Loading...
HomeMy WebLinkAboutAPPRVD Dry HydrantFIRE PROTECTION MATERIAL SUBMITTALS FOR: FFPPLL SSOOLLAARR DDrryy HHyyddrraanntt 3650 AICO ROAD FT. PIERCE, FL 34945 Date: May 27, 2020 Our Project Number: FP-265420 Project Manager: Joe Furlong Prepared By: Thomas Bender The materials submitted represent the quality of materials specified. All materials may be substituted at this contractor’s discretion for like equivalent materials. W. W. Gay Fire & Integrated Systems, Inc. 2251 Rosselle Street / 2500 N.E. 18th Terrace Jacksonville, Florida 32204 / Gainesville, Florida 32609 904-387-7973 / 352-380-0317 15 Product Specifications System: PVC Schedule 40 Pressure Pipe and Fitting System Scope: This specification covers PVC Schedule 40 pipe and fittings for pressure applications. This system is intended for pressure applications where the operating temperature will not exceed 140°F. Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a Cell Class of 12454 as identified in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785. PVC Schedule 40 fittings shall conform to ASTM D 2466. Pipe and fittings shall be manufactured as a system and be the product of one manufacturer. All pipe and fittings shall be manufactured in the United States. Pipe and fittings shall conform to NSF International Standard 61 or the health effects portion of NSF Standard 14. Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to all applicable plumbing, building, and fire code requirements. Buried pipe shall be installed in accordance with ASTM F 1668 and ASTM D 2774. Solvent cement joints shall be made in a two step process with primer conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical agents not compatible with PVC compounds. Systems shall be hydrostatically tested after installation. WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings. Referenced Standards*: ASTM D 1784 Rigid Vinyl Compounds ASTM D 1785 PVC Plastic Pipe, Schedule 40 ASTM D 2466 PVC Plastic Fittings, Schedule 40 ASTM D 2564 Solvent Cements for PVC Pipe and Fittings ASTM D 2774 Underground Installation of Thermoplastic Pressure Piping ASTM F 656 Primers for PVC Pipe and Fittings ASTM F 1668 Procedures for Buried Plastic Pipe NSF Standard 14 Plastic Piping Components and Related Materials NSF Standard 61 Drinking Water System Components - Health Effects *Note: Latest revision of each standard applies. Short Specification: Pipe and fittings shall be manufactured from PVC compound with a cell class of 12454 per ASTM D 1784 and conform with NSF International Standards 14 and 61. Pipe shall be iron pipe size (IPS) conforming to ASTM D 1785. Fittings shall conform to ASTM D 2466. All pipe and fittings shall be produced by a single manufacturer and shall be installed in accordance with manufacturer’s recommendations and applicable code requirements. Buried pipe shall be installed in accordance with ASTM F 1668 and ASTM D 2774. Solvent cements shall conform to ASTM D 2564, primer shall conform to ASTM F 656. The system is to be manufactured by Charlotte Pipe and Foundry Company and is intended for pressure applications where the temperature will not exceed 140°F. GENERAL INFORMATION 22 Plastics Technical Manual This is to certify that all Plastic Pipe and Fittings manufactured by Charlotte Pipe and Foundry Company are manufactured in the United States and conform to the following standards: PVC SCH. 40 SOLID WALL PIPE ASTM D 1784, ASTM D 1785, ASTM D 2665 FHA UM 79a FEDERAL SPECIFICATION L-P-320a NSF STANDARD 14 AND 61 PVC SCH. 40 DWV CELLULAR CORE PIPE ASTM D 4396, ASTM F 891 NSF STANDARD NO. 14 RePVC® SCH. 40 DWV PIPE WITH RECYLED CONTENT ASTM D 4396, ASTM F 1760 NSF STANDARD NO. 14 PVC SCH. 40 DWV FITTINGS ASTM D 1784, ASTM D 2665, ASTM D 3311, ASTM F1866 FHA UM 79a FEDERAL SPECIFICATION L-P-320a NSF STANDARD NO. 14 PVC SDR-21 AND SDR-26 PRESSURE PIPE ASTM D 1784, ASTM D 2241 NSF STANDARD NO. 14 AND 61 PVC SCH. 40 PRESSURE FITTINGS ASTM D 1784, ASTM D 2466 NSF STANDARD 14 AND 61 PVC SCH. 40 WELL CASING PIPE ASTM D 1784, ASTM F 480 NSF STANDARD NO. 14 AND 61 PVC SCH. 80 PIPE ASTM D 1784, ASTM D 1785 NSF STANDARD NO. 14 AND 61 PVC SCH. 80 FITTINGS ASTM D 1784, ASTM D 2467 ASTM D 2464 ASTM F 1970 NSF STANDARD NO. 14 AND 61 PVC SDR 35 SEWER MAIN PIPE ASTM D 1784, ASTM D 3034, SDR 35 ASTM D 3212, ASTM F 477 PVC SEWER AND DRAIN PIPE ASTM D 1784, ASTM D 2729 PVC THIN WALL PIPE & FITTINGS ASTM D 1784, ASTM D 2949 NSF STANDARD NO. 14 CPVC FLOWGUARD GOLD® CTS PIPE & FITTINGS ASTM D 1784, ASTM D 2846 FHA UM-61a NSF STANDARD NO. 14 AND 61 CSA LISTED ON SPECIFIED ITEMS CPVC REUZE® CTS PIPE & FITTINGS ASTM D 1784, ASTM D 2846 NSF STANDARD NO. 14 CPVC CHEMDRAIN® SCH. 40 PIPE & FITTINGS ASTM D 1784, ASTM F 2618 NSF STANDARD 14 ABS SCH. 40 DWV CELLULAR CORE PIPE ASTM D 3965, ASTM F 628 NSF STANDARD NO. 14 cNSF® us-dwv ABS PLUS® SCH. 40 DWV CELLULAR CORE PIPE ASTM D 3965, ASTM D 4396, ASTM F 1488 ABS SCH. 40 DWV FITTINGS ASTM D 3965, ASTM D 2661, ASTM D 3311 FHA UM 79a FEDERAL SPECIFICATION L-P-322b NSF STANDARD NO. 14 CHARLOTTE PIPE AND FOUNDRY COMPANY GENERAL INFORMATION Product Certification ABS Plus, ChemDrain, ReUze and RePVC are registered trademarks of Charlotte Pipe and Foundry Company. FlowGuard Gold is a registered trademark of Lubrizol Corp. 23 Pipe Reference GuideMADEIN U .S.A. PRODUCT DATA ABS Plus, ReUze, RePVC, ChemDrain and “You can’t beat the system” are registered trademarks of Charlotte Pipe and Foundry Company. FlowGuard Gold is a registered trademark of Lubrizol Corp. Sizes Available Product 1⁄4 3⁄8 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 4 5 6 8 10 12 14 15 16 ChemDrain® CPVC Schedule 40 ★ • • • • • • FlowGuard Gold® CPVC CTS SDR 11 • • • • • • ReUze® CPVC CTS SDR 11 • • • • • PVC Schedule 80 • • • • • • • • • • • • • • • • • PVC Schedule 40 • • • • • • • • • • • • • • • • PVC Schedule 40 DWV ★ • • • • • • • • • • • • RePVC® Schedule 40 DWV with Recycled Content ★ • • • • • • PVC Schedule 30 ★ • PVC DWV Foam Core ★ • • • • • • • • PVC Well Casing • • • • • • PVC SDR 13.5 (PR315) • PVC SDR 21 (PR200) • • • • • PVC SDR 26 (PR160) • • • • PVC SDR 35 Sewer Main Belled-End ★† • • PVC SDR 35 Sewer Main Gasketed ★† • • • PVC D 2729 Sewer and Drain ★† • • ABS DWV Foam Core ★ • • • • • ABS Plus® Foam Core DWV★ • • • • ★ Non-Pressure † Not NSF Listed Notes: 1. End treatments are Plain and Belled. Consult factory for availability. 2. Lengths are 10 and 20 feet (14 and 20 feet for Gasketed Sewer Main). Consult factory for availability and non-standard lengths. 3. PVC Schedule 40 Bell End and PVC Well Casing pipe lengths for sizes 4”, 6”, and 8” are 20 feet plus the bell (20 foot laying length). 4. PVC SDR 35 Sewer Main Pipe in 14 foot lengths are 14 feet plus the bell (14 foot laying length). 29 PVC 4005 1⁄2” x 10’ 06658 .840 .109 600 PSI 15.9 PVC 4005 1⁄2” x 20’ 03922 .840 .109 600 PSI 15.9 PVC 4007 3⁄4” x 10’ 06661 1.050 .113 480 PSI 21.1 PVC 4007 3⁄4” x 20’ 03925 1.050 .113 480 PSI 21.1 PVC 4010 1” x 10’ 06664 1.315 .133 450 PSI 31.3 PVC 4010 1” x 20’ 03928 1.315 .133 450 PSI 31.3 PVC 7100* 1 1⁄4” x 10’ 03945 1.660 .140 370 PSI 42.4 PVC 7100* 1 1⁄4” x 20’ 03946 1.660 .140 370 PSI 42.4 PVC 7112* 1 1⁄2” x 10’ 03947 1.900 .145 330 PSI 50.7 PVC 7112* 1 1⁄2” x 20’ 03948 1.900 .145 330 PSI 50.7 PVC 7200* 2” x 10’ 03949 2.375 .154 280 PSI 68.1 PVC 7200* 2” x 20’ 03950 2.375 .154 280 PSI 68.1 PVC 4025‡ 21⁄2” x 20’ 04205 2.875 .203 300 PSI 108.0 PVC 7300* 3” x 10’ 03951 3.500 .216 260 PSI 141.2 PVC 7300* 3” x 20’ 03952 3.500 .216 260 PSI 141.2 PVC 7400† 4” x 10’ 03953 4.500 .237 220 PSI 201.2 PVC 7400† 4” x 20’ 03954 4.500 .237 220 PSI 201.2 PVC 7500† 5” x 20’ 04837 5.563 .258 190 PSI 272.5 PVC 7600† 6” x 10’ 03955 6.625 .280 180 PSI 353.7 PVC 7600† 6” x 20’ 03956 6.625 .280 180 PSI 353.7 PVC 7800† 8” x 10’ 13087 8.625 .322 160 PSI 532.3 PVC 7800† 8” x 20’ 03958 8.625 .322 160 PSI 532.3 PVC 7910† 10” x 20’ 03959 10.750 .365 140 PSI 754.7 PVC 7912† 12” x 20’ 03961 12.750 .406 130 PSI 997.9 PVC 7914† 14” x 20’ 04862 14.000 .437 130 PSI 1180.1 PVC 7916† 16” x 20’ 04918 16.000 .500 130 PSI 1543.1 PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 1785 MAX WORK PART NO. NOM. SIZE UPC # AVG. OD (IN.) MIN. WALL (IN.) PRESSURE WT. PER 611942- AT 23° C OR 73° F 100 FT. (LBS.) >> PVC Schedule 40 Pipe - Plain End PVC Pipe: Schedule 40 * Dual Marked ASTM D 1785 and ASTM D 2665. † Triple Marked ASTM D 1785 & ASTM D 2665 & ASTM F 480. ‡ Dual Marked ASTM D 1785 & ASTM F 480. NOTE: When ordering, please specify plain end or bell end. NSF Listed. Meets All Requirements of ASTM D 1784 and ASTM D 1785. PRODUCT DATA Testing with or use of compressed air or gas in PVC / ABS / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. • NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC pipe or fittings. • NEVER test PVC / ABS / CPVC pipe or fittings with compressed air or gas, or air over water boosters. • ONLY use PVC / ABS / CPVC pipe for water or approved chemicals. • Refer to warnings in PPFA User Bulletin 4-80 and ASTM D 1785. Schedule 80 and Schedule 40 Socket Diameter Schedule 80 Schedule 40 Nominal Entrance Bottom Tolerance Socket Length Socket Length Size A B C (Minimum) C (Minimum) 1⁄2 0.848 0.836 ±0.004 0.875 0.688 3⁄4 1.058 1.046 ±0.004 1.000 0.719 1 1.325 1.310 ±0.005 1.125 0.875 11⁄4 1.670 1.655 ±0.005 1.250 0.938 11⁄2 1.912 1.894 ±0.006 1.375 1.094 2 2.387 2.369 ±0.006 1.500 1.156 21⁄2 2.889 2.868 ±0.007 1.750 1.750 3 3.516 3.492 ±0.008 1.875 1.875 4 4.518 4.491 ±0.009 2.250 2.000 6 6.647 6.614 ±0.011 3.000 3.000 8 8.655 8.610 ±0.015 4.000 4.000 10 10.780 10.735 ±0.015 5.000 5.000 12 12.780 12.735 ±0.015 6.000 6.000 Scope: This specification covers PVC Schedule 40 pipe and fittings for pressure applications. This system is intended for pressure applications where the operating temperature will not exceed 140° F. Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a cell class of 12454 as identified in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785. Injection molded PVC Schedule 40 fittings shall conform to ASTM D 2466. Pipe and fittings shall be manufactured as a system and be the product of one manufacturer. All pipe and fittings shall be manufactured in the United States. Pipe and fittings shall conform to NSF International Standard 61 and the health-effects portion of NSF Standard 14. Installation: Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to all applicable plumbing, fire, and building code requirements. Buried pipe shall be installed in accordance with ASTM F 1668. Solvent cement joints shall be made in a two-step process with primer conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, fire-stopping materials, thread sealant, plasticized-vinyl products or other aggressive chemical agents not compatible with PVC compounds. The system shall be hydrostatically tested after installation. WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings. Doing so can result in explosive failures and cause severe injury or death. Referenced Standards: ASTM D 1784: Rigid Vinyl Compounds ASTM D 1785: PVC Plastic Pipe, Schedule 40 ASTM D 2466: PVC Plastic Fittings, Schedule 40 ASTM D 2564: Solvent Cements for PVC Pipe and Fittings SUBMITTAL FOR CHARLOTTE PIPE® PVC SCHEDULE 40 PRESSURE PIPE AND FITTING SYSTEM Charlotte Pipe and Charlotte Pipe and Foundry Company are registered trademarks of Charlotte Pipe and Foundry Company. FO-SUB-PVC-40 (5-30-19) Date: ________________ Job Name: ______________________________ Location: _______________________________ Engineer: _______________________________ Contractor: ______________________________ Not all fitting patterns shown Bushing Plug Cap Street Quarter BendCrossEighth BendQuarter Bend Male Adapter Charlotte Pipe and Foundry Company • P.O. Box 35430 Charlotte, NC 28235 • (800) 438-6091 • www.charlottepipe.com ASTM F 1668: Procedures for Buried Plastic Pipe NSF Standard 14: Plastic Piping Components & Related Materials NSF Standard 61: Drinking Water System Components – Health Effects Tee Coupling Female Adapter Schedule 40 Tapered Socket Dimensions PVC SCHEDULE 40 - ASTM D 2466 Sizes Available Product 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 4 5 6 8 10 12 14 16 PVC Schedule 40 • • • • • • • • • • • • • • • • PIPE REFERENCE GUIDE M A DE IN U .S.A. Technical Specification Purple Primer – NSF Listed Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 1 of 3 Description • Purple-tinted aggressive primer for use on PVC and CPVC pipe and fittings. • Lo-V.O.C. Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements. • Removes surface dirt, grease and grime as well as softens the pipe surface to allow a fast, secure solvent weld. • For use in areas where plumbing code calls for verification that a primer has been used. • N SF and IAPMO Listed. • Meets ASTM F656. Listings NSF Standard 61 for PW, DWV and Sewer Waste IAPMO Listed Maximum VOC per SCAQMD 1168/316A or BAAQMD Method 40: 550 g/L INGREDIENTS (CAS Number) Acetone (67-64-1), Cyclohexanone (108-94-4), Methyl Ethyl Ketone (78-93-3), Red Dye (4477-76-6) Violet Dye (81-48-1), Tetrahydrofuran (109-99-9) MSDS Number: 1402E Product Number Size Qty Wgt Product Number Size Qty Wgt 30755 4 oz. 24 8 lbs. 307553 4 oz. 48 8 lbs. 30756 30757 30758 30759 8 oz. 16 oz. 32 oz. Gallon 24 24 12 6 14 lbs. 25 lbs. 24 lbs. 46 lbs. 307563 307573 307583 8 oz. 16 oz. 32 oz. 36 10 6 14 lbs. 25 lbs. 24 lbs. Technical Specification Purple Primer – NSF Listed Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 2 of 3 CHEMICAL PROPERTIES Appearance Density Shelf Life Purple Liquid 6.97 ± 0.2 lbs/gallon 3 Years from Mfg. Date Precautions Read all information carefully before using this product. DANGER!: CAUSES SERIOUS EYE IRRITATION. HARMFUL IF INHALED. MAY CAUSE DROWSINESS OR DIZZINESS. MAY CAUSE RESPIRATORY IRRITATION. REPEATED EXPOSURE MAY CAUSE SKIN DRYNESS OR CRACKING. Long term overexposure to solvents may cause damage to the brain, nervous system, reproductive system, respiratory system, mucous membranes, liver and kidneys. Contains a chemical classified by the US EPA as a suspected possible carcinogen. KEEP OUT OF REACH OF CHILDR EN. PRECAUTIONS: Avoid breathing vapors. Use only outdoors or in a well-ventilated area. Use explosion-proof electrical/ventilating equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Wear a NIOSH-approved respirator for organic solvents. Keep away from heat/sparks/open flames/hot surfaces. No smoking. Vapors may accumulate in low places and may ignite explosively. Keep container tightly closed and cool. Wear protective gloves and eye protection. Wash thoroughly after handling. Do not eat or drink while using this product. EMERGENCY/FIRST AID: CALL 1-877-740-5015 FOR INSTRUCTIONS. IF SWALLOWED: Immediately call a POISON CENTER/doctor. Do NOT induce vomiting. Rinse mouth. This product may be aspirated into the lungs and cause chemical pneumonitis, a potentially fatal condition. If IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical attention. If ON SKIN: Rinse skin with water/shower. Take off immediately all contaminated clothing. If INHALED: Remove person to fresh air and keep comfortable for breathing. Call POISON CENTER/doctor if you feel unwell. If medical advice is needed, have product container or label at hand. FIRE: Use dry chemical, foam, or carbon dioxide extinguisher. Water spray may be applied to reduce potential vapors or for cooling. Burning liquid extinguished with water will _oat and may re-ignite on surface of water. SPILLS: Remove all sources of ignition and ventilate area. Personnel cleaning up the spill should wear appropriate personal protective equipment, including respirators if vapor concentrations are high. Soak up spill with absorbent material. Put absorbent material in covered, labeled metal containers. Dispose of contents/ container in accordance with local regulations. Store in a well-ventilated space. Store locked up. Technical Specification Purple Primer – NSF Listed Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 3 of 3 Directions for Use Store and use at temperatures between -15°F and 110°F. At temperatures outside of this range, special care must be taken to prepare good joints and prevent exposure to solvents. Stir or shake before using; if jelly-like, don’t use. Do not thin. Handle with care! Will stain most materials and surfaces. 1. Cut pipe ends square, chamfer and clean pipe ends. 2. Check dry fit of pipe and fitting. Pipe should easily go 1/3 of the way into the fitting. If pipe bottoms, it should be snug. 3. Use a suitable applicator at least 1/2 the size of the pipe diameter. For larger size pipe systems use a natural bristle brush or roller. 4. Apply thoroughly to inside of the fitting socket and to the outside surface of the pipe to the depth of the fitting. Apply a second coat of primer to fitting socket. 5. While primer is still wet use an appropriate solvent cement for the pipe being joined. Follow application instructions from cement can. DO NOT TEST WITH AIR. Revision Date: 3/15/2013 Technical Specification Regular Clear PVC Cement Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 1 of 3 Description  Regular-Bodied Clear cement for use on all schedules and classes of PVC pipe and fittings up to 4” for Sch. 40 and up to 2” for Sch. 80.  Lo-V.O.C. Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements.  Recommended for potable water, pressure pipe, conduit and DWV.  Recommended application temperature 40°F to 110°F / 4°C to 43°C.  Meets ASTM D-2564. Listings NSF Standard 61 for PW, DWV and Sewer Waste IAPMO Listed Maximum VOC per SCAQMD 1168/316A or BAAQMD Method 40: 510 g/L INGREDIENTS (CAS Number) Acetone (67-64-1), Amorphous Silica (112945-52-5), Cyclohexanone (108-94-4), Methyl Ethyl Ketone (78-93-3), PVC Resin (9002-86-2), Tetrahydrofuran (109-99-9) MSDS Number: 1100E Product Number Size Qty Wgt Product Number Size Qty Wgt 31012 4 oz. 24 9 lbs. 310123 4 oz. 48 8 lbs. 31013 8 oz. 24 15 lbs. 310133 8 oz. 36 15 lbs. 31014 16 oz. 24 28 lbs. 310143 16 oz. 10 28 lbs. 31015 32 oz. 12 27 lbs. 310153 32 oz. 6 27 lbs. 31016 Gallon 6 50 lbs. Technical Specification Regular Clear PVC Cement Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 2 of 3 CHEMICAL PROPERTIES PHYSICAL PROPERTIES Appearance Viscosity Density Shelf Life Clear Liquid Min. 90 cps @73° F ± 2° F 7.47 ± 0.2 lbs/gallon 3 years from manufacture date Lap Shear Strength 2 hours 16 hours 72 hours Set Up Time 30° F to 50° F 50° F to 70° F 70° F to 90° F (min. ASTM Standards) 250 psi 500 psi 900 psi 6 – 7 minutes 4 – 5 minutes 1 – 3 minutes Precautions Read all information carefully before using this product. DANGER!: CAUSES SERIOUS EYE IRRITATION. HARMFUL IF INHALED. MAY CAUSE DROWSINESS OR DIZZINESS. MAY CAUSE RESPIRATORY IRRITATION. REPEATED EXPOSURE MAY CAUSE SKIN DRYNESS OR CRACKING. Long term overexposure to solvents may cause damage to the brain, nervous system, reproductive system, respiratory system, mucous membranes, liver and kidneys. Contains a chemical classified by the US EPA as a suspected possible carcinogen. KEEP OUT OF REACH OF CHILDREN. PRECAUTIONS: Avoid breathing vapors. Use only outdoors or in a well-ventilated area. Use explosion- proof electrical/ventilating equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Wear a NIOSH-approved respirator for organic solvents. Keep away from heat/sparks/open flames/hot surfaces. No smoking. Vapors may accumulate in low places and may ignite explosively. Keep container tightly closed and cool. Wear protective gloves and eye protection. Wash thoroughly after handling. Do not eat or drink while using this product. EMERGENCY/FIRST AID: CALL 1-877-740-5015 FOR INSTRUCTIONS. IF SWALLOWED: Immediately call a POISON CENTER/doctor. Do NOT induce vomiting. Rinse mouth. This product may be aspirated into the lungs and cause chemical pneumonitis, a potentially fatal condition. If IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical attention. If ON SKIN: Rinse skin with water/shower. Take off immediately all contaminated clothing. If INHALED: Remove person to fresh air and keep comfortable for breathing. Call POISON CENTER/doctor if you feel unwell. If medical advice is needed, have product container or label at hand. FIRE: Use dry chemical, foam, or carbon dioxide extinguisher. Water spray may be applied to reduce potential vapors or for cooling. Burning liquid extinguished with water will _oat and may re-ignite on surface of water. SPILLS: Remove all sources of ignition and ventilate area. Personnel cleaning up the spill should wear appropriate personal protective equipment, including respirators if vapor concentrations are high. Soak up spill with absorbent material. Put absorbent material in covered, labeled metal containers. Dispose of contents/ container in accordance with local regulations. Store in a well-ventilated space. Store locked up. Technical Specification Regular Clear PVC Cement Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 3 of 3 Directions for Use Store and use at temperatures between 40°F and 110°F. At temperatures outside of this range, special care must be taken to prepare good joints and prevent exposure to solvents. Stir or shake before using; if jelly-like, don’t use. Do not thin. 1. Cut pipe ends square, chamfer and clean pipe ends. 2. Check dry fit of pipe and fitting. Pipe should easily go 1/3 of the way into the fitting. If pipe bottoms, it should be snug. 3. Use a suitable applicator at least 1/2 the size of the pipe diameter. For larger size pipe systems use a natural bristle brush or roller. 4. Clean pipe and fitting with a listed primer. 5. Apply liberal coat of cement to pipe to the depth of the socket, leave no uncoated surface. 6. Apply a thin coat of cement to inside of fitting, avoid puddling of cement. Puddling can cause weakening and premature failure of pipe or fitting. Apply a second coat of cement to the pipe. 7. Assemble parts QUICKLY. Cement must be fluid. If cement surface has dried, recoat both parts. 8. Push pipe FULLY into fitting using a ¼ turning motion until pipe bottoms. 9. Hold pipe and fitting together for 30 seconds to prevent pipe push-out - longer at low temperatures. Wipe off excess. 10. Allow 15 minutes for good handling strength and 2 hours cure time at temperatures above 60°F before pressure testing up to 180 psi. Longer cure times may be required at temperatures below 60°F or with pipe above 3". DO NOT TEST WITH AIR. Revision Date: 3/15/2013