HomeMy WebLinkAboutAPPRVD SEPTIC PERMITSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
CONSTRUCTION PERMIT FOR: OSTDS New
APPLICANT: (Florida Power and Light)
PROPERTY ADDRESS: TBD Indrio Rd Fort Pierce, FL 34951
LOT: BLOCK: SUBDIVISION:
PROPERTY ID #: 1333-112-0010-000-3
PERMIT #:56 -SF -2037580
APPLICATION #: AP1466792
DATE PAID:
FEE PAID:
RECEIPT #:
DOCUMENT #: PR1306322
SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 1,500 ] GALLONS / GPD Septic new CAPACITY
A [ ] GALLONS / GPD CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ]
D [ 825 ] SQUARE FEET Drainfield new SYSTEM
R [ ] SQUARE FEET SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [x] MOUND [ ]
I CONFIGURATION: [x] TRENCH
N
F LOCATION OF BENCHMARK: Yellow Cal
I ELEVATION OF PROPOSED SYSTEM SITE
E BOTTOM OF DRAINFIELD TO BE
L
D I
0
T
H
E
R
BED [ ]
IR SE of system. ELEV 22.61
17.00][ INCHES FT ][ ABOVE BELOW BENCHMARK/REFERENCE POINT
12.00 ] [ INCHES FT ] [ ABOVE BELOW BENCHMARK/REFERENCE POINT
1LL L Z3.UU] INCHES EXCAVATION REQUIRED: [ 33.UU ] INCHES
System size for 3,520 square feet of office space and 2479 square feet of educational area and 12 students.
SPECIFICATIONS BY: Brian J Ingram TITLE: Environmental Specialist II
APPROVED BY: L ' yes ° TITLE: Environmental Specialist II St. Lucie CHD
Brian J Ing n
DATE ISSUED: 03/06/2020 EXPIRATION DATE: 09/06/2021
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 1 of 3
v 1.1.4 AP1466792 SE1255736
FDOH in St. Lucie County
Environmental Health
Site Plan Approved for Construction
Supersedes All Previous Site Plans for
OSTDS #56-5FZa375S-b & Well #
X2 -.12
Date:
Reviewer:
ALL WORK SHALL BE IN CONFORMANCE WITH SECTION 381.0065 FLORIDA STATU
THE FLORIDA ADMINISTRATIVE CODE.
DATUM NOTES:
1) ALL ELEVATIONS AND BENCHMARKS SHOWN HER
ARE RELATIVE TO THE NORTH AMERICAN VERTICAL
DATUM (N.A.V.D.) OF 1988.
I ,iJEWAFMAIR1PtCy
REV 1
DESIGNED BY DRAWN BY CULPEPPER S. TERPENIN,3, INC
PT 10/7/19 RN 10/7/19 CONSULTING ENGINEERS I LAND SIiRVEYO RS
CHECKED BY CHECKED BY IRI:E1 . FORTuORIz9xoSc1zs,hSr :RCI FLDA319x1On
PT ER 10/10/19 P1 NI, 7;z -464x537 . IAN 772464.9497 • ...... , -, g, ,
5'1i\'II.OFFI.ORID.ABOARD OF PROIRI ml).:,1.
ENGINEER OF RECORD: I:NN(:INIt1.Rc A('11IORI/,ALIO,\ NO.4za6
aWS P. MRPENING R,, P.E. NO 24276
FLORIDA POWER & LIGHT COMPANY
FPL INTERSTATE SOLAR
EDUCATION/OPERATIONS CENTER
X21.15 X21.52
NFIELD 4
UICK4 EQ. 36 /
HAMBERS
k
600 SF UNOBSTRUCTED AREA
k
INCRETE BOLLARD
YPICAL) k
SECURITY FENCING
k
I
k
X21.10
I
k /
k
X2205
k
TERp4
1 \
111111111
Y77
22 1 :\
Ni,
C,
v ES TERPENI
SEPTIC PLAN
MATIINTAIN At
MES THE
CONTIGUOUS
Fr.PF3&NF.IF.LD_ND
00
DRAINFIELD DIAGR
N.T.S.
FINISHED GRADE:
6" MIN. 18" MAX. C01
EL: 23.7
WET SEA
HIGH WA
EL: 2
6"-18"
12"
vent
FINISHED GRADE
35 QUICK4 EQ35 STRAIGHTLOCK CHAMBERS
FROM INFILTRATOR SYSTEMS OR APPROVED EQUAL BY OWNER
5' ABSORPTION AREA / 4" DRAIN PIPE WITH AN INVERT 6" FROM BOTTOM
I- T 14'-4" x 29'-6", OF DRAINFIELD
SAND OR SANDY
24" MIN. -
LOAM FILL
SLIGHT LIMITED"
SLIGHT LIMITED
NATURAL SOIL PER
SOIL CONSERVATION SERVICE
IS SP FINE GRAINED SAND
SECTION AT DRAINFIELD
N.T.S.
R E V I S I O N S
DATE I BY I DESCRIPTION I DATE BY I DESCRIPTION
721911.9 1 LIP I REV 1 SEPTIC
4" LOOSE ROCK
FILL WITH "SLIGHT LIMITED" SOIL.
SIZE OF REPLACED AREA — 14'-4"x 29'-8"
CENTERED ON DRAINFIELD AREA)
DESIGNED BY DRAWN BY CULPEPPER & TERISENING, INC
JP 10/7/19 RN 1D/J/19
ENGINEERS 1 LAND SURVEYORS
CHECKED BY
LIP
CHECKED BY
ER 10/10/19
CONSULTING
8010D'I'H 25,h S'I'RFI: f . PORI' PILRCG, FLORIDA 344X1
PIIONF.772-464-3537 . FAX772-464-9497.....,„-„R.- .,
ENRNEER OF RECORD:
JAMES P. /ERPEMNG JP, P.E. NO. 24276
MP l': 1:'C; OF FLORIDA ROARD OP PROFRSSIONALINFFMAU111ORIZATIMNO. 4286
TRAFFIC GUIDE POST
4.5"1 HIGH DENSITY
POLYETHYLENE, YELLOW
FPL PART #180-74005-0
5' SPACING ADJACENT
h TO PAVED AREAS
I
10' SPACING ADJACENT
TO UNPAVED AREAS
FINISHED GRADE
B" PVC
18" DIA.PACKED DRY
io WITH CONCRETE MIX
89 ROCK
BOLLARD DETAIL
N.T.S.
REMOVABLE TRAFFIC GUIDE POST)
FLORIDA POWER & LIGHT COMPANY
FPL INTERSTATE SOLAR
EDUCATION/OPERATIONS CENTER
SEWER CLEANOUT
BY CONTRACTOR
N.T.S.
FLR. TO BE MIN.
ROVE FIN. GRADE
FINISHED FLOOR: 26.2
FINISHED GRADE: 25.7
UILDING
NOTES
1. SUBSURFACE SEWAGE DISPOSAL SYSTEM SHALL COMPLY WITH CHAPTER 64E-6 OF THE RULES
OF THE DEPARTMENT OF HEALTH AND REHABILITATIVE SERVICES "STANDARDS FOR ON—SITE
SEWAGE DISPOSAL SYSTEMS"
2. THE SEWAGE DISPOSAL SYSTEM IS CONFIGURED TO PROVIDE THE FOLLOWING MINIMUM
CLEARANCES TO EXISTING/PROPOSED STRUCTURES:
DISTANCE TO PRIVATE POTABLE WELL
AS MEASURED FROM NEAREST CORNER OF DRAINFIELD ...........................100'
DISTANCE TO LIMITED USE
NONCOMMUNITY OR OTHER PUBLIC POTABLE WATER WELL .......................100'
DISTANCE TO PUBLIC POTABLE WELL. SYSTEM.. ......................................... 200 .
DISTANCE TO NONPOTABLE WELL...............................................................50'
DISTANCE TO POTABLE WELL LINE...............................................................10'
DISTANCE TO STRUCTURE FOUNDATIONS................................................1.'..{i DISTANCE
TIDAL WATER
SM
I
STREAMS, CANALS AND DRAINAGE STRUCTUR
DISTANCE TO DESIGN HIGH WATER LINE F
INDIVIDUAL STORM WATER DRY RETENTION AREAS ........... .. .... p. " CEN RAF//iiiDISTANCETOPROPERTYLINE ....................
3. SEPTIC TANK EFFECTIVE CAPACITY OF 1.500 GALLONS, .QA MATED SEWAGE FLOW
OF 695 GALLONS PER DAY (GPD).
0.
4. DRAINFIELD AREA OF 1,064 SQ.FT.(MINIMUM) BASED O S AGE LOAD) RATE4T07 I..
BOTTOM OF 0.80 GALLONS PER SQUARE FOOT PER
JA RPENIIJ
F.C': 24276,°
SEPTIC TANK & G { 1",L_ NO.
I11II11II
DRAINFIELD DETAILS
2
i
5/8" Iron Rod & Cap /
AMECFW TRAVERSE" HV3
ELEVAMN-= 24.61'
F-
5.53
23.77
23. 4
X2I1.64
X 2
96
X X X j(2'.76 X
X23.48
X22.72
X22.32
X22.49
X22.65
X2216
X21.89
X-z a. Ite---
X24 29 X23 99
I X19 56 X19.81
II
X18.83 X18.30
1 9 -X 89 X X21 X1-- X X21.28X
1
X22.24 X22 21 X22.27
X21.95
X22.14
DATUM NOTES:
1) ALL ELEVATIONS AND BENCHMARKS SHOWN HEREON
ARE RELATIVE TO THE NORTH AMERICAN VERTICAL
DATUM (N.A.V.D.) OF 1988,
rRIAA L1yl
REV 1 SEPTIC
X22.40
X22.15 /
Y7
CULPEPPER TERPENING, INCDESIGNEDBYDRANKBY
PT 10/7/19 RN 10/7/19
CHECKED BY CHECKED BY
W T m 10/10/19
V"iaw or N COM
M"a P. wwu&YO ,F, P£ Na 2,WX
X22.05
CONSII LTINO ENGINEER`} I LAND SURVEYORS
2nRII SOUL 1125,h ifRl: l:'I' . P[) 11'1FRCF,l'1.()xll),1 -M
PIRri1.rz-46-'.3537. ras„z-464-nam ......,,.
srn rn. oP PLowun aonw)or rxonaslo.
17NGINF1: $ k IOR14M[OS VO 4:96
LJ. 8
X23.94
X19.26
X18.47
X 21.76 X
TD -H in St. Lucie County
Environmental_ Health
Site Plan Approved for Comtruction
Supersedes All Previous Site Plansfo-T
OSTDS #(,-3 2® 7`S & Well #
Date:
Reviewe
X23.48 i 2 59 22.98
19.14
JC22.31 2"2'75XX1 2 21.86
X18.54 X1 407 X2k1,
X2..76 X21.26 X . '1 X21,26 .36
X X X X X
SEPTIC TANK AND
k I-
DRAINFIELD
X21 90
2 .77 X21 5 X2
k
X2_ x /
X2-.40 /
X21.1 /
X21.07
k
X22/05
X71 13
i I
x21.16
X20.25 \ \
FLORIDA POWER & LIGHT COMPANY
FPL INTERSTATE SOLAR
EDUCATION/OPERATIONS CENTER
SEPTIC EXHI BI T
SHEET
NO.
r
4§
I
FDOH in St. Lucie County
Environmental Health
Site Plan Approved for Construction
Supersedes All Previous Site Plans for
OSTDS #6-Sf Z*37,5&<-- & Well #
Date: 2-U
Revile
Exterior Wo'IPack Lighting
Exit Sign and Emergency Lights
o Over Door Light Fixture
Data outlet
R 120 VAC Diplex outlet
4 Quad Receptacle
f 220 VAC Outlet amperage labeled
Ground Fault Receptacle
Weather Proof Ground
Foult Receptacle
Exhaust Fan with light
4040 ff, Pk.0qQ
Notes
1. The General Contractor shall provide the layout, design
and technical specifications for the building electrical system, office area lighting, telephone, communication system, and the
HVAC. This shollinclude the meter socket, load center, light
switches, receptacles, exit signs, exterior wallmount fixtures,
restroom ceiling fans, occupancy sensors, and dimmer switches.
See additional Mechanical and Electrical Requirements on Sheet 5.
2. The completed systems shall be furnished and installed in
order to be able to obtain a Building Occupancy Permit, be in
accordance with the latest edition of the Notional Electrical Code,
and all other applicable local and state code requirements.
0 10
FEET
E
Nm
W UO
1 Q TP
Z WOLLinm
O m
2C3
J 5
U — Z CJ0N
M
Z N
a N
J
Z
a -
W
J VJ —
Z
O_
m w
r
Z
O cam \
w
7
CL W
O o F--
W
Z Q
C7 z —
o v
OCOaO
F- z C0
a
o
U
J
O v W
J v
W Z
LLL w N
SNYDER
ASSOCIATES
1 Project No: 1190346 1
Sheet 3 of 5