HomeMy WebLinkAboutNotice of Product CertificationNOTICE OF PRODUCT CER
TIFICATION
Company: Masonite International CoEiVEp Certification No.: NI013747
1955 Powis Road Certification Date: 06/08/2017
West Chicago, IL 60185j 70�0 Expiration Date: 06/30/2021
41 W,/ Product: Wood -Edge Steel Opaque Ins iYs)9artg��lg w/Non-Impact Rated Sidelites
(iv/Wood Frame unless noted)
Specification: TAS 201/202/203-94
Impact: Large Missile Impact Rated Non -Impact Glazing: Insulating Glass (Tempered)
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification
label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within
NAMI's Certified Product Listing at www.Namicertiriication.com. NAMI's Certification Prnpram is accredited by The American Natinnal Standards Insfitsrte (ANSI)_
Inswing
Glazed
Structural
Water
Missile
Test Report Number
Configuration
or
or
Maximum
Design
Test
Impact
Drawing Number &
Outswing
Opaque
Size
Pressure
Pressure
Rated
Comments
X
I/S
Opaque
3'0" x 6'8"
+70/-70
0.0 psf
Yes
ATLNC 1001.01-13
Single
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
X
O/S
Opaque
3'0" x 6'8"
+7000
3.0 psF
Yes
ATLNC 1001,01-13
Single
4.5 psf'
Maximum Panel Size: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
XX
I/S
Opaque
6'0" x 6'8"
+551-55
0 psf
Yes
NCTL-210-2930-1
Double
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
XX
O/S
Opaque
6'0" x 6'8"
+551-55
3.0 psf
Yes
NCTL-210-2930-1
Double
4.5 psf'
Maximum Panel Size: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
XO/OX
I/S
Opaque Door
6'0" x 6'8"
+551-55
0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelite
Glazed Sidelite
Sidelite-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Dctails-DWG-MA-FL0211-17
XO/OX
O/S
Opaque Door
6'0" x 6'8"
+55/-55
3.0 psF
Door -Yes
NCTL-210-2930-1
Single w/Sidelite
Glazed Sidelite
4.5 psf'
Sidelite-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50 psf
Anchor Derails-DWG-MA-FL0211-17
OXO
I/S
Opaque Door
9'0" x 6'8"
+551-55
0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelites
Glazed Sidelite
Sidelites-No
Maximmn Panel Size: 3'0" x 6'8" /Sidelim: 3'0" x 6'8"
Anchor Dctails-DWG-MA-FL0211-17
OXO
O/S
Opaque Door
910" x 6'8"
+551-55
3.0 psF
Door -Yes
NCTL-210-2930-1
Single w/Sidelites
Glazed Sidelite
4.5 psf'
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
OXXO
I/S
Opaque Door
12'4" x 6'8"
+551-55
0 psf
Door -Yes
NCTL-210-2930-1
Double w/Sidelites
Glazed Sidelite
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
OXXO
O/S
Opaque Door
12'4" x 6'8"
+55/-55
3.0 psF
Door -Yes
NCTL-210-2930-1
Double w/Sidelites
Glazed Sidelite
4.5 psf'
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelito: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
Bumper Outswing Threshold 2 -DenotesLSeries Ounsving Threshold 3-lb-Darn Outswing Threshold
National Accr on & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes,
Tel: (804) 684-5124/Fax: (804) 684-5122
NAMI AUTHORIZED SIGNATURE:
VA 23072