HomeMy WebLinkAboutStep Performance Test ReportArchitectural Testing STEP PERFORMANCE TEST REPORT Rendered to: STYLE CREST MANUFACTURING, INC. SERIES: 4-Tread, Dura-Grip II, Step Unit Report No: 01-37911.04 Report Date: 11/07/03 6 Five 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com Architectural Testing STEP PERFORMANCE TEST REPORT Rendered to: STYLE CREST MANUFACTURING, INC. 600 Hagerty Drive P.O. Box 690 Fremont, Ohio 43420 Report No.: 01-37911.04 Test Date: 09/01/00 Report Date: 11/07/03 Project Summary: Architectural Testing, Inc. (ATI) was contracted by Style Crest Manufacturing, Inc. to conduct structural performance tests on a five riser, four tread and built in landing, self supporting fiberglass Dura-Grip II, step unit. The system was evaluated for the design load requirements and dimensional requirements only of the following building codes and standards: BOCA-1999 - Building Officials and Code Administrators (Reference ASCE 7-95) UBC-1997 / ICBO - International Conference of Building Officials SBC-1997 / SBCCI - Southern Building Code Conference International International Residential Code, 2000 International Residential Code, 2003 Residential Code of New York State, 2002 Florida Building Code, 2001 (Revised 2003) North Carolina Residential Code, 2002 Test Specimen (Step Assembly) Description: The step unit was fabricated with a pressure treated lumber framework and a layer of fiberglass over the entire structure. The step unit was 38" wide and had an overall height of 35". The five risers were each 7" high. The four treads were each 11-1/2" deep. The landing was 38-1/2" deep to the nosing. The leading edge, tread radius measured less than 9/16" (see attached photographs for visual clarification of step structure). The manufacturer provided all components and fasteners comprising the test specimen. 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717,764.4129 www.archtest.com 01-37911.04 Page 2 of 6 Test Procedures: The following tests were performed on the step structure for the requirements of each code or standard as referenced. Tests Conducted: Stairway dimension verification in accordance with the following: A) International Residential Code, 2000 B) CABO, 1995 C) Standard Building Code, 1999 D) Uniform Building Code, 1997 E) BOCA, 1999 F) International Residential Code, 2003 G) Residential Code of New York State, 2002 H) North Carolina Residential Code, 2002 1) Florida Building Code, 2001 (Revised 2003) 2. 300 lb treadload over 4 sq. in. (design load) test performed on the center of stair tread. Loading and Measurement Procedure: The loads were applied to the components of the system following ATI's Test Procedure. All deflection measurements were taken using electronic deflection transducers. Equipment: The components were loaded using a hydraulic press with an electrical load cell for measurement of each load. Test Results: The following tables list the results of data collected during testing and compare it to the appropriate code requirement. Test 1 - Dimensional Verification in Accordance with IRC - 2000 Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 7-3/4" 7" - Pass Tread Depth Minimum 10" I 1-1/2" - Pass Tread Leading Edge Radius Maximum 9/16" less than 1/2" - Pass Dimensional Verification in Accordance with CABO -1991 Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 7-3/4" 7" - Pass Tread Depth Minimum 10" 11-1/2" - Pass Tread Leading Edge Radius Maximum 9/16" less than 1/2" - Pass 01-37911.04 Page 3 of 6 Test Results: (Continued) Dimensional Verification in Accordance with SBC -1999 Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 7-3/4" 7" - Pass Tread Depth Minimum 10" 11-1/2" - Pass Dimensional Verification in Accordance with UBC - 1997 Stairway Dimension Requirement Tested Value Width , Minimum 36" 38" - Pass Riser Height Maximum 8" 7" - Pass Tread De th Minimum 9" l 1-1/2" - Pass Dimensional Verification in Accordance with BOCA -1999 Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 7" 7" - Pass Tread Depth Minimum 11" 1I-1/2" - Pass Tread Leading Edge Radius Maximum 1/2" Less than 1/2" - Pass Dimensional Verification in Accordance with IRC - 2003 Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 7-3/4" 7" - Pass Tread Depth Minimum 10" l 1-1/2" - Pass Tread Leading Edge Radius Maximum 9/16" Less than 1/2" - Pass Dimensional Verification in Accordance with Residential Code of New York State, 2002 Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 8-1 /4" 7" - Pass Tread Depth Minimum 9" 11-1/2" - Pass Tread Leading Edge Radius Maximum 9/16" less than 1/2" - Pass 01-37911.04 Page 4 of 6 Test Results: (Continued) Dimensional Verification in Accordance with North Carolina Residential Code. 2002 Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 8- 1/4 7" - Pass Tread Depth Minimum 9" 11-1/2" - Pass Tread Leading Edge Radius Maximum 9/16" Less than 1/2" - Pass Dimensional Verification in Accordance with Florida Buildine Code. 2001 (Revised 2003) Stairway Dimension Requirement Tested Value Width Minimum 36" 38" - Pass Riser Height Maximum 7" 7" - Pass Tread Depth Minimum I1" I 1- 1/2" - Pass Tread Leading Edge Radius Maximum 1/2" Less than 1/2" - Pass Test Results: (Continued) Test 2 - Vertical Load (300 lb treadload over 4 sq. in.) (Test perfotwed on the center of stair tread) 01-37911.04 Page 5 of 6 Load Test Time Deflections (inches) Level' Load (h:m:s) Comments/Observations ) Mid. 0.5 150 2:41p Preload 0.05 _.._......._-....._ Start Load/Deflection 0.2 r._� 60 _......._ 2:43p ---_..... ....... ._.... ..._.—._... 0 _ _----..—.— ............. ...—. 0.4 120 2:45p ..__....... —..... 0.00 _... —.—....... ---._.. 0.6 ..... .................. ... __...-- 180 -- 2:47p -......._...._....._.... __._...._.... _....... — ... ...... .�.....__...._._. 0.00 ... _........-_._... ........ _— ..... _.—_.....-..._.....- _... _._.._._....__—....--.-_-.. _—__..... _......... ....... _.__.......... - ....... _.. 0.8 240 2:49p 0.04 .............. 1.0 -- ---- 300 -......_.__._...... 2:51p _.._-...-........._...__...... ._._..... -....... _.--- 0.09 ....... _........ ..-..-......... ........_... _.. _............ ......_ 1.2 .. r.- _.-._...._. 360 _...... ...... 2:53p -.._............. 0.10 ......_.... _._............. ..... .- ._.... ............. ... - 1.4 _............... --- ---- _ 420 — _. ........—.._ 2:55p ._....... _—._ —...__.__ ...... —. _ .._._ 0.13 — ..... ....... _... _......—.. — —�_.-.............�-.._......._...__.. __... --........ 1.6 480 2:57p -- 0.15 — _- ..... ..._.. ............. 1.8 _........................... .._—_..- -- 540 ..._... ._........ _ ...... 2:59p __............... _ ....... ........_—......._..._.. .._._. 0.17 __._—_._..__.......... ..... _..,.........__...-_.. 2.0 600 _.....__._... _... ........ 3:01p _._.....__.................... _.—......... -_._...._._...... _. 0.18 ... _._................ _.................... - ...... _............ ....... ..... 0.2 60 3:03p 0.03 Final Recovery 2.5 750 3:05p Ultimate Load /BOCA' No Struentral Failure Load Level is ratio oj'test toad to design load. Ultimate Load oj'2.5.r design load is required only when testing to BOCA 01-37911.04 Page 6 of 6 Test Summary: Test 1 - Dimension Verification: The deck structure met all of the listed code requirements for dimensional acceptance. Test 2 - Vertical Load: (300 lb t•eadload over 4 sq. in.) The stair tread achieved the 2x design load as required by code agencies with a recovery of 83%. The stair tread also achieved the 2.5x design load as required by BOCA without structural failure. Photographs of the systems tested, and a copy of this report will be retained by ATI for a period of four years. This report is the exclusive property of the client so named herein and is applicable only to the sample tested. Results obtained are tested values and do not constitute an opinion or endorsement by this laboratory or any of its representatives. This report may not be reproduced, except in fill, without the approval of Architectural Testing. For ARCHITECTURAL TESTING, INC. Dlgiglly Signed hy.Joscph M Bdekner Joseph M.Brickner Technician Digblly Signed by: Joseph A Reed Joseph A. Reed, P.E. Director - Engineering and Product Testing JMB:jadnlb 01-37911.04 �- 2 Digitally Signed IV. Steven M. adch Steven M. Urich, P.E. Senior Project Engineer A TWINING COMPANY TIRADCO,LLP 3220 E.59Ti1 STREET LONG BEACH, CA 90805 Tel (562) 272-7231 March 23, 2018 Fix (562) 529-75 13 www.RADCOinc.com Mr. Marty Johnson Style Crest Inc. 600 Hagerty Drive Fremont, OH 43420 RE: Review ATI test report on fiberglass coated plywood steps for compliance with the most recent code versions Dear Mr. Johnson: We have received the test report you submitted from Architectural Testing (ATI), York, PA. The details are as follows: Report number: 01-37911.04, dated 11/7/03 Title: Step Performance Test Report Products covered: 4-Tread, Dura-Grip II, Step Unit [A five riser, four tread step fabricated with pressure treated lumber and fiberglass]. At your request, we have evaluated the test report against the building codes outlined below. CODE 2015 International Building Code (IBC) Stairway Dimension Requirement Tested Value (2) Compliance Width (1) 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9116" maximum Less than 1/2" Pass CODE 2015 International Residential Code (IRC) Stairway Dimension Requirement Tested Value (2) Compliance Width 36"minimum 38" Pass Riser Height 7-3/4" maximum 7" Pass Tread Depth 10" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass M, bonier r� ouy a6a��S OMH1 moo®u�®s °� ri e�eElabbo of ar..y ...rr,.,a4a.mm. ..." tte `�� ACGPEDfRO � "iNOirv9i�i"iE ra PFA Mr. Marty Johnson Style Crest Inc. March 23, 2018 Page 2 CODE 2017 Florida Building Code (FBC) Stairway Dimension Requirement Tested Value (2) Compliance Width - 36" minimum 38" Pass (1) Riser Height 7" maximum, 4" minimum 7" Pass Tread Depth 11" minimum 11-1/2" Pass Tread Leading Edge Radius 9/16" maximum Less than 1/2" Pass Notes: (1) 44" minimum or 36" if serving an occupant load less than 50. (2) The tested values have been taken from the referenced ATI test report, RADCO has not independently verified any of the actual dimensions, and is not responsible for the accuracy of these dimensions. CONCLUSION: There have either been no changes in the dimensional requirements in the IBC, IRC and the FBC or, as in the case of the Tread Leading Edge Radius, the requirements have been altered minimally, when compared to the requirements listed in the referenced ATI test report number 01-37911.04, dated 11/7/03. The product is therefore in compliance with the dimensional requirements of the editions of the IBC, IRC and the FBC referenced above for the four (4) dimensions shown in the tables. st that this proposal has been responsive to your objectives. Please do not hesitate to call if you have any questions. As always, we look forward to working with Style Crest and to starting this program in the near future. This proposal is valid for 90 days. Sincerely, RADCO Fernando Ardila, Director Testing Laboratories & Materials Evaluation RATect ProjeoWSWecrest or RM=4160A\style crest code verifcation5.wpd REVISIONS _ £ fir;..p 9;!• 1 £ }" - ''I REV DESCRIPTION DATE APPROVED A. INEW D-�A'WING GREAiE Gi 09 2018 .?AINTER D D C C B � B W FV SrYLECRESM BILL OF MATERIAL wTOLERANCES �. ,Q oEC Wes. u�x awWeE ITEM QTY PART NUMBER DESCRIPTION w ".w F°Wwmcmim wxmun`m a'RAIL A55EMBL A 017353838 FG STEP 70-35H--38D-3BVJ Q IGURATION 2 1 0294387 D _'� fkl 4 STEP-3:8 PLA' 35" H y.:.�, S� M. M oh sON 19 15 S TP_RL ASSY p ♦aa 5APRPBT 3 1 02938 " EA` ; RAiI 38" 'MOE 4 3 2 1 Deck and Rail Assembly Test #2 - Setup