Loading...
HomeMy WebLinkAboutProduct Approval GENERAC0Protector QS ® PROTECTOR® QS SERIES Series Standby Generators Liquid-Cooled Gaseous Engine INCLUDES: Standby Power Rating • Two-Line LCD Multilingual Digital Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz EvolutionT" Controller (English/Spanish/ Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz French/Portuguese) with external viewing Model RG032 (Aluminum - Bisque) - 32 k\&I 60 Hz window for easy indication of generator Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz status and breaker position. Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz • True PowerTM Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure _g - z' r.> GENERAC • Closed Coolant Recovery System • Smart Battery Charger — ' • UV/Ozone Resistant Hoses • ±1%Voltage Regulation e • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed C � QUIEFFES • Capability to be installed within 18" (457) mm of a building* Meets EPA Emission Regulations *Only if located away from doors,windows,and fresh air 22&27 kW are CA/MA emissions compliant intakes,and unless otherwise directed by local codes. 32&38 kW not for sale in CA/MA FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION. GENERAC'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing, reliability all Generac models. It provides optimized FAST RESPONSE to changing testing, environmental testing, destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA, EGSA, and other standards, allows you to electronically torque-matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1%. systems will provide superior performance. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit,from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES. Long life and reliability are d PROTOTYPE TESTED w NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this d SYSTEM TORSIONAL TESTED d MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERAC' I _ GENERAC® 22 • 27 • 32 • 38 • 48 kill application & engineering data 8 GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS: 22,27, 32 & 33 k _ Type Synchronous Make Generac Rotor Insulation Class H(22&27 kW)or Model In-line F(32,38&48 kW) Cylinders 4 Stator Insulation Class H Displacement(Liters) 2.4 Telephone Interference Factor(TIF) <50 Bore(in/mm) 3.41/86.5 Alternator Output Leads 1-Phase 4 wire Stroke(in/mm) 3.94/100 Alternator Output Leads 3-Phase 6 wire Compression Ratio 9.5:1 Bearings Sealed Ball Naturally Aspirated(22&27 kW)or Coupling Flexible Disc Intake Air System Turbocharged/Aftercooled Excitation System Direct (32&38 kW) Lifter Type Hydraulic VOLTAGE REGULATION Type Electronic ENGINE SPECIFICATIONS: 48 W Sensing Single Phase Make Generac Regulation -* 1% Model UType GOVERNOR SPECIFICATIONS Cylinders 8 Displacement(Liters) 5.4 Type Electronic Bore(in/mm) 3.55/90.2 Frequency Regulation Isochronous Strokein/mm Steady State Regulation ±0.25% ( ) 4.17/105.9 Compression Ratio 9;1 ELECTRICAL SYSTEM Intake Air System Naturally Aspirated Battery Charge Alternator 12 Volt 30 Amp Lifter Type Hydraulic Static Battery Charger 2.5 Amp ENGINE LUBRICATION SYSTEM Recommended Battery(battery not included) Group 26(22,27,32&38 kW) Oil Pump Type Gear or Group 24F(48 kW),525CCA System Voltage 12 Volts Oil Filter Type Full flow spin-on cartridge Crankcase Capacity(qt/I) 4/3.8(22,27,32&38 kW)or GENERATOR FEATURES 6/5.7(48 kW) Revolving field heavy duty generator ENGINE COOLING SYSTEM Directly connected to the engine Operating temperature rise 120°C above a 40°C ambient Type Closed Class H insulation is NEMA rated Class F insulation is NEMA rated Water Pump Belt driven All models fully prototyped tested 1980-22&27 kW Fan Speed(rpm) 1500-32&38 kW ENCLOSURE FEATURES 1954-48 kW Ensures protection against mother nature. Aluminum weather Electrostatically applied textured epoxy paint for added Fan Diameter(in/mm) 18.1/459.7(22&27 kW)or protective enclosure durability. 22/558.8(32,38&48 kW) Enclosed critical grade Quiet,critical grade muffler is mounted inside the unit Fan Mode Pusher(22&27 kW)or muffler to prevent injuries. Puller(32,38&48 kW) Small,compact,attractive Makes for an easy,eye appealing installation. FUEL SYSTEM SAE Sound attenuated enclosure ensures quiet operation. Fuel Type Natural gas,propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14"water column/9-26 mm HG LP Fuel Pressure 11-14"Water Column (All ratings in accordance with BS5514,ISO3046,ISO8528,SAE J1349 and DIN6271) NG Fuel Pressure 5-14"Water Column GENERAC' 22 27 e 32 • 33 • 43 kW operating data 0 GENERATOR OUTPUT VOLTAGEAW-60 Hz kW LPG Amp LPG kW Nat.Gas Amp Nat.Gas CB Size(Both) 120/240 V,10,1.0 pf 22 92 22 92 100 RG022 120/208 V,30,0.8 pf 22 76 22 76 80 120/240 V,30,0.8 pf 22 66 22 66 80 120/240 V,10,1.0 pf 27 113 25 104 125 RG027 120/208 V,30,0.8 pf 27 94 25 87 100 120/240 V,30,0.8 pf 27 81 25 75 90 120/240 V,10,1.0 pf 32 133 32 133 150 RG032 120/208 V,30,0.8 pf 32 111 32 111 125 120/240 V,30,0.8 pf 32 96 32 96 100 277/480 V,30,0.8 pf 32 48 32 48 60 120/240 V,10,1.0 pf 38 158 38 158 175 RG038 120/208 V,30,0.8 pf 38 132 38 132 150 120/240 V,30,0.8 pf 38 114 38 114 125 277/480 V,30,0.8 pf 38 57 38 57 60 120/240 V,10,1.0 pf 48 200 48 200 200 RG048 120/208 V,30,0.8 1 48 167 48 167 175 120/240 V,30,0.8 pf 48 144 48 144 150 277/480 V,30,0.8 pf 48 72 48 72 80 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @ <.4 pf Natural Gas Propane 15% 30% (ft3/hr) (m3/hr) (gal/hr) (1/hr) (ft3/hr) 120/240 V,10 55 135 Exercise cycle 42 1.2 0.44 1.7 16 RG022 120/208 V,30 40 92 25%of rated load 100 2.8 1.1 4.2 40 120/240 V,30 35 80 RG022 50%of rated load 190 5.4 2.1 7.8 75 120/240 V.10 62 170 75%of rated load 255 7.2 2.8 10.5 101 RG027 120/208 V,30 70 120 1 100%of rated load 316 9 3.4 13 125 120/240 V,30 61 103 Exercise cycle 42 1.2 0.44 1.7 16 120/240 V,10 75 180 25%of rated load 108 3.1 1.2 4.5 43 RG032 120/208 V,30 87 210 RG027 50%of rated load 197 5.6 2.1 8.1 78 120/240 V,30 75 182 75%of rated load 287 8.2 3.1 11.8 114 277/480 V,30 36 87 100%of rated load 359 10.2 3.9 14.8 143 120/240 V,10 75 180 Exercise cycle 79 2.2 0.8 3.2 30 RG038 120/208 V.30 87 210 25%of rated load 144 4.1 1.7 6.3 60 120/240 V,30 75 182 RG032 50%of rated load 226 6.4 2.7 10.3 97 277/480 V,30 36 87 75%of rated load 298 6.4 3.7 13.9 132 120/240 V,10 85 195 100%of rated load 375 10.6 4.6 17.5 166 RG048 120/208 V,30 90 218 Exercise cycle 83 2.3 0.9 3.2 31 120/240 V,30 78 189 25%of rated load 162 4.6 1.7 6.6 62 277/480 V,30 36 87 RG038 50%of rated load 255 7.2 2.9 10.8 103 75%of rated load 345 9.8 4 15 142 100%of rated load 437 12.4 5.2 19 185 Note:Fuel pipe must be sized for full load. Exercise cycle 95 2.7 1 3.9 38 For Btu content,multiply 113/hr x 2520(LP)or W/hr x 1000(NG) 25%of rated load 204 5.8 2.16 8.5 82 For megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG) RG048 50%of rated load 392 11.1 4.14 15.7 151 Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and 75%of rated load 547 15.5 5.8 22.8 220 SCAOMD permitting purposes. 100%of rated load 756 21.5 7.96 31.3 302 STANDBY RATING:Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating.Ratings are in accordance with ISO-3046-1.Design and specifications are subject to change without notice. I GENERAC" 22 • 27 • 32 • 38 • 48 kW operating data 3 ENGINE COOLING 22 kW 27 kW 32&38 kW 48 kW Air flow(inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2 System coolant capacity(gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 3/11.4 Heat rejection to coolant(BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 186,000/196.2 Maximum operation air temperature on radiator(°C/°F) 60/150 Maximum ambient temperature(°C/°F) 50/140 COMBUSTION REQUIREMENTS Flow at rated power(cfm/cmm) 1 68/1.9 68/1.9 106/3 163/4.6 SOUND EMISSIONS Sound output in dB(A)at 23 ft(7 m)with generator in exercise mode' 1 61 61 58 63 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load' 1 70 70 64 68 `Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output(cfm/cmm) 165/4.7 180/5.1 1 300/8.5 1 414/11.7 Exhaust temperature at muffler outlet(°C/°F) 482/900 1 538/1000 1 579/1075 1 552/1025 ENGINE PARAMETERS Rated Synchronous rpm 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration...........................................................................................................3%for every 10°C above 25-'C or 1.65%for every 10°F above 77'F Altitude Deration(22,27&48 kW).....................................................................................1%for every 100 m above 183 m or 3%for every 1000 ft above 600 ft Altitude Deration(32&38 kW) ....................................................................................... 1%for every 100 m above 915 m or 3%for every 1000 ft above 3000 ft CONTROLLER FEATURES Two-Line Plain Text LCD Display....................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto ..............................................................................................................................................Automatic Start on Utility failure.7 day exerciser Off.......................................................................................:...................................Stops unit. Power is removed.Control and charger still operate. Manual.........................................................................................Start with starter control, unit stays on. If utility fails,transfer to load takes place. Programmable start delay between 10-30 seconds.................................................................................................................................................10 sec standard Engine Start Sequence.....................................................................................................................Cyclic cranking:16 sec on,7 rest(90 sec maximum duration) EngineWarm-up.....................................................................................................................................................................................................................5 sec EngineCool-Down..................................................................................................................................................................................................................1 min Starter Lock-out................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger........................................................................................................................................................................................................Standard Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................Standard AutomaticLow Oil Pressure Shutdown...............................................................................................................................................................................Standard OverspeedShutdown..............................................................................................................................................................................................Standard,72 Hz HighTemperature Shutdown...............................................................................................................................................................................................Standard OvercrankProtection..........................................................................................................................................................................................................Standard SafetyFused......................................................................................................................................................................................................................Standard Failureto Transfer Protection..............................................................................................................................................................................................Standard LowBattery Protection........................................................................................................................................................................................................Standard 50 Event Run Log...............................................................................................................................................................................................................Standard FutureSet Capable Exerciser..............................................................................................................................................................................................Standard IncorrectWiring Protection.................................................................................................................................................................................................Standard InternalFault Protection.....................................................................................................................................................................................................Standard CommonExternal Fault Capability......................................................................................................................................................................................Standard GovernorFailure Protection................................................................................................................................................................................................Standard I GENERAL® 22 • 27 • 32 • 38 • 48 W available accessories 0 Moe!# Protluc Dekcrrptron „ m _ Generac's Mobile Link allows you to check the status of your generator from _] anywhere that you have access to an Internet connection from a PC or with G006463-4 Mobile Link'"" any smart device.You will even be notified when a change in the generator's status occurs via e-mail or text message Note Harness Adapter Kit required. Available in the U.S. only. j G006478-0 Harness Adapter Kit l The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile LinkTM If the temperature regularly falls below 32 OF(0°C), install a cold weather kit G005630-1 -22,27,32&38 kW I i G005632-1-48 kW 1 Cold Weather Kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. G005616-0-22,27,32&38 kW g Extreme Cold £ Recommended where the temperature regularly falls below 32 OF(0°C)for ! G007088-0-48 kW Weather Kit ; extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to G005703-0-Bisque Paint Kit touch-up the paint to protect from future corrosion.The paint kit includes the i necessary paint to properly maintain or touch-up a generator enclosure. �G005656-0:22 &27 kW The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware G005984-0-32&38 kW Scheduled necessary to perform complete maintenance on Generac liquid-cooled Maintenance Kit generators. G006205-0-48 kW Local Wireless ? Completely wireless and battery powered, Generac's wireless remote monitor G006664-0 Monitor I provides you with instant status information without ever leaving the house ' Wireless Remote Recommended for use with the Wireless Remote on units up to 60 kW, Y G006665-0 Extension Harness r required for use on units 70 kW or greater. Smart Management Modules are used in conjunction with the Automatic Smart Management Transfer Switch to increase its power management capabilities. It provides G006873-0 I Module (50 Amps) additional power management flexibility not found in any other power l i management system. G006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. j The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the Wi-Fi LP Fuel Level connected LP fuel tank. Monitoring the LP tank's fuel level is an important I G007005-0 step in making sure your generator is ready to run during an unexpected Monitor g power failure.Status alerts are available through a free application to notify j when your LP tank is in need of a refill. I I w-us sen I7 � 0� Dc � N o � rn N .A SERVICE ITEM 2.4L NOTES: OIL FILL CAP EITHER SIDE j RADIATOR/EXHAUST OIL DIP STICK RIGHT SIDE 1.MINIMUM RECOMMENDED CONCRETE PAD SIZE:1092(43')WIDE X 1885(74.2")LONG. p DISCHARGE AIR OIL FILTER RIGHTSIDE REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. (BOTH SIDES) (BOTH SIDES) OIL DRAIN HOSE LEFTSIDE 2.ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE RADIATOR DRAIN LEFT SIDE AND SERVICING.THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT BATTERY 12 GRP 26 COOLANT RECOVERY BOTTLE LEFT SIDE APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, NEGATIVE GROUND RADIATOR FILL CAP ROOFTOP STATE,AND LOCAL CODES. AIR CLEANER ELEMENT LEFT SIDE 3.CONTROL PANEL I CIRCUIT BREAKER INFORMATION: P/N:077463 -SEE SPECIFICATION SHEET OR OWNERS MANUAL REMOVE COVE SPARK PLUGS LEFT SIDE -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. FOR ACCESS TOMUFFLER SEE NOTE 11 4.REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS RADIATOR FILL CAP DRIVE BELT EITHER SIDE -,: THE STUB-UP AREAS AS FOLLOWS: FAN BELT SEE NOTE 11 _HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION BATTERY LEFT SIDE NEUTRAL CONNECTION,BATTERY CHARGER 120 VOLT AC(0.5 AMP MAX)CONNECTION. REFERENCE OWNERS MANUAL -LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. FOR PERIODIC REPLACEMENT 5.CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 427PART LISTINGS. 6.BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND 116.81 RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7.REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 6.MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 516-11 GRADE 5 c (USE STANDARD SAE TORQUE SPECS) x-1741 9.MUST ALLOW FREE FLOW OF INTAKE AIR,DISCHARGE AIR AND EXHAUST.SEE SPEC ~1141 6Y9•g[Y4•g] SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. [5.6CENTER OF GRAVITY 10.GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE (SEE NOTE 5) AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. TOP VIEW 11.EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. EXHAUST MUFFLE ENCLOSED WITHIN CIRCUIT BREAKE GENERATOR ENCLOSURE SEE NOTE 3 631 [24 8] DOOR TYP *• ) r a f 1 ' n �, EAR ENCLOSURE Y � :[ COVER PANEL 980 SEE NOTE 4[38.61 RADIATOR/EXHAUST I r—""� 'I OVERALL - -;? VICE ACTION LATCH, DISCHARGE AIR =� e ��. E ONE PER DOOR, HEIGHTs USTOMER ACCESS 49 ONE LIFT OFF E ASSEMBLY,CONTROL < DOOR PER SIDE •.".-' r �"z [1'9] `' PANELACCESS, OF GENERATOR TYP is �.E BATTERY CHARGER - LOCATED WITHIN I SEE NOTE 4 7040�-I 48 [40.9] 776 [30.6]—moi 45 1490 OVERALL WIDTH [56.7]TP 11.91 FUEL LINE CONNECTION [7'8] 1560 [62.2] 314"NPT FEMALE COUPLING REAR VIEW TYP OVERALL LENGTH _ LEFT SIDE VIEW WEIGHT DATA RIGHT SIDE VIEW �• WEIGHT WEIGHT ENGINE/KW ENCLOSURE GENSET ONLY SHIPPING SKID SHIPPING WEIGHT ^p KVA MATERIAL KG ILBSI w+ KG[LBS] KG[LBS/ W 2W(60HZ) SINGLE PHASE 17.4KVA(50HZ) AL 410.5[905] 30[661 44019711 � THREE PHASE 22KVA(50HZ)PHASE 227KW(60H2) PH ? m SINGLE PHASE 27KVA((SOHZ) AL 426[940] 30[66) 456110061 DIMENSIONS:MM[[NCH] o THREE PHASE 27KVA(50HZ) w` m Q �� 13.5 X 29.5 MOUNTING SLOTS 'NOTE-STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. 4X CIRCUIT BREAKER,NEUTRAL AND CUSTOMER CONNECTION OPENING. 674 [26.5] 104.5 [4.11] STUB-UP AREA 28 9 51 [1.1] [Al [2.0] 10D [3.$) STUB-UP AREA 1370 [54.0] 210 [8.3] REMOVABLE STUB-UP COVER TOP VIEW 735 [28.9] 96 [3.8] 27 [1.0 [a 723 [28.51TYP 45 [1.8)TYP F� 1380 [54.3]TYP -I TYP MOUNTING SLOT CENTERS MOUNTING SLOT CENTERS 776 [30.6] 1580 [62.2] Al LEFT SIDE VIEW DIMENSIONS:MM[INCH) REAR VIEWCD �, H m Oo �. m N .P 6 o O 4l r1V N � G SERVICE ITEM 2.41 cr RADIATOR)EXHAUST OIL FILL CAP EITHER SIDE NOTES: co DISCHARGE AIR AIR INTAKE OILDIPSTICK RIGHT SIDE 1.MINIMUM RECOMMENDED CONCRETE PAD SIZE:1194(47")WIDE X 2255(88.8")LONG. (BOTH SIDES) (BOTH SIDES OIL FILTER RIGHT SIDE REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. Q OIL DRAIN HOSE RIGHTSIDE 2.ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE RADIATOR DRAIN HOSE LEFTSIDE AND SERVICING.THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT v COOLANT RECOVERY BOTTLE LEFT SIDE APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, 768 [30.21 RADIATOR FILL CAP ACCESS ROOFTOP STATE,AND LOCAL CODES. FlENTER OF GRAVITY AIR CLEANER ELEMENT RIGHTSIDE 3.CONTROL PANEL/CIRCUIT BREAKER INFORMATION: 167 SEE NOTE 5 SPARK PLUGS LEFT SIDE -SEE SPECIFICATION SHEET OR OWNERS MANUAL [6.61 MUFFLER 1 SEE NSTE 11 ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. DRIVE BELT EITHER SIDE 4.REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS FAN BELT I SEE NOTE 11 THE STUB-UP AREAS AS FOLLOWS: 'w BATTERY LEFT SIDE -HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION,NEUTRAL a ` N �:+x, CONNECTION,AND BATTERY CHARGER 120 VOLTAC(0.5 AMP MAX)CONNECTION. 535 [21.1] a € j' REFERENCE OWNERS MANUAL -LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. '� FOR PERIODIC REPLACEMENT 5.CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. y PART LISTINGS. 6.BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7.REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. S 8.MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 2.5"O.D.EXHAUST (USE STANDARD SAE TORQUE SPECS) OUTLET �;., „u k,� ,,. ,,"N, ', 9.MUST ALLOW FREE FLOW OF INTAKE AIR,DISCHARGE AIR AND EXHAUST.SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10.GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE REMOVE COVE TOPy1EW BATTERY 12V,GRP 26 AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. FOR ACCESS TO NEGATIVE GROUND 11.EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE, RADIATOR FILL CAP P/N:077483 REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH, EXHAUST MUFFLER ONE PER DOOR, ENCLOSED WITHIN CIRCUIT BREAKE 759 [29.9] ONE LIFT OFF GENERATOR ENCLOSURE SEEN TE3 DOOR TYP DOOR PER SIDE OF GENERATOR l — S77, ENCLOSURE COVER PANEL 1171[46.1] SEE NOTE 4 RAowrowexHAusT � 1 ? OVERALL as t- DISCHARGEAIR '' „ X '.x � HEIGHT USTOMER ACCESS xx ASSEMBLY,CONTROL { �* PANELACCESS, - '✓°. ,, _ { BATTERY CHARGER LOCATED WITHIN ' SEE NOTE 4 50 [2.0] 888 [35.0] I� 47 1857 173.11 TYP L 58 FUEL LINE CONNECTIO ] [2.31 1950 [76.8 OVERALL WIDTH [1.8] 3/4"NPT FEMALE COUPLING 1000 [39.4] TYP LEF_LS1RE_VIEW REAR-MEW OVERALL LENGTH TYP /LIFTING PROVISIONS RLGFILS[DE_9EW (4 PLACES) SEE NOTES 5JAND AND CENTER OF GRAVITY DIMENSIONS WEIGHT DATA �• WEIGHT WEIGHT ENCLOSURE KG[L SHIPPING WEIGHT ENGIN MATERIAL GEL ONLY SHIPPING SKID KG RBSI Yr KG BBJ KG[LBS] � 2.41.32KW AL 556[12251 44[981 600[1'231 DIMENSIONS:MM[INCH] 2AL 38KW AL 560112351 441981 605[13331 iY m m 0 cl a W NJ co co pr 13.5 X 29.5 MOUNTING SLOTS 'NOTE-STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. 4X CIRCUIT BREAKER,NEUTRAL AND CUSTOMER CONNECTION OPENING. r� 786 [30.9] 162 [6.4] 'STUB-UP AREA 12 [.5] 9 [Al 51 [2.0] 162 [6.4] "STUB-UP AREA REMOVABLE STUB-UP ACCESS COVER 1733 [66.2] 217 [8.5] (SHIPPED LOOSE WITH GENERATOR) TO BE INSTALLED DURING GENERATOR ZO_ICLEW INSTALLATION 850 [33.5] 116 [4.6] 25 838 [33.0]TYP 50 TYP r� 1750 [68.9]TYP - [1.0] MOUNTING CENTERS [2.0] MOUNTING SLOTS TYP 888 [35.01- 1950 [76.8] BEALZVIEA �• wy LEELSIDEMEW 1. "0 m � d o d m N O DD W O O • � � 0 1 i o .p. c 0 C.0 N SERVICE ITEM 5.4L W RADIATOR/EXHAUST OIL FILL CAP RIGHT SIDE NOTES: DISCHARGE AIR AIR INTAKE OIL DIPSTICK LEFT SIDE 1.MINIMUM RECOMMENDED CONCRETE PAD SIZE:1194(47")WIDE X 2256(88.8')LONG. (BOTH SIDES) BATTERY 12 (BOTH SIDES) OIL FILTER LEFTSIDE REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. Q GRP 26 OIL DRAIN HOSE RIGHT SIDE 2.ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE NEGATIVE GROUND RADIATOR DRAIN HOSE LEFTSIDE AND SERVICING.THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT PIN:056208 COOLANT RECOVERY BOTTLE LEFT SIDE APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, RADIATOR FILL CAP ROOFTOP STATE,AND LOCAL CODES. AIR CLEANER ELEMENT EITHER SIDE 3.CONTROL PANEL/CIRCUIT BREAKER INFORMATION: a SPARK PLUGS EITHER SIDE -SEE SPECIFICATION SHEET OR OWNERS MANUAL MUFFLER SEN 11 -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. ANE BELT EITHER SIDE e A 4.REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS D FAN BELT SEE NOTE 11 THE STUB-UP AREAS AS FOLLOWS: �E BATTERY RIGHT SIDE -HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION e r £ a NEUTRAL CONNECTION,BATTERY CHARGER 120 VOLT AC(0.5 AMP MAX)CONNECTION. REFERENCE OWNERS MANUAL -LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 508 ypyl[ FOR PERIODIC REPLACEMENT 5.CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. [20.0] �§ r �' '' PART LISTINGS. 6.BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND a r a RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7.REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8.MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 240 721.4 ►1 9.MUST ALLOW FREE FLOW OF INTAKE AIR,DISCHARGE AIR AND EXHAUST.SEE SPEC 19.41 CENTER OF GRAVITY SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. (SEE NOTE 5) 10.GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE REMOVE COVE2 AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. FOR ACCESS TO TOP VIEW 11.EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, RADIATOR FILL CAP REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH, EXHAUST MUFFLE CIRCUIT BREAKONE PER DOOR, SEE NOTE ENCLOSED WITHIN 3 759 [29.91 ONE LIFT OFF GENERATOR ENCLOSUR DOOR TYP DOOR PER SIDE OF GENERATOR �x r # # REAR 9 ' ENCLOSURE _ "t i1170 COVER PANEr s a i RADIATOR/EXHAUST ^ DISCHARGE [46.11 � TMu SEE NOTE 4 a€ ( OVERALL HEIGHT � �� 1� —CUSTOMER ACCESS ASSEMBLY,CONTROLS d �] PANELACCESS, .. k' + k s 58 BATTERY CHARGER d r -' [2.31 TYP LOCATED WITHIN [ xC 1 , pro ! e SEE NOTE 4 55 Fes—888 [35.0]—moi 47 [1.81� 1857 [73.11 TYP [2.2] 670[26.4] OVERALL WIDTH TYP 1950 [76.8]OVERALL LENGTH FUEL LINE CONNECTIO LEFT SIDE VIEW REAR VIEW 3/4"NPT FEMALE COUPLING WEIGHT DATA y ENCLOSURE WEIGHT WEIGHT SHIPPING WEIGHT - m ENGINE/KW GENSET ONLY SHIPPING SKID MATERIAL KG[LSS] KG[I.SS] KG[LBS] DIMENSIONS:MM[INCH] 5,4U48KW AL 705115551 44[98] 750[1653] �F m m n Co m pr Y/ z m m 13.5 X 29.5 6, MOUNTING SLOTS 'NOTE-STUB-UP FOR HIGH AND LOW VOLTAGE CONNECTIONS. 4X CIRCUIT BREAKER NEUTRAL AND CUSTOMER CONNECTION OPENING. O I N G7 m W n v 786 [30.9] y m _ 162 3 CD [6.4] w 'STUB-UP c� AREA r � I 12, m 12 [Al m [.5] 51 o 162 [2.0] [6.4] n 1733 [68.2] STUB-UP REMOVABLE • TOP VIEW AREA STUB-UP COVER o � 850 [33.5] H d co Z3 N C) 0 116[4.6] � 2 0 cn 50 1750 [68.9]TYP - 25 11.0 i 838 [33.0]TYP [2.0] MOUNTING SLOT CENTERS � TYP MOUNTING SLOT CENTERS TYP 1950 [76.8] 888 [35.0] REAR VIEW LEFT SIDE VIEW DIMENSIONS:MM[INCH] pCD ch �• -t = y CA? o d z co CD o R1 r N o • p C. W rnn CD � 33 W w N � n O 0 v -4 3 a