HomeMy WebLinkAboutproduct approval (4)GENERAC4
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 circuits, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
• 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
Height
Width
H1
H2
W1
W2
Depth
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
1 343.0
175.4
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
2/0-#14
2/0-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• 2 pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120/240, to
Open Transition Service Rated
Height
Width
Depth
H1
H2
W1
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
Model
G007036-0 (16kW)
No, of Poles
2
Currenl Rating (Amps)
100
Voltage Rating (VAC),
120/240,10 - g
Utility Voltage Monitor (Fixed)*
-Pick-up
80%
-Dropout
65%
Return to Utility'
approx.15 sec
Exereses bi-weekly for 5 minutes`t
Standard
UL Listed
Standard
Total Circuits Available
16
Tandem Breaker Capabilities
a spaces
Circuit Breaker Protected
Available RMS Symmetrical
10,000
Fault Current (_u) 250 Volts
*Function of Evolution Controller
Exercise can be set to weekly or monthly
DEPTH
Model
No. of Poles
Current Rating (Amps)
Voltage Rating (VAC)
Utility Voltage Monitor (Fixed)'
-Pick-up
-Dropout
Return to Utility'
G007037-0 (16 kW)/G007039-0 (20 kW)/
G007043-0 (22 kW)
2
200
120/240,10
Exercises bi-weekly for 5 minutes'
UL Listed
Enclosure Type
Circuit Breaker Protected
Lug Range
*Function of Evolution Controller
Exercise can be set to weekly or monthly
80%
655,
approx. 13 sec
Standard
Standard
NEMA/UL 3R
22,000
250 MCM - #6