HomeMy WebLinkAboutGENERAC, product approvalGENERAC"
16/20/22 kW
INCLUDES:
• True Power'" Electrical Technology
• Two Line LCD Multilingual Digital
Evolution'" Controller (English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
• Electronic Governor
• System Status & Maintenance Interval LED
Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz
Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz
• Capability to be installed within 18" (457 mm)
of a building*
FEATURES
�) INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended run times in high temperatures and extreme operating conditions.
O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5% Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
O TEST CRITERIA:
.f PROTOTYPE TESTED
v SYSTEM TORSIONAL TESTED
NEMA MG1-22 EVALUATION
MOTOR STARTING ABILITY
.•7
c i us QUIE -F
LISTED
Note. CUL certification only applies to unbundled units and units packaged with
limited circuit switches. Units packaged with the Smart Switch are UL certified to
the USA only.
*Only if located away from doors, windows and fresh air intakes,
and unless otherwise directed by local codes.
SOLID-STATE. FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at -_1%.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
GENERAC TRANSFER SWITCHES: Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
L-Lj GENERAC
Mobile,
* a*
PROMISE `TrOMEPGP �NHRAN LflrC
GENERAC
16/20/22 kW available accessories
Model #
G006463-4
G005819-0
l
G007101-0
Product
Mobile Link'"
26R Wet Cell Battery
Battery Pad Warmer
G007102-0 Oil Warmer
G007103-0
G005621-0
G007027-0 - Bisque
G005703-0 - Bisque
G006485-0
G006873-0
Breather Warmer
Auxiliary Transfer Switch
Contact Kit
Fascia Base Wrap Kit
(Standard on 22 kW)
Paint Kit
Scheduled Maintenance Kit
Smart Management Module
(50 Amps)
Description
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac-
cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or
text message when a change in the generator's status occurs. Available in the U.S. only.
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact®).
The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below 0°F.
(Not necessary for use with AGM -style batteries).
Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below
0°F.
The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy icing occurs.
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load
you may not need. Not compatible with 50 amp pre -wired switches.
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from
future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator
enclosure.
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generac automatic standby generator.
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
power management capabilities. It provides additional power management flexibility not found in any other
power management system.
dimensions & PCs
n Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
J2
rm.e M
[25.5 in)
LEFT SIDE VIEW
1218 mm
FRONT VfhW
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007042-0
696471070422
G007043-0
696471070439
GENE RAC ` Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
s2016 Generac Power Sysiems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000000194-0 10/24/16
GENERAL'
1 f /gn/22 kw
Limited Circuits Switch Features
• 16 circuits, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
• 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
Height
Width
Depth
H1
H2
W1
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
2/0-#14
2/0-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• 2 pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120/240, to
Open Transition Service Rated
Height
Width
Depth
H1
H2
W1
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
switch options
Model
G007036-0 (16kW)
�
�'C.,t Rating (Amps)
100
Utility Voltage Monitor (Fixed)*
80%
-Pick-up
-Dropout
65%
Exercises bi-weekly for 5 minutes*t
Standard
Total Circuits Available 16
�,1
r _ xr
,
Circuit Breaker Protected
Available RMS Symmetrical
10,000
Fault Current @ 250 Volts
*Function of Evolution Controller
Exercise can be set to weekly or monthly
G007037-0 (16 kW)/GO07039-0 (20 kW)/
Model
6007043-0 (22 kW)
Current Rating (Amps)
200
Utility Voltage Monitor (Fixed)*
-Pick-up
80%
Dropout
65%
Exercises bi-weekly for 5 minutes*
Standard
Enclosure Type
NEMANL 3R
Lug Range
250 MCM - #6
*Function of Evolution Controller
Exercise can be set to weekly or monthly
3
4F'
a q.
I DEPTH
GENERAC'
specifications
16/20/22 kW
.¢�
G007035 0, G007036-0, G007038-0, G007039-0 G007042.0, G007043-0
Model
G007037-0 (16 kW) (20 kW) (22 kW)
16,000 Watts" 20,000 Watts" 22,000
Rated Maximum Continuous Power Capacity (LP)
16,000 Watts" 18,000 Walls` 19,500
Rated Maximum Continuous Power Capacity ING)
240 240 240
Rated Voltage
66.6/66.6 83.3/75 91 6/81.3
Rated Maximum Continuous Load Current — 240 Volts (LP/NG)
Less than 5% Less than 5% Less than 5%
Total Harmonic Distortion
70 Amp 100 Amp 100 Air p
Main Line Circuit Breaker
1 1 1
Phase
2 2
Number of Rotor Poles
60 Hz 60 Hz 60Hz
Rated AC Frequency
1.0 1.0 1.a
Power Factor
12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum
Battery Requirement (not included)
406/186 448/203 466/21 1
Unit Weight (Ib/kg)
48 x 25 x 29/1218 x 638 x 732
Dimensions (L x W x H) inlmm
66 66 67
Sound output in dB(A) at 23 it (7 m) with generator operating at normal load`"
558 58
Sound in dB(A) at 23 it (7 m) with generator in Quiet -Test`" low -speed exercise mode"'
5 5 min
output
5 min min
Exercise duration
Engine
GENERAC G-Force 1000 Series
Type of Engine
2 2 2
Number of Cylinders
999 cc 999 cc 999 cc
Displacement
Aluminum w/ Cast Iron Sleeve
Cylinder Block
Overhead Valve Overhead Valve Overhead Valve
Valve Arrangement
Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto
Ignition System
Electronic Electronic Electronic
Governor System
9.51 9.5:1 9.5:1
Compression Ratio
12 Vdc 12 Volt; 12 Vdc
Starter
Approx.1.9 qi L Approx.1.9 gV1.8 L Approx.1.9 qVl .8 L
Oil Capacity Including Filter
3,600 3,600 3,600
Operating rpm
Fuel Consumption fla/hr (ma/hr)
Natural Gas
218 (6.17) 204 (5.78) 216 (6.12)
1/2 Load
309 (8.75) 301 (8.52) 310 (8.78)
Full Load
Liquid Propane tt3/hr (gal/hr) [Vhr]
91.6 (2.52) [9.53] 86 (2,37) [8.991 93.2 (2.56) [9.701
1/2 Load
106.8 (2.94) [11.111 129.6 (3.56) 113.481 140 (3.87) [14.651
Full Load
n rFarfuel inlet all load, ranges
full load.Requiredfuelpressuret generator
ll3ph
- 3.5-7' water column -13 mm mercury)for natural gas.10-12" water column (19-22 mm mercury)
be sizedf or
Megajoulat
x 37
Note�Fguael pop or x m%hr x 9315 (LP) or
(LP(
hT 2500
os. Btu
Controls
Simple user interface for ease of operation.
2-Line Plain Text Multilingual LCD Display
Automatic Start on Utility failure. 7 day exerciser.
Mode Buttons:Aulo
Start with starter control. unit stays on. It utility tails, transfer to load takes place.
Manual
Stops unit. Power is removed. Control and charger still operate.
Off
Standard
Ready to Run/Maintenance Messages
Standard
Engine Run Hours Indication
Standard (programmable by dealer only)
Programmable start delay between 2-1500 seconds
From 140-171 V/190-216 V
Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting)
Standard
Future Set Capable Exerciser/Exercise Set Error Warning
50 Events Each
RurVAlarm/Maintenance Logs
Cyclic cranking 16 sec on, 7 rest (90 sec maximum duration).
Engine Start Sequence
Starter cannot re-engage until 5 sec after engine has stopped,
Starter Lock -out
Standard
Smart Battery Charger
Standard
Charger FaulVMissing AC Warning
Standard
Low Battery/Battery Problem Protection and Battery Condilion Indication
Standard
Automatic Voltage Regulation with Over and Under Voltage Protection
Standard
Under-Frequency/Overload/Stepper Overcurrent Protection
Standard
Safety Fused/Fuse Problem Protection
Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown
Standard
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown
Standard
High Engine Temperature Shutdown
Standard
Internal FaulUlncorrect Wiring Protection
Standard
Common External Fault Capability
Standard
Field Upgradable firmware lot
"Sound levels are taken from the front of the generator. Sound levels taken from other Sidenof cordancehe awith BS5514tor may be 19 S03046 anher ld 01N6271) ' Maximung on installation m kilors volt amps ating iand currennitions t are 6subjey. ct o and liimiled by such facctors as fuel Btu/megaioule
).
is for this rating. (AII ratings accordance for each 6 °C (10 °F) above 16 °C (601).
of the utility power outage. No overload capability available
Maximum decreases about 3.5 Percent fw
each 1,000 feet (304.8 meters) above sea level: and also will decrease about percent
content, ambienl temperature, attitude, ongmo power and condition, etc. Power
•
GENERAL'
features and benefits
16/20/22 kW
Engine
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine
• Generac G-Force design
run cooler, reducing oil consumption resulting in longer engine life.
• "Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
less maintenance and longer engine life. Now featur-
• Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance,
ing up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown
Prevents damage due to overheating.
Generator
Allows for a smaller, light weight unit that operates 25%more efficiently than a revolving armature generator.
• Revolving field
Produces a smooth output waveform for compatibility with electronic equipment.
• Skewed stator
• Displaced phase excitation
Maximizes motor starting capability.
• Automatic voltage regulation
Regulates the output voltage to ±1% prevents damaging voltage spikes.
• UL 2200 listed
For your safety.
Transfer Switch (if applicable)
• Fully automatic
Transfers your vital electrical loads to the energized source of power.
• NEMA 3R
Can be installed inside or outside for maximum flexibility.
• Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
Evolution'" Controls
• Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
• Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
• Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
• Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
• Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
from the factory default setting of 5 seconds by a
• Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds
qualified dealer.
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
• Engine warm-up
• Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
• Smart battery charger
Compatible with lead acid and AGM -style batteries.
• Main line circuit breaker
Protects generator from overload.
• Electronic governor
Maintains constant 60 Hz frequency.
Unit
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
• SAE weather protective enclosure
mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive
Makes for an easy, eye appealing installation, as close as 18" away from a building.
Instaifation System
• 1 it (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system,
• Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.