Loading...
HomeMy WebLinkAboutCertification for Design Load Complianceu f 4 1 1 �n'r= Planning& Development Services Department • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 i Certification for Design Load Compliance Project Name: Wade Jurney Homes -1612 Project Address: 6504 Santa Clara Blvd Permit#: Occupancy Type: Construction INSTRUCTIONS FOR USE: - • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition FILE C®Py o Any accessory structure requiring a building permit Ef o Any non-residential structure. * Note: Farm not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X II _lll_IV Exposure Category:B X C _D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3•6 ft 5. Mean Roof Height 11 Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +19.3,-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3, 78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,44.8 Garage: +31.7/-38.6 7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A - PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? Y Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces spe00%I II111??, \\\\\ is G. P ,,; // James G. Friling �Q�.•V�CEfYBF 'iyts % Print Name Cert # & Co. Cart Auth. * * _ PE #77824 COA #27228 Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002 Company Name & Address APR 1 1 ZU14