Loading...
HomeMy WebLinkAboutAnchor CalculationsL. Roberto Lomas P.E. RECEIVED 1432 Woodford Rd. Manufacturer: MBSO011e Lewisville, NC27023 MAR Report #: 514010 434-6e8-0609 "0 Date: 05/01/2017 rllomas@lrlomasr)e.com Test Report: WA I JI- L.ucle L.ounCy, Permitting Product: Single door 3' x 6'8= (Wood Frame) Scone: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/ d w/out gap: a. With threads present in show plane Fastener type: #10 wad screw (NDS 2012, TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fte v 80.000 psi Side member: Douglas Fir-Larch(G=0.50) Main member: Spruce-Pine-Fir(G=0.42) Side member thickness: t,= L000 in Main member thickness: tm= 1.500 in Side member dowel bearing strength: F.= 4.650 psi Main member dowel bearing strength: F„n= 3.350 psi Side member dowel bearing length: 1,= 1.000 in Main member dowel bearing length: 1.= 1.140 in Mode I. qm= 636.5 lbs/in P= 725.61 lbs KD = 2.400 Z = 302 lb. Mode 3. qs= 884 lbs/in P= 884 lbs KD = 2.400 Z,= 368 lbs Min. Design value: Z= 110 lbs Mode 11 A: 0.0007 B: 1.07 C. -427.67 P= 331 Its Ko = 2.400 Z= 138 lb. Duration Factor: Co= 1.6 Mode III,,, A: 0.00096 B: 0.57 C:-253.62 Ms= 46.8 in-lbs P= 297 lbs KD = 2.400 Z. 124 lbs Mode III, A: 0.00107 8: a5 C: -267.7 Mm= 46.8 in-lbs P= 319 Its KD = 2.400 Z= 133 lbs Made IV A: 0.0014 B: 0.000 C: -93.6 P= 263 Ibs Ke = 2.400 Z. 110 lbs Allowable Design Value (ZCD): Z'= 175 lbs/anchor Solid members w/ 6 Wout gap: a. With threads present in shear plane Fastener type: #10 woad screw (NDS 2012. TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: F. 1.140 in Screw bending yield strength: F,, = 80,000 psi Side member: Douglas Fir-Larch(G=0.50) Moin member: Steel strap/clip Side member thickness: t,= 1.000 in Main member thickness: %= 0.048 in Side member dowel bearing strength: Fes= 4,650 psi Main member dowel bearing strength: Fm, = 61,850 psi Side member dowel hewing length: 1.= 1.000 in Main member dowel bearing length: 1== 1.140 in Made L qm= 11752 lbs/in P= 13397 lbs Kb = 2.400 Z== 5582 lbs Mode I, qs= 884 lbs/in P= 884 lbs Ke = 2.400 Z,= 368 lbs Min. Design value: Z= 163 lbs Mode II A: D0003 B: 1.07 C:-4038.9 P= 2287 lbs Ka = 2.400 Z= 953 Do. Duration Factor: CD= 1.6 Mode III, Mode III, Mode IV A: 0.0006 B: 0.000 C: -93.6 P= 392 lbs Ko = 2.400 Z= 163 lbs Allowable Design Value (ZCa: Z.= 262 lbs/anchor Fastener type: 1/4" ITW Tapcon N.O.A. 16-1222.06 Substrate: Hollow block Minimum embedment 1.25 in Edge distance: 4.00 in Tabulated shear design value: Z = 202 lbs Edge distance: 2.00 in Tabulated shear design value: Z= 161 lbs Actual edge distance: 2.50 in Reduction factor: 0.85 FIL! � Spacing: 4.00 in Tabulated chew deign value: Z = 202 lbs ` • L h !/i Spacing: 2.00 in Tabulated shear design value: Z= 164 lb. V Actual sps9 acing: 3.00 in Reduction factor: 0.91 \ • • •r E Af if Allowable Design Value (Zf,,J: Z"= 155 Ibs/archor �• �\ � •� i Minimum anchor capacity: 155 Ibs/arch., A: 0.00059 B: 0.57 C:-3864.9 Ms= 46.8 in-lbs P= 2126 lbs KD = 2.400 Z= 986 lost Note: Anchors with the least capacity Is used forcalculations to qualAy anchors with higher capacity. Anchor calculations, minimum reouired anchors 36.38 Design pressure: 85.0 psi RA 79.25 1 of 2 A: 0.00033 B: 0.5 C: -267.7 Mm= 46.8 in-lbs P= 42016s KD = 2.400 Z= 175 lb. Zone Area (f}a) Load Qbs) Ind. (in) Max. O.C. (fn) Anchor Result Cap. (Ibs)(Zy Load (lbs) Al 2.3 195 IF N/A 155 2 98 OK At 7.7 656 6.00 18.00 155 5 131 OK *• 0 P ••*= ��TAT�� �Z D1 VIVA 1�?C�\�� Luis R. Lomas P.E. FL No.: 62514 5/2/2017 L. Roberto Lomas P. E. 1432 Wco0lord Rtl. Lewisville, NC27023 434-688-0609 rllomas@lrlomaspe.com Anchor Locations: 79.25 i 38 16.19 6.00 TYR 6.00 TIP. 1 LIC0 i 6.00 Manufacturer: Masonite Report #: 514010 Date: 05/01/2017 Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16° TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. . \\�i •••• • � 1Z �:'•\CEIVSF9cpy �• TAT 50F •4� • �:/� %s/ONAL1E�G`�N Luis R. Lomas P.E. FL No.: 62514 2 of 2 5/2/2017