Loading...
HomeMy WebLinkAboutLetter - Pile Monitoring LogsA. M. ENGINEERING AND TESTING, INC. Pile Installation 5050 North AIA, St. Lucie County Project No. D-01377 A. M. Engineering and Testing, Inc. has appreciated the opportunity to assist you with this phase of your project. If you have any questions regarding this report or need any further information, please call us. A. M. fWvidAlker Project Manager RGA/DA AND TESTING, INC. Attachments: Pile Monitoring Logs (6 Pages) Pile Layout Drawing Copies: Client - 2 reLcca Grant Ascoli, .E. 3� z/�, Senior Geotechnical Engineer Florida Registration No. 51863 tnrverWetAppsUM DATAUdmm Investment and Dev. InclResidence. 50505 North AIA. SLOPile Installation Summarv.doc A. M. ENGINEERING AND TESTING, INC. 3504 INDUSTRIAL 33RD STREET FORT PIERCE, FLORIDA 34946 (772) 461-7508 OFFICE - (772) 461-8880 FAx August 17, 2005 Adrian Investment & Development, Inc. Attn: Mr. Adrian K. Alghita P.O. Box 517 Jensen Beach, Florida 34958 Re: Auger -Cast Pile Installation for Proposed Residence 5050 North AIA, St. Lucie County, Florida Project No. D-01377 Ladies and Gentlemen: A. M. Engineering and Testing, Inc. is pleased to submit this report of our pile installation monitoring for the referenced project. Representatives of A. M. Engineering was present on site on August 1 and 2, 2005, to observe the installation of the cast -in -place auger piles. Logs were kept of the pertinent information and are enclosed. The pile identification numbers noted on the logs correspond to the numbers indicated on the enclosed pile layout plan The number of "Required Strokes" was determined by measuring the pump strokes needed to fill a container of known volume. The strokes necessary to fill the theoretical volume plus 10 percent were then calculated to determine the required strokes for the individual piles. The pile lengths noted on the logs are based on the depths below the existing grade at the time that the piles were installed. All of the monitored piles took grout equal to or in excess of their theoretical volume plus 10 percent. Placement of the reinforcing steel for the piles was also monitored. The steel reinforcing was constructed and placed in substantial compliance with the plans. Concrete grout cubes were made for each 50 cubic yards of grout placed. A total of three sets of cubes were molded. The results will be submitted under separate cover. T TreasteCoast Building Engineers,. C Harvey Koehnen, P.E. B 7205 Elyse Circle E Port St. Lucie, FL 34952-8212 Inc. Phone: (772) 466-5509 FAX: (772) 489-3035 January 24, 2008 To: St. Lucie County Building Dept. Attention: Joe Cicio Re: Permit #0612-0362 Adnan Alghita 5050 N AIA North To Whom It May Concern: The following is in regards to the above project, all the stem walls, beams and garage floor were inspected and were ready to pour. The fill in the garage between the stem walls and under the slab was compacted and does not need a compactors test. If you have any questions, I can be reached at 772-466-5509. Very truly yours, Harvey Koehnen; P.E: 32831 Hkoehnenna tcbeweb.com www.tcbeweb.corn MAR-15-06 11:55 AM ADN INV AND DEV INC P.01 W�R�ObQ �, 15 2096 �ST.. P,,BLIC WORKS I Adnan Investment & Development, Inc Certified General Contractor CGC 056992 109 Aqua Ra Drive Jensen Beach, FL 34957 March 15, 2006 TO: St. Lucie County Building Department FAX: 462-1735 5050 N Al A, Ft. Pierce Permit #SLC 0505-065C Prank Williams MESSAGE: Dear Mr. Williams: FAX COVER SHEET 772-229-8557 TEL, 772-229-3538 FAX e-mall: adnan101 iolmall.com FROM: Adnan K. Alghita, President Adnan Investment & Development, Inc. FILECOF Total Pages Including Cover 1 The reason we have not ordered the inspection is because of delays imposed on us by others. Therefore, there is no need for the permit to expire. We will be calling you in a few days for inspection of the grade beams "forms and re -bars inspection" Sincerely, Adnan K. Alghila President AKA:mka T Treasiu`'-" "oast Building Engineers, ' C Harvey ,.., �ehnen, P.E. B 7205 Elyse Circle E Port St. Lucie, FL 34952-8212 Inc. Phone: (772) 466-5509 FAX: (772) 489-3035 January 24, 2008 To: St. Lucie County Building Dept. Attention: Joe Cicio Re: Permit #0612-0362 Adnan Alghita 5050 N AlA North To Whom It May Concern: The following is in regards to the above project, all the stem walls, beams and garage floor were inspected and were ready to pour. The fill in the garage between the stem walls and under the slab was compacted and does not need a compactors test. If you have any questions, I can be reached at 772-466-5509. Very truly yours, Harvey Koehnen, P.E. 32831 I-Ikoehnen@tcbeweb.com tcbeweb.com www.tcbeweb.com