HomeMy WebLinkAbout2006-0411 - EngineerLtrArchitectonic Inc June 15, 2020 St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Department for the structure located at, 5951 Traveler's Way, Fort Pierce, FL, St. Lucie County, FL. Manufacturer: JA Taylor Roofing Profiles: 5-V Crimp 24 ga. Steel, FL#17443.1 Code: FBC 2017 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 20' Maximum Pitch: 6/12 Minimum Required Design Pressure: Zone1: -30.92 Zone 2:-51.55 Zone3: -77.32 Maximum Uplift Pressure: -69.25 @ 16" o.c. Zone 1 & 2, Zone 3 -129.25 @ 6" o.c. Fasteners: #9-15 x 1.5" @ 16" o.c. with sealing washer through panel rib with'/." min. penetration through plywood Underlayment: 30# Felt w/1-1/4" annular ring shank roofing nails w/32 ga. tin tabs @ 6" o.c. perimeter and 12" ox. field Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out Zone 1, 4" O.C. perimeter, and 6" O.C. field Zone 2, and 4" O.C. thru out Zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: 7724607751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1