Loading...
HomeMy WebLinkAboutProduct Evaluation Report - Silver Line Windows & DoorsBUILDING DROPS 12 A Perfect Solution in Every Drop Certificate of Authorization: 29578 Product Evaluation Report RECEIVED) Of MAR 11 'I.020 Silver Line Windows & Doors L Lucla coun N, r®ffnlurin0 Series 70 Casement Window ----- Non -Impact Rated for Florida Product Approval FL# F'L21335t a, Report No. 5245 Current Florida Building Code Method: Category: Sub — Category: Product: Material: Product Dimensions: 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com 1 — D (Engineering Evaluation) Windows Casement Series 70 Casement Window PVC See Installation Instructions SWD047 Prepared for: Silver Line Building Products One Silverline Dr. North Brunswick, NJ 08902 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 12/15/2017 Contents: Evaluation Report Pages 1 —5 Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2017,12.18 11:06:30-05'00' �„e `t u u GYM s F. O 7 v •..........• Hermesrll!1Jklkro0, P.E. Florida No. 73778 /(2BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Silver Line Windows & Doors Product Category: Product Sub -Category: Compliance Method: Product Name: Windows Casement State Product Approval Method (1)(d) Series 70 Casement Window Non -Impact Rated FL#: FL21335 Date: 12/15/2017 Report No: 5245 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Windows & Doors based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission.. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD047, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, excluding the "High Velocity Hurricane Zone' (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD047 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWD007 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 5 BUILDING DROPS FL#: FL21335 - A Perfect Solution in Every Drop! Date: 1 Certificate of Authorization: 29578 Report Noo:: 55245 45 Certification Agency: The manufacturer has demonstrated compliance of window products in accordance with the Florida Building Code and State Rules for manufacturing under a Certification Agency through Window and Door Manufacturers Association (FBC Organization #: CER1508). Performance Standards: The product described herein has been tested per: Referenced Data: • AAMA/WDMA/CSA 101/I.S.2/A440-11 1. Product Testing performed by Architectural Testing (FBC Organization # TST1558) Report: Dated: C4226.01-109-47 02/01/13 D8520.01-109-47 10/09/14 D5515.01-109-47 10/09/14 D6237.01-109-47 09/18/14 D7158.01-109-47 10/29/14 F2254.01-109-47 02/19/16 2. Certification Agency Window and Door Manufacturers Association (FBC Organization #: CER1508) 3. Material Certification PVC profiles meet requirements of WDMA/Hal]Mark WD-61 in accordance with AAMA 303 Hermes F. Norero, P.E. Florida No: 73778 Page 3 of 5 IQBUILDING DROPS A Perfect Solution in Every Dropl Certificate of Authorization: 29578 Installation: 1. Approved anchor types and substrates areas follows: Through Frame Installation: FL#: FL21335 Date: 12/15/2017 Report No: 5245 A. For two by (2X) wood buck substrate (Min. S.G. = 0.55), use #20 PH Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete (Min. fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where one by (1X), non-structural, wood bucking is employed, OR where wood bucking is NOT employed, use 3/16" diameter ITW HWH Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel stud substrate (Min 18 Ga., Fy = 33 ksi), use #10 Grade 5 Self -Drilling or Self - Tapping PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. D. For aluminum substrate (Min 1/8", 6063-T5), use #10 Grade 5 Self -Drilling or Self - Tapping PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Nail Fin Installation: A. For two by (2X) wood buck substrate (Min. S.G. = 0.55), use #8 PH Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For steel stud substrate (Min 18 Ga., Fy = 33 ksi), use #8 Grade 5 Self -Drilling or Self - Tapping PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. C. For aluminum substrate (Min 1/8", 6063-T5), use #8 Grade 5 Self -Drilling or Self -Tapping PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Refer to Installation Instructions (SWD047) for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 5 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Design Pressure: FL#: FL21335 Date: 12/15/2017 Report No: 5245 Referto Installation Instructions (SWD047) for Overall Size and design Pressure and more details of the Products. Hermes F. Norero, P.E. Florida No. 73778 Page 5 of 5 SILVER LINE BUILDING PRODUCTS V3 SERIES170 SERIES CASEMENT WINDOWS (70) GENERALNOTFS: 1. THE PRODUCT SHOWN HEREIN O DESIGNED AND MANUFACTUREDTO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC), EXCLUDING HVHZANO HAS BEEN EVALUATED ACCORDING TOME FOLLOWING: • AAMA/WDMA/CSA 1D1/1S.2/A440-11 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, U FRAMING, AND METAL FRAMING ASA MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS ME RESPONSIBILITY OFTHE ENGINEER OR ARCHITECT OF RECORD MR ME PROJECT OF INSTALLATION. 3. IX AND U BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION ISTHE RESPONSIBILITY OF THE ENGINEER OR ARCHITECTOF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF STIR CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETARED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH US DOCUMENT IN NON-HVHZARFAS. S. APPROVED IMPACT PROTEMMVESYSTEM B REQUIRED ON 6. WINDOWFUMEMATERIAUPVC ]. GIASSMEETSWEREQUIREMENTOFASTME1300 GLASS CHARTS. SEESHEET 1 FOR GWNG DETAILS. PRODUCE OVERALLSIIE DESIGN INSTALLATION MISSILEIMPACT GLASS TABLE OF CONTENT WIDTH HEIGHT SHEET REVISION SHEETDESCRIPTION MODEL PRESSURE METHOD RATING TYPE 70NMI 36" 1. *30/-30 PSF NAILFIN NOWIMPACT G2 1 - GENERAL NOTES &SWING DETAIL 2 - ELEVATION & ANCHOR LAYOUT ]ORCWI 36' )2' ♦30/-30 PSF THROUGH FUME NOWIMPACT G2 3 - ELEVATION & ANCHOR LAYOUTS 70NCW3 36' 72' K0/-50 PSF NAIL GIN NON -IMPACT GI 4 - ELEVATION&ANCHOR LAYOUTS S - ELEVATION &ANCHOR LAYOUTS 70RCW1 36' 72- +SO/ -SO PSF THROUGH NON -IMPACT GI 6 - VERTICALSECTIONS FUME 7 - HORIZONTALSECTIONS 70NM R° 1. H0/-30 PSF NAILFIN NON -IMPACT G2 VERTICAL&HORIZONTAL NOTES& e - ORCEMAITDETAHLIATION REINFORCEMENTDCTAILS 70RCW2 ]2° J2° s30/-30 PSF TFRUOME NON -IMPACT G2 G2 GI 3/4° O.A. INSULATED GLASS 3/4" OA INSULATED GLASS CONSISTINGOR CONSISTING OF: GLASS, I 1/8°ANNEALED GLASS,9/16°AIRSPACE, 1/2'MR SPACE, 70NCW2 Sr SO° °SO/-50 PSF NAILFIN NON -IMPACT G1 70RCW2 52" 50" 450/-50 PSF THROUGH FUME3/327ANNEALED NOWIMPACT GI 70NM 78' 50' •50/-SO PSF NAILFIN NON -IMPACT GS 3/32°ANNEALED GLASS _ 1/8°ANNEALED GLASS I S \ 70RCW3 70' S0' ♦50/-50 PSF THROUGH NON -IMPACT GS FUME EXTERIOR / INTERIOR / 70NCW3 108' 7T +30/-30 PSF NAILFIN NON -IMPACT G2 ( I 4 I'-L 70RCW3 low 72- ♦30/-30 PSF THROUGH NON -IMPACT G2 FUME TIN COATED STEEL LJ 70NCW4 SOS' 72' +30/-30 PSF NAILRN NONHMPACT G2• INTERCEPTSPACER \ MIN.GIASS i BITE 1/2- 1/8°SETTING BLOCK 70RCN4 low1. ♦30/-30 PSF THROUGH NOWIMPACT 52• GFRAME LAZING DETAIL DOW HOT 70NMPW 84- 1. .30/.30 PSF NAILFIN NON -IMPACT GI&G2- INSTANTGLAZEIII 7ORCWPW 1. 72" ♦301-30 PSF THROUGH NOWIMPACT G1&G2• NOTE: FRAME 1. ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH SAFETY GLAZING REQUIREMENTS OUTLINED IN 70NCPC3 108° 72' ♦30/-30 PSF NAILFIN NON -IMPACT G38G2• CURRENT FBCAND ASTM E 1300 GLASS LOAD RESISTANCE. 2. SETTING BLOCK SHOULD BE 7D-90 DUROMETERAS PER 70RCPC3 108' 72• ♦30/-30 PSF THROUGH NON -IMPACT G3&G2• FUME CH 24 OF THE CURRENT FBC. 3. GLASS LITES THAT EXCEED 36' IN WIDTH SHALL USE SETTING BLOCKS AT} SPAN FROM CORNERS, NOTE: FOR 70NUO S, 70RCPC3 USE GI FOR FIXED LITE & G2 FOR OPERABfE5A5H SilverLine MAMersen PxC RY[NPITOPJVF xomx4nuxrxlocwm}m [Ol ]y1E}B Z W z-� C �y io W Nog= allE_B C3 �� Yma m 2 w /a � u v S A OF o 0 IDP.+ Wes: 0 ]iuFSAl q�aub!ait nT}e m c w}°pp°10u � sw. m nrt mx: 6v u}�maeu.>!a°� aesre FL4: FL21335 DATE: 10.16.17 DWG. BY: CHK. BY: RV I HFN SCALE: NTS DWG.u: SWD047 SHEET IOF 8 ANCHOR LAYOUT FINLESS DP +/- 30 PSF CASEMENT ELEVATION 4- MAX. FROM CORNER 1 91/4"O.C.-T •X" MAX ANCHOR LAYOUT FINLESS DP +/- 50 PSF 11- 0 2-FROM CORNER G MAX ANCHOR LAYOUT (DP+/- 30 OR 50 PSF) Silver Line b,And&kn axss¢vewxEorm xorzm xwrano�woamx �x+a 2 z5 „O <o o;�E x Q w N 6 \a 1 K 9 �p SA OF ; K 2 �nFw#oE e�amm°vms w iGE04N W/.OI aq �3Y xNM �M. M1 YYi iR RF4 V Wx140uTM b Af]f FL#: FL21335 DATE: 10.16.17 owGRV EH HFN SCALE: NTS Owc.#: SWD047 SHEET 2 OF 8 Y, VENTMAX WIDTH108- WIDTH 3437S' OLD MAX A B WIDTH 395" fi fi FRAME G D E H HEIGM ) ) T J "X" "X"OR"O" 'X° VENT MAX HEIGHTJO" D.LO. MAX HEIGHTGS° J TRIPLE CASEMENT ELEVATION L 8' MAX r FROM CORNER 18 3/4" O.C. MAX �FROMCORNER MAX °X" D "X'ON"O" ANCHOR LAYOUT FINLESS DP +/- 30 PSF AAK J3° NOTE: ANCHORSPAONG SPECIFICATIONS BELOW APPLY FOR THE DOUBLE ANDTRIPLE CASEMENT CONFIGURATIONS MA orlon n^ MAX WIDTIDT H 34.3]S° A efi fiDLO MAX. WIDTH 39.5°FRAME - E HEIGHI ) ) "X" °X, VENTMAX HEIGHT70" G D D.LO. MAX HEIGHT 65' DOUBLE CASEMENT ELEVATION ANCHOR LAYOUT DP+/- 30 PSF SilverLine 6YAl14Ct5Bn Lu ME SRVEIWXE OM'F No MBN MW WMXEE X� BRi 331d336 2 z3 � W 64 PEI AAX �� ao zy��3t o�a_^ OS U'm`gY3 SeSa z3 FN: 3'� W3 m C w W N i a F SI IA-6 I`8CE)M0N I AB IIO16ID1 SIAFu6K . `ouei aeoi Emc o-xr, v wnAmA FL p: FL21335 DATE: l n_l ii_1 % SCALE: DWG. a: 3 OF 8 TRIPLE CASEMENT ELEVATION 3" MAX. FROM r CORNER 32" O.C. MAX 3" MAX. FROM CORNER "x" IIIIII °r IIIIII ^X" ANCHOR LAYOUT FINLESS DP +/- 50 PSF NOTE: ANCHORSPACING SPECIFICATIONS BELOW APPLY FOR THE DOUBLE AND TNPIF CASEMENT CONFIGURATIONS G.5"1 DOUBLE CASEMENT ELEVATION ANCHOR LAYOUT DP +/- 50 PSF Silver Line MAndersen oxemvBwxeovrc XOBIXBw16WIOfH1(®SB3 W1' bi 3301IIB i �o n,.0 p am^5 NAX. N i g SD" W� Q ND i _3 m x w N Q a F OF aw B oBwi. eBew aw m f6VE � TT �R1XY1 MSMs'd810 FL#: FL21335 DATE: 10.1617 SCAIE: DWG.#: 4 OF 8 8" MAX FROM CORNER is: A' MGY LIFROM CORNER �oaMA)L X. •X•OR"O" °X"OR"O" X. /4' O.C. HAX T ANCHOR LAYOUT FINLESS DP+/-30 PSF FOUR CASEMENT ELEVATION NOTE: ANCHOR SPACING SPECIFICATIONS BELOW APPLY FOR THE DOUBLE AND TRIPLE CASEMENT CONFIGURATIONS AT CORNERS 12" O.C. MAX �11' O.C. MAX. "X" "X°OR°0' "X"OR"0" X. ANCHOR LAYOUT FIN DP+/- 30 PSF Silver Line hAndersen oxEs¢KBNYEOM'E xomxaxumvnamimvE Nd]3B V Z Zn 'e3 F;c z sH "-1 ..3 Cz Wa �m� W 3 m C w N i a c OF p a� �oAu ab tia�m�� vavBnx xe mTe FL N: FL21335 DATE: 10.16.17 DWG.BY: CHL BY: RV HFN STALE: NTS DwG.a: SWD047 SHEET p 5 OF 8 N FR HE 6 VERTICAL SECTION THROUGH FRAME INSTALLATION NOTE: 1. NAIL FIN INSTALLATION MAY USE OPTIONALL.CHANNEL SUCH THAT TYPICAL INSTALLATION METHODS AND ANCHOR REQUIREMENTS ARE MET. 2. THROUGH FRAME INSTALLATION MAY USE AN OFTIONALSNAP ON FLANGE SUCH THAT TYPICAL NOTE: 1%WOOD BUCK BY OTHERS IS OPTIONAL FOR MASONRY APPLICATIONS. MAIL MAX MM. EXTERIOR FRAME PANEL D.L.O. HEIGHT HEIGHT HEIGHT SEE GLAZING DETAIL, SHEET 1 INTERIOR SEEGLAZING DETAIL, SHEET 1 SilverLine IyAl�pj�, oxesxvEwxeourE xomx exuxivngwmsm G SA OF i11 T O ���6iinFomi�di flM�1 PL Xe 9Y8M � tM NG LPMOIUIe,�W RM ]l9 li{ 0fC V .VIII�Ow/.IM Mc IDS)! FLp: FL21335 6 VERTICAL SECTION rA TE NAILFIN INSTALLATION 6 OF 8 INTERIOR 4 HORIZONTAL SECTION HORIZONTAL SECTION THROUGH FRAMEINSTAILATION 7 INTERMEDIATEJAMBXOX NOTE: L. NAIL FIN INSTALLATION MAY USE OPTIONALI.CHANNELSUCH THAT TYPICAL INSTALLATION METHODS AND ANCHOR REQUIREMENTS ARE MET. ]. THROUGH FRAME INSTALLATION MAY USE AN OPTIONAL SNAP ON [E1 HORIZONTAL SECTION THROUGH FRAME INSTALLATION NOTE:IX WODO BUCK BY OTHERS IS OPTIONAL FOR MASONRY APPLICATIONS. HORIZONTAL SECTION HORIZONTAL SECTION HORIZONTAL SECTION NAIL FIN INSTALLATION 7 INTERMEDIATEJAMBXXX 7 NAIL FININSTALLATION Silver Line hArKW M_n OwxRKXxXE�M/E xomxxxixrmq wceroi xxuae Z uz. W ^ yqW o gi�py(,��� OG^_GS h as I :. W3 r' 2z3�3:�I W3 � mmw 2 N w ¢ a uE� F � 6 n �v 0 �P SA OF ;K i O.Y, '','�Yi oilX n FauA1JE'x ``; IWI®1VL � 9] 44i1 ffW%p aq X SID 1PR 04 T Nw0w11xN xn 8�]! FLk: FL21335 DATE: 10.16.17 DWG. BY: UK. BY: RV I HFN STALF NTS DWG.X: SWD047 SHEET 7 OF 8 D SUBSTRATE MIN. �BY OTHERS EDGE DISTANCE EXTERIOR W INTERIOR VERTICAL SECTION THROUGH FRAME(HEAD,SILL&JAMB) INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EAOHANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED ISTHE MINIMUM NUMBER OFANCHO0.5 TO BE USED FOR PRODUCE INSTALLATION OF1HE MAXIMUM SIZE LLSTED. 3. INSTALL INDMDUAL INSTALLATION ANCHORS WITHIN ATOIERANCE OF 32/2 INCH THE DEPICTED LOCATION &SPACING IN THE ANCHOR LAYOUT DETAILS D.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEKT. 4. SHIM AS REQUIRED AT UCH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 318INCH. SHIM WHERE SPACE OF 1/16INCH OR GREATER OCCUflS, SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENS" PLASTIC OR BETTER. S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT UMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 6. INSTALLATION ANCHORS AND ASSOOATED HARDWARE MUST BE MADE OF CORROSION RESISEANT MATERIAL OR HAVEACORROSION RESISTANT COATING. 7. FOR MASONRY OR CONCRETE OPENINGS,A MWOOD BUCK MAYBE USED (OPTIONAL) AS LONG ASTHE MINIMUM EMBEDMENTAND EDGE DISTANCE REQUIREMENTS ARE STILL METWITHINTHE CORRESPONDING HOST SUBSTRATE. SEE GENERAL NOTE93 ON SHEET 1 FOR MORE INFORMATION. S. FOR HOLLOW BLOC(AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR10INT I. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF RLOCKOR EDGE OF MORTAR JOINT INTO FACESHELL OF BLOCK. 9. INSTALIATIONANCHORSSNALLSEINSTAILEDINACCORDANCEWTMANMOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SIJALLNOT BE WITH USED IN SUBSTRATES STRENGTHS LESSTHAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. Silver Line hAMersen 1/4e MAX. INTERIOR �. SHIMSPACE n3 3 SEE GIAZING 1 SEE GIADNG SUBSTRATE INTERIOR BY OTHERS DETAILSHEETIDETAILSHEET1� oxss¢vEwxEDanE xoat�eax'sm�rulDWl m 1 3EB ~ � U — MIN. EMBEDMENT w ;x a Q 9A oily EXTERIOR �NQD� m3o� os5 z-s'SI Oil �X MIN. o o�'ao �2 L ja EXTERIOR EDGE DISTANCE F � w HORINTALSECTION HORIZONTAL SECTION m `/ d \o NAIL FIN IHEAD,SRL&JAMB) $ REINFORCED MULLION REMARKS BY I DATE A-61HFIXEDRIDN 1AFiTIRISI vnwuixx m:®9 nmi�wc LI" XSj w�ro4wmxa4xr�iaw INTERMEDIATE O JAMB LIIIFFX0 Ft",11'o REINFORCEMENT ,````L REINFORCEMENT DETAIL - r N• .p0! 7 ?9 S A OF r �e RAILFIN T. m `oua aiu�i. �a°m� ¢14 194 mif. V /.MlmLaIXH M Rtfe FL R: FL21335 DATE: 10.16.17 DWG. BY: CHK.BY: RV HFN SCALE: NTS DWG.R: SWD047 5HEET aOF 8 0