HomeMy WebLinkAboutREVISION,ENERGY CALCS, 6.15.20Prepared By;
Ace Air Conditioning
Jimmy Evans FORMS
HVAC/Meohanlcal License:
CAC1813633
FLORIDA BUILDING CODE, ENERGY CONSERVATION
Residential Building Thermal Envelope Approach
FORM R402-2017 Climate Zone m
Scope: Compliance with Section 6401.2(1) of the Florida Building Code, Energy Conservation, shall be demonstrated by the use of Form
R402 for single- and multiple -family residences of three stories or less in height, additions to existing residential buildings, alterations,
renovations and building systems in existing buildings, as applicable. To comply, a building must meet or exceed all of the energy efficiency
requirements on Table R402A and all applicable mandatory requirements summarized in Table R4028 of this form. If a building does not
comply with this method, or by the UA Alternative method, it may still comply under Section 8405 of the Florida Building Code, Energy
Conservation.
PROJECTNAME 5701 Sunset Blvd. BUILDER:
ANDADDRESS:5701 Sunset Blvd.
OWNER: Joseph Mammano PERMITTING OFFICE:
JURISDICTION NUMBER:
PERMIT NUMBER:
General Instructions:
I. Fill in all the applicable spaces of the "To Be Installed" column on Table R402A with the Information requested. All "To Be Installed" values must be
equal to or more efficient than the required levels.
2. Complete page 1 based on the "To Be Installed" column Information.
3. Read the requirements of Table R402B and check each box to indicate your intent to comply with all applicable items.
4. Read, sign and date the "Prepared By" certification statement at the bottom of page 1. The owner or owner's agent must also sign and date the form
1. New construction, addition, or existing building
1. Addit ion
2. Single-family detached or multiple -family attached
2.
3. If multiple -family, number of units covered by this submission
3.
4. Is this a worst case? (yeslno)
4, No
S. Conditioned floor area (sq. ft.)
5. 308
6. Windows, type and area
a) U -factor:
6a. .34
b) Solar Heat Gain Coefficient (SHGC)
6b. .23
c) Area
6c. 25 _
7. Skylights
a) U -factor:
7a.
b) Solar Heat Gain Coefficient (SHGC)
7b.
8. Floor type, area or perimeter, and insulation:
a) Slab -on -grade (13 -value)
Sa. 308
b) Wood, raised (R -value)
ab.
c) Wood, common (R -value)
ac.
d) Concrete, raised (R -value)
8d.
e) Concrete, common (R -value)
8e.
9. Wali type and insulation:
a) Exterior: i. Wood frame (Insulation R -value)
13
9a1.
2. Masonry (Insulation R -value)
9a2.
b) Adjacent: 1. Wood frame (Insulation R -value)
9b1.
2. Masonry (Insulation R -value)
9b2.
10. Cell Ing type and insulation
a) Attic(insulation R -value)
10a. R-38
b) Single assembly (Insulation R -value)
lob.
11. Air distribution system:
a) Duct location, insulation
AttiCr R-8
Ila.
b) AHU location
iib. Existing/ Interior
c) Total duct leakage. Test report attached.
11c. cfmlloo s.f. Yes 0 No ❑
12. Cooling system: a) type
12a. Existing
b) efliciency
12b. Existing
13. Heating system: a)type
138. Existing
b) efficiency
13b. EXiSting
14. HVAC sizing calculation: attached
14. Yes IN No 11
15. Water heating system: a) type
15a. Exist ing
b) efficiency
15b.
I hereby certify that the plans and specifications covered by this form are
Review of plans and specifications covered by this form indicate
In compliance with the Florida Building Code, Energy Conservation.
compliance with the Florida Building Code, Energy Conservation, Before
PREPARED BY: JiMmy Evans Date -10-21-19
construction is.complete, this building will be inspected for compliance In
hereby certify that this building Is In compliance with the Florida Building
accordance with Section 553.908, F.S.
Code, Energy Conservation.
CODE OFFICIAL:
OWNERIAGENT: Date:
Date:
FLORIDA BUILDING CODE - ENERGY CONSERVATION, 6th EDITION (2017) R-55
Prepared By;
Ace Air Conditioning
Jimmy Evans FORMS
HVAC/Meohanlcal License:
CAC1813633
FLORIDA BUILDING CODE, ENERGY CONSERVATION
Residential Building Thermal Envelope Approach
FORM R402-2017 Climate Zone m
Scope: Compliance with Section 6401.2(1) of the Florida Building Code, Energy Conservation, shall be demonstrated by the use of Form
R402 for single- and multiple -family residences of three stories or less in height, additions to existing residential buildings, alterations,
renovations and building systems in existing buildings, as applicable. To comply, a building must meet or exceed all of the energy efficiency
requirements on Table R402A and all applicable mandatory requirements summarized in Table R4028 of this form. If a building does not
comply with this method, or by the UA Alternative method, it may still comply under Section 8405 of the Florida Building Code, Energy
Conservation.
PROJECTNAME 5701 Sunset Blvd. BUILDER:
ANDADDRESS:5701 Sunset Blvd.
OWNER: Joseph Mammano PERMITTING OFFICE:
JURISDICTION NUMBER:
PERMIT NUMBER:
General Instructions:
I. Fill in all the applicable spaces of the "To Be Installed" column on Table R402A with the Information requested. All "To Be Installed" values must be
equal to or more efficient than the required levels.
2. Complete page 1 based on the "To Be Installed" column Information.
3. Read the requirements of Table R402B and check each box to indicate your intent to comply with all applicable items.
4. Read, sign and date the "Prepared By" certification statement at the bottom of page 1. The owner or owner's agent must also sign and date the form
1. New construction, addition, or existing building
1. Addit ion
2. Single-family detached or multiple -family attached
2.
3. If multiple -family, number of units covered by this submission
3.
4. Is this a worst case? (yeslno)
4, No
S. Conditioned floor area (sq. ft.)
5. 308
6. Windows, type and area
a) U -factor:
6a. .34
b) Solar Heat Gain Coefficient (SHGC)
6b. .23
c) Area
6c. 25 _
7. Skylights
a) U -factor:
7a.
b) Solar Heat Gain Coefficient (SHGC)
7b.
8. Floor type, area or perimeter, and insulation:
a) Slab -on -grade (13 -value)
Sa. 308
b) Wood, raised (R -value)
ab.
c) Wood, common (R -value)
ac.
d) Concrete, raised (R -value)
8d.
e) Concrete, common (R -value)
8e.
9. Wali type and insulation:
a) Exterior: i. Wood frame (Insulation R -value)
13
9a1.
2. Masonry (Insulation R -value)
9a2.
b) Adjacent: 1. Wood frame (Insulation R -value)
9b1.
2. Masonry (Insulation R -value)
9b2.
10. Cell Ing type and insulation
a) Attic(insulation R -value)
10a. R-38
b) Single assembly (Insulation R -value)
lob.
11. Air distribution system:
a) Duct location, insulation
AttiCr R-8
Ila.
b) AHU location
iib. Existing/ Interior
c) Total duct leakage. Test report attached.
11c. cfmlloo s.f. Yes 0 No ❑
12. Cooling system: a) type
12a. Existing
b) efliciency
12b. Existing
13. Heating system: a)type
138. Existing
b) efficiency
13b. EXiSting
14. HVAC sizing calculation: attached
14. Yes IN No 11
15. Water heating system: a) type
15a. Exist ing
b) efficiency
15b.
I hereby certify that the plans and specifications covered by this form are
Review of plans and specifications covered by this form indicate
In compliance with the Florida Building Code, Energy Conservation.
compliance with the Florida Building Code, Energy Conservation, Before
PREPARED BY: JiMmy Evans Date -10-21-19
construction is.complete, this building will be inspected for compliance In
hereby certify that this building Is In compliance with the Florida Building
accordance with Section 553.908, F.S.
Code, Energy Conservation.
CODE OFFICIAL:
OWNERIAGENT: Date:
Date:
FLORIDA BUILDING CODE - ENERGY CONSERVATION, 6th EDITION (2017) R-55
I
FORMS
TABLE R402A
BUILDING COMPONENT
PRESCRIPTIVE REQUIREMENTS'
INSTALLED VALUES
Climate Zone 1
Climate Zone 2
Windows
U -Factor = NR
U -Factor = 0.401
U -Factor = . 3 4
SHGC = 0.25
SHGC = 0-25
SHGC = - 2 3
Skylights
U -factor = 0.75
U -factor = 0.65
U -factor =
SHGC = 0.30
SHGC = 0.30
SHGC =
Doors: Exterior door
U -factor - NR
U -factor = 0.401
U -factor=
Floors:
Slab -on -Grade
NR
NR
Over unconditioned spaces°
R-13
R-13
R -Value - NR
Walls": Ext. and Adj.
Frame
R-13
R-13
R -Value = 13
Mass
Insulation on wall interior
R-4
R-6
R -Value =
Insulation on wall exterior
R-3
R-4
R -Value =
Ceilings'
R-30
R=38
R -Value =
Air infiltration
Blower door lest is required on the building envelope to verify leakage < 1 ACH;
Total leakage = ACH
test report provided to code official.
Test re ori attached?
Yes No
Air distribution systems:
Air handling unit
Not allowed in attic
Duct R -value
R -value >_ R-8 (supply in attics) or >_ R-6 (all other duct locations)
LocR-Vation:At tic
Location: At
= $
Air leakages:
Duct lest
Postconstruction test Total Ieakage <_ 4 cfm1100 s.f.
Hough -in test Total leakage <_ 4 cfm1100 s.f. (air handler installed)
Total leakage = cfm/100s.f.
Total leakage <_ 3 cfmli 00 s.f. (air handler not installed)
Test report Attached? Yes ® No D
Ducts in conditioned space
Test not required if all ducts and AHU are in conditioned space
Location:
Air conditioning system:
Minimum federal standard required by NAEW:
Central system <_ 65,000 Bluth
SEER 14.0
Room unit or PTAC
EER [from Table C403.2.3(3)]
SEER= Existing
Other:
See Tables C403.2.3(1)-(11)
EER -
Heating system:
Minimum federal standard required by NAECA6:
Heat pump <_ 65,000 Bluth
HSPF 8.2
HSpF -
Gas furnace, non -weatherized
AFUE80%
AFUE= Existing
Oil furnace, non -weatherized
AFUE 83%
AFUE =
Other:
Water heating system (storage type):
Minimum federal standard required by NAECA6:
Electric'
40 gal: EF = 0.92
Gallons =
50 gal: EF = 0.90
EF= Existing
Gas fired'
40 gal: EF = 0.59
Gallons =
50 gal: EF = 0.58
EF =
Other (describe):
NR = No requirement.
(1) Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using
this method.
(2) For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code, Residential or Section 1609.1.2 of the Florida Building Code,
Building, the maximum U -factor shall be 0.65 in Climate Zone 2. An area -weighted average of U -factor and SHGC shall be accepted to meet the
requirements, or up to 15 square feet of glazed fenestration area are exempted from the U -factor and SHGC requirement based on Sections 8402.3.1,
R402.3.2 and R402.3.3.
(3) One side -hinged opaque door assembly up to 24 square feet is exempted from this U -factor requirement.
(4) R -values are for insulation material only as applied in accordance with manufacturer's installation instructions. For mass walls, the "interior of wall"
requirement must be met except if at least 50 percent of the insulation required for the "exterior of wall" is installed exterior of, or integral to, the wall.
(5) Duels & AHU installed "substantially leak free" per Section R403.3.2. Test required by either individuals as defined in Section 553.993(5) or (7), Florida
Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. The total leakage test is not required for ducts and air
handlers located entirely within the building thermal envelope.
(6) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1957 for typical residential equipment and are subject to NAECA
rules and regulations. For other types of equipment, see Tables C403.2.3(1-11) of the Commercial Provisions of the Florida Building Code, Energy
Conservation.
(7) For other electric storage volumes, minimum EF = 0.97 - (0.00132 * volume).
(8) For other natural gas storage volumes, minimum EF = 0.67 - (0.0019 * volume).
Prepared By;
Ace Air Conditioning
ilimrny Evans
VACiMechaf t:al License.
XNE
3
F
R-56 FLORIDA BUILDING CODE— ENERGYON, 6th EDITION (2017)
FORMS
TABLE R402B MANDATORY REQUIREMENTS
Component
Section
Summary of Requirements)
Check
Air leakage
R402.4
To be caulked, gasketed, weatherstripped or otherwise sealed per Table R402.4.1.1, Recessed lighting: IC -rated as
having <_ 2.0 cim tested to ASTM E 283.
Windows and doors: 0.3 cfmisq. ft. (swinging doors: 0.5 cfm/sf) when tested to NFRC 400 or
AAMA(WDMAICSA 1011I.S. 2/A440,
Fireplaces: Tight-fitfing flue dampers & outdoor combustion air.
Programmable
8403.1.2
A programmable thermostat is required for the primary heating or cooling system.
thermostat
8403.3.2
Ducts shall be tested as per Section 8403.3.2 by either individuals as defined in Section 553.993 5
() or (7 Florida
)
Air distribution system
8403.3.4
,
Statutes, or individuals licensed as set forth in Section 489.105(3)1 , or i ,Florida Statutes. Air handling units
(1),
) (g).) (
are not allowed in attics.
Water heaters
R403.5
Comply with efficiencies in Table C404.2. Hot water pipes insulated to > R-3 to kitchen outlets, other cases.
Circulating systems to have an automatic or accessible manual OFF switch. Heal trap required for vertical pipe
risers.
Swimming pools & spas
R403.10
Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heal
loss except if 70% of heat from site -recovered energy. Off/timer switch required, Gas heaters minimum thermal
efficiency is 82%. Heat pump pool heaters minimum COP is 4.0.
Cooling/heating
R403.7
Sizing calculation performed & attached. Special occasion cooling or heating capacity requires separate system or
equipment
variable capacity system.
Lighting equipment
8404.1
At least 75% of permanently installed lighting fixtures shall be high -efficacy lamps.
Prepared By:
Ace Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
ICAC 18113533
FLORIDA BUILDING CODE — ENERGY CONSERVATION, 6th EDITION (2017) U ' V R-57
Building Analysis
Entire House
W." Ace Air Conditioning
Job: 5741 Sunset Blvd.
Date:
By: Jimmy Evans
2985 Enterprise Rd., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533
For: Detailed Enterprises
5701 Sunset Blvd., Ft. Pierce, FL 34982
Healr�
Component
R -sign Tdhditiohs:�:�
Btuh
% of load
Walls
Location:
3015
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
10.1
Indoor temperature (°F)
70
75
Elevation: 105 ft
Ceilings
Design TD (°F)
28
17
Latitude: 28°N
3.3
Relative humidlty N
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.3
46.6
Dry bulb (°F) 42
92
Infiltration:
0
Daily range (°F) -
17 (M)
Method
Simplified
0
Wet bulb (°F -
76
Construction quality
Average
Adjustments
Wind speed (mph) 15.0
7.5
Fireplaces
0
Healr�
Component
Btuhlft2
Btuh
% of load
Walls
2.4
3015
16.0
Glazing
13.2
1904
10.1
Doors
11.0
422
2.2
Ceilings
1.3
1587
8.4
Floors
3.3
4155
22.1
Infiltration
1.9
2325
12.3
Ducts
5425
28.8
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
Total
18833
100.0
Floors
.......... ... � OEC, ..... ,..........
Component
Btuh/ft'
Btuh
% of load
Walls
1.9
2427
9.5
Glazing
51.9
7481
29.2
Doors
11.9
458
1.8
Ceilings
2.4
3047
11.9
Floors
0
0
0
Infiltration
0.6
736
2.9
Ducts.
7092
27.7
Ventilation
0
0
Internal gains
4390
17.1
Blower
0
0
Adjustments
0
Total
25630
100.0
Latent Cooling Load = 3513 Btuh
Overall U -value = 0.099 Btuh/ft2-°F
Data entries checked.
Wrights sift _
w Right -Suite® Universal 2018 18.0.16 RBU00268
...tions\Detailed Enterprise615701 Sunset Blvd. rup Calc = MJ8 Front Door faces:
Gains
Other
Ceilings Infiltration
- prepared By:
Ace Air
Con Conditioning
_ Jimmy Evans
HVACIMechanicai License:
CAC 1813533
2019 -Oct -21 16:46:25
Page 1
Partitions
12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c.
- • •
• •
13.0
2.56
Location:
1.42
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
Indoor temperature (°F)
70
75
Elevation: 105 ft
Windows
Design TD (°F)
28
17
Latitude: 28ON
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.3
46.6
Dry bulb (°F) 42
92
Infiltration:
Daily range (°F) -
17 ( M)
Method
Simplified
Wet bulb (OF) -
76
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
19
Construction descriptions
Or
Area U -value Insul R
Htg HTM
Loss Clg HTM Gain
229
Ceilings
R, BtuhlR' °F W -Tl tuh
MOM
Bluh MOW Btu
Walls
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112'
12E-Osw: Frm wail, stucco ext, 112" wood shth, r-19 cav ins, 1/2" s
120 0.068 19.0
1.91
229 1.45 174
gypsum board int fns h, 2"x6" wood frm, 16" o.c. stud
w
109 0.068 19.0
1.91
209 1.45 159
all
229 0.068 19.0
1.91
438 1.45 333
Partitions
12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c.
73
0.091
13.0
2.56
186
1.42
103
stud
Windows
4A4-2ov: 2 glazing, cir outr, argon gas, vnl frm mat, clr low -e innr, 114" w
23
0.470
0
13.2
299
49.3
1118
gap, 114" thk; 1.5 ft overhang (4 ft window ht, 1 ft sep.); 6.67 ft head ht
Doors
11 DO: Door, wd s type n
19
0.390
0
11.0
211
11.9
229
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112'
233
0.032
30.0
0.90
209
1.73
401
gypsum board int fnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh
32
0.989
0
27.8
875
0
0
Prepared By:
CW Ace Air Conditioning
Jimmy Evans
HVACIMechanical License:
CAC1813533
wrightsoft, 2019 -Oct -21 16:46:25
•, • _,... , Right -Suite® Universal 2018 18.0.16 RSU00268 Page 1
...tions\Detailed EnterpriseM5701 Sunset Blvd.rup Calc = M48 Front Door faces: E
Component Constructions Job: 5701 Sunset Blvd.
W1C Date:
By: Jimmy Evans
"Vt*v"
Ace Air Conditioning
2985 Enterprise RCS., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7756 Email: jevans@aceac.com Web: www.aceac.com License: CAc18i3533
For: Detailed Enterprises
5701 Sunset Blvd., Ft. Pierce, FL 34982
jijijjlj
30.0
0.90
30
1.73 57
Location:
0
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
Indoor temperature (°F)
70
75
Elevation: 105 ft
Design TD (°F)
28
17
Latitude: 28°N
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/Ib)
1.3
46.6
Dry bulb (°F) 42
92
Infiltration:
Daily range (°F) -
17 ( M)
Method
Simplified
Wet bulb (°F) -
76
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions
Or
Area U -value Instal R
Htg HTM
Loss ctg HTM Gain
8l Btuhlft'-°F Il' °FlBtuh
Btuh/t`
Btu Btuhm2 81uh
Walls
12E-Osw: Fmn wall, stucco ext, 1/2" wood shth, r-19 cav ins, 112" n
44 0.068 19.0
1.91
84 1.45 64
gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud
w
48 0.068 19.0
1.91
92 1.45 70
all
92 0.068 19.0
1.91
176 1.45 134
Partitions
(none)
Windows
(none)
Doors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112"
gypsum board int fnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh
33 0.032
30.0
0.90
30
1.73 57
12 0.989
0
27.8
320
0 ' 0
WePrepared Bn
Ace Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
CAC1813533
wr'ightsofts 20#9 -Oct -2116:46:25
,OCk«u,rw^,r.,.•n.. ,w,«,, Right -Suite® Universal 2018 18.0.16 RS000268 Page 2
...tionslDelailed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E
Component Constructions Job: 5701 Sunset Blvd.
Date:
Bath By: Jimmy Evans
wo Ace Air Conditioning
2985 Enterprise Rd., Debary, FL 32713 phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533
• a tin ptis
For: Detailed Enterprises
5701 Sunset Blvd., Ft. Pierce, FL 34982
Partitions
(none)
Windows
(none)
Boors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73
gypsum board intfnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0
Prepared By:
EWAce Ce Air Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
CAC1813533
67
0
-d- Wriightsaft" 2019-00-21 16:46:25
leCk. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3
...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E
- r e
e •
Location:
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
Indoor temperature (°F)
70
75
Elevation: 105 ft
Design TD (°F)
28
17
Latitude: 280N
Relative humidity {%}
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.3
46.6
Dry bulb {°F} 42
92
Infiltration:
Daily range (°F) -
17 (M)
Method
Simplified
Wet bulb (°F) -
76
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions
or
Area lJ-value Insui R
Htg HTM
Loss Cig HTM Gain
ft, Bluhlft-r ftx-°F13Iuh
Bluhlft'
Bluh BluhM' Btu
Walls
12E-Osw: Frm wall, stucco ext, 112" wood shth, r-19 cav ins, 112" n
52 0.068 19.0
1.91
99 1.45 75
gypsum board i nt fnsh, 2'W" wood frm, 16" o.c. stud
Partitions
(none)
Windows
(none)
Boors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73
gypsum board intfnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0
Prepared By:
EWAce Ce Air Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
CAC1813533
67
0
-d- Wriightsaft" 2019-00-21 16:46:25
leCk. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3
...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E
Sheet 1
Job #: 5701 Sunset Bivd.
Performed by Jimmy Evans for:
Detailed Enterprises
5701 Sunset Blvd.
Ft. Pierce, FL 34982
Ace Air Conditioning
2985 Enterprise Rd.
Debary, FL 32713
Phone: 386-668-8651 Fax: 386-668-7758
www.aceae.com jevans@aceac.com
0'.M
WePrepared By:
Ace Air Conditioning
Jimmy Evans
HVAC/Mechanical Li
CAC1813533
Scale: 1 :136
Page 1
Right-Suite®Universal 2018
18.0.16 RSU00268
2019 -Oct -21 16:46:27
...Enterprises15701 Sunset Blvd.rup
I
FORMS
TABLE R402A
BUILDING COMPONENT
PRESCRIPTIVE REQUIREMENTS'
INSTALLED VALUES
Climate Zone 1
Climate Zone 2
Windows
U -Factor = NR
U -Factor = 0.401
U -Factor = . 3 4
SHGC = 0.25
SHGC = 0-25
SHGC = - 2 3
Skylights
U -factor = 0.75
U -factor = 0.65
U -factor =
SHGC = 0.30
SHGC = 0.30
SHGC =
Doors: Exterior door
U -factor - NR
U -factor = 0.401
U -factor=
Floors:
Slab -on -Grade
NR
NR
Over unconditioned spaces°
R-13
R-13
R -Value - NR
Walls": Ext. and Adj.
Frame
R-13
R-13
R -Value = 13
Mass
Insulation on wall interior
R-4
R-6
R -Value =
Insulation on wall exterior
R-3
R-4
R -Value =
Ceilings'
R-30
R=38
R -Value =
Air infiltration
Blower door lest is required on the building envelope to verify leakage < 1 ACH;
Total leakage = ACH
test report provided to code official.
Test re ori attached?
Yes No
Air distribution systems:
Air handling unit
Not allowed in attic
Duct R -value
R -value >_ R-8 (supply in attics) or >_ R-6 (all other duct locations)
LocR-Vation:At tic
Location: At
= $
Air leakages:
Duct lest
Postconstruction test Total Ieakage <_ 4 cfm1100 s.f.
Hough -in test Total leakage <_ 4 cfm1100 s.f. (air handler installed)
Total leakage = cfm/100s.f.
Total leakage <_ 3 cfmli 00 s.f. (air handler not installed)
Test report Attached? Yes ® No D
Ducts in conditioned space
Test not required if all ducts and AHU are in conditioned space
Location:
Air conditioning system:
Minimum federal standard required by NAEW:
Central system <_ 65,000 Bluth
SEER 14.0
Room unit or PTAC
EER [from Table C403.2.3(3)]
SEER= Existing
Other:
See Tables C403.2.3(1)-(11)
EER -
Heating system:
Minimum federal standard required by NAECA6:
Heat pump <_ 65,000 Bluth
HSPF 8.2
HSpF -
Gas furnace, non -weatherized
AFUE80%
AFUE= Existing
Oil furnace, non -weatherized
AFUE 83%
AFUE =
Other:
Water heating system (storage type):
Minimum federal standard required by NAECA6:
Electric'
40 gal: EF = 0.92
Gallons =
50 gal: EF = 0.90
EF= Existing
Gas fired'
40 gal: EF = 0.59
Gallons =
50 gal: EF = 0.58
EF =
Other (describe):
NR = No requirement.
(1) Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using
this method.
(2) For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code, Residential or Section 1609.1.2 of the Florida Building Code,
Building, the maximum U -factor shall be 0.65 in Climate Zone 2. An area -weighted average of U -factor and SHGC shall be accepted to meet the
requirements, or up to 15 square feet of glazed fenestration area are exempted from the U -factor and SHGC requirement based on Sections 8402.3.1,
R402.3.2 and R402.3.3.
(3) One side -hinged opaque door assembly up to 24 square feet is exempted from this U -factor requirement.
(4) R -values are for insulation material only as applied in accordance with manufacturer's installation instructions. For mass walls, the "interior of wall"
requirement must be met except if at least 50 percent of the insulation required for the "exterior of wall" is installed exterior of, or integral to, the wall.
(5) Duels & AHU installed "substantially leak free" per Section R403.3.2. Test required by either individuals as defined in Section 553.993(5) or (7), Florida
Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. The total leakage test is not required for ducts and air
handlers located entirely within the building thermal envelope.
(6) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1957 for typical residential equipment and are subject to NAECA
rules and regulations. For other types of equipment, see Tables C403.2.3(1-11) of the Commercial Provisions of the Florida Building Code, Energy
Conservation.
(7) For other electric storage volumes, minimum EF = 0.97 - (0.00132 * volume).
(8) For other natural gas storage volumes, minimum EF = 0.67 - (0.0019 * volume).
Prepared By;
Ace Air Conditioning
ilimrny Evans
VACiMechaf t:al License.
XNE
3
F
R-56 FLORIDA BUILDING CODE— ENERGYON, 6th EDITION (2017)
FORMS
TABLE R402B MANDATORY REQUIREMENTS
Component
Section
Summary of Requirements)
Check
Air leakage
R402.4
To be caulked, gasketed, weatherstripped or otherwise sealed per Table R402.4.1.1, Recessed lighting: IC -rated as
having <_ 2.0 cim tested to ASTM E 283.
Windows and doors: 0.3 cfmisq. ft. (swinging doors: 0.5 cfm/sf) when tested to NFRC 400 or
AAMA(WDMAICSA 1011I.S. 2/A440,
Fireplaces: Tight-fitfing flue dampers & outdoor combustion air.
Programmable
8403.1.2
A programmable thermostat is required for the primary heating or cooling system.
thermostat
8403.3.2
Ducts shall be tested as per Section 8403.3.2 by either individuals as defined in Section 553.993 5
() or (7 Florida
)
Air distribution system
8403.3.4
,
Statutes, or individuals licensed as set forth in Section 489.105(3)1 , or i ,Florida Statutes. Air handling units
(1),
) (g).) (
are not allowed in attics.
Water heaters
R403.5
Comply with efficiencies in Table C404.2. Hot water pipes insulated to > R-3 to kitchen outlets, other cases.
Circulating systems to have an automatic or accessible manual OFF switch. Heal trap required for vertical pipe
risers.
Swimming pools & spas
R403.10
Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heal
loss except if 70% of heat from site -recovered energy. Off/timer switch required, Gas heaters minimum thermal
efficiency is 82%. Heat pump pool heaters minimum COP is 4.0.
Cooling/heating
R403.7
Sizing calculation performed & attached. Special occasion cooling or heating capacity requires separate system or
equipment
variable capacity system.
Lighting equipment
8404.1
At least 75% of permanently installed lighting fixtures shall be high -efficacy lamps.
Prepared By:
Ace Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
ICAC 18113533
FLORIDA BUILDING CODE — ENERGY CONSERVATION, 6th EDITION (2017) U ' V R-57
Building Analysis
Entire House
W." Ace Air Conditioning
Job: 5741 Sunset Blvd.
Date:
By: Jimmy Evans
2985 Enterprise Rd., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533
For: Detailed Enterprises
5701 Sunset Blvd., Ft. Pierce, FL 34982
Healr�
Component
R -sign Tdhditiohs:�:�
Btuh
% of load
Walls
Location:
3015
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
10.1
Indoor temperature (°F)
70
75
Elevation: 105 ft
Ceilings
Design TD (°F)
28
17
Latitude: 28°N
3.3
Relative humidlty N
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.3
46.6
Dry bulb (°F) 42
92
Infiltration:
0
Daily range (°F) -
17 (M)
Method
Simplified
0
Wet bulb (°F -
76
Construction quality
Average
Adjustments
Wind speed (mph) 15.0
7.5
Fireplaces
0
Healr�
Component
Btuhlft2
Btuh
% of load
Walls
2.4
3015
16.0
Glazing
13.2
1904
10.1
Doors
11.0
422
2.2
Ceilings
1.3
1587
8.4
Floors
3.3
4155
22.1
Infiltration
1.9
2325
12.3
Ducts
5425
28.8
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
Total
18833
100.0
Floors
.......... ... � OEC, ..... ,..........
Component
Btuh/ft'
Btuh
% of load
Walls
1.9
2427
9.5
Glazing
51.9
7481
29.2
Doors
11.9
458
1.8
Ceilings
2.4
3047
11.9
Floors
0
0
0
Infiltration
0.6
736
2.9
Ducts.
7092
27.7
Ventilation
0
0
Internal gains
4390
17.1
Blower
0
0
Adjustments
0
Total
25630
100.0
Latent Cooling Load = 3513 Btuh
Overall U -value = 0.099 Btuh/ft2-°F
Data entries checked.
Wrights sift _
w Right -Suite® Universal 2018 18.0.16 RBU00268
...tions\Detailed Enterprise615701 Sunset Blvd. rup Calc = MJ8 Front Door faces:
Gains
Other
Ceilings Infiltration
- prepared By:
Ace Air
Con Conditioning
_ Jimmy Evans
HVACIMechanicai License:
CAC 1813533
2019 -Oct -21 16:46:25
Page 1
Partitions
12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c.
- • •
• •
13.0
2.56
Location:
1.42
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
Indoor temperature (°F)
70
75
Elevation: 105 ft
Windows
Design TD (°F)
28
17
Latitude: 28ON
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.3
46.6
Dry bulb (°F) 42
92
Infiltration:
Daily range (°F) -
17 ( M)
Method
Simplified
Wet bulb (OF) -
76
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
19
Construction descriptions
Or
Area U -value Insul R
Htg HTM
Loss Clg HTM Gain
229
Ceilings
R, BtuhlR' °F W -Tl tuh
MOM
Bluh MOW Btu
Walls
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112'
12E-Osw: Frm wail, stucco ext, 112" wood shth, r-19 cav ins, 1/2" s
120 0.068 19.0
1.91
229 1.45 174
gypsum board int fns h, 2"x6" wood frm, 16" o.c. stud
w
109 0.068 19.0
1.91
209 1.45 159
all
229 0.068 19.0
1.91
438 1.45 333
Partitions
12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2'x4" wood frm, 16" o.c.
73
0.091
13.0
2.56
186
1.42
103
stud
Windows
4A4-2ov: 2 glazing, cir outr, argon gas, vnl frm mat, clr low -e innr, 114" w
23
0.470
0
13.2
299
49.3
1118
gap, 114" thk; 1.5 ft overhang (4 ft window ht, 1 ft sep.); 6.67 ft head ht
Doors
11 DO: Door, wd s type n
19
0.390
0
11.0
211
11.9
229
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 veil ins, 112'
233
0.032
30.0
0.90
209
1.73
401
gypsum board int fnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh
32
0.989
0
27.8
875
0
0
Prepared By:
CW Ace Air Conditioning
Jimmy Evans
HVACIMechanical License:
CAC1813533
wrightsoft, 2019 -Oct -21 16:46:25
•, • _,... , Right -Suite® Universal 2018 18.0.16 RSU00268 Page 1
...tions\Detailed EnterpriseM5701 Sunset Blvd.rup Calc = M48 Front Door faces: E
Component Constructions Job: 5701 Sunset Blvd.
W1C Date:
By: Jimmy Evans
"Vt*v"
Ace Air Conditioning
2985 Enterprise RCS., Debary, FL 32713 Phone: 386-668-8651 Fax: 386-668-7756 Email: jevans@aceac.com Web: www.aceac.com License: CAc18i3533
For: Detailed Enterprises
5701 Sunset Blvd., Ft. Pierce, FL 34982
jijijjlj
30.0
0.90
30
1.73 57
Location:
0
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
Indoor temperature (°F)
70
75
Elevation: 105 ft
Design TD (°F)
28
17
Latitude: 28°N
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/Ib)
1.3
46.6
Dry bulb (°F) 42
92
Infiltration:
Daily range (°F) -
17 ( M)
Method
Simplified
Wet bulb (°F) -
76
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions
Or
Area U -value Instal R
Htg HTM
Loss ctg HTM Gain
8l Btuhlft'-°F Il' °FlBtuh
Btuh/t`
Btu Btuhm2 81uh
Walls
12E-Osw: Fmn wall, stucco ext, 1/2" wood shth, r-19 cav ins, 112" n
44 0.068 19.0
1.91
84 1.45 64
gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud
w
48 0.068 19.0
1.91
92 1.45 70
all
92 0.068 19.0
1.91
176 1.45 134
Partitions
(none)
Windows
(none)
Doors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112"
gypsum board int fnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh
33 0.032
30.0
0.90
30
1.73 57
12 0.989
0
27.8
320
0 ' 0
WePrepared Bn
Ace Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
CAC1813533
wr'ightsofts 20#9 -Oct -2116:46:25
,OCk«u,rw^,r.,.•n.. ,w,«,, Right -Suite® Universal 2018 18.0.16 RS000268 Page 2
...tionslDelailed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E
Component Constructions Job: 5701 Sunset Blvd.
Date:
Bath By: Jimmy Evans
wo Ace Air Conditioning
2985 Enterprise Rd., Debary, FL 32713 phone: 386-668-8651 Fax: 386-668-7758 Email: jevans@aceac.com Web: www.aceac.com License: CAC1813533
• a tin ptis
For: Detailed Enterprises
5701 Sunset Blvd., Ft. Pierce, FL 34982
Partitions
(none)
Windows
(none)
Boors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73
gypsum board intfnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0
Prepared By:
EWAce Ce Air Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
CAC1813533
67
0
-d- Wriightsaft" 2019-00-21 16:46:25
leCk. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3
...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E
- r e
e •
Location:
Indoor:
Heating
Cooling
Orlando Intl AP, FL, US
Indoor temperature (°F)
70
75
Elevation: 105 ft
Design TD (°F)
28
17
Latitude: 280N
Relative humidity {%}
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
1.3
46.6
Dry bulb {°F} 42
92
Infiltration:
Daily range (°F) -
17 (M)
Method
Simplified
Wet bulb (°F) -
76
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions
or
Area lJ-value Insui R
Htg HTM
Loss Cig HTM Gain
ft, Bluhlft-r ftx-°F13Iuh
Bluhlft'
Bluh BluhM' Btu
Walls
12E-Osw: Frm wall, stucco ext, 112" wood shth, r-19 cav ins, 112" n
52 0.068 19.0
1.91
99 1.45 75
gypsum board i nt fnsh, 2'W" wood frm, 16" o.c. stud
Partitions
(none)
Windows
(none)
Boors
(none)
Ceilings
16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 112" 39 0.032 30,0 0.90 35 1.73
gypsum board intfnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth, tile flr fnsh 7 0.989 0 27.8 181 0
Prepared By:
EWAce Ce Air Air Conditioning
Jimmy Evans
HVAC/Mechanical License:
CAC1813533
67
0
-d- Wriightsaft" 2019-00-21 16:46:25
leCk. -,.,, -"-'.,,a..M<, Right -Suite® Universal 2018 18.0.16 RS000268 Page 3
...lionslDetaifed Enlerprises15701 Sunset Blvd.rup Calc = MJ8 Front Door faces: E
Sheet 1
Job #: 5701 Sunset Bivd.
Performed by Jimmy Evans for:
Detailed Enterprises
5701 Sunset Blvd.
Ft. Pierce, FL 34982
Ace Air Conditioning
2985 Enterprise Rd.
Debary, FL 32713
Phone: 386-668-8651 Fax: 386-668-7758
www.aceae.com jevans@aceac.com
0'.M
WePrepared By:
Ace Air Conditioning
Jimmy Evans
HVAC/Mechanical Li
CAC1813533
Scale: 1 :136
Page 1
Right-Suite®Universal 2018
18.0.16 RSU00268
2019 -Oct -21 16:46:27
...Enterprises15701 Sunset Blvd.rup