HomeMy WebLinkAboutAPPRVD ELEV_MCHNE RM PLNHATCH ELEVATIONSCALE: 3/8" = 1'RAIL BRACKET SPACING
30'-8"
12'-8" OVERHEAD114'-0" TOTAL TRAVEL
9" OVERRUN
4'-0"
PIT DEPTH
3'-7"
REFUGE
CLEARANCE
ALT. FL. OFEGRESS 2ndPITLADDER3'-6" x 7'-0" FINISHED
CLEAR OPENING
7'-4" X FULL
WIDTH OF HATCH
8'-1" OVERALL
CAB HEIGHT
8'-0" CAB HEIGHT
2'-2"8'-2"SUMP PUMP PIT, PUMP, AND OIL SEPARATOR BY OTHERS3'-10"
3'-6" x 7'-0" FINISHED
CLEAR OPENING
7'-4" X FULL
WIDTH OF HATCH
3'-63
8"2R2"6'-8"3'-63
8"3'-63
8"3'-63
8"G.C. PROVIDE HOISTINGBEAM 4000#8'-2"8'-2"FLOOR OFEGRESS 2nd3'-10"3'-10"3'-10"S/SL SILLELEVATOR FLOORING DETAILNOTE:FLOOR BY OTHERS______" THICKNESSFLOORMOUNTINGANGLECABWALLSHIMSSCALE: 2" = 1'CONCRETEANCHOR TYP.GROUT FILLBY G.C.5"3
4"
13
4"SINGLE SLIDE SILL DETAILSCALE: 2" = 1'SCALE: 3/8" = 1'PIT DETAILPLATFORM ATFLOOR LEVEL3" RUNBYRT = 12910 lbf4'-0"PIT DEPTH 8'-0" CAB HEIGHT7'-0" CLEAR OPENING10'-6" STILE LENGTHVIEW A3'-6"6"412"6"CONTRACTOR NOTE:8" X 8" BLOCKOUTREQUIRED IN WALL FOROIL LINE COORDINATELOCATION WITH FIELDSUPERVISOR.3'-0"x 6'-8"CLEAR OPEN POWER UNIT36"W x 24"D x 36" H8"x 8" BLOCKOUT REQ'D,IN WALL FOR OIL LINECOORDINATE LOCATIONWITH MECO SUPERVISORELEVATION 41-1/2"EC CONTROLLER36" X 8-1/2 x 32STOIL LINE DIA. 2"LIGHT SWITCH ANDLIGHTS BY G.C.NOTE:MACHINE ROOMCEILING HT.7'-0" MINIMUMNOTE:18" CLEARANCE FORMAINTENANCE INFRONT OF UNIT ANDMUFFLER SIDETOTAL HEAT LOAD = 8806 BTU/HR** NOTICE **COORDINATE EXACTPLACEMENT OFEQUIPMENT ,WITH MECOSUPERVISOR ON JOB SITE20 HP MOTOR69 FL AMPS1P CAB LIGHTS DISCONNECT30 AMP BY G.C. 3P MOTORDISCONNECT BY G.C. MACHINE ROOMSCALE: 1/2" = 1' ADJACENT @ 2ND FLOOR7'-4"6'-8"8'-8" CLEAR HOISTWAY3'-6" X 7'-0" FINISHEDCLEAR DOOR OPENING2'-7"2'-7"10"10"7'-1" DBL7'-2" DBG3'-0"
6'-8" CLEAR HOISTWAY3'-6"5'-10" CLEAR HATCH5" SILL PROJECTION
5'-71
2" PLATFORM11
4" RUNING CLEARANCE
3'-41
4"
3'-51
2"
TO HATCH SILL LINEIMPORTANT EMERG.4'-31
2" CLEAR INSIDE CAR6'-938" CLEAR INSIDE CARCORRIDORPUSH BUTTON, TYPLIGHT SWITCH &LIGHTS BY G.C.PIT SWITCHCONTRACTOR NOTE:8" X 8" BLOCKOUTREQUIRED IN WALL FOROIL LINE COORDINATELOCATION WITH FIELDSUPERVISOR.7'-0" PLATFORM3'-6" X 7'-0" FINISHEDCLEAR DOOR OPENINGFRONTREARCAR STATIONEXIT20" x 20"SUMP PUMP& PIT BYOTHERSPIT LIGHT TYP.PIT LADDERSCALE 1/2" = 1'HATCH PLAN412"7'-9" DISTANCE BETWEEN JACKS4'-10" ROUGH OPENING1'-11"1'-11"6716"6716"3'-101
2"
101
2"
1'-814"1'-114"CLEAROPENING3'-21316"4"4"7'-4"ROUGHOPENING HEIGHT 4'-10" ROUGHOPENING WIDTH8"3'-6"HALL STATION CUTOUT SEESIDE FOR SIZE REQUIRED.LOCATE FROM BOTTOM OFCUTOUTS TO FINISHED FLOOR.HALL STATIONCUTOUT USEON FLOORS1HALL STATIONCUTOUT USEON FLOORS2FIXTURE CUTOUT ELEVATIONSCALE: 1/4" = 1'NOTE:AS SHOWNFOR ACENTEROPENINGIF POSSIBLE DO NOT BUILD FRONT WALL UNTIL ENTRANCE FRAMESARE ERECTED IF NOT POSSIBLE ROUGH OPENINGS AS SHOWNGROUT FILLBY G.CJAMB DETAILSCALE: 2" = 1'75
8"
8"
101
4"2"2"3
4"3
4"NOTE:ADEQUATE SUPPORT IN FRONTWALL OF HOISTWAY FOR FRAMEMOUNTING ANGLES. COORDINATEWITH MECO SUPERVISOR202 lbf129 lbfF1F2SCALE: 4"= 1'RAIL LOADINGRAIL SIZE = 8 #2 7
16"4/21/207511DWG SHEET 1 0F 1REVISIONSMOWREY ELEVATOR CO. INC.CONTRACT ENGINEERING FACILITYMARIANNA, FLORIDA - HYDRAULIC ELEVATOR- PLANS AND DETAILSVARIESDATE:SCALE:ASME A17.1 -2013DATE APPLIEDSUBAPPROVED FOR CONSTRUCTIONAPPROVED FOR MANUFACTURINGGOVERNING CODE: THE PURCHASER PROVIDES THE FOLLOWING REQUIREMENTS BASED ON AMERICANNATIONAL STD. SAFETY CODE A17.1 EXC. WHEN RELEVANT CODES INCLUDESTRICTER RULES CONFLICTING WITH A17.1 REFERRED RULES ARE ANSI A17.1, NEC,FAC 61C-5, NFPA72 1. CLEAR PLUMB HOISTWAY. VARIATION NOT EXCEED 1" THE 1ST 100 FT. W/ INCREASE OF 1/32" FOR EACH ADDITIONAL 10' MAX. DISPLACEMENT ALLOWED 2" 2. HOISTWAY ENCLOSURES SHALL CONFORM TO CODE 2.1.1.1, 2.1.1.2, OR 2.1.1.3 3. HOISTWAY ENCLOSURES SHALL HAVE FLUSH SURFACES ON THE HOISTWAY SIDE,SUBJECT TO THE REQUIREMENTS OF 2.1.6.1 AND 2.1.6.2 4. VENTING OF HOISTWAY (RULE 2.1.4) 5. ADEQUATE SUPPORTS FOR RAIL BRACKETS: MAXIMUM SPACING AS SHOWN USE DIVIDER BEAMS INTERMEDIATE SUPPORTS AND/OR RAIL BACKING WHEN SPACING IS EXCEEDED (RULE 2.23.9) 6. ADEQUATE REINFORCED PIT TO SUPPORT VERTICAL FORCES FROM RAILS AND BUFFERS (RULE 106-16 1002.2A)WITH A 32" X32" BLOCK OUT FOR JACK INSTALLATION AND TO BE GROUTED AFTER JACK IS SET. 7. VENTILATION AND HEATING OF MACHINE ROOM AND MACHINERY SPACE PER RULE (RULE 2.7.5) . MAINTAIN TEMPERATURE BETWEEN 70 - 90 DEGREES FAHRENHEIT. 8. TELEPHONE LINE FOR EACH ELEVATOR MACH. ROOM CONNECTED TO CONTROLLER. 9. A PERMANENT LIGHTING FIXTURE SHALL BE PROVIDED AND SHALL CONFORM TO2.2.5.1 - 2.2.5.3 10. LADDER FOR EACH ELEVATOR PIT PER CODE. 4'-0" ABOVE 1ST LANDING. 11. REMOTE MACHINE ROOM - PROVIDED CLEAR ACCESS ABOVE CEILING OR FURNISHED TRENCH IN FLOOR FOR OIL LINE AND WIRING DUCT FROM PUMP (MACH) ROOM TO ELEVATOR HOISTWAY. 12. PROVIDE LEGAL ACCESS TO HOISTWAY PIT AND MACHINE ROOM. (RULE 2.7.3) 13. PROVIDE 8" X 8" CUTOUT THROUGH WALL FOR OIL LINE AND WIRING DUCT. ACTUAL LOCATION TO BE COORDINATED WITH FIELD REPRESENTATIVE AT JOB SITE. 14. CUTOUTS AND BLOCK OUTS THRU WALL TO ACCOMMODATE CORRIDOR PUSH BUTTONS BOXES, SIGN EQUIPMENT AN FOLLOW - UP PATCHING 15. PROVIDE REMOVABLE BARRICADES AT ALL OPENINGS. 16. A FUSED DISCONNECT SWITCH-CURCUIT BREAKER FOR EACH ELEVATOR. LOCATE PER NATIONAL ELECTRICAL CODE. REFER TO ELEVATOR LAYOUT FOR LOCATION. NFPA # 70 RULE 620-51. 17. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION REQUIRED PER 2002 NEC #620-85 ON MACHINE ROOM. 18. SMOKE AND HEAT DETECTORS AS REQUIRED BY THE ASME A17.1,NFPA72 AND LOCAL CODE REQUIREMENTS. 19. THIS INSTALLATION COMPLIES WITH SECTION 399. FAC 61C-5 AND NEC-2009. GENERAL CONTRACTOR PURCHASE NOTES 1. PROVIDE UNOBSTRUCTED ACCESS FOR DRILLING EQUIPMENT OF JACK. IF PIT IS NOT POURED, REFERENCE BENCH MARKS ARE TO BE FURNISHED BY OWNER 2. ADEQUATE SPACE FOR HATCH DOOR/DOORS OPERATING EQUIPMENT. 3. HOISTWAY DOORS ARE 1-1/2 HOUR FIRE RATING. 4. HATCH WALLS SHOULD HAVE A FIRE RESISTANT RATING - ASME A17.1 ELEVATOR SAFETY CODE RULE 2.1.1 5. NECESSARY GROUTING AND PATCHING BY G.C. 6. LEAVE 24" X 24" HOLE IN ROOF UNTIL JACK IS SET. 7. PROVIDE CRANE FOR HOISTING. 8. SUMP PUMP, PIPING AND ELECTRICAL BY G.C.20. SUMP PUMP REQUIRED PER ASME A17.1 2.2.2.5. DESIGNED PER FBC 3004.4 AND FBC 712.3.2 .22. THIS INSTALLATION COMPLIES WITH CHAPTER 30 OF THE FLORIDA BUILDING CODE, NFPA 70 FT. PIERCE, FL. FPL OBSERVATION 2950 ALCO RD.CURINGTON CONTRACTING LLC.3-7511BUILDING:LOCATION:GENERAL CONTRACTOR:CONTRACT NO.: PASSENGERMER-2503503907345250L20UC4M1-1/2" 7" 9"5200#69 AMP208V 3PSIMPLEX2214'-0"100/1002500UND. OILSPRINGCHANNEL2300#SOLIDSELECTIVE COLLECTIVEELEVATOR SPECIFICATIONS AND DATAJACK UNIT SIZEWORK PRESSUREFEED LINE - GPMJACK PRESSUREH. P.PUMP SIZETYPE POWER UNITCARCARSTROKEBUFFER TYPEBLOCKINGVALVETRAVELCAPACITYOPENINGSSTOPSCONTROLCAR SPEED UP/DNRUNNING LOADPOWER SUPPLYGUIDE SHOESOPERATIONTYPECAR WEIGHTBOTTOM OV.TRAV.TOP OV. TRAVELGROSS WEIGHTLIGHTING SUPPLYCAR 1CAR 1110 VAC21. SCAFFOLDING IF REQUIRED BY OTHERS.