HomeMy WebLinkAboutCorrection of Modification of a PermitSTATE OF FLORIDA
0AupeoiEniu
DEPARTMENT OF ENVIRONMENTAL PROTECTION
r
Division of Water Resource Management
Bureau of Beaches and Coastal Systems
g FLORI1
3900 Commonwealth Blvd. - Mail Station 300
e
Tallahassee, Florida 32399-3000
(850)487-4475
PERMIT NUMBER: SL-172 (Amend) MI (Corrected)
17�tt7rlYMlldy
Lake Garden Development, Inc.
Attn: Adnan Alghita, President
Post Office Box 517
Jensen Beach, Florida 34958
CORRECTION OF MODIFICATION OF A PERMIT FOR CONSTRUCTION OR OTHER
ACTIVITIES PURSUANT TO SECTION 161.053, FLORIDA STATUTES
FOREV96WROW1
FINDINGS OF FACT: An application for authorization to conduct the activities seaward of the
coastal construction control line was approved by the Department of Environmental Protection on
March. 28, 2001: The permit was subsequently amended and modified on April 29, 2001, and
August 4, 2004, respectively. The permit contained an error in the project description. The project
is located landward of the 30-year erosion projection. However, there is no existing line of
construction established by major structures in the immediate area.
CONCLUSIONS OF LAW: After considering the merits of the proposal and any written objections from
affected persons, the Department finds that upon, compliance with the permit conditions, the activities
indicated in the project description of this corrected final order are of such a nature that they will result in
no significant adverse impacts to the beach/dune areas or to -adjacent properties; that the work is not
expected to adversely impact nesting sea turtles, their hatchlings, or their habitat; that the work is
expendable in nature, and/or is appropriately designed in.accordance with Rule 6213-33.005, Florida
Administrative Code; and that it is an activity or type of construction which the designee of the Chief of
the Bureau of Beaches and Coastal Systems has authority to approve or deny pursuant to DEP Directive
137, effective. September 27, 2002. The direct and cumulative impacts to the beach and dune system that
will be caused by both the seaward location and shore -parallel width of the proposed construction
represent the maximum such impacts that are acceptable to the Department., Therefore, future
construction on the site seaward of the coastal construction control line shall not extend further seaward
of, or increase the shore -parallel coverage occupied by, the proposed structures approved pursuant to this
permit. Based on the.foregoing considerations, the designee approves the application; authorizes
construction and/or activities at the location indicated below in strict accordance with the project
description, the approved plans (if any) and the General Permit Conditions which are attached and are by
this reference incorporated herein, and any additional conditions 'shown below, pursuant to Subsection
161.053(5), Florida Statutes.
EXPIRATION DATE: September 22, 2005
LOCATION: Between approximately 105 feet north and 10 feet south of the Department of
Environmental Protection's reference monument R-12, in St. Lucie County. Project address: 5050 North
Highway A-1-A, Fort Pierce.
PERMITTEE: Lake Garden Development, Inc.
PERMIT NUMBER: SL-172 (Amend) MI (Corrected)
'PAGE 2
PROJECT DESCRIPTION:
Single -Family Dwelling
I. Location relative to landward property line.
1.1. Dwelling Foundation: A maximum of 87 feet seaward.
1.2. Swimming Pool Foundation: A maximum of 93 feet seaward.
1.3. Cantilevered deck: A maximum of 97 feet seaward.
2. Location relative to control line:
2.1. Dwelling Foundation: A maximum of 156 feet seaward.
2.2. Swimming Pool Foundation: A maximum of 162 feet seaward.
2.3. Cantilevered deck: A maximum of 166 feet seaward.
3. Exterior dimensions: 72 feet in the shore -normal direction by78.83 88.7 feet in the shore -parallel
direction.
4. Type of foundation: 16-inch diameter augercast concrete pile.
5. Penetration of piles: To elevation -10.0 feet (NGVD), or deeper.
6. Structural elevation (bottom of beam): +23:0 feet (NGVD).
7. Pile cap elevation: +I L5 feet (NGVD).
8. - Elevation of understructure parking area: +15.5 feet (NGVD).
Fill (See Special Permit Condition 7)'
1. Volume of fill to be placed: Approximately 306 cubic yards.
2. Location of fill to be placed: From 36 feet to 108 feet seaward of the control line.
W
PERMITTEE: Lake.Garden Development, Inc.
PERMIT NUMBER: SL-172 (Amend) MI (Corrected)
PAGE
- Other Structures
A wooden beach/dune walkover structure of dimensions 86 feet shore -normal by 4 feet shore -
parallel is to be located a maximum of 192 feet seaward of the landward property line. See
Special Permit Condition 8.
2. A paver -block driveway on the northwest side. of the proposed dwelling.
A 10-foot by 10-foot wooden gazebo is to be attached to the north side of the dune walkover
structure and located as specified in Special Permit Condition 8.
SPECIAL PERMIT CONDITIONS:
-•-
-
-
'
F-...._
5. Prior to commencement of construction activity authorized.by this permit, a preconstrction
conference shall be held at the site among the contractor, the owner or authorized agent, and a
staff representative of the Bureau of Beaches and Coastal Systems to establish anunderstanding
among the parties as to the items specified in the special and standard conditions of the permit.
The proposed locations of the structures shall be staked out for the conference. -
6. Construction activity authorized by this permit shall not commence until after the time period
provided in the public notice. for the public to exercise any rights they.may have under Chapter
120, Florida Statutes, has expired, or if a hearing is requested, disposition of the hearing request
has been made.
The fill material shall be obtained from a source landward of the control line and shall consist of
sand which is similar to that already on thesite in both grain size and coloration. This fill material
shall be free of construction debris, rocks, or other foreign matter. A sample of the sand shall be
provided to the staff representative during the preconstruction conference.
Pa qy . J i
y4..w. i 1� , 1 ^ In�• , f M C
v:'Yu tlN.W! i' i1
I
PERMITTEE: Lake Garden Development, Inc. .
PERMIT NUMBER: SL-172 (Amend) Ml (Corrected)
PAGE
8. The deck of the walkover structure shall maintain an elevation just above the existing dune
vegetation canopy, and the width of. the structure shall not exceed 4 feet. The piles for the
walkover structure shall not be greater than 4-inch by 4-inch posts and shall not be encased in
concrete. The walkover shall extend at least up to the existing line of vegetation but not further
than 10 feet seaward of the vegetation. The optimum siting and height of the walkover structure
shall be determined by the staff representative during the preconstruction conference to provide'.
maximum protection to the existing dune topography and vegetation located on the site. The
gazebo shall be located a minimum of 30 feet landward of the crest of the dune (i.e. the +13.0-
foot contour shown on'the.site plan).
All permanent exterior lighting shall be installed and maintained as depicted in the approved
lighting schematic.' No additional exterior lighting is authorized.
CAVEAT:
Due to potential adverse impacts. to the beach and dune system. that may result from additional.,
development on the property, the shore -parallel and seaward extent of the permitted structures shall not be
increased, nor will any additional major structures.be permitted which would exceed the limits established
by the permitted construction seaward of the coastal construction control line.
Corrected approved plans are incorporated into this permit by reference, as are any previously approved
plans which are not superseded.by corrected approved plans. -This corrected permit, with the referenced
attachments, comprises the entire permi�nd,supersedes the permit as previously issued.
Done and ordered thisC� day of (✓ 2005, in Tallahassee; Florida.
Attachment: General Permit Conditions
FILING AND ACKNOWLEDGEMENT
FILED, on this date, pursuant to S120.52
Florida Statutes, with the designated
Department Clerk, receipt of which
reby.acknowledged.
Deputy Clerk Date
of
Protection
,TWy D. YcNeal, P.E., Trdgram Administrator
Bureau of Beaches and Coastal Systems
x
0M RR 4.
y