Certification for Design Load Compliance
Project Name: Screened In Porch
Project Address: 3436 Roselawn Blvd.
Permit #:1910-0239 Occupancy Type: R-3 Construction Type: V
RECEIVED
DEC 10 7019
Permitting Department
St. Lucie Count'!
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building (Res) Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed X Partially Enclosed _Open
3. Risk Category:_I X II _III IV Exposure Category:_B X C _D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width:4 ft
5. Mean Roof Height 15 ft Roof Pitch: 3 :12 Parapet:- ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -41.2 Zone 2: -63.8 Zone 3: "63.8 Zone 4: +44.01-46.8 Zone 5: +44.01-55.3 Garage: -
7. Design Loads: Floor:" PSF Roof/Dead:15 PSF Roof/Live:20 Balcony: PSF
Dock:- PSF Deck:" PSF Stairs:" PSF Fence:" PSF Railings:" PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure:1500 PSF Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces s��ql f l:l I I //// y
J; td7gs/%
Brian Maskol, PE 66080 30881
\� �,. �yCENSF'.• `
Print Name Cert # & Co. Cert Auth.
0 ',
Summit Design & Forensics, Inc.
*
— �—�'c �L2.3 • LEI_
gr'�f�re, fS�4L�laSeal;
\
725 SE Port St. Lucie Blvd., Suite 203, Part St Lucie, Florida 34984