STEP PERFORMANCE TEST REPORT
Rendered to:
STYLE CREST MANUFACTURING, INC.
SERIES: 4-Tread, Dura-Grip II, Step Unit
Report No: 01-37911.04
Report Date: 11/07/03
6
Five
130 Derry Court
York, PA 17402-9405
phone: 717.764.7700
fax: 717.764.4129
www.archtest.com
Architectural Testing
STEP PERFORMANCE TEST REPORT
Rendered to:
STYLE CREST MANUFACTURING, INC.
600 Hagerty Drive
P.O. Box 690
Fremont, Ohio 43420
Report No.: 01-37911.04
Test Date: 09/01/00
Report Date: 11/07/03
Project Summary: Architectural Testing, Inc. (ATI) was contracted by Style Crest
Manufacturing, Inc. to conduct structural performance tests on a five riser, four tread and built in
landing, self supporting fiberglass Dura-Grip II, step unit. The system was evaluated for the
design load requirements and dimensional requirements only of the following building codes and
standards:
BOCA-1999 - Building Officials and Code Administrators (Reference ASCE 7-95)
UBC-1997 / ICBO - International Conference of Building Officials
SBC-1997 / SBCCI - Southern Building Code Conference International
International Residential Code, 2000
International Residential Code, 2003
Residential Code of New York State, 2002
Florida Building Code, 2001 (Revised 2003)
North Carolina Residential Code, 2002
Test Specimen (Step Assembly) Description: The step unit was fabricated with a pressure
treated lumber framework and a layer of fiberglass over the entire structure. The step unit was
38" wide and had an overall height of 35". The five risers were each 7" high. The four treads
were each 11-1/2" deep. The landing was 38-1/2" deep to the nosing. The leading edge, tread
radius measured less than 9/16" (see attached photographs for visual clarification of step
structure). The manufacturer provided all components and fasteners comprising the test
specimen.
130 Derry Court
York, PA 17402-9405
phone: 717.764.7700
fax: 717,764.4129
www.archtest.com
01-37911.04
Page 2 of 6
Test Procedures: The following tests were performed on the step structure for the requirements
of each code or standard as referenced.
Tests Conducted:
Stairway dimension verification in accordance with the following:
A) International Residential Code, 2000
B) CABO, 1995
C) Standard Building Code, 1999
D) Uniform Building Code, 1997
E) BOCA, 1999
F) International Residential Code, 2003
G) Residential Code of New York State, 2002
H) North Carolina Residential Code, 2002
1) Florida Building Code, 2001 (Revised 2003)
2. 300 lb treadload over 4 sq. in. (design load) test performed on the center of stair tread.
Loading and Measurement Procedure: The loads were applied to the components of the
system following ATI's Test Procedure. All deflection measurements were taken using
electronic deflection transducers.
Equipment: The components were loaded using a hydraulic press with an electrical load cell for
measurement of each load.
Test Results: The following tables list the results of data collected during testing and compare it
to the appropriate code requirement.
Test 1 - Dimensional Verification in Accordance with IRC - 2000
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 7-3/4"
7" - Pass
Tread Depth
Minimum 10"
I 1-1/2" - Pass
Tread Leading Edge Radius
Maximum 9/16"
less than 1/2" - Pass
Dimensional Verification in Accordance with CABO -1991
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 7-3/4"
7" - Pass
Tread Depth
Minimum 10"
11-1/2" - Pass
Tread Leading Edge Radius
Maximum 9/16"
less than 1/2" - Pass
01-37911.04
Page 3 of 6
Test Results: (Continued)
Dimensional Verification in Accordance with SBC -1999
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 7-3/4"
7" - Pass
Tread Depth
Minimum 10"
11-1/2" - Pass
Dimensional Verification in Accordance with UBC - 1997
Stairway Dimension
Requirement
Tested Value
Width ,
Minimum 36"
38" - Pass
Riser Height
Maximum 8"
7" - Pass
Tread De th
Minimum 9"
l 1-1/2" - Pass
Dimensional Verification in Accordance with BOCA -1999
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 7"
7" - Pass
Tread Depth
Minimum 11"
1I-1/2" - Pass
Tread Leading Edge Radius
Maximum 1/2"
Less than 1/2" - Pass
Dimensional Verification in Accordance with IRC - 2003
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 7-3/4"
7" - Pass
Tread Depth
Minimum 10"
l 1-1/2" - Pass
Tread Leading Edge Radius
Maximum 9/16"
Less than 1/2" - Pass
Dimensional Verification in Accordance with Residential Code of New York State, 2002
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 8-1 /4"
7" - Pass
Tread Depth
Minimum 9"
11-1/2" - Pass
Tread Leading Edge Radius
Maximum 9/16"
less than 1/2" - Pass
01-37911.04
Page 4 of 6
Test Results: (Continued)
Dimensional Verification in Accordance with North Carolina Residential Code. 2002
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 8- 1/4
7" - Pass
Tread Depth
Minimum 9"
11-1/2" - Pass
Tread Leading Edge Radius
Maximum 9/16"
Less than 1/2" - Pass
Dimensional Verification in Accordance with Florida Buildine Code. 2001 (Revised 2003)
Stairway Dimension
Requirement
Tested Value
Width
Minimum 36"
38" - Pass
Riser Height
Maximum 7"
7" - Pass
Tread Depth
Minimum I1"
I 1- 1/2" - Pass
Tread Leading Edge Radius
Maximum 1/2"
Less than 1/2" - Pass
Test Results: (Continued)
Test 2 - Vertical Load
(300 lb treadload over 4 sq. in.)
(Test perfotwed on the center of stair tread)
01-37911.04
Page 5 of 6
Load
Test
Time
Deflections (inches)
Level'
Load
(h:m:s)
Comments/Observations
)
Mid.
0.5
150
2:41p
Preload
0.05
_.._......._-....._
Start Load/Deflection
0.2
r._�
60
_......._
2:43p
---_..... ....... ._.... ..._.—._...
0
_ _----..—.— ............. ...—.
0.4
120
2:45p
..__....... —.....
0.00
_... —.—....... ---._..
0.6
..... .................. ... __...--
180
--
2:47p
-......._...._....._....
__._...._.... _....... — ... ...... .�.....__...._._.
0.00
... _........-_._... ........ _— ..... _.—_.....-..._.....-
_... _._.._._....__—....--.-_-..
_—__..... _......... ....... _.__.......... - ....... _..
0.8
240
2:49p
0.04
..............
1.0
-- ----
300
-......_.__._......
2:51p
_.._-...-........._...__...... ._._..... -....... _.---
0.09
....... _........ ..-..-......... ........_... _..
_............ ......_
1.2
.. r.- _.-._...._.
360
_...... ......
2:53p
-.._.............
0.10
......_.... _._............. ..... .-
._.... ............. ... -
1.4
_...............
--- ---- _
420
— _.
........—.._
2:55p
._....... _—._
—...__.__ ...... —. _ .._._
0.13
— ..... ....... _... _......—.. —
—�_.-.............�-.._......._...__..
__... --........
1.6
480
2:57p
--
0.15
— _- ..... ..._..
.............
1.8
_...........................
.._—_..- --
540
..._...
._........ _ ......
2:59p
__............... _ ....... ........_—......._..._.. .._._.
0.17
__._—_._..__.......... ..... _..,.........__...-_..
2.0
600
_.....__._... _... ........
3:01p
_._.....__.................... _.—......... -_._...._._...... _.
0.18
... _._................ _.................... - ...... _............ ....... .....
0.2
60
3:03p
0.03
Final Recovery
2.5
750
3:05p
Ultimate Load /BOCA' No Struentral Failure
Load Level is ratio oj'test toad to design load.
Ultimate Load oj'2.5.r design load is required only when testing to BOCA
01-37911.04
Page 6 of 6
Test Summary:
Test 1 - Dimension Verification: The deck structure met all of the listed code requirements
for dimensional acceptance.
Test 2 - Vertical Load: (300 lb t•eadload over 4 sq. in.) The stair tread achieved the 2x
design load as required by code agencies with a recovery of 83%. The stair tread also
achieved the 2.5x design load as required by BOCA without structural failure.
Photographs of the systems tested, and a copy of this report will be retained by ATI for a period
of four years. This report is the exclusive property of the client so named herein and is
applicable only to the sample tested. Results obtained are tested values and do not constitute an
opinion or endorsement by this laboratory or any of its representatives. This report may not be
reproduced, except in fill, without the approval of Architectural Testing.
For ARCHITECTURAL TESTING, INC.
Dlgiglly Signed hy.Joscph M Bdekner
Joseph M.Brickner
Technician
Digblly Signed by: Joseph A Reed
Joseph A. Reed, P.E.
Director - Engineering and Product Testing
JMB:jadnlb
01-37911.04
�- 2
Digitally Signed IV. Steven M. adch
Steven M. Urich, P.E.
Senior Project Engineer
A TWINING COMPANY
TIRADCO,LLP
3220 E.59Ti1 STREET
LONG BEACH, CA 90805
Tel (562) 272-7231
March 23, 2018
Fix (562) 529-75 13
www.RADCOinc.com
Mr. Marty Johnson
Style Crest Inc.
600 Hagerty Drive
Fremont, OH 43420
RE: Review ATI test report on fiberglass coated plywood steps for
compliance with the most recent code versions
Dear Mr. Johnson:
We have received the test report you submitted from Architectural Testing (ATI), York, PA. The details
are as follows:
Report number: 01-37911.04, dated 11/7/03
Title: Step Performance Test Report
Products covered: 4-Tread, Dura-Grip II, Step Unit [A five riser, four tread step fabricated with
pressure treated lumber and fiberglass].
At your request, we have evaluated the test report against the building codes outlined below.
CODE
2015 International Building Code (IBC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width (1)
36" minimum
38"
Pass (1)
Riser Height
7" maximum, 4" minimum
7"
Pass
Tread Depth
11" minimum
11-1/2"
Pass
Tread Leading Edge Radius
9116" maximum
Less than 1/2"
Pass
CODE
2015 International Residential Code (IRC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
36"minimum
38"
Pass
Riser Height
7-3/4" maximum
7"
Pass
Tread Depth
10" minimum
11-1/2"
Pass
Tread Leading Edge Radius
9/16" maximum
Less than 1/2"
Pass
M, bonier r� ouy
a6a��S OMH1 moo®u�®s °� ri
e�eElabbo of ar..y ...rr,.,a4a.mm. ..."
tte `�� ACGPEDfRO � "iNOirv9i�i"iE ra PFA
Mr. Marty Johnson
Style Crest Inc.
March 23, 2018
Page 2
CODE
2017 Florida Building Code (FBC)
Stairway Dimension
Requirement
Tested Value (2)
Compliance
Width
- 36" minimum
38"
Pass (1)
Riser Height
7" maximum, 4" minimum
7"
Pass
Tread Depth
11" minimum
11-1/2"
Pass
Tread Leading Edge Radius
9/16" maximum
Less than 1/2"
Pass
Notes: (1) 44" minimum or 36" if serving an occupant load less than 50.
(2) The tested values have been taken from the referenced ATI test report, RADCO
has not independently verified any of the actual dimensions, and is not responsible for
the accuracy of these dimensions.
CONCLUSION:
There have either been no changes in the dimensional requirements in the IBC, IRC and the FBC or,
as in the case of the Tread Leading Edge Radius, the requirements have been altered minimally, when
compared to the requirements listed in the referenced ATI test report number 01-37911.04, dated
11/7/03. The product is therefore in compliance with the dimensional requirements of the editions of
the IBC, IRC and the FBC referenced above for the four (4) dimensions shown in the tables.
st that this proposal has been responsive to your objectives. Please do not hesitate to call if you have
any questions. As always, we look forward to working with Style Crest and to starting this program in
the near future. This proposal is valid for 90 days.
Sincerely,
RADCO
Fernando Ardila, Director
Testing Laboratories & Materials Evaluation
RATect ProjeoWSWecrest or RM=4160A\style crest code verifcation5.wpd
REVISIONS
_
£ fir;..p 9;!• 1 £ }" - ''I REV DESCRIPTION DATE APPROVED
A. INEW D-�A'WING GREAiE Gi 09 2018 .?AINTER
D
D
C
C
B
�
B
W FV
SrYLECRESM
BILL OF MATERIAL wTOLERANCES
�.
,Q
oEC Wes. u�x awWeE
ITEM QTY PART NUMBER DESCRIPTION w ".w F°Wwmcmim wxmun`m a'RAIL A55EMBL
A
017353838 FG STEP 70-35H--38D-3BVJ Q
IGURATION
2 1 0294387 D _'� fkl 4 STEP-3:8 PLA' 35" H y.:.�, S� M. M oh sON 19 15 S TP_RL ASSY p
♦aa 5APRPBT
3 1 02938 " EA` ; RAiI 38" 'MOE
4 3 2 1
Deck and Rail Assembly
Test #2 - Setup