HomeMy WebLinkAboutproduct approval (3)16/20/22 kW GENERAL' _ specifications C vlz:xr of 3r' 07043 0 Model Rated Maximum Continuous Power Capacity (LP) Rated Maximum Continuous Power Capacity ING) Rated Voltage Rated Maximum Continuous Load Current — 240 Volts (LP/NG) Total Harmonic Distortion Main Line Circuit Breaker Phase Number of Rotor Poles Rated AC Frequency Power Factor Battery Requirement (not included) Unit Weight (Ib/kg) Dimensions (L x W x H) in Sound output in dB(A) at 23 It (7 m) with generator operating at normal load' Sound output in dB(A) at 23 it (7 m) with generator in Quiet -Test" low -speed exercise mode`" G007035-0, G007036-0, G007038-0, G007039-0 G007042-0, GO G007037-0 (16 kW) (20 kW) (22 kW) 16,000 Watts' 20,000 Watts' 22,000 16,000 Watts* 18,000 Watts' 19,500 240 240 240 66.6/66.6 83.3/75 91.6/81.3 Less than 5% Less than 5% Less than 5% , 70 Amp 100 Amp 100 Amp 1 1 1 2 2 2 60 Hz 60 Hz 60Hz 1.0 1.0 1.0 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum 406/186 448/203 466/211 48 x 25 x 29/1218 x 638 x 732 66 66 67 58 58 58 5 min 5 min 5 min Engine GENERAL G Force 1000 Series Type of Engine 2 2 2 Number of Cylinders 999 cc 999 cc 999 cc Aluminum w/ Cast Iron Sleeve Cylinder Blocsplacement Cylinder Block Overhead Valve Overhead Valve Overhead Valve Valve Arrangement Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto Ignition System Electronic Electronic Electronic Governor System 9.5:1 9.5:1 9.5:1 Compression Ratio 12 Vdc 12 Vdc 12 Vdc Starter Oil Capacity Including Filter Approx.1.9 1 L Approx.1.9 gV1.8 L Approx.1.9 gV1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas ION (ma/hr) 1/2 Load 218 (6.17) 204 (5.78) 216 (6.12) Full Load 309 (8.75) 301 (8.52) 310 (8.78) Liquid Propane fta/hr (gal/hi [Vhrj 1/2 Load 91.6 (2.52) [9.53) 86 (2.37) [8.99] 93.2 (2,56) [9.70) Full Load 106.8 (2.94) (11.111 129.6 (3.56) [13.481 140 (3,87) [14.65] Note, Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercu(y) for natural gas, 10-12'' water column (19-22 mm mercury) for LP gas. For Btu content, multiply fta/hr x 2500 (LP) or I0/hr x 1000 (NG). For Megajoule content, multiply ri x 93.15 (LP) or m3/hr x 37.26 (NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons:Auto CAutomatic Start on Utility failure. '7'day exerciser. Manual Start with starter control, unit stays on. 11 utility falls, transfer to load takes place. Off :;. Stops unit. Power is removed. Control and charger still operate. a Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) rom 140-171 V119O-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard _ RuNAlarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking, 16 sec on, 7 rest (90 sec maximum duration). Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration BS5514, IS03046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with level; also will decrease about 1 percent for each 6 °C (101) above 16 °C (60 fl. content. ambient temperature. altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feel (304.8 meters) above sea and