HomeMy WebLinkAboutRevision; Corrected Product Approval OFFICE USE ONLY: FILE COPY
DATE FILED: r PERMIT# 2002-0309
REVISION FEE: RECEIPT# I ^
,J7
Y PLANNING& DEVELOPMENT SERVICES
COU N Ty BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
_ _O _D_ FORT PIERCE,FL 34982-5652
(772)462-1553 FAX(772)462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCAT
ADDRESS:ION/SESOTO
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CORRECTED PRODUCT APPROVAL TO SHOW UPDATED IMPACT WINDOW
MODEL NUMBER
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#: 8898
BUSINESS NAME: Wynne Buildingorpora ion
QUALIFIERS NAMEb South U Suite ADDRESS: 8 UO wy.
CITY; Fort St. Lucie STATE: ZIP:
PHONE(DAYTIME): - FAX: 772) 878-7656
4. OWNEWBUILDER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: 8000 SouthHwy. I Suite 402
CITY: STATE: FL ZIP: 34952
PHONE: (772) 878-5513 FAX: (772) 878-7656
5. ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN&BRADEN
ADDRESS: 417 COCONUTAVE.
CITY: STUART STATE: FL ZIP: 34996
PHONE(DAYTIME): (772)287-825.8_— __ FAX:
L :
Revised 07/22/2014
l
JUN O'1 2020
Permitting `� ar�j���nt
e
0 PY
F1 LE L,
St. Lucie County Bldg Dept
5-14-20NIB '
ffniWynne Development
c,E;
Permit No:
A00;-030q
Address
BRADEN & BRADEN, A. I. A., P. A. J
To whom It may concern,
® FOH hes is wynneem delseshowing uct the approval
rpev revised for
numbers
-qrchltec"s & nllam r E COMPLIA�,g�y
�� -If you hav questions please feel free to call me
417 COCONUT AVENUE, STUART, FLORIOA 34 T' ClE COU � at T38"
TELEPHONE: (772) 2B7-B25B FAX(772) 2B7-8283 (��/(/�/ CJILen
#AAC-000032
- Braden t Braden /
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows dr Skylights TT
Opening NOA/FL Product Model # Manufacturer Glass Attachment method Expiration Design Pressure
Type NUMBER bb Date of Approved Tests
1,2,3 FLtt 239.9 Single Hung SH-1100A 5/16" spacedia.per proodduct a approval. Contreeto hal edhare to
E 4Vima t PGT noun. edge distances specified in Product approval -80.0 PS
Overhead Model 824/811 a. `vert air x�6-UTF °"`N"fisc aw... ..:c r aG + 50.0/-60.0 of
A 16-0330.02 W-0 max. width DAB , „i and"" „�b 10-9-21 p
Garage Door IL'-O' max height m a ta',sdy aa.c.-oc to a&—to V.Jct sppw
Design Pro/ Elco 1/4' dia. tapcon with min 1.75' embedment at 3' max
B FLU 16614.1 Fiberglass Smoth Pro Jeld-Wen from corners and 11.5' o.c. max thereafter in head and ,lambs. + 50.0 PSF
Slidin Glass Series 110 I" nom 1/4' die. topcons w/ nun. 1 3/4' penetration to be
C FLU 251.4 g SGD PGT spaced per product approval. Contractor shall adhere to ± 60.0 PSF
Door Type "GSA" sun. 2 I/2' a ge distances apecdied in Product approval RN
Product NOA/FL Model # Manufacturer Attachment Method Expiration Design Pressure
NUMBER Date of Approved Tests
MullionsInatell per fastener typo and racing shown in Table IA and IB _
FLU 241.1 1' x 2 3/4' x.315' PGT in product approval on sheet racing
72. + 58.0 PSF
Roof 5V Crimp 2L ga. 5v crimp metal roofing attached to plgwood dock using a9 x 1.5'
FLtt 11451.12 Metal Roof,nGulf Coast Supply w screws with self sealing washer at 12' o.c. max spacing over ASTM D
g and manufacturing (type 2) 30 Ib felt underlagment installed wth min. 4 side laps and L' and
laps fastened with corrosion resistant tin caps and with 1.25' ring shank nail - 108.5 PSF
spaced L' o.c. at all laps and two ate Barad rows 12" o.c. in field. Attach
eck to trusses using attachment dace,, on roof plan
Siding Stucco on Block
Model T4 12" vented Install using 2' x 2" battens at L' o.c. screwed to soffit framing using +55.0/-35.0 PSF
Soffit FLU 12198.3 Vinyl Soffit Kagean tt8 x 3' wood ;crews at each trues. Install soffit tc battens using
nails with 3/8" dia. d-
Hurricane
Panels
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )