIT NUMBER: General Instructions: I. Fill in all the applicable spaces of the "To Be Installed" column on Table R402A with the Information requested. All "To Be Installed" values must be equal to or more efficient than the required levels. 2. Complete page 1 based on the "To Be Installed" column Information. 3. Read the requirements of Table R402B and check each box to indicate your intent to comply with all applicable items. 4. Read, sign and date the "Prepared By" certification statement at the bottom of page 1. The owner or owner's agent must also sign and date the form 1. New construction, addition, or existing building 1. Addit ion 2. Single-family detached or multiple -family attached 2. 3. If multiple -family, number of units covered by this submission 3. 4. Is this a worst case? (yeslno) 4, No S. Conditioned floor area (sq. ft.) 5. 308 6. Windows, type and area a) U -factor: 6a. .34 b) Solar Heat Gain Coefficient (SHGC) 6b. .23 c) Area 6c. 25 _ 7. Skylights a) U -factor: 7a. b) Solar Heat Gain Coefficient (SHGC) 7b. 8. Floor type, area or perimeter, and insulation: a) Slab -on -grade (13 -value) Sa. 308 b) Wood, raised (R -value) ab. c) Wood, common (R -value) ac. d) Concrete, raised (R -value) 8d. e) Concrete, common (R -value) 8e. 9. Wali type and insulation: a) Exterior: i. Wood frame (Insulation R -value) 13 9a1. 2. Masonry (Insulation R -value) 9a2. b) Adjacent: 1. Wood frame (Insulation R -value) 9b1. 2. Masonry (Insulation R -value) 9b2. 10. Cell Ing type and insulation a) Attic(insulation R -value) 10a. R-38 b) Single assembly (Insulation R -value) lob. 11. Air distribution system: a) Duct location, insulation AttiCr R-8 Ila. b) AHU location iib. Existing/ Interior c) Total duct leakage. Test report attached. 11c. cfmlloo s.f. Yes 0 No ❑ 12. Cooling system: a) type 12a. Existing b) efliciency 12b. Existing 13. Heating system: a)type 138. Existing b) efficiency 13b. EXiSting 14. HVAC sizing calculation: attached 14. Yes IN No 11 15. Water heating system: a) type 15a. Exist ing b) efficiency 15b. I hereby certify that the plans and specifications covered by this form are Review of plans and specifications covered by this form indicate In compliance with the Florida Building Code, Energy Conservation. compliance with the Florida Building Code, Energy Conservation, Before PREPARED BY: JiMmy Evans Date -10-21-19 construction is.complete, this building will be inspected for compliance In hereby certify that this building Is In compliance with the Florida Building accordance with Section 553.908, F.S. Code, Energy Conservation. CODE OFFICIAL: OWNERIAGENT: Date: Date: FLORIDA BUILDING CODE - ENERGY CONSERVATION, 6th EDITION (2017) R-55 I FORMS TABLE R402A BUILDING COMPONENT PRESCRIPTIVE REQUIREMENTS' INSTALLED VALUES Climate Zone 1 Climate Zone 2 Windows U -Factor = NR U -Factor = 0.401 U -Factor = . 3 4 SHGC = 0.25 SHGC = 0-25 SHGC = - 2 3 Skylights U -factor = 0.75 U -factor = 0.65 U -factor = SHGC = 0.30 SHGC = 0.30 SHGC = Doors: Exterior door U -factor - NR U -factor = 0.401 U -factor= Floors: Slab -on -Grade NR NR Over unconditioned spaces° R-13 R-13 R -Value - NR Walls": Ext. and Adj. Frame R-13 R-13 R -Value = 13 Mass Insulation on wall interior R-4 R-6 R -Value = Insulation on wall exterior R-3 R-4 R -Value = Ceilings' R-30 R=38 R -Value = Air infiltration Blower door lest is required on the building envelope to verify leakage < 1 ACH; Total leakage = ACH test report provided to code official. Test re ori attached? Yes No Air distribution systems: Air handling unit Not allowed in attic Duct R -value R -value >_ R-8 (supply in attics) or >_ R-6 (all other duct locations) LocR-Vation:At tic Location: At = $ Air leakages: Duct lest Postconstruction test Total Ieakage <_ 4 cfm1100 s.f. Hough -in test Total leakage <_ 4 cfm1100 s.f. (air handler installed) Total leakage = cfm/100s.f. Total leakage <_ 3 cfmli 00 s.f. (air handler not installed) Test report Attached? Yes ® No D Ducts in conditioned space Test not required if all ducts and AHU are in conditioned space Location: Air conditioning system: Minimum federal standard required by NAEW: Central system <_ 65,000 Bluth SEER 14.0 Room unit or PTAC EER [from Table C403.2.3(3)] SEER= Existing Other: See Tables C403.2.3(1)-(11) EER - Heating system: Minimum federal standard required by NAECA6: Heat pump <_ 65,000 Bluth HSPF 8.2 HSpF - Gas furnace, non -weatherized AFUE80% AFUE= Existing Oil furnace, non -weatherized AFUE 83% AFUE = Other: Water heating system (storage type): Minimum federal standard required by NAECA6: Electric' 40 gal: EF = 0.92 Gallons = 50 gal: EF = 0.90 EF= Existing Gas fired' 40 gal: EF = 0.59 Gallons = 50 gal: EF = 0.58 EF = Other (describe): NR = No requirement. (1) Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using this method. (2) For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code, Residential or Section 1609.1.2 of the Florida Building Code, Building, the maximum U -factor shall be 0.65 in Climate Zone 2. An area -weighted average of U -factor and SHGC shall be accepted to meet the requirements, or up to 15 square feet of glazed fenestration area are exempted from the U -factor and SHGC requirement based on Sections 8402.3.1, R402.3.2 and R402.3.3. (3) One side -hinged opaque door assembly up to 24 square feet is exempted from this U -factor requirement. (4) R -values are for insulation material only as applied in accordance with manufacturer's installation instructions. For mass walls, the "interior of wall" requirement must be met except if at least 50 percent of the insulation required for the "exterior of wall" is installed exterior of, or integral to, the wall. (5) Duels & AHU installed "substantially leak free" per Section R403.3.2. Test required by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. (6) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1957 for typical residential equipment and are subject to NAECA rules and regulations. For other types of equipment, see Tables C403.2.3(1-11) of the Commercial Provisions of the Florida Building Code, Energy Conservation. (7) For other electric storage volumes, minimum EF = 0.97 - (0.00132 * volume). (8) For other natural gas storage volumes, minimum EF = 0.67 - (0.0019 * volume). Prepared By; Ace Air Conditioning ilimrny Evans VACiMechaf t:al License. XNE 3 F R-56 FLORIDA BUILDING CODE— ENERGYON, 6th EDITION (2017) FORMS TABLE R402B MANDATORY REQUIREMENTS Component Section Summary of Requirements) Check Air leakage R402.4 To be caulked, gasketed, weatherstripped or otherwise sealed per Table R402.4.1.1, Recessed lighting: IC -rated as having <_ 2.0 cim tested to ASTM E 283. Windows and doors: 0.3 cfmisq. ft. (swinging doors: 0.5 cfm/sf) when tested to NFRC 400 or AAMA(WDMAICSA 1011I.S. 2/A440, Fireplaces: Tight-fitfing flue dampers & outdoor combustion air. Programmable 8403.1.2 A programmable thermostat is required for the primary heating or cooling system. thermostat 8403.3.2 Ducts shall be tested as per Section 8403.3.2 by either individuals as defined in Section 553.993 5 () or (7 Florida ) Air distribution system 8403.3.4 , Statutes, or individuals licensed as set forth in Section 489.105(3)1 , or i ,Florida Statutes. Air handling units (1), ) (g).) ( are not allowed in attics. Water heaters R403.5 Comply with efficiencies in Table C404.2. Hot water pipes insulated to > R-3 to kitchen outlets, other cases. Circulating systems to have an automatic or accessible manual OFF switch. Heal trap required for vertical pipe risers. Swimming pools & spas R403.10 Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heal loss except if 70% of heat from site -recovered energy. Off/timer switch required, Gas heaters minimum thermal efficiency is 82%. Heat pump pool heaters minimum COP is 4.0. Cooling/heating R403.7 Sizing calculation performed & attached. Special occasion cooling or heating capacity requires separate system or equipment variable capacity system. Lighting equipment 8404.1 At least 75% of permanently installed lighting fixtures shall be high -efficacy lamps. Prepared By: Ace Air Conditioning Jimmy Evans HVAC/Mechanical License: ICAC 18113533 FLORIDA BUILDING CODE — ENERGY CONSERVATION, 6th EDITION (2017) U ' V R-57 Building Analysis Entire House W." Ace Air Conditioning Job: 5741 Sunset Blvd. Date: By: Jimmy Evans 2985 Enterprise Rd., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533 For: Detailed Enterprises 5701 Sunset Blvd., Ft. Pierce, FL 34982 Healr� Component R -sign Tdhditiohs:�:� Btuh % of load Walls Location: 3015 Indoor: Heating Cooling Orlando Intl AP, FL, US 10.1 Indoor temperature (°F) 70 75 Elevation: 105 ft Ceilings Design TD (°F) 28 17 Latitude: 28°N 3.3 Relative humidlty N 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 1.3 46.6 Dry bulb (°F) 42 92 Infiltration: 0 Daily range (°F) - 17 (M) Method Simplified 0 Wet bulb (°F - 76 Construction quality Average Adjustments Wind speed (mph) 15.0 7.5 Fireplaces 0 Healr� Component Btuhlft2 Btuh % of load Walls 2.4 3015 16.0 Glazing 13.2 1904 10.1 Doors 11.0 422 2.2 Ceilings 1.3 1587 8.4 Floors 3.3 4155 22.1 Infiltration 1.9 2325 12.3 Ducts 5425 28.8 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 18833 100.0 Floors .......... ... � OEC, ..... ,.......... Component Btuh/ft' Btuh % of load Walls 1.9 2427 9.5 Glazing 51.9 7481 29.2 Doors 11.9 458 1.8 Ceilings 2.4 3047 11.9 Floors 0 0 0 Infiltration 0.6 736 2.9 Ducts. 7092 27.7 Ventilation 0 0 Internal gains 4390 17.1 Blower 0 0 Adjustments 0 Total 25630 100.0 Latent Cooling Load = 3513 Btuh Overall U -value = 0.099 Btuh/ft2-°F Data entries checked. Wrights sift _ w Right -Suite® Universal 2018 18.0.16 RBU00268 ...tions\Detailed Enterprise615701 Sunset Blvd. rup Calc = MJ8 Front Door faces: Gains Other Ceilings Infiltration - prepared By: Ace Air Con Conditioning _ Jimmy Evans HVACIMechanicai License: CAC 1813533 2019 -Oct -21 16:46:25 Page 1 Partitions 12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c. - • • • • 13.0 2.56 Location: 1.42 Indoor: Heating Cooling Orlando Intl AP, FL, US Indoor temperature (°F) 70 75 Elevation: 105 ft Windows Design TD (°F) 28 17 Latitude: 28ON Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 1.3 46.6 Dry bulb (°F) 42 92 Infiltration: Daily range (°F) - 17 ( M) Method Simplified Wet bulb (OF) - 76 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 19 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain 229 Ceilings R, BtuhlR' °F W -Tl tuh MOM Bluh MOW Btu Walls 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112' 12E-Osw: Frm wail, stucco ext, 112" wood shth, r-19 cav ins, 1/2" s 120 0.068 19.0 1.91 229 1.45 174 gypsum board int fns h, 2"x6" wood frm, 16" o.c. stud w 109 0.068 19.0 1.91 209 1.45 159 all 229 0.068 19.0 1.91 438 1.45 333 Partitions 12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c. 73 0.091 13.0 2.56 186 1.42 103 stud Windows 4A4-2ov: 2 glazing, cir outr, argon gas, vnl frm mat, clr low -e innr, 114" w 23 0.470 0 13.2 299 49.3 1118 gap, 114" thk; 1.5 ft overhang (4 ft window ht, 1 ft sep.); 6.67 ft head ht Doors 11 DO: Door, wd s type n 19 0.390 0 11.0 211 11.9 229 Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112' 233 0.032 30.0 0.90 209 1.73 401 gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 32 0.989 0 27.8 875 0 0 Prepared By: CW Ace Air Conditioning Jimmy Evans HVACIMechanical License: CAC1813533 wrightsoft, 2019 -Oct -21 16:46:25 ­­ •, • _,... , Right -Suite® Universal 2018 18.0.16 RSU00268 Page 1 ...tions\Detailed EnterpriseM5701 Sunset Blvd.rup Calc = M48 Front Door faces: E Component Constructions Job: 5701 Sunset Blvd. W1C Date: By: Jimmy Evans "Vt*v" Ace Air Conditioning 2985 Enterprise RCS., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7756 Email: jevans@aceac.com Web: www.aceac.com License: CAc18i3533 For: Detailed Enterprises 5701 Sunset Blvd., Ft. Pierce, FL 34982 jijijjlj 30.0 0.90 30 1.73 57 Location: 0 Indoor: Heating Cooling Orlando Intl AP, FL, US Indoor temperature (°F) 70 75 Elevation: 105 ft Design TD (°F) 28 17 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 1.3 46.6 Dry bulb (°F) 42 92 Infiltration: Daily range (°F) - 17 ( M) Method Simplified Wet bulb (°F) - 76 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Instal R Htg HTM Loss ctg HTM Gain 8l Btuhlft'-°F Il' °FlBtuh Btuh/t` Btu Btuhm2 81uh Walls 12E-Osw: Fmn wall, stucco ext, 1/2" wood shth, r-19 cav ins, 112" n 44 0.068 19.0 1.91 84 1.45 64 gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud w 48 0.068 19.0 1.91 92 1.45 70 all 92 0.068 19.0 1.91 176 1.45 134 Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 33 0.032 30.0 0.90 30 1.73 57 12 0.989 0 27.8 320 0 ' 0 WePrepared Bn Ace Air Conditioning Jimmy Evans HVAC/Mechanical License: CAC1813533 wr'ightsofts 20#9 -Oct -2116:46:25 ,OCk«u,rw^,r.,.•n.. ,w,«,, Right -Suite® Universal 2018 18.0.16 RS000268 Page 2 ...tionslDelailed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E Component Constructions Job: 5701 Sunset Blvd. Date: Bath By: Jimmy Evans wo Ace Air Conditioning 2985 Enterprise Rd., Debary, FL 32713 phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533 • a tin ptis For: Detailed Enterprises 5701 Sunset Blvd., Ft. Pierce, FL 34982 Partitions (none) Windows (none) Boors (none) Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73 gypsum board intfnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0 Prepared By: EWAce Ce Air Air Conditioning Jimmy Evans HVAC/Mechanical License: CAC1813533 67 0 -d- Wriightsaft" 2019-00-21 16:46:25 leCk­. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3 ...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E - r e e • Location: Indoor: Heating Cooling Orlando Intl AP, FL, US Indoor temperature (°F) 70 75 Elevation: 105 ft Design TD (°F) 28 17 Latitude: 280N Relative humidity {%} 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 1.3 46.6 Dry bulb {°F} 42 92 Infiltration: Daily range (°F) - 17 (M) Method Simplified Wet bulb (°F) - 76 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area lJ-value Insui R Htg HTM Loss Cig HTM Gain ft, Bluhlft-r ftx-°F13Iuh Bluhlft' Bluh BluhM' Btu Walls 12E-Osw: Frm wall, stucco ext, 112" wood shth, r-19 cav ins, 112" n 52 0.068 19.0 1.91 99 1.45 75 gypsum board i nt fnsh, 2'W" wood frm, 16" o.c. stud Partitions (none) Windows (none) Boors (none) Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73 gypsum board intfnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0 Prepared By: EWAce Ce Air Air Conditioning Jimmy Evans HVAC/Mechanical License: CAC1813533 67 0 -d- Wriightsaft" 2019-00-21 16:46:25 leCk­. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3 ...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E Sheet 1 Job #: 5701 Sunset Bivd. Performed by Jimmy Evans for: Detailed Enterprises 5701 Sunset Blvd. Ft. Pierce, FL 34982 Ace Air Conditioning 2985 Enterprise Rd. Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7758 www.aceae.com jevans@aceac.com 0'.M WePrepared By: Ace Air Conditioning Jimmy Evans HVAC/Mechanical Li CAC1813533 Scale: 1 :136 Page 1 Right-Suite®Universal 2018 18.0.16 RSU00268 2019 -Oct -21 16:46:27 ...Enterprises15701 Sunset Blvd.rup I FORMS TABLE R402A BUILDING COMPONENT PRESCRIPTIVE REQUIREMENTS' INSTALLED VALUES Climate Zone 1 Climate Zone 2 Windows U -Factor = NR U -Factor = 0.401 U -Factor = . 3 4 SHGC = 0.25 SHGC = 0-25 SHGC = - 2 3 Skylights U -factor = 0.75 U -factor = 0.65 U -factor = SHGC = 0.30 SHGC = 0.30 SHGC = Doors: Exterior door U -factor - NR U -factor = 0.401 U -factor= Floors: Slab -on -Grade NR NR Over unconditioned spaces° R-13 R-13 R -Value - NR Walls": Ext. and Adj. Frame R-13 R-13 R -Value = 13 Mass Insulation on wall interior R-4 R-6 R -Value = Insulation on wall exterior R-3 R-4 R -Value = Ceilings' R-30 R=38 R -Value = Air infiltration Blower door lest is required on the building envelope to verify leakage < 1 ACH; Total leakage = ACH test report provided to code official. Test re ori attached? Yes No Air distribution systems: Air handling unit Not allowed in attic Duct R -value R -value >_ R-8 (supply in attics) or >_ R-6 (all other duct locations) LocR-Vation:At tic Location: At = $ Air leakages: Duct lest Postconstruction test Total Ieakage <_ 4 cfm1100 s.f. Hough -in test Total leakage <_ 4 cfm1100 s.f. (air handler installed) Total leakage = cfm/100s.f. Total leakage <_ 3 cfmli 00 s.f. (air handler not installed) Test report Attached? Yes ® No D Ducts in conditioned space Test not required if all ducts and AHU are in conditioned space Location: Air conditioning system: Minimum federal standard required by NAEW: Central system <_ 65,000 Bluth SEER 14.0 Room unit or PTAC EER [from Table C403.2.3(3)] SEER= Existing Other: See Tables C403.2.3(1)-(11) EER - Heating system: Minimum federal standard required by NAECA6: Heat pump <_ 65,000 Bluth HSPF 8.2 HSpF - Gas furnace, non -weatherized AFUE80% AFUE= Existing Oil furnace, non -weatherized AFUE 83% AFUE = Other: Water heating system (storage type): Minimum federal standard required by NAECA6: Electric' 40 gal: EF = 0.92 Gallons = 50 gal: EF = 0.90 EF= Existing Gas fired' 40 gal: EF = 0.59 Gallons = 50 gal: EF = 0.58 EF = Other (describe): NR = No requirement. (1) Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using this method. (2) For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code, Residential or Section 1609.1.2 of the Florida Building Code, Building, the maximum U -factor shall be 0.65 in Climate Zone 2. An area -weighted average of U -factor and SHGC shall be accepted to meet the requirements, or up to 15 square feet of glazed fenestration area are exempted from the U -factor and SHGC requirement based on Sections 8402.3.1, R402.3.2 and R402.3.3. (3) One side -hinged opaque door assembly up to 24 square feet is exempted from this U -factor requirement. (4) R -values are for insulation material only as applied in accordance with manufacturer's installation instructions. For mass walls, the "interior of wall" requirement must be met except if at least 50 percent of the insulation required for the "exterior of wall" is installed exterior of, or integral to, the wall. (5) Duels & AHU installed "substantially leak free" per Section R403.3.2. Test required by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. (6) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1957 for typical residential equipment and are subject to NAECA rules and regulations. For other types of equipment, see Tables C403.2.3(1-11) of the Commercial Provisions of the Florida Building Code, Energy Conservation. (7) For other electric storage volumes, minimum EF = 0.97 - (0.00132 * volume). (8) For other natural gas storage volumes, minimum EF = 0.67 - (0.0019 * volume). Prepared By; Ace Air Conditioning ilimrny Evans VACiMechaf t:al License. XNE 3 F R-56 FLORIDA BUILDING CODE— ENERGYON, 6th EDITION (2017) FORMS TABLE R402B MANDATORY REQUIREMENTS Component Section Summary of Requirements) Check Air leakage R402.4 To be caulked, gasketed, weatherstripped or otherwise sealed per Table R402.4.1.1, Recessed lighting: IC -rated as having <_ 2.0 cim tested to ASTM E 283. Windows and doors: 0.3 cfmisq. ft. (swinging doors: 0.5 cfm/sf) when tested to NFRC 400 or AAMA(WDMAICSA 1011I.S. 2/A440, Fireplaces: Tight-fitfing flue dampers & outdoor combustion air. Programmable 8403.1.2 A programmable thermostat is required for the primary heating or cooling system. thermostat 8403.3.2 Ducts shall be tested as per Section 8403.3.2 by either individuals as defined in Section 553.993 5 () or (7 Florida ) Air distribution system 8403.3.4 , Statutes, or individuals licensed as set forth in Section 489.105(3)1 , or i ,Florida Statutes. Air handling units (1), ) (g).) ( are not allowed in attics. Water heaters R403.5 Comply with efficiencies in Table C404.2. Hot water pipes insulated to > R-3 to kitchen outlets, other cases. Circulating systems to have an automatic or accessible manual OFF switch. Heal trap required for vertical pipe risers. Swimming pools & spas R403.10 Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heal loss except if 70% of heat from site -recovered energy. Off/timer switch required, Gas heaters minimum thermal efficiency is 82%. Heat pump pool heaters minimum COP is 4.0. Cooling/heating R403.7 Sizing calculation performed & attached. Special occasion cooling or heating capacity requires separate system or equipment variable capacity system. Lighting equipment 8404.1 At least 75% of permanently installed lighting fixtures shall be high -efficacy lamps. Prepared By: Ace Air Conditioning Jimmy Evans HVAC/Mechanical License: ICAC 18113533 FLORIDA BUILDING CODE — ENERGY CONSERVATION, 6th EDITION (2017) U ' V R-57 Building Analysis Entire House W." Ace Air Conditioning Job: 5741 Sunset Blvd. Date: By: Jimmy Evans 2985 Enterprise Rd., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533 For: Detailed Enterprises 5701 Sunset Blvd., Ft. Pierce, FL 34982 Healr� Component R -sign Tdhditiohs:�:� Btuh % of load Walls Location: 3015 Indoor: Heating Cooling Orlando Intl AP, FL, US 10.1 Indoor temperature (°F) 70 75 Elevation: 105 ft Ceilings Design TD (°F) 28 17 Latitude: 28°N 3.3 Relative humidlty N 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 1.3 46.6 Dry bulb (°F) 42 92 Infiltration: 0 Daily range (°F) - 17 (M) Method Simplified 0 Wet bulb (°F - 76 Construction quality Average Adjustments Wind speed (mph) 15.0 7.5 Fireplaces 0 Healr� Component Btuhlft2 Btuh % of load Walls 2.4 3015 16.0 Glazing 13.2 1904 10.1 Doors 11.0 422 2.2 Ceilings 1.3 1587 8.4 Floors 3.3 4155 22.1 Infiltration 1.9 2325 12.3 Ducts 5425 28.8 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 18833 100.0 Floors .......... ... � OEC, ..... ,.......... Component Btuh/ft' Btuh % of load Walls 1.9 2427 9.5 Glazing 51.9 7481 29.2 Doors 11.9 458 1.8 Ceilings 2.4 3047 11.9 Floors 0 0 0 Infiltration 0.6 736 2.9 Ducts. 7092 27.7 Ventilation 0 0 Internal gains 4390 17.1 Blower 0 0 Adjustments 0 Total 25630 100.0 Latent Cooling Load = 3513 Btuh Overall U -value = 0.099 Btuh/ft2-°F Data entries checked. Wrights sift _ w Right -Suite® Universal 2018 18.0.16 RBU00268 ...tions\Detailed Enterprise615701 Sunset Blvd. rup Calc = MJ8 Front Door faces: Gains Other Ceilings Infiltration - prepared By: Ace Air Con Conditioning _ Jimmy Evans HVACIMechanicai License: CAC 1813533 2019 -Oct -21 16:46:25 Page 1 Partitions 12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c. - • • • • 13.0 2.56 Location: 1.42 Indoor: Heating Cooling Orlando Intl AP, FL, US Indoor temperature (°F) 70 75 Elevation: 105 ft Windows Design TD (°F) 28 17 Latitude: 28ON Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 1.3 46.6 Dry bulb (°F) 42 92 Infiltration: Daily range (°F) - 17 ( M) Method Simplified Wet bulb (OF) - 76 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 19 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain 229 Ceilings R, BtuhlR' °F W -Tl tuh MOM Bluh MOW Btu Walls 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112' 12E-Osw: Frm wail, stucco ext, 112" wood shth, r-19 cav ins, 1/2" s 120 0.068 19.0 1.91 229 1.45 174 gypsum board int fns h, 2"x6" wood frm, 16" o.c. stud w 109 0.068 19.0 1.91 209 1.45 159 all 229 0.068 19.0 1.91 438 1.45 333 Partitions 12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c. 73 0.091 13.0 2.56 186 1.42 103 stud Windows 4A4-2ov: 2 glazing, cir outr, argon gas, vnl frm mat, clr low -e innr, 114" w 23 0.470 0 13.2 299 49.3 1118 gap, 114" thk; 1.5 ft overhang (4 ft window ht, 1 ft sep.); 6.67 ft head ht Doors 11 DO: Door, wd s type n 19 0.390 0 11.0 211 11.9 229 Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112' 233 0.032 30.0 0.90 209 1.73 401 gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 32 0.989 0 27.8 875 0 0 Prepared By: CW Ace Air Conditioning Jimmy Evans HVACIMechanical License: CAC1813533 wrightsoft, 2019 -Oct -21 16:46:25 ­­ •, • _,... , Right -Suite® Universal 2018 18.0.16 RSU00268 Page 1 ...tions\Detailed EnterpriseM5701 Sunset Blvd.rup Calc = M48 Front Door faces: E Component Constructions Job: 5701 Sunset Blvd. W1C Date: By: Jimmy Evans "Vt*v" Ace Air Conditioning 2985 Enterprise RCS., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7756 Email: jevans@aceac.com Web: www.aceac.com License: CAc18i3533 For: Detailed Enterprises 5701 Sunset Blvd., Ft. Pierce, FL 34982 jijijjlj 30.0 0.90 30 1.73 57 Location: 0 Indoor: Heating Cooling Orlando Intl AP, FL, US Indoor temperature (°F) 70 75 Elevation: 105 ft Design TD (°F) 28 17 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 1.3 46.6 Dry bulb (°F) 42 92 Infiltration: Daily range (°F) - 17 ( M) Method Simplified Wet bulb (°F) - 76 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Instal R Htg HTM Loss ctg HTM Gain 8l Btuhlft'-°F Il' °FlBtuh Btuh/t` Btu Btuhm2 81uh Walls 12E-Osw: Fmn wall, stucco ext, 1/2" wood shth, r-19 cav ins, 112" n 44 0.068 19.0 1.91 84 1.45 64 gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud w 48 0.068 19.0 1.91 92 1.45 70 all 92 0.068 19.0 1.91 176 1.45 134 Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 33 0.032 30.0 0.90 30 1.73 57 12 0.989 0 27.8 320 0 ' 0 WePrepared Bn Ace Air Conditioning Jimmy Evans HVAC/Mechanical License: CAC1813533 wr'ightsofts 20#9 -Oct -2116:46:25 ,OCk«u,rw^,r.,.•n.. ,w,«,, Right -Suite® Universal 2018 18.0.16 RS000268 Page 2 ...tionslDelailed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E Component Constructions Job: 5701 Sunset Blvd. Date: Bath By: Jimmy Evans wo Ace Air Conditioning 2985 Enterprise Rd., Debary, FL 32713 phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533 • a tin ptis For: Detailed Enterprises 5701 Sunset Blvd., Ft. Pierce, FL 34982 Partitions (none) Windows (none) Boors (none) Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73 gypsum board intfnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0 Prepared By: EWAce Ce Air Air Conditioning Jimmy Evans HVAC/Mechanical License: CAC1813533 67 0 -d- Wriightsaft" 2019-00-21 16:46:25 leCk­. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3 ...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E - r e e • Location: Indoor: Heating Cooling Orlando Intl AP, FL, US Indoor temperature (°F) 70 75 Elevation: 105 ft Design TD (°F) 28 17 Latitude: 280N Relative humidity {%} 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 1.3 46.6 Dry bulb {°F} 42 92 Infiltration: Daily range (°F) - 17 (M) Method Simplified Wet bulb (°F) - 76 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area lJ-value Insui R Htg HTM Loss Cig HTM Gain ft, Bluhlft-r ftx-°F13Iuh Bluhlft' Bluh BluhM' Btu Walls 12E-Osw: Frm wall, stucco ext, 112" wood shth, r-19 cav ins, 112" n 52 0.068 19.0 1.91 99 1.45 75 gypsum board i nt fnsh, 2'W" wood frm, 16" o.c. stud Partitions (none) Windows (none) Boors (none) Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73 gypsum board intfnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0 Prepared By: EWAce Ce Air Air Conditioning Jimmy Evans HVAC/Mechanical License: CAC1813533 67 0 -d- Wriightsaft" 2019-00-21 16:46:25 leCk­. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3 ...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E Sheet 1 Job #: 5701 Sunset Bivd. Performed by Jimmy Evans for: Detailed Enterprises 5701 Sunset Blvd. Ft. Pierce, FL 34982 Ace Air Conditioning 2985 Enterprise Rd. Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7758 www.aceae.com jevans@aceac.com 0'.M WePrepared By: Ace Air Conditioning Jimmy Evans HVAC/Mechanical Li CAC1813533 Scale: 1 :136 Page 1 Right-Suite®Universal 2018 18.0.16 RSU00268 2019 -Oct -21 16:46:27 ...Enterprises15701 Sunset Blvd.rup