HomeMy WebLinkAboutAPPRVD FPL FP Prdct SubmlFIRE PROTECTION MATERIAL SUBMITTALS FOR: FFPPLL SSOOLLAARR 3650 AICO ROAD FT. PIERCE, FL 34945 Date: May 18, 2020 Our Project Number: FP-265420 Project Manager: Joe Furlong Prepared By: Thomas Bender The materials submitted represent the quality of materials specified. All materials may be substituted at this contractor’s discretion for like equivalent materials. W. W. Gay Fire & Integrated Systems, Inc. 2251 Rosselle Street / 2500 N.E. 18th Terrace Jacksonville, Florida 32204 / Gainesville, Florida 32609 904-387-7973 / 352-380-0317 TABLE OF CONTENTS 1 PIPE & FITTINGS Schedule 10/40 Sprinkler Pipe – Wheatland ASTM A135, ASTM A795 Ductile Iron Threaded Fittings – AnvilStar Grooved Fittings – Shurjoint Standard Rigid Coupling – Viking VGS 2 VALVES Residential Shut-Off Valve – TYCO Lead Free Double Check Valve Assembly – FEBCO Swing Check Valve - FPPI Residential Riser Manifold – Viking EasyPac with PRV and TestnDrain with 4.2k test orifice 3 SPRINKLER HEADS Sprinkler Heads – Viking 4 HANGERS Purlin Steel Sidewinders - Sammys Loop Hanger Rings – TOLCO All Thread Rod – TOLCO 5 ELECTRICAL DEVICES Flow Switch – Potter Electric Signal Company VSR Flow Switch Alarm Bell – Potter Electric Signal Company PBA1206 6 MISCELLANEOUS Fire Department Connection - FPPI High Quality, High Performance, Long-Lasting Wheatland’s Schedule 10 and Schedule 40 steel fire sprinkler pipe have set the industry’s standards for years. Both products are subjected to the toughest possible testing to assure the highest possible quality and reliable, long-lasting performance. Each is coated with Wheatland’s proprietary mill coating to assure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. The coating also allows the pipe to be easily painted, without special preparation. You can order Schedule 10 or Schedule 40 in black, or with hot- dip galvanizing, to meet FM requirements for dry systems to meet the zinc coating specifications of ASTM A795 or A53. Both Schedule 10 and 40 are UL, C-UL and FM listed and meet NFPA 13 standards. We coat all of our black products up to 6” with our patented MIC Shield™ coating, which helps protect against the onset of microbial corrosion (MIC). Our MIC Shield was the first factory applied coating to be approved by FM as compatible with hybrid sprinkler systems that include CPVC plastic pipe in mixed use occupancies. MIC Shield is also chemically compatible with Flow Guard Gold®, Blaze Master®and Corizan®CPVC. Why Wheatland? • Experience: We’ve manufactured fire sprinkler pipe since 1931 • We produce the most complete line of products in the industry • We offer a number of proprietary products and unique benefits • We provide a complete line of coatings: - in-house, hot dip galvanizing - black sprinkler pipe - MIC shield™, the first FM global approved factory applied, anti-microbial coating for use with CPVC plastic pipe systems - proprietary mill coatings that provide corrosion resistant properties - proprietary mill coatings that extend shelf life Schedule 10 and 40 Meet or Exceed These Standards • UL, C-UL and FM Listed • FM Approved • ASTM A135, , Type E, Grade A (Schedule 10) • ASTM A795, Type E, Grade A (Schedule 40) Green: The steel used to produce Wheatland’s sprinkler pipe contains recycled steel and is virtually totally recyclable. Seismic/Sway Bracing: Wheatland sprinkler pipe data tables are available for determining the forces for piping used as a sway brace component or in Seismic applications. Technical Data Chart Made in U.S.A. 700 South Dock Street, Sharon, PA 16146 Ph: 800.257.8182 • Fax: 724.346.7260 info@wheatland.com • www.wheatland.com Project: Engineer: Locations: Contractor: Specification Reference: Date: System Type: Comments: STEEL FIRE SPRINKLER PIPE Schedule 10 and Schedule 40 SUBMITTAL DATA SHEET Rev. 10/1/11 PRODUCT NPS NOM I.D WT/FT WT/FT H2O FILLED PCS/ LIFT WT/LIFT 21' WT/LIFT 24' WT/LIFT 25' Schedule 10 1 1/4"1.442 1.807 2.514 61 2,315 2,645 2,756 1 1/2" 1.682 2.087 3.049 61 2,673 3,055 3,183 2" 2.157 2.640 4.222 37 2,051 2,344 2,442 2 1/2" 2.635 3.534 5.895 30 2,226 2,544 2,651 3" 3.260 4.336 7.949 19 1,730 1,977 2,060 4" 4.260 5.619 11.789 19 2,242 2,562 2,669 5" 5.295 7.780 17.309 13 2,124 2,427 2,529 6"6.357 9.298 23.038 10 1,953 2,232 2,325 8"8.249 16.960 58.300 7 2,493 2,849 2,968 Schedule 40 1" 1.049 1.681 2.055 70 2,471 2,824 2,942 1 1/4" 1.380 2.275 2.922 51 2,437 2,785 2,901 1 1/2" 1.610 2.720 3.602 44 2,513 2,872 2,992 2" 2.067 3.656 5.109 30 2,303 2,632 2,742 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205 Straight Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A AA FIGURE 3205 - STRAIGHT TEE Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 11⁄4 500 1.75 1.22 32 3450 44.45 0.55 11⁄2 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 3450 57.15 1.11 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205R Reducing Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 x 1 500 1.50 1.36 1.50 0.64 25 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 3⁄4 x 1 500 1.50 1.45 1.50 0.73 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 1 x 1 x 1⁄2 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 x 3⁄4 500 1.37 1.37 1.45 0.76 25 x 25 x 20 3450 34.80 34.80 36.83 0.34 1 x 1 x 11⁄4* 500 1.67 1.67 1.58 0.98 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11⁄2* 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 11⁄4 x 1 x 1⁄2* 500 1.34 1.26 1.53 0.82 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 11⁄4 x 1 x 3⁄4 500 1.45 1.37 1.62 0.90 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 11⁄4 x 1 x 1 500 1.58 1.50 1.67 1.00 32 x 25 x 25 3450 40.13 38.10 42.42 0.45 11⁄4 x 1 x 11⁄4 500 1.75 1.67 1.75 1.08 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 11⁄4 x 1 x 11⁄2 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 11⁄4 x 11⁄4 x 1⁄2 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 34.04 34.04 38.86 0.39 FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11⁄4 x 11⁄4 x 3⁄4 500 1.45 1.45 1.62 0.92 32 x 32 x 20 3450 36.83 36.83 41.15 0.42 11⁄4 x 11⁄4 x 1 500 1.58 1.58 1.67 0.95 32 x 32 x 25 3450 40.13 40.13 42.42 0.43 11⁄4 x 11⁄4 x 11⁄2* 500 1.88 1.88 1.82 1.45 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 C A B 3 1 1 x 2 x 3 2 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3205R Reducing Tee FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 11⁄2 x 11⁄2 x 2*500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 2 x 1 x 2 500 2.25 2.02 2.25 2.15 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 2 x 11⁄4 x 2 500 2.25 2.10 2.25 2.30 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 2 x 11⁄2 x 1⁄2 500 1.49 1.41 1.88 1.50 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 2 x 11⁄2 x 3⁄4 500 1.60 1.52 1.97 1.62 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 2 x 11⁄2 x 1 500 1.73 1.65 2.02 1.64 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 2 x 11⁄2 x 11⁄4 500 1.90 1.82 2.10 1.80 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 2 x 11⁄2 x 11⁄2 500 2.02 1.94 2.16 2.00 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 2 x 11⁄2 x 2 500 2.25 2.16 2.25 2.35 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 2 x 2 x 1⁄2 500 1.49 1.49 1.88 1.60 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 2 x 2 x 3⁄4 500 1.60 1.60 1.97 1.68 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 2 x 2 x 1 500 1.73 1.73 2.02 1.85 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 2 x 2 x 11⁄4 500 1.90 1.90 2.10 2.04 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 2 x 2 x 11⁄2 500 2.02 2.02 2.16 2.18 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 11⁄4 x 11⁄4 x 2*500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 11⁄2 x 1 x 1⁄2 500 1.41 1.34 1.66 0.95 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 11⁄2 x 1 x 3⁄4 500 1.52 1.37 1.75 1.14 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 11⁄2 x 1 x 1 500 1.65 1.50 1.80 1.17 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 11⁄2 x 1 x 11⁄4 500 1.82 1.67 1.88 1.34 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 11⁄2 x 1 x 11⁄2 500 1.94 1.80 1.94 1.45 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 11⁄2 x11⁄4 x 1⁄2 500 1.41 1.34 1.66 1.05 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 11⁄2 x11⁄4 x 3⁄4 500 1.52 1.45 1.75 1.15 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 11⁄2 x 11⁄4 x 1 500 1.65 1.58 1.80 1.25 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 11⁄2 x 11⁄4 x 2*500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 11⁄2 x 11⁄2 x 1⁄2 500 1.41 1.41 1.16 1.15 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 11⁄2 x 11⁄2 x 3⁄4 500 1.52 1.52 1.75 1.24 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 11⁄2 x 11⁄2 x 1 500 1.65 1.65 1.80 1.30 40 x 40 x 25 3450 41.91 41.91 45.72 0.59 11⁄2 x 11⁄2 x 11⁄4 500 1.82 1.82 1.88 1.48 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 C A B 3 1 1 x 2 x 3 2 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221R Reducing Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221R - REDUCING COUPLING Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 x 1⁄2 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3⁄4 500 1.69 0.53 25 x 20 3450 42.92 0.24 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201R Reducing 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3201R - REDUCING 90° ELBOW Nominal Size Max. Working Pressures Dimensions Approx. Wt. Each1 x 2 A B In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3⁄4 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1⁄2 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. A B 2 1 1 x 2 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221 Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221 - COUPLING Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.67 0.40 25 3450 42.42 0.18 11⁄4 500 1.93 0.57 32 3450 49.02 0.26 11⁄2 500 2.15 0.75 40 3450 54.61 0.34 2 500 2.53 1.15 50 3450 64.26 0.52 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3224 Cap For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3224 - CAP Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 11⁄4 500 1.28 0.43 32 3450 32.51 0.20 11⁄2 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 3450 36.83 0.41 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A A FIGURE 3201 - 90° ELBOW Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11⁄4 500 1.75 0.90 32 3450 44.45 0.41 11⁄2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3202 45˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A AFIGURE 3202 - 45° ELBOW Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.12 0.46 25 3450 28.44 0.21 11⁄4 500 1.29 0.73 32 3450 32.76 0.33 11⁄2 500 1.43 0.92 40 3450 36.32 0.42 2 500 1.68 1.50 50 3450 42.67 0.68 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. G-02 Grooved-End Fittings G-02-1/2 Rev.I 20160316 MODEL 901 SHORT RADIUS 90o ELBOW 903 SHORT RADIUS TEE Shurjoint short radius fittings, while primarily designed for fire protection applications, can also be used for general service requirements. The Model K-9 and Z05 rigid couplings can be used with short radius fittings without the worry of bolt pad interference. Shurjoint grooved-end fittings are made of ductile iron per ASTM A536 Gr. 65-45-12 and or ASTM A395 Gr. 65-45-15. C-E dimensions are manufacturer’s standard. Shurjoint standard fitting pressure ratings conform to the ratings of Model 7707 couplings. For Fire Protection pressure rating, listing, and approval information, refer to Data Sheet B-42 or visit SHURJOINT website, www.shurjoint.com for details or contact your SHURJOINT Representative. Models 901 / 903 Nominal Pipe Size Pipe O.D. 901 SR 90o Elbow 903 SR Straight Tee in in C-E Lbs C-E Lbs mm mm in / mm Kgs in / mm Kgs 2 2.375 2.75 1.5 2.75 2.2 50 60.3 70 0.7 70 1.0 2½ 2.875 3.00 2.0 3.00 2.9 65 73.0 76 0.9 76 1.3 76.1 mm 3.000 3.00 2.5 3.00 2.9 76.1 76 1.1 76 1.3 3 3.500 3.38 3.1 3.38 4.4 80 88.9 86 1.4 86 2.0 4 4.500 4.00 4.9 4.00 7.9 100 114.3 102 2.2 102 3.6 139.7 mm 5.500 4.88 7.9 4.88 11.1 139.7 124 3.6 124 5.1 5 5.563 4.88 7.9 4.88 10.1 125 141.3 124 3.6 124 4.6 165.1 mm 6.500 5.50 12.9 5.50 16.5 165.1 140 5.9 140 7.5 6 6.625 5.50 12.9 5.50 17.2 150 168.3 140 5.9 140 7.8 8 8.625 6.94 23.4 6.94 36.3 200 219.1 176 10.6 176 16.5 Full warranty terms can be found on www.shurjoint.com G-02 Grooved-End Fittings G-02-2/2 Rev.I 20160316 MATERIAL SPECIFICATIONS • Fitting body: Ductile Iron to ASTM A536, Gr. 65-45-12 and or ASTM A395, Gr. 65-45-15, min. tensile strength 65,000 psi (448 MPa). • Surface Finish: Orange color painted or red RAL3000 color painted.  (Option) Hot dip galvanized.  (Option) Epoxy coated in red RAL3000 or other colors. General Notes:  Pressure Ratings for fittings conform to the working pressure of the coupling used to join the system.  Listed and or Approved Pressures are pressure ratings for fire protection systems, tested and approved by various approval bodies. Please always refer to the latest approval data posted on the Shurjoint website.  Field Joint Test: For one time only the system may be tested hydrostatically at 1½ times the maximum working pressure listed (AWWA C606 5.2.3).  Warning: Piping systems must always be depressurized and drained before attempting disassembly and or removal of any components.  The 10 Year Limited Warranty applies to manufacturing defects only and does not cover severe service/temperature applications or wear parts.  Shurjoint reserves the right to change specifications, designs and or standard without notice and without incurring any obligations. Shurjoint product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Shurjoint Technical Service. Shurjoint reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligations to make such changes and modifications on Shurjoint products previously subsequently sold. G-03 Z05 G-03-1/3 Rev.M 20160310 MODEL Z05 RIGID COUPLING - Angle-Pad Design - The Shurjoint Model Z05 is an angle-pad design rigid coupling for moderate pressure piping services including fire mains, long straight runs and valve connections. The angle- pad design allows the coupling housings to slide along the bolt pads when tightened. The result is an offset clamping action which provides a rigid joint which resists so called snaking of a long straight run. Support and hanging requirements correspond to ANSI B31.1, B31.9 and NFPA 13. With the removal of only one bolt you can make a fast and easy "swing-over” installation. The Shurjoint Model Z05 is available with a standard “C” shaped or GapSeal gasket in a variety grades to meet your specific service requirements. Z05 couplings should always be installed so that the coupling bolt pads make metal to metal contact. For Fire Protection pressure rating, listing, and approval information, refer to Data Sheet B-42 or visit SHURJOINT website, www.shurjoint.com for details or contact your SHURJOINT Representative. Model Z05 Rigid Coupling Nominal Size Pipe O.D. Max. Working Pressure (CWP)* Max End Load (CWP) Axial Displacement † Dimension Bolt A B C No. Size Weight in in PSI Lbs in in in in in Lbs mm mm Bar kN mm mm mm mm mm Kgs 1¼ 1.660 500 1080 0 ~ 0.05 2.60 4.00 1.81 2 ⅜ x 2⅛ 1.41 32 42.2 35 4.89 0 ~ 1.2 66 102 46 M10 x 55 0.64 1½ 1.900 500 1410 0 ~ 0.05 2.83 4.29 1.81 2 ⅜ x 2⅛ 1.46 40 48.3 35 6.41 0 ~ 1.2 72 109 46 M10 x 55 0.66 2 2.375 500 2210 0 ~ 0.07 3.35 4.61 1.85 2 ⅜ x 2¾ 1.74 50 60.3 35 9.99 0 ~ 1.7 85 117 47 M10 x 70 0.79 2½ 2.875 500 3240 0 ~ 0.07 3.86 5.24 1.85 2 ⅜ x 2¾ M10 x 70 2.05 65 73.0 35 14.64 0 ~ 1.7 98 133 4 0.93 76.1 mm 3.000 500 3530 0 ~ 0.07 3.94 5.35 1.85 2 ⅜ x 2¾ 2.16 76.1 35 15.91 0 ~ 1.7 100 136 47 M10 x 70 0.98 3 3.500 500 4800 0 ~ 0.07 4.45 5.91 1.88 2 ⅜ x 2¾ M10 x 70 2.60 80 88.9 35 21.71 0 ~ 1.7 113 150 48 1.20 108.0 mm 4.250 500 7080 0 ~ 0.16 5.59 6.93 2.13 2 ⅜ x 2¾ 3.62 108.0 35 32.05 0 ~ 4.1 142 176 54 M10 x 70 1.64 4 4.500 500 7940 0 ~ 0.16 5.75 7.20 2.13 2 ⅜ x 2¾ M10 x 70 4.12 100 114.3 35 35.89 0 ~ 4.1 146 183 54 1.87 133.0 mm 5.250 350 7570 0 ~ 0.16 6.69 8.82 2.13 2 ½ x 3 5.14 133.0 24 33.33 0 ~ 4.1 170 224 54 M12 x 75 2.33 139.7 mm 5.500 350 8310 0 ~ 0.16 6.81 8.98 2.09 2 ½ x 3 M12 x 75 5.67 139.7 24 36.77 0 ~ 4.1 173 228 53 2.57 5 5.563 350 8500 0 ~ 0.16 6.89 9.06 2.13 2 ½ x 3 5.69 125 141.3 24 37.62 0 ~ 4.1 175 230 54 M12 x 75 2.58 159.0 mm 6.250 350 10730 0 ~ 0.16 7.80 9.84 2.09 2 ½ x 3 M12 x 75 6.06 159.0 24 47.63 0 ~ 4.1 198 250 53 2.75 Full warranty terms can be found on www.shurjoint.com G-03 Z05 G-03-2/3 Rev.M 20160310 * Working Pressure is based on roll grooved standard wall carbon steel pipe. † Allowable Axial Displacement and Angular Movement (deflection) figures are for roll grooved standard steel pipe. Values for cut grooved pipe will be double that of roll grooved. These values are maximums; for design and installation purposes these figures should be reduced by: 50% for ¾”/DN20 – 3½”/DN90; 25% for 4”/DN100 and larger to compensate for jobsite conditions. Performance Data The following tables show the maximum working pressures (CWP) of Shurjoint Model Z05 Rigid Coupling used on both carbon steel and stainless steel pipes. Shurjoint ductile iron couplings can be used in conjunction with stainless steel pipe in non-corrosive environment as the flow media does not come in direct contact with the coupling housings but rather only the gasket. Model Z05 on Carbon Steel Pipe Model Z05 on Stainless Steel Pipe Nom. Size Cut-Grooved Roll-Grooved Nom. Size Cut-Grooved Roll-Grooved in / mm XS PSI / Bar STD PSI / Bar STD PSI / Bar Sch. 10 PSI / Bar Sch. 7 PSI / Bar in / mm Sch. 80S PSI / Bar Sch. 40S PSI / Bar Sch. 40S PSI / Bar Sch. 10S PSI / Bar Sch. 5S PSI / Bar 1¼ 600 600 500 400 250 1¼ 600 600 450 300 250 32 42 42 35 28 17 32 42 42 31 20 17 1½ 600 600 500 400 250 1½ 600 600 450 300 250 40 42 42 35 28 17 40 42 42 31 20 17 2 600 600 500 400 250 2 600 600 450 300 250 50 42 42 35 28 17 50 42 42 31 20 17 2½ 600 600 500 400 250 2½ 600 600 450 300 250 65 42 42 35 28 17 65 42 42 31 20 17 3 600 600 500 400 250 3 600 600 450 300 250 80 42 42 35 28 17 80 42 42 31 20 17 4 600 600 500 400 200 4 600 600 450 300 200 100 42 42 35 28 14 100 42 42 31 20 14 5 450 450 350 300 175 5 450 450 300 200 NR 125 31 31 24 20 12 125 31 31 20 14 6 450 450 350 300 175 6 450 450 300 125 NR 150 31 31 24 20 12 150 31 31 20 9 8 450 450 350 300 150 8 450 450 300 100 NR 200 31 31 24 20 10 200 31 31 20 7 Model Z05 Rigid Coupling 150 200 Max. (CWP)* PSI Lbs Bar kN 350 11600 24 51.35 350 12050 24 53.36 350 20430 24 90.44 350 19920 24 88.14 Axial in mm 0 ~ 0.16 0 ~ 4.1 0 ~ 0.16 0 ~ 4.1 0 ~ 0.19 0 ~ 4.8 0 ~ 0.19 0 ~ 4.8 Bolt 200 203 264 260 252 254 322 339 53 53 No. Size ½ x 3 ½ x 3 64 ¾ x 4¾ 3.05 6.77 3.07 6.07 7.00 G-03 Z05 G-03-3/3 Rev.M 20160310 MATERIAL SPECIFICATIONS • Housing: Ductile Iron to ASTM A536, Gr. 65-45-12 and or ASTM A395, Gr. 65-45-15, min. tensile strength 65,000 psi (448 MPa). • Surface Finish: Standard painted finishes in orange or RAL3000 red.  Hot dip zinc galvanized (Optional).  Epoxy Coatings in RAL3000 red or other colors (Optional) • Rubber Gasket: Grade “E” EPDM (Color code: Green stripe) Good for cold & hot water up to +230oF (+110oC). Also good for services for water with acid, water with chlorine, deionized water, seawater and waste water, dilute acids, oil-free air and many chemicals. Not recommended for petroleum oils, minerals oils, solvents and aromatic hydrocarbons. Maximum Temperature Range: -30oF (-34oC) to +230oF (+110oC)*. *EPDM gaskets for water services are not recommended for steam services unless couplings or components are accessible for frequent gasket replacement.  (Option) “Lube-E” pre-lubricated EPDM gasket.  (Option) Grade “T” Nitrile (Color code: Orange stripe) Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Also good for water services under +150oF (+66oC). Temperature range: -20 oF to +180 oF (-29 oC to +82 oC). Do not use for HOT WATER above +150 oF (+66 oC) or HOT DRY AIR above +140 oF (+60 oC)  Other options: Grade “O” - Fluoroelastomer. Grade “L” - Silicone. For dry systems we recommend the use of the Shurjoint GapSeal gasket. For additional details contact Shurjoint. • Bolts & Nuts: Heat treated carbon manganese steel track bolts to ASTM A449-83a (or A183 Gr. 2), minimum tensile strength 110,000 psi (758 MPa), Zinc electroplated, with heavy-duty hexagonal nuts to ASTM A563.  (Option) Gr. “E-pw” EPDM (Color code: Double Green Stripes), Good for cold +86oF (+30oC) and hot +180oF (+82oC) potable water services. EPDM is UL classified per NSF/ANSI 61 & NSF/ANSI 372. General Notes:  Maximum Working Pressure (CWP) listed is the maximum cold water pressure for general piping services tested to ASTM F1476 and or AWWA C606 methods. Figures listed are based on roll- or cut-grooved standard wall carbon steel pipe. For other pipe schedules or pipe materials, contact Shurjoint for additional information.  Max. End Load is calculated based on the maximum working pressure (CWP).  Listed and or Approved Pressures are pressure ratings for fire protection systems, tested and approved by various approval bodies. Please always refer to the latest approval data posted on the Shurjoint website.  Field Joint Test: For one time only the system may be tested hydrostatically at 1½ times the maximum working pressure listed (AWWA C606 5.2.3).  Warning: Piping systems must always be depressurized and drained before attempting disassembly and or removal of any components.  The 10 Year Limited Warranty applies to manufacturing defects only and does not cover severe service/temperature applications or wear parts.  Shurjoint reserves the right to change specifications, designs and or standard without notice and without incurring any obligations. Shurjoint product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Shurjoint Technical Service. Shurjoint reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligations to make such changes and modifications on Shurjoint products previously subsequently sold. RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System Page 1 of 6 JULY 2016 TFP980 Worldwide Contacts www.tyco-fi re.com General Description The TYCO RAPID RESPONSE Model RSV-1 Residential Shut-Off Valves are intended for use in dual-purpose resi- dential water supply piping that serves both domestic and residential fi re pro- tection sprinkler system needs. The 1 Inch (DN25) Valve is intended for NFPA 13D system needs, whereas the 2 Inch (DN50) Valve is intended for systems designed in accordance with either NFPA 13, 13D, or 13R. When a fi re sprinkler operates, the Model RSV-1 Residential Shut-Off Valve automatically diverts the avail- able water supply to the fi re sprin- kler system. Consequently, when the Model RSV-1 Valve is utilized, the system designer does not need to add the domestic fl ow demand to the fi re sprinkler system fl ow demand, as would otherwise be required by NFPA 13D or 13R. Consider use of the Model RSV-1 Res- idential Shut-Off Valve when either the water supply cannot adequately provide for both the domestic design demand and the fire sprinkler flow demand, or it is necessary to increase the effectiveness of the fi re sprinkler system by automatically diverting the domestic fl ow. The Model RSV-1 Residential Shut- Off Valve maximizes the effective use of an existing water supply. There- fore, in areas with limited water sup- plies, it may eliminate the need to add costly pumps, pressurized reservoirs, or electrically operated domestic shut- off valves. The Model RSV-1 Valve has a built-in check valve in the fi re sprin- kler system outlet that eliminates the need for a separate check valve. Also, the Model RSV-1 Valve automatically resets, thereby eliminating the need for valve disassembly after a fi re sprinkler system test or operation. NOTICE The Model RSV-1 Residential Shut- Off Valves described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authorities having jurisdiction. Failure to do so may impair the integrity of this device. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Approvals UL and C-UL Listed Certifi ed to all requirements of NSF/ANSI 61, Annex G and NSF/ANSI 372 Notes: The 1 Inch (DN25) Model RSV-1 Resi- dential Shut-Off Valve is suitable for use in water supply arrangements for resi- dential fi re sprinkler systems designed per NFPA 13D. The 2 Inch (DN50) Model RSV-1 Resi- dential Shut-Off Valve is suitable for use in water supply arrangements for resi- dential fi re sprinkler systems designed per NFPA 13, 13D, or 13R. Maximum Pressure 175 psi (12,1 bar) Weight 1 Inch (DN25): 11 lbs. (5 kg) 2 Inch (DN50): 29 lbs. (11 kg) Pressure Loss Refer to Graphs A and B Patents 2 Inch (DN50) Model RSV-1 Valve Patent Pending Physical Characteristics 1 Inch (DN25) Valve Body . . . . . . . . . . . . . . . . . . . . . . . .Copper Alloy Top and Bottom Cover . . . . . . . . . .Copper Alloy Upper Cap . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Bottom Seal . . . . . . . . . . . . . . . . . . . . . . . .Brass Piston . . . . . . . . . . . . . . . . . . . . . . . . . . . Plastic* Differential Ring . . . . . . . . . . . . . . . . . . . Plastic* Sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . . Plastic* Upper and Lower Seals . . . . . . . . . . . . . . EPDM O-Rings . . . . . . . . . . . . . . . . . . . . . . . . . . Buna-N Piston Spring . . . . . . . . . . . . . . . Stainless Steel Piston Screws . . . . . . . . . . . . . . . Stainless Steel Cap Screw . . . . . . . . . . . . . . . . . . Stainless Steel 2 Inch (DN50) Valve Body and Cover . . . . . . . . . . . . . . .Copper Alloy Piston Insert . . . . . . . . . . . . . . . . . .Copper Alloy Bottom Seal . . . . . . . . . . . . . . . . . .Copper Alloy Piston Cover . . . . . . . . . . . . . . . . . . . . . . Plastic* Insert Sleeve . . . . . . . . . . . . . . . . . . . . . . Plastic* Piston Seal . . . . . . . . . . . . . . . . . . . . . . . . EPDM O-Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . EPDM Piston Spring . . . . . . . . . . . . . . . Stainless Steel Piston Nut . . . . . . . . . . . . . . . . . . Stainless Steel Retainer Ring . . . . . . . . . . . . . . . Stainless Steel *Glass Reinforced Polyphenylene Oxide TFP980 Page 2 of 6 Operating Principles When a fi re sprinkler activates during domestic usage, the TYCO RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve automatically diverts fl ow to the domestic system and diverts the available water supply to the fi re sprinkler system, thereby eliminating a reduced fl ow condition in the sprinkler system that might otherwise be caused by possible signifi cant domestic water usage. When the Model RSV-1 Valve is in the normal standby position as shown in Figures 4 and 5, the Piston Assembly, assisted by its Spring, is in the down position. With the Piston Assembly in the down position, the Fire Sprinkler Seal permits the Model RSV-1 Valve to perform as a conventional check valve. Also, with the Piston Assembly in the down position, water is available on demand through the Domestic Flow Passage and out the Domestic Port. Upon operation and with a minimum design water fl ow (e.g., 12.5 GPM (47,3 LPM) for the 1 inch Valve or 8 GPM (30,5 LPM) for the 2 Inch Valve) to the automatic residential fi re sprinkler system, the Piston Assembly moves upward. With the Piston Assembly in the up position, any water fl ow to the Domestic Port is diverted to the Fire Sprinkler Port. The contours of the Piston Assembly are specifi cally confi gured to minimize its upward movement except under the level of sustained fi re sprinkler system fl ow resulting from operation of one or more fi re sprinklers. However, because most fi re sprinkler systems contain air pockets, the Piston Assembly tends to move momentarily upward when there is a surge in supply pressure. The momentary opening and re-clos- ing of the Piston Assembly at the Fire Sprinkler Line Seal traps a portion of the pressure increase within the fi re sprinkler system. Trapped pres- sure increases within the fi re sprinkler system help to prevent a subsequent surge in the supply pressure from causing the water-flow detector to signal a false alarm. As indicated above, domestic system usage can reduce the pressure avail- able to the fire sprinkler system. However, when utilizing the Model RSV-1 Valve, you do not need to include additional hydraulic fl ow of the domes- tic system, when otherwise required by NFPA standards (NFPA 13D or 13R), to determine the minimum possible resid- Design Criteria The TYCO RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve must be installed vertically with the Water Supply Port at the bottom, the Fire Sprinkler Port at the top, and the Domestic Port at the side (Ref. Figures 4 and 5). Figure 1 shows the typical installation arrangement. Refer to the Installation section for additional design considerations. Water Supply Requirements 1 Inch (DN25) Valve In order for the 1 Inch (DN25) Model RSV-1 Valve to operate automati- cally upon sprinkler operation, the fi re sprinkler system from the water main to the most hydraulically remote sprin- kler must be designed to provide a minimum single sprinkler fl ow of 12.5 GPM (47,3 LPM) when the supply pressure at the main is at its minimum expected value. The minimum single sprinkler flow rate of 12.5 GPM (47,3 LPM), required for use with the 1 Inch (DN25) Model RSV-1 Valve, does not take precedence over any more hydraulically demanding single sprinkler fl ow rate specifi ed for the residential sprinklers in use. When performing hydraulic design cal- culations for the fi re sprinkler system, you need not account for the trickle fl ow through the 1 Inch (DN25) Model RSV-1 Valve By-Pass Restriction into the domestic system. For the 1 Inch (DN25) Model RSV-1 Valve, the maximum water supply service line is 1 inch (DN25). 2 Inch (DN50) Valve In order for the 2 Inch (DN50) Model RSV-1 Valve to operate automatically at sprinkler activation, the fi re sprin- kler system from the water supply main to the most hydraulically remote sprinkler must be designed to provide a minimum single sprinkler fl ow of 8 GPM (30,5 LPM) when the water supply pressure at the water supply main is at its minimum expected value. The minimum single sprinkler fl ow rate of 8 GPM (30,5 LPM), required for use with the 2 Inch (DN50) Model RSV-1 Valve, does not take precedence over any more hydraulically demanding single sprinkler fl ow rate specifi ed for the residential sprinklers in use. FIRE SPRINKLER SYSTEM PRESSURE GAUGE WATERFLOW DETECTOR (FIRE ALARM) MODEL RSV-1 RESIDENTIAL SHUT-OFF VALVE (AUTOMATIC) WATER METER MAIN CONTROL VALVE WATER SUPPLY WATER SUPPLY GATE VALVE BACKFLOW PREVENTER AS REQUIRED BY AUTHORITY HAVING JURISDICTION AUTOMATIC FIRE SPRINKLERS TO DOMESTIC SYSTEM SUPPLY PRESSURE GAUGE DOMESTIC CONTROL VALVE DRAIN AND FLOW TEST CONNECTION ALARM TEST CONNECTION WATER SUPPLY MAIN FIGURE 1 MODEL RSV-1 RESIDENTIAL SHUT-OFF VALVE TYPICAL INSTALLATION ARRANGEMENT TFP980 Page 3 of 6 ual (fl owing) pressure available to the fi re sprinkler system. For operation of the Model RSV-1 Resi- dential Shut-Off Valve, you need only design the fi re sprinkler system from the water supply main to the most hydraulically remote sprinkler. Domes- tic fl ow does not require consideration. As long as the single sprinkler fl ow is equal to or greater than 12.5 GPM (47,3 LPM) for the 1 Inch Valve or 8 GPM (30,5 LPM) for the 2 Inch Valve when the supply pressure at the main is at its minimum expected value, the Model RSV-1 Valve automatically diverts the domestic fl ow. After the Piston Assembly has moved to the full up position, only a small amount of water is permitted to trickle through the Internal By-Pass Restric- tion to the Domestic Port (Ref. Figures 4 and 5). The trickle fl ow through the Internal By-Pass Restriction permits the Model RSV-1 Valve to reset auto- matically after a sprinkler operation or test without draining the fi re sprinkler system. When the Domestic Control Valve is closed, the Internal By-Pass Restriction allows the Supply and Domestic Port pressures to equalize and the Piston Assembly to move back down to the standby position. When using the 1 inch RSV-1, the maximum fl ow rate through the Internal By-Pass Restriction, when the Model RSV-1 Valve is in the operated position, is no greater than .25 GPM (0,9 LPM) for a typical residual (fl owing) pressure of 40 psi (2,8 bar) at the inlet. Conse- quently, when performing hydraulic design calculations for the fi re sprinkler system, you do not need to consider trickle fl ow through the Model RSV-1 Valve Internal By-Pass Restriction into the domestic system. When using the 2 inch RSV-1, the maximum fl ow rate through the Internal By-Pass Restriction, when the Model RSV-1 Valve is in the operated position, is no greater than 1.5 GPM (5,7 LPM) for a typical residual (fl owing) pressure of 40 psi (2,8 bar) at the inlet. Conse- quently, when performing hydraulic design calculations for the fi re sprin- kler system, a 1.5 GPM (5,7 LPM) fl ow demand is required to be added at the RSV-1 and calculated back to the source. Components: -2 Body1- 4 9 12 13 1 7 8 6 3 2 5 8-3/16" (208,0 mm) 4-15/16" (125,4 mm) 3-1/4" (82,6 mm) 2-3/8" (60,3 mm) WATER SUPPLY PORT, 1" NPT 3-5/8" DIA. (92,1 mm) FIRE SPRINKLER PORT, 1" NPT DOMESTIC PORT, 1" NPT 11 14 15 10 5 Top Cover Screw, Upper Cap 3 - Upper Cap-4 O-Ring, Cover (2) 5 - Upper Seal6- O-Ring, Upper Sleeve 7 - Sleeve8- Spring9- Differential Ring 10 - Lower Seal11- Screw, Piston (4) 12 - Bottom Cover13- Piston-14 O-Ring, Lower Sleeve 15 - Components: 4-1/2" (114,3 mm) 4-9/16" (115,9 mm) 5-3/8" DIA. (136,5 mm) 3-3/4" (95,3 mm) 9-1/16" (230,2 mm) FIRE SPRINKLER PORT, 2" NPT DOMESTIC PORT, 2" NPT WATER SUPPLY PORT, 2" NPT -2 Insert Sleeve Cover O-Ring Insert Sleeve O-Ring (2) Piston Seal Bottom Seal -8 -4 7 - 3 - Body1- Piston Nut Piston Spring -6 5 - Piston Cover Piston Insert Cover Retainer Ring 9 - 10 - 11 - 12 - -13 Bottom Seal O-Ring 3 7 9 4 2 9 11 10 6 5 1 12 8 13 FIGURE 2 1 INCH (DN25) MODEL RSV-1 RESIDENTIAL SHUT-OFF VALVE ASSEMBLY AND DIMENSIONS FIGURE 3 2 INCH (DN50) MODEL RSV-1 RESIDENTIAL SHUT-OFF VALVE ASSEMBLY AND DIMENSIONS TFP980 Page 4 of 6 Installation Figure 1 illustrates a typical installation arrangement using the TYCO RAPID RESPONSE Model RSV-1 Residen- tial Shut-Off Valve. The arrangement may need to be modifi ed to meet the requirements of the authority having jurisdiction. However, the Model RSV-1 Valve must be installed in accordance with this section. General Instructions A fi re sprinkler water supply connec- tion to a public water supply is usually subject to local regulations concern- ing metering and backfl ow prevention requirements. Consult with the local water authorities concerning local requirements that may apply to the arrangement of these components in the fi re sprinkler system water supply. For the 1 Inch (DN25) Valve, the maximum water supply service line is 1 Inch (DN25). Step 1. Ensure that the water supply to the Model RSV-1 Valve is free of contaminants and particles of a size greater than 1/8 inch (3,2 mm). Step 2. Install the Model RSV-1 Valve vertically with the Supply Port at the bottom, the Fire Sprinkler Port at the top, and the Domestic Port at the side. Ensure that the arrows cast on the Body point in the direction of fl ow. A suitable clamp along the water supply riser piping is recommended to provide support for the weight of the Model RSV-1 Valve. Step 3. Place a Domestic Control Valve between the Model RSV-1 Valve and the domestic system. Position the inlet to the Domestic Control Valve within 12 inches of the Domestic Port of the Model RSV-1 Valve. Step 4. The Drain and Flow Test Con- nection (Ref. Figure 1) is recommended to be a minimum 1/2 inch (DN15) size for systems per NFPA 13D, and it must be a minimum 1 inch (DN25) size for systems per NFPA 13R. Step 5. Install an Alarm Test Connec- tion with a test orifi ce equal to or less than the smallest K-factor sprinkler in the system downstream of the Water- fl ow Detector. Step 6. Apply pipe-thread sealant spar- ingly only to the male pipe threads that are to be assembled to the three ports of the Model RSV-1 Valve. The use of a non-hardening pipe-thread sealant such as TEFLON is recommended. Valve Setting Procedure Perform steps 1 through 9 when initially fi lling the fi re sprinkler and domestic system piping with water or after a fi re sprinkler operation (Ref. Figure 1). Step 1. Close the Main Control Valve. Step 2. Close the Domestic Control Valve and all water outlets in the domestic piping system. Step 3. In addition to the Drain and Flow Test Connection in the fi re sprin- kler system, close all drain valves and replace all operated sprinklers as necessary. Step 4. Partially open the Main Control Valve until the sound of fl owing water just begins, then leave the Main Control Valve in the partially open position. FLOW RATE IN GALLONS PER MINUTE (GPM) 2.0 0.4 0.1 0.2 0.3 0.6 0.5 0.8 1.0 3.0 4.0 6.0 5.0 56 10820304050NOMINAL PRESSURE DROPIN POUNDS PER SQUARE INCH (PSI)0,04 0,03 0,02 0,01 0,30 0,20 0,08 0,10 0,06 0,05 0,40 NOMINAL PRESSURE DROP IN BAR(1 PSI = 0,06895 BAR)20 4030 60 8050 100 FLOW RATE IN LITERS PER MINUTE (LPM) (1 GPM = 3,785 LPM)DOMESTIC PORTFIRE SPRINKLER PORT200 FLOW RATE IN GALLONS PER MINUTE (GPM) 0.6 0.9 1.0 0.7 0.8 3.0 4.0 5.0 2.0 6050 80 100 200 10.0 9.0 8.0 7.0 6.0 0,09 0,08 0,10 0,07 0,05 0,06 0,20 0,30 0,60 0,40 0,50 200 500400300 700 900 DOMESTIC PORTFIRE SPRINKLER PORTFLOW RATE IN LITERS PER MINUTE (LPM) (1 GPM = 3,785 LPM)NOMINAL PRESSURE DROPIN POUNDS PER SQUARE INCH (PSI)NOMINAL PRESSURE DROP IN BAR(1 PSI = 0,06895 BAR)GRAPH A 1 INCH (DN25) MODEL RSV-1 VALVE RESIDENTIAL SHUT-OFF VALVE NOMINAL PRESSURE LOSS VS. FLOW GRAPH B 2 INCH (DN50) MODEL RSV-1 VALVE RESIDENTIAL SHUT-OFF VALVE NOMINAL PRESSURE LOSS VERSUS FLOW TFP980 Page 5 of 6 SUPPLYSUPPLY TO DOMESTIC TO FIRE SPRINKLERS OPERATEDSTANDBY FIRE SPRINKLER FLOW PASSAGE SUPPLY PORT FIRE SPRINKLER PORT DOMESTIC PORT FIRE SPRINKLER SEAT SUPPLY PORT FIRE SPRINKLER SEAT DOMESTIC PORT FIRE SPRINKLER PORT PISTON ASSEMBLY DOMESTIC SEAT INTERNAL BY-PASS RESTRICTION PISTON ASSEMBLY DOMESTIC FLOW PASSAGE DOMESTIC SEAT OPERATEDSTANDBY SUPPLYSUPPLY TO FIRE SPRINKLERS TO DOMESTIC FIRE SPRINKLER FLOW PASSAGE SUPPLY PORT FIRE SPRINKLER PORT DOMESTIC PORT FIRE SPRINKLER SEAT SUPPLY PORT FIRE SPRINKLER SEAT DOMESTIC PORT FIRE SPRINKLER PORTPISTON ASSEMBLY DOMESTIC SEAT INTERNAL BY-PASS RESTRICTION PISTON ASSEMBLY DOMESTIC FLOW PASSAGE DOMESTIC SEAT FIGURE 4 1 INCH (DN25) MODEL RSV-1 RESIDENTIAL SHUT-OFF VALVE STANDBY AND OPERATED CONDITIONS FIGURE 5 2 INCH (DN50) MODEL RSV-1 VALVE RESIDENTIAL SHUT-OFF VALVE STANDBY AND OPERATED CONDITIONS GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP980 Page 6 of 6 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation Step 5. After the fi re sprinkler system pressure gauge indicates approxi- mately the same pressure as the supply pressure gauge, fully open the Main Control Valve. Step 6. Open the highest elevation outlet on the domestic system. Step 7. Partially open the Domestic Control Valve until the sound of fl owing water begins. Allow the domestic piping to fi ll slowly with water. Step 8. Close the highest elevation water outlet on the domestic system when unaerated water begins to fl ow. Step 9. Completely open the Domes- tic Control Valve, then check that the domestic system is properly pressur- ized by verifying that at least three water outlets in the domestic system can fl ow full at the same time. • If the water outlets fl ow fully, the Model RSV-1 Valve is set and ready for service. Close the water outlets on the domestic system. • If the water outlets do not fl ow fully, re-close the Domestic Control Valve, wait a minimum of ten seconds, and ensure that there is no fl ow from the fi re sprinkler system piping. Reopen the Domestic Control Valve, then recheck that the water outlets are fl o w i n g f u l l y . Care and Maintenance The following inspection procedure for the TYCO RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve must be performed as indicated, in addition to any specifi c requirements of the NFPA. Any impairment must be imme- diately corrected. Before closing a fi re protection system control valve for inspection or main- tenance work on the fi re protection system that it controls, obtain per- mission to shut down the affected fi re protection system from the proper authorities and notify all personnel who may be affected by this action. Make no attempt to repair any Model RSV-1 Valve component in the fi eld. The Model RSV-1 Valve is not fi eld- repairable. If malfunction occurs, the entire unit must be replaced. The operational test and fl ow test pro- cedures result in operation of the asso- ciated alarms, as well as an interruption of the domestic water supply service. You must notify the owner, building occupants, and the fi re department, central station, or other signal station to which the alarms are connected. After placing a fi re protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspection, testing, and maintenance of their fi re protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualifi ed Inspection Service in accor- dance with local requirements and/or national codes and standards. Operation Test Procedure Step 1. Fully open two or three water outlets in the domestic piping system. Step 2. To simulate a sprinkler opera- tion, open the Alarm Test Connection of the fi re sprinkler system. Step 3. Verify that any alarms are oper- ating and that the fl ow from the domes- tic water outlets decreases to no more than a trickle. Step 4. Reset the Model RSV-1 Valve in accordance with the Valve Setting Procedure described in this data sheet. Flow Test Procedure Step A. While there is no water fl owing in the domestic system, com- pletely open the Drain and Flow Test Connection. Step B. While water is fl owing, record the pressure reading on the fi re sprin- kler system pressure gauge and then compare this reading to previous readings. If there is a signifi cant decrease in pres- sure since the last time the pressure reading was taken and this decrease is not due to a normally expected drop in the water supply pressure, an impair- ment may exist that should be immedi- ately identifi ed and corrected. Step C. Close the Drain and Flow Test Connection to allow the Model RSV-1 Valve to reset automatically. Automatic resetting occurs within ten seconds. Step D. After waiting ten seconds, com- pletely open at least three water outlets in the domestic system and allow these outlets to fl ow simultaneously. If the water outlets flow fully, the Model RSV-1 Valve is set and ready for service. Close the water outlets on the domestic system. If the water outlets do not fl ow fully, close the Domestic Control Valve and verify that there is no fl ow from the fi re sprinkler system piping, such as at the Inspector’s Test Connection. Wait a minimum of ten seconds. Re-open the Domestic Control Valve and then recheck that the domestic system water outlets are fl owing full. Limited Warranty For warranty terms and conditions, visit www.tyco-fi re.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Valves with NPT Connections Specify: 1 Inch NPT (DN25) Model RSV-1 Residential Shut-Off Valve, P/N 52-540-1-001 Specify: 2 Inch NPT (DN50) Model RSV-1 Residential Shut-Off Valve, P/N 52-540-1-002 Series LF850 1⁄2" - 2" (15-50mm) Outdoor Installation Flow12" Min. (300mm) 12" (300mm) Minimum Clearance to Fixed Structure FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact FEBCO. FEBCO reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Engineer –––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––– The FEBCO Series LF850 Double Check Valve Assemblies are designed for non-health hazard applications. The LF850S features Lead Free* construction to comply with Lead Free* installation requirements. End Connections – NPT ANSI / ASME B1.20.1. The Lead Free* Double Check Valve Assemblies shall comply with state codes and standards, where applicable, requiring reduced lead content. Pressure – Temperature Max. Working Pressure: 175psi (12.1 bar) Hydrostatic Test Pressure: 350psi (24.1 bar) Temperature Range: 32°F to 140°F (0°C to 60°C) Materials Valve Body: Lead Free* cast copper silicon alloy Elastomers: Silicone Springs: Stainless Steel Models • LF850 - Standard Assembly with Ball Valves • LF850U - Standard Assembly with Union Ball Valves Approvals – Standards • ANSI/AWWA Conformance (C510-92) • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Typical Installation Series LF850 kPa psi 138 20 103 15 69 10 34 5 0 0 2" (50mm) 0 30 60 90 120 150 180 gpm 0 114 227 341 454 570 681 lpmHeadLOSS (PSI) kPa psi 138 20 103 15 69 10 34 5 0 0 11⁄2" (40mm) 0 20 40 60 80 100 120 gpm 0 76 152 227 303 379 454 lpmHeadLOSS (PSI) kPa psi 138 20 103 15 69 10 34 5 0 0 11⁄4" (32mm) 0 20 40 60 80 100 120 gpm 0 76 152 227 303 379 454 lpmHeadLOSS (PSI) kPa psi 138 20 103 15 69 10 34 5 0 0 1" (25mm) 0 10 20 30 40 50 60 gpm 0 38 76 114 152 190 227 lpmHeadLOSS (PSI) kPa psi 138 20 103 15 69 10 34 5 0 0 3⁄4" (20mm) 0 5 10 15 20 25 30 gpm 0 19 38 57 76 95 114 lpmHeadLOSS (PSI) kPa psi 138 20 103 15 69 10 34 5 0 0 1⁄2" (15mm) 0 3 6 9 12 15 18 gpm 0 11 23 34 45 57 68 lpmHeadLOSS (PSI)Capacity 1015 B64.5 ES-F-LF850S SPECIFICATION SHEET Series LF850 Lead Free* Double Check Valve Assemblies Size: 1⁄2" - 2" (15mm - 50mm)** LEAD FREE* Series LF850 / Size: 1⁄2" - 2" (15mm - 50mm) ITEM DESCRIPTION MATERIALS 1 Body Lead Free* cast copper silicon alloy 1.2 Tailpiece Lead Free* cast copper silicon alloy 1.4 O-Ring Silicone 2 Cover Lead Free* cast copper silicon alloy 2.2 O-Ring Silicone 3 Seat Noryl® 3.1 O-Ring Silicone 4 Poppet Noryl® 5 Seat Disc Silcone 5.1 Disc Retainer Noryl® 5.2 Rnd HD Screw Stainless Steel 6 Spring Stainless Steel 7 Guide Noryl® 8 Retainer Spacer Noryl® 9 Ball Valve (w/tap) Lead Free* cast copper silicon alloy 9.1 Ball Valve Lead Free* cast copper silicon alloy 11 Test Cock Lead Free* cast copper silicon alloy 21 Hex HD Capscrew Stainless Steel 60 Identification Plate Brass 61 Drive Screw Stick Stainless Steel Check Assembly SIze (dN)dIMeNSIONS weIgHt A B C D E in.mm in.mm in.mm in.mm in.mm in.mm lbs.kgs. 1⁄2 15 10 254 11⁄2 38 11⁄2 38 31⁄8 79 11⁄4 32 4.2 1.9 3⁄4 20 103⁄4 273 11⁄2 38 11⁄2 38 31⁄8 79 11⁄4 32 4.4 2.0 1 25 121⁄2 318 17⁄8 48 15⁄8 41 33⁄8 86 11⁄2 38 6.8 3.1 11⁄4 32 157⁄8 403 3 76 21⁄2 64 41⁄4 108 21⁄4 57 15.8 7.2 11⁄2 40 163⁄8 416 3 76 21⁄2 64 41⁄4 108 21⁄4 57 16.2 7.4 2 50 175⁄8 450 31⁄2 89 21⁄2 64 41⁄4 108 21⁄4 57 21.1 9.6 Dimensions and Weights Size: 1⁄2" - 2" (15 - 50mm) Note: Dimensions are nominal. Allowances must be made for normal manufacturing tolerances. ES-F-LF850S 1330 © 2013 FEBCO A Watts Water Technologies Company d e a C B Noryl® is a registered trademark of SABIC Innovative Plastics™. *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. USA: Tel: (559) 441-5300 • Fax: (559) 441-5301 • www.FEBCOonline.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.FEBCOonline.ca **Metric Dimensions are nominal pipe diameter. This product is produced with NPT threaded end connections. Warning DO NOT OVER TIGHTEN. Over tightening during installation will crack the valve body. Evidence of overtightening may not be readily visible or apparent upon pressurization. Installation For horizontal installation only. The female by female swing check valve should be installed in accordance with commonly used installation practices for the fire sprinkler industry. Proper seal of the threads can be accomplished by applying a liberal amount of PTFE based thread seal- ant such as PipeFit® Thread Sealant Paste or PTFE Tape. Never use tape and paste together. This will cause excessive stress on the threaded connection leading to failure of the valve. Do not exceed one full turn past hand tight when installing male threads into the check valve. Specifications Valve Body: Cast Bronze* (85-5-5-5) Clapper Assembly: Forged Brass Seat: NBR (Chloramine Resistant) Sizes: 1/2” IPS 2” IPS Female by female Rated Pressure: 250 psi *Contains lead. Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Description The bronze* swing check valve features a full floating clapper assembly that provides for a positive seal each time the valve is cycled. This feature improves the swing check valves ability to “clear” any debris that may be present in the water supply. The seat material is NBR which provides for a positive seal even under light residual pressures. WWW.FPPI.COM Swing Check Valve Full Floating Clapper Assembly TECHNICAL DATA Page 1 of 5 EASYPAC RESIDENTIAL RISER MANIFOLD ASSEMBLIES 1” - 2” (DN25 - DN50) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_102407 18.10.18 Rev P65 1. DESCRIPTION Viking EasyPac Residential Riser Manifold Assemblies are available in sizes 1”, 1-1/4”, 1-1/2”, and 2” for NFPA 13D and NFPA13R residential fire sprinkler systems. The configuration eliminates the need to drain the system before installing the relief valve, while a built in test port allows hydrostatic testing without draining the system. The EasyPac Residential Assemblies include pressure gauges, Potter flow switches, 3-way gauge control valve and 1” drain valve (or 1-1/4” for 2” Manifold). The EasyPac assemblies are made with steel bodies and are available in threaded or grooved connections. 2. LISTINGS AND APPROVALS Pressure Gauges: UL Listed, FM Approved Waterflow Alarm Switch: UL Listed - Category USQT, cUL Listed, FM Approved - Waterflow Detectors, Vane Type, CSFM Listed Ball Valve: UL Listed, FM Approved AGF TestanDrain Model 1000: UL Listed - Category VEHZ, FM Approved - Sprinkler System Alarm Testers AGF TestanDrain Model 1011 with Pressure Relief Valve: UL Listed - Category VEHZ, FM Approved - Sprinkler System Alarm Testers 3. TECHNICAL DATA Specifications and Material Standards: Available since 2007. • Pressure Rating: 250 PSI (17.2 bar) maximum water working pressure. • Fabricated steel pipe. • Available in male NPT threaded inlet and outlet connections using Schedule 40 steel pipe. • Available in grooved inlet and outlet connections using Schedule 10 steel pipe. • Available with male NPT threaded inlet x grooved outlet using Schedule 40 steel pipe. • Riser bodies coated with black Ecoat. • Flow Switch: Two single-pole double-throw switches with Form C contacts rated at 15 Amps 125/250 V. AC, 2.5 Amp 0-30 V. DC. Each switch can be wired for open or closed circuit operation. See Figure 1. Ordering Information: (Also refer to the current Viking price list.) There are three different options available for the Residential line: Basic Residential EasyPac Assemblies with Ball Valve Drain (See Figure 2) Residential EasyPac Assemblies with TESTanDRAIN Valve (See Figure 3) Residential EasyPac Assemblies with TESTanDRAIN and Pressure Relief Valve (PRV) (See Figure 4) See Table 1 for Part Numbers. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Note: The EasyPac Residential Riser Manifold Assembly can be installed horizontally with flow switch on top, or vertically with flow upward. Viking EasyPac Riser Assemblies use Potter VSR flow switches. The literature that accompanies the VSR states that the switch should not be installed within 6” of a change of direction of pipe or within 24” of a valve. This is merely a recommendation to reduce the pos- sibility of the switch not operating while minimal waterflow is occurring. This is a recommendation only, not a requirement. 5. TESTANDRAIN VALVE OPERATING INSTRUCTIONS 1. To Test: Turn valve handle counterclockwise from “Off” to “Test”. The handle will stop automatically. After test is completed, return handle to “Off”. 2. To Drain: Turn handle counterclockwise from “Off” to “Test”. The handle will stop automatically. Depress “Push” button and turn handle to “Drain”. When system is empty, return handle clockwise to “Off” position. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking EasyPac Riser Assemblies are available through a network of domestic and international distributors. See The Viking Cor- poration web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Replaces Form No. F_102407 Rev September 18, 2009 (Added P65 Warning.) TECHNICAL DATA Page 2 of 5 EASYPAC RESIDENTIAL RISER MANIFOLD ASSEMBLIES 1” - 2” (DN25 - DN50) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_102407 18.10.18 Rev P65 Table 1 - Commercial EasyPac Assemblies Pipe Size Inlet / Outlet Connections Option Pipe Size Viking Part Number 1” Thread / Thread Ball Valve Schedule 40 15226 TESTanDRAIN 15227 TESTanDRAIN and PRV 15228 Groove / Groove Ball Valve Schedule 10 15243 TESTanDRAIN 15244 TESTanDRAIN and PRV 15245 1-1/4” Thread / Thread Ball Valve Schedule 40 14840 TESTanDRAIN 15229 TESTanDRAIN and PRV 15230 Groove / Groove Ball Valve Schedule 10 14841 TESTanDRAIN 15231 TESTanDRAIN and PRV 15232 Thread / Groove Ball Valve Schedule 40 14905 TESTanDRAIN 15233 TESTanDRAIN and PRV 15234 1-1/2” Thread / Thread Ball Valve Schedule 40 14842 TESTanDRAIN 15235 TESTanDRAIN and PRV 15236 Groove / Groove Ball Valve Schedule 10 14843 TESTanDRAIN 15237 TESTanDRAIN and PRV 15238 Thread / Groove Ball Valve Schedule 40 14849 TESTanDRAIN 15239 TESTanDRAIN and PRV 15240 2” Thread / Thread Ball Valve Schedule 40 14844 TESTanDRAIN 15241 TESTanDRAIN and PRV 14901 Groove / Groove Ball Valve Schedule 10 14845 TESTanDRAIN 15242 TESTanDRAIN and PRV 14900 Thread / Groove Ball Valve Schedule 40 14846 TESTanDRAIN 15246 TESTanDRAIN and PRV 15247 TESTanDRAIN Option: Includes a test orifice with size specified from 3/8” (K2.8) to 25K ESFR*, depending on the smallest sprinkler installed on the system. Must add suffix to the part number for the desired orifice size. Orifice Suffix: A = 3/8” (K 2.8) B = 7/16” (K 4.2) C = 1/2” (K 5.6) D = 17/32” (K 8.0) TESTanDRAIN with PRV Option: Includes test orifice and pressure relief valve. The test orifice must be specified based on the smallest sprinkler installed on the system for 3/8” (K2.8) to K25 ESFR*. The pressure relief valve is not factory assembled to the TestanDrain. Must add suffix to the part number for the desired orifice size and pressure setting of the pressure relief valve. Orifice Suffix: A = 3/8” (K 2.8) B = 7/16” (K 4.2) C = 1/2” (K 5.6) D = 17/32” (K 8.0) PRV Suffix: 175 185 195 205 225 250 NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. Table 2 - Pipe Diameters 1”1-1/4”1-1/2”2” Pipe OD 1.315” (33.4 mm)1.660” (42 mm)1.900” (48 mm)2.375” (60 mm) Schedule 10 Pipe ID 1.097” (27.9 mm)1.45” (36.6 mm)1.69” (42.7 mm)2.16” (54.8 mm) Schedule 40 Pipe ID 1.049” (26.6 mm)1.38” (35.1 mm)1.61” (40.9 mm)2.07” (52.5 mm) Figure 1 - Flow Switch with Two Single Pole, Double Throw Micro Switches TECHNICAL DATA Page 3 of 5 EASYPAC RESIDENTIAL RISER MANIFOLD ASSEMBLIES 1” - 2” (DN25 - DN50) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_102407 18.10.18 Rev P65 Figure 2 - Basic Residential EasyPac Size A B C D E F G H I 1” (DN25)1 VSR-S Flow Switch3 1” Hose 16-3/32” (409) 14-15/16” (379) 1” (25) 6-3/16” (157) 5-3/4” (146) 3-1/2” (89) 8” (203) 1-1/4” (DN32)VSR-S Flow Switch3 1” NPT 16-1/2” (419) 15” (381) 1-1/2” (38) 6-3/32” (155) 6-11/32” (161) 4-3/16” (107) 8-9/16” (218) 1-1/2” (DN40)VSR-S Flow Switch3 1” NPT 16-1/2” (419) 15” (381) 1-1/2” (38) 6-7/32” (158) 6-15/16” (164) 4-5/16” (110) 9-11/16” (246) 2” (DN50)VSR Flow Switch4 1-1/4” NPT 14-1/2” (369) 13” (330) -1/2” (-12)2 6-7/16” (164) 5-51/64” (148) 5” (127) 9-23/64” (238) 1 The body of the 1” manifold is comprised of four 1” nipples and three tee’s. 2 Dimension E is negative because the ball valve extends below the end of the manifold body. 3 Mounted with included nipple (As shown above) 4 Mounted with included U bolt (Not Shown) Note: Dimensions may vary by ± 1/4” (6.3 mm) 1” (DN25)1 1-1/4” - 2” (DN32 - DN50) TECHNICAL DATA Page 4 of 5 EASYPAC RESIDENTIAL RISER MANIFOLD ASSEMBLIES 1” - 2” (DN25 - DN50) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_102407 18.10.18 Rev P65 Figure 3 - Residential EasyPac with TESTanDRAIN Size A B C D E F G H I 1” (DN25)1 VSR-S Flow Switch2 1” Hose 16-1/16” (409) 14-15/16” (379) 2-11/16” (68) 6-3/16” (157) 5-3/4” (146) 3-7/8” (98) 8-1/2” (216) 1-1/4” (DN32)VSR-S Flow Switch2 1” NPT 16-1/2” (419) 15” (381) 5-1/8” (131) 6-3/32” (155) 6-11/32” (161) 4-15/32” (114) 9-3/32” (231) 1-1/2” (DN40)VSR-S Flow Switch2 1” NPT 16-1/2” (419) 15” (381) 5-1/8” (131) 7-19/32” (193) 6-15/16” (164) 4-19/32” (117) 9-7/32” (234) 2” (DN50)VSR Flow Switch3 1-1/4” NPT 14-1/2” (369) 13” (330) 3-1/4” (83) 6-7/16” (164) 5-51/64” (148”) 5-13/64” (132) 10-45/64” (272) 1 The body of the 1” manifold is comprised of four 1” nipples and three tee’s. 2 Mounted with included nipple (As shown above) 3 Mounted with included U bolt (Not Shown) Note: Dimensions may vary by ± 1/4” (6.3 mm) 1” (DN25)1 1-1/4” - 2” (DN32 - DN50) TECHNICAL DATA Page 5 of 5 EASYPAC RESIDENTIAL RISER MANIFOLD ASSEMBLIES 1” - 2” (DN25 - DN50) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_102407 18.10.18 Rev P65 Figure 4 - Residential EasyPac with TESTanDRAIN and PRV Size A B C D E F G H I 1” (DN25)1 VSR-S Flow Switch2 1” NPT 16-1/16” (409) 14-15/16” (379) 2-11/16” (68) 6-3/16” (157) 5-3/4” (146) 3-7/8” (98) 8-1/2” (216) 1-1/4” (DN32)VSR-S Flow Switch2 1” NPT 16-1/2” (419) 15” (381) 5-1/8” (131) 6-3/32” (155) 6-11/32” (161) 4-15/32” (114) 9-3/32” (231) 1-1/2” (DN40)VSR-S Flow Switch2 1” NPT 16-1/2” (419) 15” (381) 5-1/8” (131) 7-19/32” (193) 6-15/16” (164) 4-19/32” (117) 9-7/32” (234) 2” (DN50)VSR Flow Switch3 1-1/4” NPT 14-1/2” (369) 13” (330) 3-1/4” (83) 6-7/16” (164) 5-51/64” (148”) 5-13/64” (132) 10-45/64” (272) 1 The body of the 1” manifold is comprised of four 1” nipples and three tee’s. 2 Mounted with included nipple (Not Shown) 3 Mounted with included U bolt (As shown above) Note: Dimensions may vary by ± 1/4” (6.3 mm) 1” (DN25)1 1-1/4” - 2” (DN32 - DN50) Replaces Form No. F_102407 Rev September 18, 2009 (Added P65 Warning.) FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA Page 1 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Form No. F_012706 19.02.21 Rev 19.1 1. DESCRIPTION Viking Freedom® Residential Pendent Sprinkler VK468 is a small, thermosensitive, glass- bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corro- sion resistant as indicated in the Approval Chart. The orifice design, with a K-Factor of 4.9 (70.6 metric†), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteris- tics meet the challenges of residential sprinkler standards. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW VdS Approved NYC Approved: MEA 89-92-E, Volume 35 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications:Available since 2006.Minimum Operating Pressure: Refer to the Approval Chart.Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar).Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric†) †Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C)Overall Length: 2-1/4” (58 mm) Material Standards:Frame Casting: Brass UNS-C84400 or QM BrassDeflector: Brass UNS-C23000, Phosphor Bronze UNS-C51000, or Brass UNS-C26000Bulb: Glass, nominal 3 mm diameterBelleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Polytetrafluoroethylene (PTFE) TapePip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400Compression Screw: Brass UNS-C36000For ENT coated sprinklers: Belleville spring - Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.)Sprinkler: Base Part No. 13637Order Sprinkler VK468 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera-ture rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JNTemperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = DFor example, sprinkler VK468 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 13637AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017) B. Wrench for recessed sprinklers: Part No. 13577W/B* (available since 2006)C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) *A ½” ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1” diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Replaces Form No. F_012706 Rev 17.1.P65 (Removed F-1 Escutcheon.) FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA Page 2 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Form No. F_012706 19.02.21 Rev 19.1 Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971)B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings3: ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat-ible with or suitable for the proposed environment. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. Figure 1: Standard Sprinkler Wrench 21475M/B FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA Page 3 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Form No. F_012706 19.02.21 Rev 19.1 Approval ChartViking VK468, 4.9 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base Part Number1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length Inches mm U.S.metric2 Inches mm 13637 VK468 1/2 15 4.9 70.6 175 psi (12 bar)2-1/4 58 Max. Coverage Area4 Ft.X Ft. (m X m) Ordinary Temp Rating (155 °F/68 °C) Intermediate Temp Rating (175 °F/79 °C)Deflector to Ceiling Installation Type Listings and Approvals3 Minimum Spacing Ft. (m) Flow4 GPM (L/min) Pressure4 PSI (bar) Flow4 GPM (L/min) Pressure4 PSI (bar) C-UL- US- EU5 VdS NYC6 NSF8 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 1-1/8 to 2 inch Standard surface-mounted escutcheons, or recessed with the Micromatic® Model E-1, E-2, or E-3 Recessed Escutcheon See Foot- notes 7 and 10. See Foot- notes 7 and 10. See Foot- note 7. See Foot- note 7. 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) 20 (75.7) 16.7 (1.15) Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 35. 7 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester9 8 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). 9 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA Page 4 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Form No. F_012706 19.02.21 Rev 19.1 Figure 3: Sprinkler VK468 Dimensions with a Standard Escutcheon Figure 2: Wrench 13577W/B for Recessed Sprinkler FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA Page 5 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Form No. F_012706 19.02.21 Rev 19.1 Figure 4: Sprinkler VK468 Dimensions with the Model E-1 and E-2 Recessed Escutcheons DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Pendent Sprinkler VK468 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614, F_080415 and F_080190 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, VdS, and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Replaces Form No. F_012706 Rev 17.1.P65 (Removed F-1 Escutcheon.) MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 1 of 6 Form No. F_060914 19.02.21 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length: 2-3/4” (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring - Exposed, Screw and Pip cap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F / 57 °C = A, 155 °F / 68 °C = B, 175 °F / 79 °C = D, 200 °F / 93 °C = E, and 286 °F / 141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F / 68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for recessed and/or wax coated sprinklers: Part No. 13655W/B** (available since 2006) **A ½” ratchet is required (not available from Viking). Replaces form F_060914 Rev. 17.1.P65 (Removed F-1 Escutcheon.) MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 2 of 6 Form No. F_060914 19.02.21 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 21475M/B Wrench Flat MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 3 of 6 Form No. F_060914 19.02.21 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 2: Wrench 13655W/B for Recessed Sprinklers Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. Sprinkler wrench 13655W/B** must be used for installing wax coated sprinklers. ** A 1/2” ratchet is required (not available from Viking)Step 2: Carefully press the wrench onto the sprinkler wrench flats. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C)100 °F (38 °C)Orange Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, and ENT coatings. MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 4 of 6 Form No. F_060914 19.02.21 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 For Light or Ordinary Hazard Occupancies Maximum 175 PSI (12 Bar) WWP Deflector must be located 4” to 12” (102 mm to 305 mm) below the ceiling. Base Part Number1 SIN Sprinkler Style Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria on page 43x.) NPT BSP U.S.metric2 Inches mm cULus4 LPCB 12997 VK305 HSW 1/2”15 mm 5.6 80.6 2-11/16 68 A1W, B1X, C2W, D2Z ------ 19782 VK305 HSW 1/2”--5.6 80.6 2-11/16 68 ------E3 NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 12121 VK305 HSW 1/2”15 mm 5.6 80.6 1-11/16 68 A1W, B1X, C2W, D2Z ------ Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) E - 155 °F (68 °C) Approved Finishes 1 - Brass, Chrome, White Poly-ester5,6, and Black Polyester5,6 2 - ENT5 3 - Chrome Approved Escutcheons W - Installed with standard surface-mounted escutcheons X - Installed with standard surface-mounted escutcheons or recessed with the Viking Micromatic® Model E-1, E-2, or G-1 Recessed Escutcheon Z - Installed with standard surface-mounted escutcheons or recessed with the Viking Micromatic Model E-1 Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • Locate with the deflector 4” to 12“ (102 mm to 305 mm) below the ceiling. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Align the top of the deflector parallel with the ceiling. • Locate no less than 4” (102 mm) from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 5 of 6 Form No. F_060914 19.02.21 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Quick Response Sidewall Sprinklers Maximum 175 PSI WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length FM Approvals3,4 (Refer also to Design Criteria below.)NPT BSP U.S.metric2 Inches mm 12997 VK305 1/2”15 mm 5.6 80.6 2-11/16 68 A1Y, B1X NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 12121 VK305 1/2”15 mm 5.6 80.6 2-11/16 68 A1Y, B1X Approved Temperature Ratings A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finishes 1 - Brass Approved Escutcheons X - Installed with standard surface-mounted escutcheons or recessed with the Viking Micromatic® Model E-1, E-2, E-3, or G-1 Recessed Escutcheon Y - Installed with standard surface-mounted escutcheons Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Viking vertical sidewall sprinklers may be installed pendent or upright. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Horizontal Sidewall Sprinkler VK305 is FM Approved as a quick response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. MICROFAST® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) TECHNICAL DATA Page 6 of 6 Form No. F_060914 19.02.21 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon 2-3/4” (68 mm)2-7/16” (62 mm) Installed with a Standard 1/8” Surface-Mounted Escutcheon Wall Opening Size: 2-5/16” (58.7 mm) minimum 2-1/2” (63.5 mm) maximum 1-5/8” (41 mm) Installed with the Threaded Model E-2 Recessed Escutcheon Wall Opening Size: 2-5/16” (58.7 mm) minimum 2-1/2” (63.5 mm) maximum 2-1/8” (54 mm) 2-1/4” (57 mm) Maximum Minimum 2-1/8” (54 mm) 2-5/8” (67 mm) Maximum 1-3/4” (45 mm) Minimum Installed with the Micromatic Model E-1 Recessed Escutcheon Replaces form F_060914 Rev. 17.1.P65 (Removed F-1 Escutcheon.) 7 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEApprovals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty SWIVEL MOUNT 3/8"8137957 SH-DSTR 1*1/4-20 X 1” TEKS 3 3220 (3/16”)1500 1475 .035”3/16”25 125 3/8"8268957 SH-TEK 50 12-24 x 1-3/4" TEKS 5 2368 (1/2" steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 1500 (Vertical) 850 (45° off Vertical) 4" 2-1/2” 3/16"1/2"25 125 1/2”8270957 SH-TEK 5.0 12-24 x 1-3/4” TEKS 5 2368 (1/2” steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 3/16"1/2"25 125 #14 Black Nut DriverPart # 8113910 Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Max Thickness Box Qty Case Qty HORIZONTAL MOUNT 1/4"8047957 SWD 100 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 1/4"8049957 SWDR 100 *1/4-20 x 1" TEKS 3 1900 (20 ga.).036"-20 ga 3/16"25 125 3/8"8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8055957 SWDR 1 *1/4-20 x 1" TEKS 3 1900 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8054957 SWDR 1-1/2 *12-24 x 1-1/2" TEKS 5 2375 (3/16")1500 1475 .188"-3/16"1/2"25 125 3/8"8056957 SWDR 516 *5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16").188"-3/16"1/2"25 125 #14 SW Red Nut Driver Part # 8114910 *Includes retaining nut • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • Manufactured in the U.S.A. • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. • Installs into angled z-purlin; allows threaded rod to hang plumb. • Allows 17° deflection from vertical. • Manufactured in the U.S.A. *Does not comply with ROHS requirements / Includes retaining nut Application Product Features SAMMYS SWIVEL HEAD™ FOR STEEL - Swivel Application SIDEWINDER® FOR STEEL - Horizontal Application Application Product Features #14 SH Orange Nut DriverPart # 8273910 Watch a video demonstration atwww.itwbuildex.com Watch a video demonstration atwww.itwbuildex.com OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 91 www.tolco.com Revision 12/18/2008 Fig. 200 - “Trimline” Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. • (21⁄2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size Note — Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 A B A B A B A B Fig. 200 1" - 2"Fig. 200 21⁄2" - 8" Fig. 200R 21⁄2" - 8"Fig. 200R 1/2" - 2" OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 72 www.tolco.com Revision 12/15/2008 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 98 - Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11⁄4 9500 360 11⁄2 13800 510 Dimensions • Weights Component of State of California OSHPD Approved Seismic Restraints System Size Range — Secures 3/8" thru 11⁄2" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 100 - All Thread Rod Full Length FIG. 98B FIG. 98 PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 1 OF 3 Stock No. 1144440 The Model VSR-S is a vane type waterfl ow switch for use on wet sprinkler systems that use 1" (25mm), 1¼" (32mm), 1½" (38mm) or 2" (50mm) pipe size. The unit may also be used as a sectional waterfl ow detector on large systems. The unit contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a fl ow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The fl ow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR-S switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A fi eld installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Installation These devices may be mounted in horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a valve, drain or fi tting which changes the direction of the waterfl ow. Select the proper paddle for the pipe size and type of TEE used see Fig. 1 for instructions on changing paddle. The unit has a 1" NPT bushing for threading into a non-corrosive TEE. See Fig. 2 for proper TEE size, type and installation. Use no more than three wraps of tefl on tape. Screw the device into the TEE fi tting as shown in Fig. 2. Care must be taken to properly orient the device for the direction of waterfl ow. The vane must not rub the inside of the TEE or bind in any way. The stem should move freely when operated by hand. The device can also be used in copper or plastic pipe installations with the proper adapters so that the specifi ed TEE fi tting may be installed on the pipe run. Note: Do not leave cover off for an extended period of time. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com UL, ULC, CSFM Listed and NYMEA Accepted Service Pressure: Up to 300 PSI (20,7 BAR) Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) UL Maximum Surge: 18 FPS (5,5 m/s) Enclosure: Die-cast, red enamel fi nish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Resistive 10mAmps min. at 24 VDC Conduit Entrances: Two openings provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Usage: Listed plastic, copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" (25mm) CPVC, one for 1" (25mm) CPVC (Central), one for 1" threaded Nibco CPVC, and one for 1 1/2" (38mm) threaded (Japan). Environmental Specifi cations: • NEMA-4/IP54 Rated enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fi tting. • Temperature range: 40° F to 120° F, (4,5° C to 49° C) UL Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090148 (See Fig. 7 for terminations) Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Installation must be perfomed by qualifi ed personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. 4440 PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 2 OF 3 COVER TAMPER SWITCH MOUNT SO ARROW ON BUSHING POINTS IN DIRECTION OF WATERFLOW 1” NPT THREADED FITTING ON ALL SIZES RUN OF THE TEE MAY BE THREADED OR SWEAT PIPE DIRECTION OF WATERFLOW DWG# 802-30A Fig. 1 Fig. 2 Notes: 1. The Model VSR-S has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other is used to operate a local audible or visual annunciator. 2. For supervised circuits see “Switch Terminal Connections” drawing and caution note (Fig. 3). Retard Adjustment The time delay is factory set at 30 ± 10 seconds. The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60- 90 seconds). The time delay should be set at the minimum required to prevent false alarms. Fig. 3 Switch Terminal Connections Clamping Plate Terminal OUT G OI N G INCO MI N G DWG# 923-3 To remove knockouts: Place screwdriver at edge of knockouts, not in the center. Screw the device into the tee fi tting as shown. Care must be taken to properly orient the device for the direction of waterfl ow. On sweat tees, no threaded bushings, inserts, or adapters are permitted, unless they comply with the dimensions listed in the chart below. Important - The depth to the inside bottom of the tee should have the following dimensions: DIRECTION OF WATER FLOW DWG# 737-31 Shown with optional Cover Tamper Switch Kit. DWG# 1146-4 DWG# 8810018-2 C (WHT) N.O. (RED) N.C. (BLK) Fig. 7 Cover Tamper Switch Wiring (Shown with cover in place) DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME 4,3MM (1 11/16”)APPROX. DEPTH DWG# 735-33 Approximate Depth Requirement Tee Size Threaded Sweat CPVC 1" x 1" x 1" 2 1/16" 1 3/4" 2 7/16" 1 1/4" x 1 1/4" x 1" 2 7/16" 2 7/16" N/A 1 1/2" x 1 1/2" x 1" 2 11/16" 2 1/4" N/A 2" x 2" x 1" 3 3/16" 2 3/4" N/A DWG# 1146-3A POSITIVE DC OR HOT AC NEGATIVE DC OR NEUTRAL AC WATERFLOW ZONE ON FIRE PANEL BELL EOLRCOMNCNO NONCCOMBreak out thin section of cover when wiring both switches from one conduit entrance. DWG# 1206-2 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Fig. 4 Typical Electrical Connections Fig. 5 Fig. 6 There are 12 paddles furnished with each unit. One for each size of threaded, sweat or plastic TEE as described in Fig. 2. These paddles have raised lettering that shows the pipe size and type of TEE that they are to be used with. The proper paddle must be used. The paddle must be properly attached (see drawing) and the screw that holds the paddle must be securely tightened.Do not use more than three wraps of tefl on tape. PRINTED IN USA MFG. #5401206 - REV G 12/08 VSR-S VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FOR SMALL PIPE PAGE 3 OF 3 Testing The frequency of inspection and testing for the Model VSR-S and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently.) An inspector's test valve (usually located at the end of the most remote branch line) should always be used for test purposes. If there are no provisions for testing the operation of the fl ow detection device on the system, application of the VSR-S is not recommended or advisable. A minimum fl ow of 10 gpm (38 Lpm) is required to activate this device. Please advise the person responsible for testing of the fi re protection system that this system must be tested in accordance with the testing instructions. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR-S waterfl ow switch should provide years of trouble- free service. The retard and switch assembly are easily fi eld replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030. There is no maintenance required, only periodic testing and inspection. DWG# 1206-5 GROUND SCREWS 3.50"5.56" (89.0 mm) (59.4 mm) 2.34" (141.2 mm) (52.3 mm) 4.89" 2.00" (50.8 mm) 1"-11 1/2 NPT Mounting Dimensions Waterfl ow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfl ow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfl ow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Use a wrench on the fl ats of the bushing. Turn the switch counterclockwise to disengage the pipe threads. • Gently lift with your fi ngers, roll the vane so it will fi t through the hole while continuing to lift the waterfl ow detector. • Lift detector clear of pipe. BELLS PBA-AC & MBA-DC 5400776 - REV Z • 11/17 PAGE 1 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4” (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Technical Specifications Dimensions 6” (150mm), 8” (200mm) and 10” (250mm) Enclosure Cover: Steel Finish: Red Powder Coat Base: non-corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) Voltages Available 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Environmental Limitations Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4” box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6”, 8” and 10” sizes In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. R * ULC on MBA-DC Only Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150)12VDC MBA-6-12 1750070 .12A 85 76 8 (200)12VDC MBA-8-12 1750080 .12A 90 77 10 (250)12VDC MBA-10-12 1750060 .12A 92 78 6 (150)24VDC MBA-6-24 1750100 .06A 87 77 8 (200)24VDC MBA-8-24 1750110 .06A 91 79 10 (250)24VDC MBA-10-24 1750090 .06A 94 80 6 (150)24VAC PBA246 1806024*.17A 91 78 8 (200)24VAC PBA248 1808024*.17A 94 77 10 (250)24VAC PBA2410 1810024*.17A 94 78 6 (150)120VAC PBA1206 1806120*.05A 92 83 8 (200)120VAC PBA1208 1808120*.05A 99 84 10 (250)120VAC PBA12010 1810120*.05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. * 5400776 - REV Z • 11/17 PAGE 2 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com BELLS PBA-AC & MBA-DC Wiring Rear View Installation Bell Dimension Inches (mm) Fig 1 Fig 3 2 11/16” (68 mm)DWG# 776-1 10” (250 mm)8” (200 mm)6” (150 mm) 5 3/4” (146 mm) 1 5/8” (41 mm) DWG# 776-2 3 3/8” (86 mm) 4 1/4” (108 mm) 3 3/8” (86 mm) 5” (127 mm) Weatherproof Backbox Dimensions Inches (mm) Fig 2 The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90” AFF and not less than 6” below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). MODEL BBK-1 OR HC-BBFailure to install striker down will prevent bell from ringing. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . Specifications Material: B16 Brass* Type: Single Outlet PL Sizes: 11/2” FNPT x 11/2” FNST Other Specifications: Integral Identification sign “Auto Sprinkler” with mounting holes. *Contains lead. Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Description Designed specifically residential sprinkler systems, the Single Inlet Connection features all brass* construction with an integrally cast mounting/identification plate. The connection comes equipped with a single 11/2” NST gasketed female threaded swivel inlet and a 11/2” NST plug to protect the threaded swivel from damage or the introduction of foreign materials when not in use. The out let is 11/2” NPT female thread for connect to the end of 11/2” threaded male pipe. The integrated identification plate has three drilled mounting holes for attachment to a mounting surface such as an exterior wall of a building or other structure. Fasteners used should be suitable for the material to which the connection is being attached. WWW.FPPI.COM Single Inlet Connection Installation Install according to applicable codes using customary installation methods for the installation of threaded connections. A suitable threaded sealant such as PipeFit Thread Sealing Paste with PTFE or PTFE thread Sealant Tape should be used. Where required, a check valve should be used to maintain system pressure. For Residential Systems, UL Listed