HomeMy WebLinkAboutAPPRVD ENCODE REV 5-14-20Florida Building Code, Sixth Edition (2017) - Energy Conservation
EnergyGauge Summit® Fla/Com-2017, Effective Date: Dec 31, 2017
ASHRAE 90.1-2013 - Energy Cost Budget Option
Check List
Applications for compliance with the Florida Building Code, Energy Conservation shall
include:
ff This Checklist
Ij The full compliance report generated by the software that contains the project
summary, compliance summary, certifications and detailed component compliance
reports.
FM The compliance report must include the full input report generated by the software as
contigous part of the compliance report.
I Boxes appropriately checked in the Mandatory Section of the complaince report_
EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 1 of 29
PROJECT SUMMARY
Short Desc: FPL East
Owner: Florida Power & Light
Addresst: FPL East Operations Center at Interstate Solar
Address2: 3650 AIC Road
Description: FPL East Operations Center
City:
State:
Zip:
Type: Office Class:
Jurisdiction: FORT PIERCE, ST LUCIE COUNTY, FL (661100)
Conditioned Area: 6160 SF Conditioned & UnConditioned Area:
No of Stories: 1 Area entered from Plans
Permit No: 0 Max Tonnage
If different, write in:
Ft Pierce
FL
34945
New Finished building
6160 SF
6160 SF
5
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 2 of 29
Compliance Summary
Component Design Criteria Result
Gross Energy Cost (in $) 3,142.0 4,947.0 PASSED
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
PASSES
PASSES
No Entry
PASSES
PASSES
Yes/No/NA
IMPORTANT MESSAGE
Info 5009 -- -- -- An input report of this design building must be submitted along with this
Compliance Report
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 3 of 29
CERTIFICATIONS
I hereby certify that the plans and specifications covered by this calculation are in compliance with the
Florida Energy Code
Prepared By: Miller Professional Engineerir Building Official:
Date: 4 &12; D Date:
certify that this building is in compliance with the FLorida Energy Efficiency Code
Owner Agent: Florida Power & Light Date:
If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida
Energy Efficiency Code
Architect: HtA' Barrineau & Associates, I Reg No: FI,
Electrical Designer: Miller Professional F,ngineerir Reg No: Fl,
Lighting Designer: Miller Professional Engineerix Reg No: FI,
Mechanical Designer: Miller Professional EnganeeriT Reg No: FL
Plumbing Designer: Miller Professional Engineerir Reg No: EL
Signature is required where Florida Law requires design to be performed by registered design
professionals. Typed names and registration numbers may be used where all relevant information is
contained on signed/sealed plans -
a tt h e DigitallyDN: c=Us,
signed by Matthew Miller
DN: c=US, st=Florida, 1=0cala,
o=Miller Professional Engineering,
111, cn=Matthew Miller,
w M i l l e r 101 c04'00' Date:20 0.05125 6:11l.1 MATTHEV,% r >,+ '
EER, P.E. P.E.
LICENSE fJL MdER 66499 EnergyGauge Summit&
Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 orida Building
Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic 5/1/
2020 Page 4 of 29
Project: FPL East
Title: FPL East Operations Center
Type: Office
WEA File: FL_ST_LUCIE_CO_INTL.tm3)
Building End Uses
1) Proposed 2) Baseline
Total 203.40 317.38
3,142 4, 947
ELECTRICITY(MBtu/kWh 203.40 317.38
59622 92994
3,142 4,947
AREA LIGHTS 39.10 71.70
11469 21012
604 1,118
MISC EQUIPMT 84.80 84.80
24851 24851
1,310 1,322
PUMPS & MISC 0.50 0.45
135 132
7 7
SPACE COOL 46.30 80.68
13557 23634
714 1,257
SPACE HEAT 1.10 3.73
337 1090
18 58
VENT FANS 31.60 76.03
9273 22275
489 1,185
Credits Applied: None PASSES
Passing Criteria = 4947
Design (including any credits) = 3142
Passing requires Proposed Building cost to be at most 100% of
Baseline cost. This Proposed Building is at 63.5%
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 5 of 29
Project: FPL East
Title: FPL East Operations Center
Type: Office
WEA File: FL_ST_LUCIE_CO_INTL.tm3)
External Lighting Compliance
Description Category Tradable? Allowance Area or Length ELPA CLP
W/Unit) or No. of Units W) (W)
Sgft or ft)
Ext Light 1 Building facades (by linear foot) No 3.75 332.0 1,245 400
Ext Light 2 Main entries Yes 30.00 15.0 450 100
Ext Light 3 Other (doors) than main entries Yes 20.00 12.0 240 50
Tradable Surfaces: 150 (W) Allowance for Tradable: 1440 (W) PASSES
All External Lighting: 550 (W)
Complicance check includes a excess/Base allowance of 750.00(W)
Project: FPL East
Title: FPL East Operations Center
Type: Office
WEA File: FL ST LUCIE CO INTL.tm3)
Lighting Controls Compliance
Acronym Ashrae Description Area Design Min Compliance
ID (sq.ft) CP CP
1-SW Offices 17 Office - Enclosed 2,015 15 1 PASSES
2-NE Offices 17 Office - Enclosed 2,070 18 1 PASSES
3-Large Conf 15 Conference/meeting (Multiple 1,218 5 1 PASSES
Functions)
4-Garage 3 Storage & Warehouse - Bulky 520 2 1 PASSES
Active Storage
5-Small Conf 15 Conference/meeting (Multiple 273 2 1 PASSES
Functions)
6-Machine 1 Electrical Mechanical Equipment 64 2 1 PASSES
Room - General
PASSES
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/l/2020 Page 6 of 29
Project: FPL East
Title: FPL East Operations Center
Type: Office
WEA File: FL_ST_LUCIE_CO_INTL.tm3)
System Report Compliance
1-SW System 1 Constant Volume Air Cooled No. of Units
Offices Split System < 65000 Btu/hr 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Conditioners Air 60000 20.00 13.00 8.00 PASSES
Cooled Split System <
65000 Btu/h Cooling
Capacity
Heating System Heat Pumps Air Cooled 60000 10.00 8.20 PASSES
Heating Mode) Split
System < 65000 Btu/h
Cooling Capacity
Air Handling Air Handler (Supply) - 2000 0.50 0.82 Not Required
System -Supply Constant Volume
Air Distribution Not in Check list - 6.00 6.00 N/A
System (Sup) Compliance Ignored
2-NE System 2 Constant Volume Air Cooled No. of Units
Offices Split System < 65000 Btu/hr 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Conditioners Air 60000 20.00 13.00 8.00 PASSES
Cooled Split System <
65000 Btu/h Cooling
Capacity
Heating System Heat Pumps Air Cooled 60000 10.00 8.20 PASSES
Heating Mode) Split
System < 65000 Btu/h
Cooling Capacity
Air Handling Air Handler (Supply) - 2000 0.50 0.82 Not Required
System -Supply Constant Volume
Air Distribution Not in Check list - 6.00 6.00 N/A
System (Sup) Compliance Ignored
3-Large System 3 Constant Volume Air Cooled No. of Units
Conf Split System < 65000 Btu/hr 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Conditioners Air 60000 20.00 13.00 8.00 PASSES
Cooled Split System <
65000 Btu/h Cooling
Capacity
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/l/2020 Page 7 of 29
Heating System Heat Pumps Air Cooled 60000 10.00 8.20 PASSES
Heating Mode) Split
System < 65000 Btu/h
Cooling Capacity
Air Handling Air Handler (Supply) - 2000 0.50 0.82 Not Required
System -Supply Constant Volume
Air Distribution Not in Check list - 6.00 6.00 N/A
System (Sup) Compliance Ignored
4-Garage System 4 Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Conditioners Air 24000 20.50 13.00 8.00 PASSES
Cooled Split System <
65000 Btu/h Cooling
Capacity
Heating System Heat Pumps Air Cooled 24000 10.00 8.20 PASSES
Heating Mode) Split
System < 65000 Btu/h
Cooling Capacity
Air Handling Air Handler (Supply) - 550 0.50 0.82 Not Required
System -Supply Constant Volume
5-Small System 5 Constant Volume Air Cooled No. of Units
Conf Split System < 65000 Btu/hr 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Conditioners Air 15000 19.80 13.00 8.00 PASSES
Cooled Split System <
65000 Btu/h Cooling
Capacity
Heating System Heat Pumps Air Cooled 15000 11.20 8.20 PASSES
Heating Mode) Split
System < 65000 Btu/h
Cooling Capacity
Air Handling Air Handler (Supply) - 350 0.50 0.82 Not Required
System -Supply Constant Volume
6-Machine System 6 Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/l/2020 Page 8 of 29
Cooling System Air Conditioners Air 12000 23.10 13.00 8.00 PASSES
Cooled Split System <
65000 Btu/h Cooling
Capacity
Heating System Electric Furnace 1 1.00 1.00 PASSES
Air Handling Air Handler (Supply) - 200 0.50 0.82 Not Required
System -Supply Constant Volume
PASSES
Plant Compliance
Description Installed Size Design Min Design Min Category Comp
No Eff Eff IPLV IPLV liance
None
Project: FPL East
Title: FPL East Operations Center
Type: Office
WEA File: FL_ST_LUCIE_CO_INTL.tm3)
Water Heater Compliance
Description Type Category
Design Min Design Max Comp
Eff Eff Loss Loss liance
Water Heater 1 Electric water heater <= 12 [kW] 0.96 0.96 PASSES
PASSES
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/l/2020 Page 9 of 29
Project: FPL East
Title: FPL East Operations Center
Type: Office
WEA File: FL_ST_LUCIE_CO_INTL.tm3)
Piping System Compliance
Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compl-
inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] iance
F] SF.F]
Domestic and Service Hot Water 1.25 False 110.00 0.27 1.00 0.50 PASSES
Systems
Domestic and Service Hot Water 0.50 False 110.00 0.27 1.00 0.50 PASSES
Systems
PASSES
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 10 of 29
Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department
of Energy and Pacific Northwest National Laboratory.
Adopted with permission
Topic Section Component Description Yes NIA Exempt
1. To be checked by Designer or Engineer
Insulation 5.8.1.2 Envelope Below -grade wall insulation installed per 0 0manufacturers€Ims instructions.
Insulation 5.8.1.2 Envelope Slab edge insulation installed per manufacturers ICJ 0Tansinstructions.
Insulation 5.5.3.5 Envelope Slab edge insulation depthilength.
Insulation 6A.4.1.5 Envelope Bottom surface of floor structures incorporating 13 12f
radiant heating insulated to >=R-3.5-
Fenestration 5.5.3.6 Envelope U-factor of opaque doors associated with the
building thermal envelope meets requirements.
SYSTEM —SPECIFIC 6.5.1, 6.5.1.1, Mechanical Air economizers provided where required (and not Q
6.5.1.3, 6.5.1.4 exempted), meet the requirements for design
capacity, control signal, ventilation controls,
high -limit shut-off, integrated economizer control,
and provide a means to relieve excess outside air
during operation.
6.5.1, 6.5.1.2, Mechanical Water economizers provided where required, El
6.5.1.3 meet the requirements for design capacity,
maximum pressure drop and integrated
economizer control..
SYSTEM —SPECIFIC 6.5.1.5 Mechanical Economizer operation will not increase heating 1:3 El
energy use during normal operation.
SYSTEM —SPECIFIC 6.5.2.2.1 Mechanical Three -pipe hydronic systems using a common
return for hot and chilled water are not used.
SYSTEM —SPECIFIC 6.5.2.2.3 Mechanical Hydronic heat pump systems connected to a
common water loop meet heat rejection and heat
addition requirements.
SYSTEM —SPECIFIC 6.5.1.6 Mechanical Water economizer specified on hydronic cooling
and humidification systems designed to maintain
inside humidity at >35 A°F dewpoint if an
economizer is required.
SYSTEM —SPECIFIC 6.5.3.1.1 Mechanical HVAC fan systems at design conditions do not 0 0
exceed allowable fan system motor nameplate hp
or fan system bhp.
SYSTEM —SPECIFIC 6.5.3.1.2 Mechanical HVAC fan motors not larger than the first available
motor size greater than the bhp.
HVAC 6.5.6.1 Mechanical Exhaust air energy recovery on systems meeting E
Tables 6.5.6.1-1, and 6.5.6.1-2.
SYSTEM —SPECIFIC 7.4.2 Mechanical Service water heating equipment meets efficiency 0",El Q
requirements.
SYSTEM 7.5.2 Mechanical Service water heating equipment used for space MSPECIFIC
heating complies with the service water heating
equipment requirements.
Insulation 5.8.1.2 Envelope Above -grade wall insulation installed per IE 13
manufacturers€7R°s instructions.
Insulation 5.8.1.2 Envelope Floor insulation installed per manufacturers€Tms 13 ID
instructions.
Controls 10.4.3 Mechanical Elevators are designed with the proper lighting, 0 0
ventilation power, and standby mode.
SYSTEM 6.4.1.1. 6.8.1-7a Mechanical Heat Rejection Equipment: Minimum EfficiencySPECIFIC
Requirement Table 6.8.1-7
SYSTEM 6.4.1.1, 6.8.1-7b Mechanical Heat Rejection Equipment: Minimum Efficiency El EZ( SPECIFIC
Requirement Table 6.8.1-7
SYSTEM 6.4.1.1, 6.8.1-7c Mechanical Heat Rejection Equipment: Minimum Efficiency aSPECIFIC
RequirementTable 6.8.1-7
SYSTEM 6.4.1.1, 6.8.1-7d Mechanical Heat Rejection Equipment: Minimum EfficiencySPECIFIC
Requirement Table 6.8.1-7
EnergyGauge 5ummitV Fla/Gom-ZUI 1. [AM 1U1 I-1.0 uompllant sotrware. LTrecnve uate: uec a i, cu i i
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
511l2020 Page 11 of 29
SYSTEM -SPECIFIC 6.5.5.3 Mechanical Centrifugal fan open -circuit cooling towers having
combined rated capacity — 1100 gpm meets
minimum efficiency requirement: Table 6.8.1-7
SYSTEM -SPECIFIC 6.4.1.1, 6.8,1-7e Mechanical Heat Rejection Equipment: Minimum Efficiency W,
Requirement Table 6.8.1-7
SYSTEM -SPECIFIC 6.4.1.1. 6.8.1-7f Mechanical Heat Rejection Equipment: Minimum Efficiency d
Requirement Table 6.8.1-7
SYSTEM -SPECIFIC 6.4.1.1, 6.8.1-7g Mechanical heat Rejection Equipment: Minimum Efficiency
Requirement Ta ble 6.8.1-7.
SYSTEM -SPECIFIC 6.4.1.1, 6.8.1-7h Mechanical heat Rejection Equipment: Minimum Efficiency 13 El Requirement Table 6.8.1-7
SYSTEM -SPECIFIC 6.4.1.1, 6.8.1-7i Mechanical Heat Rejection Equipment: Minimum Efficiency
Requirement Table 6.8.1-7
SYSTEM -SPECIFIC 7.5.3 Mechanical Gas -fired water -heating equipment installed in
new buildings: where a singular piece of
water -heating equipment — 1,000 kBtulh serves
the entire building, thermal efficiency must be 3=
90 Et.
Where multiple pieces of water -heating equipment
serve the building with combined rating is ?=
1,000 kBtuih, the combined
input -capacity -weighted -average thermal
efficiency, thermal efficiency must be — 90 EL
Exclude input rating of equipment in individual
dwelling units and equipment <- 100 kBtulh.
2. To be checked by Plan Reviewer
Plan Review 4.2.2, 5.4.3.1.1, 5.7 Envelope Plans andlor specifications provide all information 00 0
with which compliance can be determined for the
building envelope and document where
exceptions to the standard are claimed.
Plan Review 4.2.2, 6.4.4.2.1, Mechanical Plans, specifications, andlor calculations provide El 13
6.7.2 all information with which compliance can be
determined for the mechanical systems and
equipment and document where exceptions to the
standard are claimed. Load calculations per
acceptable engineering standards and
handbooks.
Plan Review 4.2.2, 7.7.1, 10.4.2 Mechanical Plans, specifications, andlor calculations provide
all information with which compliance can be
determined for the service water heating systems
and equipment and document where exceptions
to the standard are claimed. Hot water system
sized per manufacturer's sizing guide.
Plan Review 4.2.2, 8.4.1.1, Project Plans, specifications, andlor calculations provide 0
8.4.12, 8.7 all information with which compliance can be
determined for the electrical systems and
equipment and document where exceptions are
claimed. Feeder connectors sized in accordance
with approved plans and branch circuits sized for
maximum drop of 3%.
Plan Review 4.2.2, 9.4.3, 9.7 Interior Lighting Plans, specifications, and/or calculations provide 0
all information with which compliance can be
determined for the interior lighting and electrical
systems ,and equipment and document where
exceptions to the standard are claimed.
Information provided should include interior
lighting power calculations, wattage of bulbs and
ballasts, transformers and control devices.
Plan Review 9.7 Exterior Lighting Plants, specifications, andlor calculations provide 00
all information with which compliance can be
determined for the exterior lighting and electrical
systems and equipment and document where
exceptions to the standard are claimed.
Information provided should include exterior
lighting power calculations, wattage of bulbs and
ballasts, transformers and control devices.
Insulation 5.8.1.7.3 Envelope Insulation in contact with the ground has <=0.3%
water absorption rate per ASTM C272.
EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 12 of 29
Air Leakage 5.4.3.4 Envelope Vestibules are installed where building entrances
separate conditioned space from the exterior, and
meet exterior envelope requirements. Doors have
self -closing devices, and are > 7 ft apart (> 16 ft
apart for adjoinging floor area — 40000 sq.ft.).
Vestibule floor area < 7 50 sq.ft. or 2 percent of
the adjoining conditioned floor area.
HVAC 6.4.3.4.4 Mechanical Ventilation fans >0.75 hp have automatic controls
to shut off fan when not required.
HVAC 6.4.3.8 Mechanical Demand control ventilation provided for spaces
500 ft2 and >25 people/1000 ft2 occupant
density and served by systems with air side
economizer, auto modulating outside air damper
control, or design airflow >3,000 cfm.
HVAC 6.4.4.1.4 Mechanical Thermally ineffective panel surfaces of sensible
heating panels have insulation — R-3.5.
HVAC 6.5.2.3 Mechanical Dehumidification controls provided to prevent
reheating, recooling, mixing of hot and cold
airstreams or concurrent heating and cooling of
the same airstream.
SYSTEM —SPECIFIC 6.5.3.1.3 Mechanical Fans have efficiency grade (FEG) — 67. The total
efficiency of the fan at the design point of
operation — 15% of maximum total efficiency of
the fan.
SYSTEM —SPECIFIC 6.5.3.5 Mechanical Motors for fans — 1/12 hp and < 1 hp are El
electronically -commutated motors or have a
minimum motor efficiency of 70%. These motors
are also speed adjustable for either balancing or
remote control.
SYSTEM —SPECIFIC 6.4.3.10 Mechanical DDC system installed and capable of providing
control logic including monitoring zone and system
demand for fan pressure, pump pressure, heating,
and cooling; transferring zone and system
demand information from zones to air distribution
system controllers and from air distribution
systems to heating and cooling plant controllers;
automatically detecting and alerting system
operator when zones and systems excessively
drive the reset logic; allow operator removal of
zone(s) from the reset algorithm; AND capable of
trending and graphically displaying input and
output points.
SYSTEM —SPECIFIC 6.5.3.2.3 Mechanical Reset static pressure setpoint for DDC controlled
VAV boxes reporting to central controller based on
the zones requiring the most pressure. Controls
provide: zone damper monitoring or indicator of
static pressure need; autodetection, alarm, and
operator override of zones excessively triggering
reset logic.
SYSTEM —SPECIFIC 6.5.3.3 Mechanical Multiple zone VAV systems with DDC of individual
zone boxes have static pressure setpoint reset
controls.
SYSTEM —SPECIFIC 6.5.3.4 Mechanical Multiple zone HVAC systems have supply air
temperature reset controls.
SYSTEM —SPECIFIC 6.5.4.1 Mechanical System turndown requirement met through
multiple single -input boilers, one or more
modulating boilers, or a combination of
single -input and modulating boilers.
Boiler input between 1.0 MBtu/h and 5 MBtu/h has
3:1 turndown ratio, boiler input between 5.0
MBtu/h and 10 MBtu/h has 4:1 turndown ratio,
boiler input > 10.0 MBtu/h has 5:1 turndown ratio.
HVAC 6.5.4.2 Mechanical HVAC pumping systems >10 hp designed for
variable fluid flow.
SYSTEM —SPECIFIC 6.5.4.3, 6.5.4.3.1, Mechanical Fluid flow shutdown in pumping systems to
6.5.4.3.2 multiple chillers or boilers when systems are shut
down.
SYSTEM —SPECIFIC 6.5.4.4 Mechanical Temperature reset by representative building
loads in pumping systems >10 hp for chiller and
boiler systems >300,000 Btu/h.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 13 of 29
SYSTEM —SPECIFIC 6.5.4.5.2 Mechanical Hydronic heat pumps and water-cooled unitary air
conditioners with pump systems >5 hp have
controls or devices to reduce pump motor
demand.
SYSTEM —SPECIFIC 6.5.4.6 Mechanical Chilled -water and condenser water piping sized El M
according to design flow rate and total annual
hours of operation (Table 6.5.4.6).
SYSTEM —SPECIFIC 6.5.5.2.1 Mechanical Fan systems with motors —7.5 hp associated 1:1 El
with heat rejection equipment to have capability to
operate at 2/3 of full -speed and auto speed
controls to control the leaving fluid temperature or
condensing temp/pressure of heat rejection
device.
SYSTEM —SPECIFIC 6.5.5.2.2 Mechanical Multicell heat rejection equipment with 0
variable -speed fan drives installed that operate
the maximum number of fans allowed that comply
with manufacturers specs and control all fans to
the same fan speed required for the instantaneous
cooling duty.
SYSTEM —SPECIFIC 6.5.5.2.3 Mechanical NA 1-1 El
HVAC 6.5.7.1.1 Mechanical Kitchen hoods >5,000 cfm have make up air
50% of exhaust air volume.
HVAC 6.5.7.1.1 Mechanical Kitchen hoods >5,000 cfm have make up air
50% of exhaust air volume.
SYSTEM —SPECIFIC 6.5.7.1.2 Mechanical Conditioned supply air to space with a kitchen
hood shall not exceed the greater of a) supply flow
required to meet space heating or cooling, or b)
hood exhaust flow minus the available air transfer
from available spaces.
SYSTEM —SPECIFIC 6.5.7.1.3 Mechanical Kitchen hoods with a total exhaust airflow rate El
5000 cfm meet replacement air, ventilation
system, or energy recovery requirements shown in
Table 6.5.7.1.3.
SYSTEM —SPECIFIC 6.5.7.1.4 Mechanical Kitchen hoods with a total exhaust airflow rate El El
5000 cfm meet replacement air, ventilation
system, or energy recovery requirements.
HVAC 6.5.7.2 Mechanical Fume hoods exhaust systems —5,000 cfm have
VAV hood exhaust and supply systems, direct
make-up air or heat recovery.
HVAC 6.5.8.1 Mechanical Unenclosed spaces that are heated use only
radiant heat.
SYSTEM —SPECIFIC 7.5.1 Mechanical Combined space and water heating system not
allowed unless standby loss less than calculated
maximum. AHJ has approved or combined
connected load <150 kBtu/h.
Controls 8.4.2 Project At least 50% of all 125 volt 15- and 20-Amp
receptacles are controlled by an automatic control
device.
Other Equipment 10.4.1 Mechanical Electric motors meet requirements where
applicable.
HVAC 6.4.3.3.2 Mechanical Setback controls allow automatic restart and El
temporary operation as required for maintenance.
SYSTEM —SPECIFIC 6.4.3.3.3 Mechanical Systems with setback controls and DDC include
optimum start controls. Optimum start algorithm
considers mass radiant slab floor temperature.
SYSTEM —SPECIFIC 6.4.3.3.4 Mechanical Zone isolation devices and controls.
Wattage 9.4.2 Exterior Lighting Exterior lighting power is consistent with what is El El
shown on the approved lighting plans,
demonstrating proposed watts are less than or
equal to allowed watts.
3. To be checked by Inspector
Insulation 5.8.1.7 Envelope Exterior insulation protected against damage,
sunlight, moisture, wind, landscaping and
equipment maintenance activities.
HVAC 6.4.3.7 Mechanical Freeze protection and snow/ice melting system
sensors for future connection to controls.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 14 of 29
Air Leakage 5.4.3.1 Envelope Continuous air barrier is wrapped, sealed,
caulked, gasketed, and/or taped in an approved
manner, except in semiheated spaces in climate
zones1-6.
Air Leakage 5.4.3.2 Envelope Factory -built and site -assembled fenestration and
doors are labeled or certified as meeting air
leakage requirements.
Fenestration 5.8.2.1, 5.8.2.3, Envelope Fenestration products rated (U-factor, SHGC, and
5.8.2.4, 5.8.2.5 VT) in accordance with NFRC or energy code
defaults are used.
Fenestration 5.8.2.2 Envelope Fenestration and door products are labeled, or a 0
signed and dated certificate listing the U-factor,
SHGC, VT, and air leakage rate has been
provided by the manufacturer.
SYSTEM —SPECIFIC 7.4.4.1 Mechanical Temperature controls installed on service water
heating systems (<=120A°F to maximum
temperature for intended use).
SYSTEM —SPECIFIC 7.4.4.2 Mechanical Automatic time switches installed to automatically
switch off the recirculating hot-water system or
heat trace.
SYSTEM —SPECIFIC 7.4.6 Mechanical Heat traps installed on non -circulating storage
water tanks.
HVAC 6.4.1.4, 6.4.1.5 Mechanical HVAC equipment efficiency verified. Non-NAECA
HVAC equipment labeled as meeting 90.1.
SYSTEM —SPECIFIC 6.4.1.5.2 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. El
labeled for replacement only.
HVAC 6.4.3.4.1 Mechanical Stair and elevator shaft vents have motorized El
dampers that automatically close.
HVAC 6.4.3.4.2, 6.4.3.4.3 Mechanical Outdoor air and exhaust systems have motorized El El
dampers that automatically shut when not in use
and meet maximum leakage rates. Check gravity
dampers where allowed.
HVAC 6.4.3.4.5 Mechanical Enclosed parking garage ventilation has automatic
contaminant detection and capacity to stage or
modulate fans to 50% or less of design capacity.
HVAC 6.5.3.2.1 Mechanical DX cooling systems — 75 kBtu/h (> 65 kBtu/h
effective 1/2016) and chilled -water and
evaporative cooling fan motor hp >= A'/o designed
to vary indoor fan airflow as a function of load and
comply with operational requirements.
HVAC 6.4.4.1.1 Mechanical Insulation exposed to weather protected from
damage. Insulation outside of the conditioned
space and associated with cooling systems is
vapor retardant.
HVAC 6.4.4.1.2 Mechanical HVAC ducts and plenums insulated. Where ducts
or plenums are installed in or under a slab,
verification may need to occur during Foundation
Inspection.
HVAC 6.4.4.1.3 Mechanical HVAC piping insulation thickness. Where piping is El
installed in or under a slab, verification may need
to occur during Foundation Inspection.
HVAC 6.4.4.2.1 Mechanical Ducts and plenums sealed based on static El
pressure and location.
SYSTEM —SPECIFIC 6.4.4.2.2 Mechanical Ductwork operating >3 in. water column requires
air leakage testing.
SYSTEM —SPECIFIC 6.5.2.1 Mechanical Zone controls can limit simultaneous heating and
cooling and sequence heating and cooling to each
zone.
SYSTEM —SPECIFIC 6.5.2.2.2 Mechanical Two -pipe hydronic systems using a common
distribution system have controls to allow a
deadband > 15 A°F, allow operation in one mode
for at least 4 hrs before changeover, and have
rest controls to limit heating and cooling supply
temperature to < 30 A°F.
HVAC 6.5.2.4.1 Mechanical Humidifiers with airstream mounted preheating
jackets have preheat auto -shutoff value set to
activate when humidification is not required.
HVAC 6.5.2.4.2 Mechanical Humidification system dispersion tube hot
surfaces in the airstreams of ducts or air -handling
units insulated — R-0.5.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 15 of 29
SYSTEM —SPECIFIC 6.5.3.2.2 Mechanical VAV fans have static pressure sensors positioned
so setpoint —1.2 in. w.c. design pressure.
SYSTEM —SPECIFIC 6.5.4.5.1 Mechanical Two -position automatic valve interlocked to shut
off water flow when hydronic heat pump with
pumping system >10 hp is off.
SYSTEM —SPECIFIC 6.5.6.2 Mechanical Condenser heat recovery system that can heat
water to 85 A°F or provide 60% of peak heat
rejection is installed for preheating of service hot
water.
HVAC 6.5.7.1.5 Mechanical Approved field test used to evaluate design air
flow rates and demonstrate proper capture and
containment of kitchen exhaust systems.
SYSTEM —SPECIFIC 6.5.9 Mechanical Hot gas bypass limited to:
240 kBtu/h a€" 15%
240 kBtu/h a€" 10%
HVAC 6.4.3.9 Mechanical Heating for vestibules and air curtains include
automatic controls that shut off the heating system
when outdoor air temperatures > 45F. Vestibule
heating systems controlled by a thermostat in the
vestibule with setpoint — 60F.
Controls 6.5.10 Mechanical Doors separating conditioned space from the
outdoors have controls that disable/reset heating
and cooling system when open.
Controls 9.4.1.1 Interior Lighting Automatic control requirements prescribed in
Table 9.6.1, for the appropriate space type, are
installed. Mandatory lighting controls (labeled as
REQ') and optional choice controls (labeled as
ADD1' and 'ADD2') are implemented.
Controls 9.4.1.1 Interior Lighting Independent lighting controls installed per
approved lighting plans and all manual controls
readily accessible and visible to occupants.
Controls 9.4.1.2 Interior Lighting Parking garage lighting is equipped with required
lighting controls and daylight transition zone
lighting.
Controls 9.4.1.1f Interior Lighting Daylight areas under skylights and roof monitors
that have more than 150 W combined input power
for general lighting are controlled by
photocontrols.
Controls 9.4.1.4 Exterior Lighting Automatic lighting controls for exterior lighting
installed.
Controls 9.4.1.3 Interior Lighting Separate lighting control devices for specific uses
installed per approved lighting plans.
Wattage 9.6.2 Interior Lighting Additional interior lighting power allowed for
special functions per the approved lighting plans
and is automatically controlled and separated from
general lighting.
Wattage 9.6.4 Interior Lighting Where space LPD requirements are adjusted
based on room cavity ratios, dimensions are
consistent with approved plans.
Insulation 5.5.3.1 Envelope Roof R-value. For some ceiling systems,
verification may need to occur during Framing
Inspection.
Insulation 5.8.1.2, 5.8.1.3 Envelope Roof insulation installed per manufacturers€TMs
instructions. Blown or poured loose -fill insulation
is installed only where the roof slope is < 3 in 12.
Insulation 5.8.1.1 Envelope Building envelope insulation is labeled with
R-value or insulation certificate has been provided
listing R-value and other relevant data.
Insulation 5.8.1.9 Envelope Building envelope insulation extends over the full
area of the component at the proposed rated R or
U value.
Insulation 5.8.1.4 Envelope Eaves are baffled to deflect air to above the
insulation.
Insulation 5.8.1.5 Envelope Insulation is installed in substantial contact with El
the inside surface separating conditioned space
from unconditional space.
Insulation 5.8.1.6 Envelope Recessed equipment installed in building
envelope assemblies does not compress the
adjacent insulation.
Insulation 5.8.1.7.1 Envelope Attics and mechanical rooms have insulation
protected where adjacent to attic or equipment
access.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 16 of 29
Insulation 5.8.1.7.2 Envelope Foundation vents do not interfere with insulation.
Insulation 5.8.1.8 Envelope Insulation intended to meet the roof insulation
requirements cannot be installed on top of a
suspended ceiling. Mark this requirement
compliant if insulation is installed accordingly.
SYSTEM —SPECIFIC 6.4.3.1.1 Mechanical Heating and cooling to each zone is controlled by
a thermostat control.
HVAC 6.4.3.1.2 Mechanical Thermostatic controls have a 5 A°F deadband.
HVAC 6.4.3.2 Mechanical Temperature controls have setpoint overlap
restrictions.
HVAC 6.4.3.3.1 Mechanical HVAC systems equipped with at least one
automatic shutdown control.
SYSTEM —SPECIFIC 6.4.3.5 Mechanical Heat pump controls prevent supplemental electric El
resistance heat from coming on when not needed.
HVAC 6.4.3.6 Mechanical When humidification and dehumidification are
provided to a zone, simultaneous operation is
prohibited. Humidity control prohibits the use of
fossil fuel or electricity to produce RH > 30% in the
warmest zone humidified and RH < 60% in the
coldest zone dehumidified.
HVAC 6.4.3.6 Mechanical When humidification and dehumidification are
provided to a zone, simultaneous operation is
prohibited. Humidity control prohibits the use of
fossil fuel or electricity to produce RH > 30% in the
warmest zone humidified and RH < 60% in the
coldest zone dehumidified.
SYSTEM —SPECIFIC 7.4.4.3 Mechanical Public lavatory faucet water temperature <=110A
F.
SYSTEM —SPECIFIC 7.4.4.4 Mechanical Controls are installed that limit the operation of a El
recirculation pump installed to maintain
temperature of a storage tank.
SYSTEM —SPECIFIC 7.4.5.1 Mechanical Pool heaters are equipped with on/off switch and El
no continuously burning pilot light.
SYSTEM —SPECIFIC 7.4.5.2 Mechanical Pool covers are provided for heated pools and
pools heated to >90A°F have a cover >=R-12.
SYSTEM —SPECIFIC 7.4.5.3 Mechanical Time switches are installed on all pool heaters and
pumps.
Wattage 9.2.2.3 Interior Lighting Interior installed lamp and fixture lighting power is
consistent with what is shown on the approved
lighting plans, demonstrating proposed watts are
less than or equal to allowed watts.
SYSTEM —SPECIFIC 7.4.3 Mechanical All piping in circulating system insulated
SYSTEM —SPECIFIC 7.4.3 Mechanical First 8 ft of outlet piping is insulated El
SYSTEM —SPECIFIC 7.4.3 Mechanical All heat traced or externally heated piping
insulated
4. To be checked by Inspector at Project Completion and Prior to Issuance of
Certificate of Occupancy
Plan Review 6.7.2.4 Mechanical Detailed instructions for HVAC systems
commissioning included on the plans or
specifications for projects > 50,000 ft2.
Plan Review 6.7.2.4 Mechanical Detailed instructions for HVAC systems
commissioning included on the plans or
specifications for projects > 50,000 ft2.
Post Construction 6.7.2.1 Mechanical Furnished HVAC as -built drawings submitted
within 90 days of system acceptance.
Post Construction 6.7.2.2 Mechanical Furnished O&M manuals for HVAC systems within
90 days of system acceptance.
Post Construction 6.7.2.3 Mechanical An air and/or hydronic system balancing report is El
provided for HVAC systems serving zones >5,000
ft2 of conditioned area.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 17 of 29
HVAC 6.7.2.4 Mechanical HVAC control systems have been tested to ensure
proper operation, calibration and adjustment of
controls.
Post Construction 8.7.1 Interior Lighting Furnished as -built drawings for electric power
systems within 30 days of system acceptance.
Post Construction 8.7.2 Interior Lighting Furnished O&M instructions for systems and
equipment to the building owner or designated
representative.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 18 of 29
Input Data Report
Proiect Information
Project Name: FPL East Project Title: FPL East Operations Center
Address: FPL East Operations Center at Interstate State: FL Zip: 34945
Solar
Owner: Florida Power & Light
Building Type: Office Building Classification: New Finished building
No.of Stories: 1 GrossArea (SF): 6,160
Bldg. Rotation: None
Zones
No Acronym Description Type Area Multi Total Area
sf] sfJ
1 1-SW Offices Zone 1 CONDITIONED 2015.0 1 2015.0
2 2-NE Offices Zone 2 CONDITIONED 2070.0 1 2070.0
3 3-Large Conf Zone 3 CONDITIONED 1218.2 1 1218.2
4 4-Garage Zone 4 CONDITIONED 520.0 1 520.0
5 5-Small Conf Zone 5 CONDITIONED 273.0 1 273.0
6 6-Machine Zone 6 CONDITIONED 64.0 1 64.0
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 19 of 29
Spaces
No Acronym Description
In Zone: 1-SW Offices
I 1-SW Offices 1-SW Offices
In 'Zone: 2-NE Offices
I 2-NE Offices 2-NE Offices
In Zone: 3-Large Conf
I 3-Large Conf 3-Large Conf
In Zone: 4-Garage
I 4-Garage 4-Garage
In Zone: 5-Small Conf
1 5-Small Conf 5-Small Conf
In Zone: 6-Machine
1 6-Machine 6-Machine
Type Depth
ft]
Office - Enclosed 31.00
Office - Enclosed 23.00
Conference/meeting (Multiple 27.07
Functions)
Storage & Warehouse - Bulky 20.00
Active Storage
Conference/meeting (Multiple 13.00
Functions)
Electrical Mechanical 8.00
Equipment Room - General
Width Height Mult Total Total
ft] [ft] Area Vol[cf]
65.00 15.00 1 2015.0 30225.0
90.00 15.00 1 2070.0 31050.0
45.00 15.00 1 1218.2 18272.3
26.00 15.00 1 520.0 7800.0
21.00 15.00 1 273.0 4095.0
8.00 15.00 1 64.0 960.0
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 20 of 29
Lighting
No Type Category No. of Watts per Power Control Type No.of
Luminaires Luminaire [W] Ctrl pts
In Zone: 1-SW Offices
In Space: 1-SW Offices
1 LED General Lighting
2 LED General Lighting
In Zone: 2-NE Offices
In Space: 2-NE Offices
1 LED General Lighting
2 LED General Lighting
3 LED General Lighting
4 LED General Lighting
5 LED General Lighting
In Zone: 3-Large Conf
In Space: 3-Large Conf
1 LED General Lighting
2 LED General Lighting
In Zone: 4-Garage
In Space: 4-Garage
1 LED General Lighting
In Zone: 5-Small Conf
In Space: 5-Small Conf
1 LED General Lighting
In Zone: 6-Machine
In Space: 6-Machine
1 LED General Lighting
30 32 960 Occupancy sensor without 13
Daylighting
1 26 26 Occupancy sensor without 2
Daylighting
26 32 832 Occupancy sensor without 9
Daylighting
2 26 52 Occupancy sensor without 3
Daylighting
5 40 200 Occupancy sensor without 2
Daylighting
2 42 84 Occupancy sensor without 2
Daylighting
2 18 36 Occupancy sensor without 2
Daylighting
16 56 896 Occupancy sensor without 4
Daylighting
2 18 36 Occupancy sensor without 1
Daylighting
3 89 267 Occupancy sensor without 2
Daylighting
4 56 224 Occupancy sensor without 2
Daylighting
4 33 132 Occupancy sensor without 2
Daylighting
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/l/2020 Page 21 of 29
Walls (Walls will be rotated clockwise by building rotation value)
No Description Type Width H (Effec) Multi Area Orient Cond- Heat Dens. R-Value
ft] ft] plier sf] ation uctance Capacity lb/cf] h.sf.F/Btu]
Btu/h.sf.Fl [Btu/sf.F]
In Zone: 1-SW Offices
1 1-SW Offices W Metal 65.00 15.00 1 975.0 West 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
9Batt/5/8"Gyp
2 1-SW Offices Sd Metal 31.00 15.00 1 465.0 South 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
9Batt/5/8"Gyp
In Zone: 2-NE Offices
1 2-NE Offices E Metal 90.00 15.00 1 1350.0 East 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
2 2-NE Offices N Metal 9.00 10.00 1 90.0 North 0.0514 0.682 9.99 19.5
siding/2x4@24"+R1
913att/5/8"Gyp
In Zone: 3-Large Conf
1 3-Large Conf W Metal 6.00 4.00 4 24.0 West 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
2 3-Large Conf N Metal 30.00 15.00 1 450.0 North 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
In Zone: 4-Garage
1 4-Garage S Metal 26.00 15.00 1 390.0 South 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
2 4-Garage E Metal 20.00 15.00 1 300.0 East 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
In Zone: 6-Machine
1 6-Machine N Metal 8.00 15.00 1 120.0 North 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
2 6-Machine W Metal 8.00 15.00 1 120.0 West 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
3 6-Machine E Metal 8.00 15.00 1 120.0 East 0.0514 0.682 9.99 19.5
siding/2x4@24"+Rl
913att/5/8"Gyp
EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 22 of 29
Windows (Windows will be rotated clockwise by building rotation value)
No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area
Btu/hr sf F] IN [ft] plier [sf]
In Zone: 1-SW Offices
In Wall: 1-SW Offices S
1 1-SW Offices S South
In Wall: 1-SW Offices W
1 1-SW Offices W West
In Zone: 2-NE Offices
In Wall: 2-NE Offices E
1 2-NE Offices E East
2 2-NE Offices E East
In Wall: 2-NE Offices N
1 2-NE Offices N North
In Zone: 3-Large Conf
In Wall: 3-Large Conf N
1 3-Large Conf N North
In Zone: 4-Garage
In Wall: 4-Garage E
1 4-Garage E East
No 0.9000 0.68 0.66 2.50 3.00 1 7.5
No 0.9000 0.68 0.66 4.00 4.00 6 96.0
No 0.9000 0.68 0.66 4.00 4.00 3 48.0
No 0.9000 0.68 0.66 2.50 3.00 1 7.5
No 0.9000 0.68 0.66 2.00 3.00 2 12.0
No 0.9000 0.68 0.66 6.00 4.00 2 48.0
No 0.9000 0.68 0.66 4.00 4.00 1 16.0
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 23 of 29
Doors
No Description Type Shade? Width H (Effec) Multi Area Cond. Dens. Ht Cap. R
ft] [ft] plier [sf] [Btu/h.sLF] [Ib/cf] [Btu/sL [h.sLF/
F] Btu]
In Zone: 1-SW Offices
In Wall: 1-SW Offices S
1 1-SW Offices S Solid Urethane foam No 3.00
core
In Zone: 2-NE Offices
In Wall: 2-NE Offices E
1 2-NE Offices E Solid Urethane foam No 3.00
core
In Wall: 2-NE Offices N
1 2-NE Offices N Solid Urethane foam No 3.00
core
In Zone: 4-Garage
In Wall: 4-Garage S
1 4-Garage S Solid Urethane foam No 3.00
core
2 4-Garage S Solid Urethane foam No 12.00
core
In Zone: 6-Machine
In Wall: 6-Machine E
1 6-Machine E Solid Urethane foam No 3.00
core
7.00 1 21.0 0.2410 0.00 0.00 4.15
7.00 1 21.0 0.2410 0.00 0.00 4.15
7.00 2 21.0 0.2410 0.00 0.00 4.15
7.00 1 21.0 0.2410 0.00 0.00 4.15
12.00 1 144.0 0.2410 0.00 0.00 4.15
7.00 1 21.0 0.2410 0.00 0.00 4.15
Roofs
No Description Type Width
IN
H (Effec)
ft]
Multi
plier
Area
sf]
Tilt
deg]
Cond.
Btu/h.Sf. F]
Heat Cap Dens. R-Value
Btu/sf. F] [lb/cf] [h.sf.F/Btu
In Zone: 1-SW Offices
1 1-SW Offices Mtl Bldg Roof/R-38 65.00 31.00 1 2015.0 0.00 0.0261 1.45 5.85 38.3
Batt
In Zone: 2-NE Offices
1 2-NE Offices Mtl Bldg Roof/R-38 90.00 23.00 1 2070.0 0.00 0.0261 1.45 5.85 38.3
Batt
In Zone: 3-Large Conf
1 3-Large Conf Mtl Bldg Roof/R-38 45.00 28.00 1 1260.0 0.00 0.0261 1.45 5.85 38.3
Batt
In Zone: 4-Garage
1 4-Garage Mtl Bldg Roof/R-38 26.00 20.00 1 520.0 0.00 0.0261 1.45 5.85 38.3
Batt
In Zone: 5-Small Conf
1 5-Small Conf Mtl Bldg Roof/R-38 21.00 13.00 1 273.0 0.00 0.0261 1.45 5.85 38.3
Batt
In Zone: 6-Machine
1 6-Machine Mtl Bldg Roof/R-38 8.00 8.00 1 64.0 0.00 0.0261 1.45 5.85 38.3
Batt
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 24 of 29
Skylights
No Description Type U SHGC Vis.Trans W H (Effec) Multi- Area Total Area
Btu/hr sf F] [ft] [ft] plier [Sf] [Sf]
In Zone:
In Roof:
M
Floors
No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value
ft] ft] plier sf] Btu/h.sLF [Btu/sf. F] lb/cf] [h.sf.F/Btu
In Zone: 1-SW Offices
1 1-SW Offices 1 ft. soil, concrete 65.00 31.00 1 2015.0 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
In Zone: 2-NE Offices
1 2-NE Offices 1 ft. soil, concrete 90.00 23.00 1 2070.0 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
In Zone: 3-Large Conf
1 3-Large Conf 1 ft. soil, concrete 45.00 28.00 1 1260.0 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
In Zone: 4-Garage
1 4-Garage 1 ft. soil, concrete 26.00 20.00 1 520.0 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
In Zone: 5-Small Conf
1 5-Small Conf 1 ft. soil, concrete 21.00 13.00 1 273.0 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
In Zone: 6-Machine
1 6-Machine 1 ft. soil, concrete 8.00 8.00 1 64.0 0.2681 34.00 113.33 3.73
floor, carpet and
rubber pad
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 25 of 29
Systems
1-SW Offices System 1 Constant Volume Air Cooled No. Of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Efficiency IPLV
1 Cooling System 60000.00 20.00 8.00
2 Heating System 60000.00 10.00
3 Air Handling System -Supply 2000.00 0.50
4 Air Distribution System (Sup) 6.00
2-NE Offices System 2 Constant Volume Air Cooled No. Of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Efficiency IPLV
1 Cooling System 60000.00 20.00 8.00
2 Heating System 60000.00 10.00
3 Air Handling System -Supply 2000.00 0.50
4 Air Distribution System (Sup) 6.00
3-Large Conf System 3 Constant Volume Air Cooled No. Of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Efficiency IPLV
1 Cooling System 60000.00 20.00 8.00
2 Heating System 60000.00 10.00
3 Air Handling System -Supply 2000.00 0.50
4 Air Distribution System (Sup) 6.00
4-Garage System 4 Constant Volume Air Cooled No. Of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Efficiency IPLV
1 Cooling System 24000.00 20.50 8.00
2 Heating System 24000.00 10.00
3 Air Handling System -Supply 550.00 0.50
5-Small Conf System 5 Constant Volume Air Cooled No. Of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Efficiency IPLV
1 Cooling System 15000.00 19.80 8.00
2 Heating System 15000.00 11.20
3 Air Handling System -Supply 350.00 0.50
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 26 of 29
6-Machine System 6 Constant Volume Air Cooled No. Of Units
Split System < 65000 Btu/hr 1
Component Category Capacity Efficiency IPLV
1 Cooling System
2 Heating System
3 Air Handling System -Supply
12000.00 23.10 8.00
1.00 1.00
200.00 0.50
Plant
Equipment Category Size Inst.N&ff. 1PLV
Water Heaters
W-Heater Description Capacity Cap.Unit UP Rt. Efficiency Loss
1 Electric water heater 40 [Gal] 6 [kW] 0.9600 [Ef] [Btu/h]
Ext-Lighting
Description Category No. of Watts Area/Len/No Control Wattage
Lumin- per [sf/ft/No] Type [W]
aires Lumin-
a Ext Light 1
2 Ext Light 2
3 Ext Light 3
Building facades (by linear 8 50 332.00 Photo Sensor contr( V###
foot)
Main entries 5 20 15.00 Photo Sensor contri #####:
Other (doors) than main 1 50 12.00 Photo Sensor contri 50.00
entries
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 27 of 29
Piping
Operating Insulation Nomonal pipe Insulation Is
No Type
Temp Conductivity Diameter Thickness Runout?
F] [ Btu-in/h.sf.F] in] in]
1 Domestic and Service Hot Water 110.00 0.27 1.25 1.00 No
Systems
2 Domestic and Service Hot Water 110.00 0.27 0.50 1.00 No
Systems
Fenestration Used
Glass
Name Glass Type No. of SHGC VLT
Conductance
Panes
Btu/h.sf.F]
ASHULDb1C1rM User Defined 2 0.9000 0.6800 0.6600
tl-Oth frm
Materials Used
Only RValue Thick Cond- Density Sp. HeatMatNoAcronymDescription
R-Value [h.sf.F/Btu] IN uctivity lb/cf] Btu/lb.F
Used Btu/h.ft.F
187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000
BOARD,1 /2IN
178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300
265 Matl265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000
48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000
12 Matl12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000
23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000
4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000
288 Mat1288 Solid Urethane foam core Yes 4.1500
94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500
3/8IN
407 Matl407 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000
414 Mat1414 R-8 generic Insulatrion No 8.0000 0.1746 0.0218 0.30 0.2000
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 28 of 29
Constructs Used
Simple Massless Conductance Heat Cap Density RValue
No Name Construct Construct Btu/h.sLF] [Btu/sLF] lb/cf] h.sLF/Btu]
1019 Metal No No 0.05 0.68 9.99 19.5
siding/2x4@24"+R19Batt/5/8"Gyp
Layer Material Material Thickness Framing
No. ft] Factor
1 4 Steel siding 0.0050 0.000
2 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000
3 407 R-19 Generic Insulation 0.4147 0.000
Simple Massless Conductance Heat Cap Density RValue
No Name Construct Construct Btu/h.sLF] [Btu/sLF] lb/cf] h.sf.F/Btu]
1037 Solid Urethane foam core No Yes 0.24 4.2
Layer Material Material Thickness Framing
No. 1t] Factor
1 288 Solid Urethane foam core 0.000
Simple Massless Conductance Heat Cap Density RValue
No Name Construct Construct Btu/h.sLF] [Btu/sLF] lb/cf] h.sLF/Btul
1047 Mtl Bldg Roof/R-38 Batt No No 0.03 1.45 5.85 38.3
Layer Material Material Thickness Framing
No. ft] Factor
1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000
2 23 6 in. Insulation 0.5000 0.000
3 414 R-8 generic Insulatrion 0.1746 0.000
4 12 3 in. Insulation 0.2500 0.000
Simple Massless Conductance Heat Cap Density RValue
No Name Construct Construct Btu/h.sLF] [Btu/sLF] lb/cf] h.sLF/Btu]
1057 1 ft. soil, concrete floor, carpet and No No 0.27 34.00 113.33 3.7
rubber pad
Layer Material Material Thickness Framing
No. ft] Factor
1 265 Soil, 1 ft 1.0000 0.000
2 48 6 in. Heavyweight concrete 0.5000 0.000
3 178 CARPET W/RUBBER PAD 0.000
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
orida Building Code, Sixth Edition (2017) - Energy Conservation ASHRAE 90.1-2013 - Energy Cost Budget Optic
5/1/2020 Page 29 of 29