HomeMy WebLinkAboutcmpmaindrainspecsi
232 GPM POOL DRAIN 12 "x12 " Ea MalGpk rsinu¢pny COGI-2°°&
232GPM-Subme,ged MPLIANT
CMP# 25508-12X-000L* Foorowarsi
25$0$-, 2XL'
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
ALWAYS PLUMB AND INSTALL ALL SUCTION FITTINGS ACCORDING TO ALL BUILDING CODES THAT APPLY IN YOUR AREA.
WARNING: When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 ft or they
must be located on two different planes (i.e., one on floor and one on the wall).
WARNING: DO NOT locate suction outlets on seating areas or on backrests for such seating areas_
The maximum flow rating for this suction fitting is 232 GPM. This suction fitting is designed for installation in conjunction with at least
one other suction fitting per pump. A minimum of 5" SCH 40 PVC pipe is to be used. Field built sumps should be constructed per
ANSI/APSP-16 Figure 2 (see below) found on page 5 of the Standard. Suction fitting and fasteners should be observed for damage
or tampering before each use. Missing, broken, or cracked suction fittings shall be replaced before use. Loose suction fittings shall be
reattached or replaced before use. Contact your local pool and spa professional for all winterizing instructions and recommendations.
Open area of grate is 70.80 in2.
Head Loss
NOTE: This drain is certified for FLOOR OR WALL USE. 40
(Pa x 103 ) Resuhs moyvory- thisdota isprovidedforreference only.
Tools Needed: Phillips Head Screwdriver
INSTALLATION INSTRUCTIONS
1. Construct sump per ANSI/APSP-16
Figure 2 (see below)
2. Secure mounting frame in concrete_
3. Use mounting screws to secure grate to frame.
NOTE: In the event that one suction outlet is completely blocked,
the remaining suction outlet(s) serving that system MUST have a
flow rating capable of the full flow of the pump(s) for the
specific suction system.
NOTE: Increasing size of the pump may increase flow rate of
suction beyond rated safety limits causing entrapment or death.
CAUTION: Hair or body parts blocking the spa or pool suctions
may become trapped and held against the suction fitting.
Entrapment against the suction fittings can result in drowning or
other severe injury. Never sit on or lean up against suction
fittings. Never exceed the maximum allowable flow rate stated
on the suction fitting. The suction fitting and fasteners should
be inspected for damage or tampering before each use of the
facility. Missing, broken, or cracked suction fittings shall be
replaced before using this facility. Loose suction fittings shall be
reattached or replaced before use of this facility.
20
D 100
Flow (GPM)
e.5 D min. D men.
O min.
A
i.5Dmia-
GFNE,RpL NOTES:
W 0 — emfde diameter d pipe•
Ib) All mmenvans sh— aK minimums.
{Q A hralxn One --) indimtes su8ge11ed sump <onrignrarion.
300
REPLACEMENT PARTS
1% r.11ii1r1Yr+
of
l�irti�
Grate Frame Screw
25508-12X-011 L rX" specifies color) 25508-12X-020 ("X" specifies color) 610013-1142-028
*Replace within 7 installed years or immediately upon evidence of degradation or damage_
WARNING: To reduce the risk of drowning from hair and body entrapment install suction fittings with a marked flow rate in gallons per minute that exceeds the flow
rate of your system by at least 25%. Always use multiple suction outlets. If the fitting/cover breaks, is damaged, or is missing, shut the system down immediately. Do not
use the system until damaged parts have been replaced.
WARNING: Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times_ Persons with long hair should secure hair to a minimal length
or wear swimming cap. Children should never be left unattended at anytime in a swimming pool, spa, or bathtub. Be sure the temperature of the water never exceeds
the manufacturer's recommendations_