HomeMy WebLinkAboutBoundary SurveyTHE MEAN HIGH WATER SURVEY DEPICTED HEREON COMPLIES WITH CHAPTER 177, PART 11, FLORIDA.. STATUTES
AND IS RECORDED IN THE PUBLIC REPOSITORY OF THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION,
BUREAU OF SURVEY AND MAPPING AS MEAN HIGH WATER SURVEY FILE
S89'19' 29"W 945.79'(M)
NORTH LINE SECTION 14-34-40
NW CORNER
14-34-40
FOUND 6"4"
CONCRETE
MONUMENT
BRYN MAWR OCEAN TOWERS
CONDOMINIUM
(NOT INCLUDED)
S.110' OF N.660' 14-34-40
(WEST OF A-1-A)
VACANT
(NOT INCLUDED)
FINISHED FLOOR ELEVATION DATA:
TOP OF FLOOR EL: 24.5'
e"
�- BOTTOM OF FLOOR. EL' 23.83'
BOTTOM OF BEAM EL: 22.5' -
D.E.P. FLOOD ELEVATION FOR COLLAPSIBLE WALLS
EL• 17.65'
ST. LUCIE COUNTY FLOOD EL: 16.17' ,�
}
�-- GARAGE FLOOR EL: 14.5'#
GROUND EL = 14.0'(VARIES) iF
ST. LUCIE COUNTY FLOOD ELEVATION: 16.17'
D.E.P. FLOOD ELEVATION FOR COLLAPSIBLE WALLS: 17.65'
COORDINATE NOTES:
R=12: N1161283.10(RECORD)
E722650.34(RECORD) SZ
SOFSP�k-
N1161283.61(MEASURED) E p01N
UN
E722650.15(MEASURED)
oftA
A=35: N1161995.693
E722387.090 €
BEARINGS/ANGLES SHOWN ARE -
ADJUSTED. TRAVERSE SHOWN IS BY SEAWARD AT ATLANTIC VIEW
TWO POINT RESECTION. CONDOMINIUM
REVISED HOUSE (ADDED BALCONY): 10/23/07 (NOT INCLUDED)
REVISED HOUSE: 4/18/2006
ADDED CERTIFICATION: 5/31/2005
REVISED HOUSE: 4/21/2005 FLOOD ZONE NOTE:
REVISED PER CLIENT COMMENTS: 1/19/2005 BY GRAPHIC PLOTTING ONLY THIS PROPERTY IS IN AN
REVISED PER CLIENT COMMENTS: 8/11/2004 UNDEVELOPED COASTAL BARRIER AND IS IN ZONES X,
REVISED PER CLIENT COMMENTS: 6/8/2004 AO(DEPTHI'), AO(DEPTH2'), VE(EL15) OF THE FLOOD INSURANCI
CORRECTED MISSING CURVE DATA: 4/20/2004 RATE MAP, COMMUNITY PANEL NO. 12111C0089G, WHICH HAS At,
REVISED SITE PLAN: 2/26/2003 EFFECTIVE DATE OF JUNE 30, 1999 AND IS IN A SPECIAL FLOG
REVISED SITE PLAN: 2/21/2003 HAZARD AREA. FIELD SURVEYING WAS NOT PERFORMED TO
ADDED PROPOSED DUNE CROSSING: 11/11/2002 DETERMINE THESE FLOOD ZONES. FOR FURTHER INFORMATION V
REVISED SITE PLAN: 8/14/2002 A VARIANCE CONTACT THE FEDERAL EMERGENCY MANAGEMENT
REVISED SITE PLAN: 8/7/2002 AGENCY AT 1-800-638-6620.
REVISED HOUSE/SITE PLAN: 7/29/2002
REVISED HOUSE/SITE PLAN: 7/15/2002 FLOOD INSURANCE NOT AVAILABLE FOR STRUCTURES NEWLY
REVISED HOUSE/SITE PLAN: 6/18/2002 BUILT OR SUBSTANTIALLY IMPROVED ON OR AFTER OCTOBER 1j
REVISED TO SHOW TRAVERSE LINE: 12/6/2000 1983 IN DESIGNATED COASTAL BARRIERS.
REVISED: 9 /15/2000
REVISED TO SHOW MEAN HIGH WATER
LINE: 8/4/2000
ADDED PROPOSED HOUSE: 5/30/2000
FIELD SURVEY DATE: 12/4/99 ADDED FORMBOARDS 4/17/2007
DRAWING COMPLETION DATE: 12/9/99 _ TOP OF FORM BOARD ELEVATION.
F.B.: L1 PG: 27 4'
FILE:99204.DWG, .CR5, .TXT
PROJECT: 99204
S89'19' 29"W
9
FOUND CCCL
GRAPHIC ',SCALE
0 10 20
( IN FEET )
1 inch = 20 ft.
OLD COASTAL CONSTRUCTION SET BACK LINE
PLAT BOOK 16, PAGE 32, MARCH 1972
ST. LUCIE COUNTY PROPERTY
VACANT
(NOT INCLUDED)
FLOOD ZONE AO FLOOD ZONE VE
CURVE TABLE
CURVE
LENGTH
RADIUS
DELTA
CHORD
BEARING
I CHORD
Cl
15.91
2914.93
00*18'46"
N15'15'08"W
15.91
C2
2,78
2864.93
00-03'20"
N15-22'51"WI
2.78
SITE ELEVATION NOTE:
SEASONAL HIGH WATER (SHW) IS CALCULATED BY THE
BEARING REFERENCE NOTE:
FOLLOWING FORMULA AS ESTABLISHED BY BEACHES AND
THE BEARINGS SHOWN HEREON REFER TO A LINE CALCULATED
COASTAL SYSTEMS:
BETWEEN CCCL MARKERS 94-77-A35 AND R-12 (MARKER '
(NGVD MHW + NGVD MLW)*1.5+NGVDMHW = NGVD SHW
R-12 IS LOCATED ON THE OLD COASTAL CONSTRUCTION _
(1.97(RANGE)+1.23)*1.50+1.97 = 6.$6 FEET NGVD
CONTROL LINE). THE 'A' MONUMENTS FOR SEVERAL MILES
NORTH AND SEVERAL MILES SOUTH ARE DESTROYED. THEREFOR
MHW =MEAN HIGH WATER
VALUES FOR R-12 WERE OBTAINED FROM BEACHES AND
MLW = MEAN LOW WATER
COASTAL SYSTEMS FOR THIS PROJECT. THE COASTAL
CONSTRUCTIONCONTROL LINE IS THE LATEST AVAILABLE AS
RECORDED 1N PLAT BOOK 26, PAGE 26, PUBLIC RECORDS OF
SITE INFORMATION: I
ST. LUCIE COUNTY.
PROPERTY TAX PARCEL IDENTIFICATIQIN NUMBER
COORDINATE REFERENCE NOTE:
1414-220-0005-0005
THE COORDINATES SHOWN HEREON REFER TO CCCL MARKERS -
PROPERTY OWNER: LAKE GROVE DEVELOPMENT
94-77-A35 AND R-12. VALUES FOR R-12 WERE OBTAINED
INCORPORATED
FROM BEACHES AND COASTAL SYSTEMS FOR THIS PROJECT.
VALUES FOR 94-77-A35 WERE OBTAINED FROM PLAT BOOK 26,
PROPERTY CONTAINS 0.48 ACRES MORE OR LESS
PAGE 26. COORDINATES ARE IN THE NORTH AMERICAN DATUM
(NOT INCLUDING THE BEACH AREA)
OF 1927, FLORIDA MERCATOR EAST ZONE.
TO INDIAN RIVER COUNTY
LINE 2tMILES
S�
9�
9
> CONDOMINIUM
V.660' 14-34-40
OF A-1-A
VIEW CONDOMINIUM
TO FT.
LOCATION MAP
NOT TO SCALE
SED POTABLE
LINE.
PROPOSED 10'x10' WOOD DECK
FOR SHOWER AND REST AREA.
9�
Y�
�C,
0
P
OJECT SITE �92
SEAWARD AT ATLANTIC VIEW CONDOMINIUM
ATLANTIC OCEAN
MEAN HIGH WATER ELEVATION 1.94 FEET,
N.G.V.D.1929 AS LOCATED ON'12/4/1999
FOUND 3/4" S89M9129 7W280'±
IRON PIPE
LIMITS OF
FILL/EXCAVATION
SEAWARD AT ATLANTIC VIEW
CONDOMINIUM
(NOT INCLUDED)
LEGAL DESCRIPTION
THE SOUTH 110 FEET OF THE NORTH 660 FEET OF
SECTION 14, TOWNSHIP 34 SOUTH, RANGE 40 EAST
LYING EAST OF STATE ROAD A1A RIGHT-OF-WAY,
SITUATED IN ST. LUCIE COUNTY, FLORIDA.
BOUNDARY AND MEAN HIGH
WATER LINE SURVEY
MEAN HIGH WATER NOTES:
CERTIFICATION VALID TO:
SURVEYOR'S NOTES:
1. LOCATED ON U.S.G.S. QUAD SHEET "INDRIO".
1. ADNAN ALGHITA
1. BEARINGS REFER TO COASTAL CONSTRUCTION CON' ROL LINE
2. PROPERTY IS IN SECTION 14, TOWNSHIP 34 SOUTH, RANGE 40
CERTIFICATION:
(CCCL) AS RECORDED IN PLAT BOOK 26, PAGE 26. BEARING BASE
IS THE LINE BETWEEN CCCL MARKERS 94-77-A35 AND R-12.
EAST.
3. METHODOLOGY FOR MEAN HIGH WATER LINE LOCATION IS EXTEND
I HEREBY CERTIFY THAT THE SKETCH SHOWN HEREON
IS A CORRECT' REPRESENTATION
2. (P) = PLAT MEASUREMENT; (M) = FIELD MEASUREMENT
MHW HEIGHT ONTO JOB SITE AS SPECIFIED BY LABINS WEBSITE
OF A SURVEY DONE UNDER MY DIRECTION AND IS TRUE AND CORRECT TO THE BEST OF
3. RIGHT-OF-WAY INFORMATION TAKEN FROM D.O.T. MAP NUMBER
INFORMATION.
MY KNOWLEDGE AND BELIEF. NO SEARCH OF THE PUBLIC RECORDS MADE FOR ERRORS
4. ELEVATION OF 1.94 FEET N.G.V.D. 1929 DATUM ESTABLISHED AS
OR OMISSIONS OF SAID DESCRIPTION. EASEMENTS OF
RECORD NOT SHOWN UNLESS
9451-250, DATED APRIL'S0.
4. THE LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR
MHW ELEVATION AT THIS SITE, USING WEBSITE TIC MARKS 903 AND.
FURNISHED. I FURTHER CERTIFY THAT THIS SURVEY MEETS
THE MINIMUM TECHNICAL
RIGHT-OF-WAYS, EASEMENTS, OR OTHER ENCUMBRANCES.
904.
STANDARDS SET FORTH UNDER RULE 61G17-6 F.A.C.
BY THE FLORIDA BOARD OF
5. UNDERGROUND UTILITIES NOT LOCATED PER THIS SURVEY.
5. ELEVATIONS REFER TO N.G.V.D. 1929 DATUM, BENCHMARK A35.
SURVEYORS AND MAPPERS.
6. THIS SURVEY DOES NOT STATE WHETHER THE LAND SHOWN
6. THIS MEAN HIGH WATER LINE SURVEY COMPLIES WITH CHAPTER
PART FLORIDA STATUTES.
HEREON IS BUILDABLE OR NOT BUILDABLE,
7. CENTERLINE OF ROAD; R/W.= RIGHT-OF-WAY
7. MHW =MEAN HIGH WATER.
ME
CHRISTIAN FENEX AND ASSOCIATES,
LLC
=
B. ELEVATIONS INDICATED HEREON ARE IN FEET AND DECIMALS
POWER POLE; --OE--= OVERHEAD ELECTRICAL WIRES
REFERENCED TO NGVD 1929 DATUM.
PROFESSIONAL SURVEYING AND MAPPING
9. LEGAL DESCRIPTION PROVDED BY CLIENT, THIS SURVEY
ENVIRONMENTAL CONSULTING-
PREPARED WITHOUT BENEFIT OF TITLE,
10. SITE PLAN IS SUBJECT TO REVIEW BY APPROPRIATE GOVERNING
BIOLOGICAL ASSESSMENT BY:
1657 S. DIXIE HIGHWAY, STUART, FLORIDA
AGENCIES.
BLYTHE ENVIRONMENTAL, INC.
P.O. BOX 2533, PALM CITY, FL 34991
CHRISTIANdEl
PH.(772)283-2977 FAX,(772)283-2979
FLA. REG.h
5782 SE HULL ST.
LICENSED BUSINESS # 6858
---
STUART, FLORIDA 34994
561-287-0549
NOT VAUD WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA UCENSED SURVEYOR'AND•MAPP.ER.,-'
I