FL # FL2569-R17
Application Type Revision
Code Version 2017
Application Status Approved
Comments -`� STD
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 0000a
(819) 478-2400
memathieu@sop rema .ca
Authorized Signature Marc -Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative lean -Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich, PE
" Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R17 QQJ 2019 01 CQJ N E f
Referenced Standard and Year (of Standard) standard Year
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012 (04-12) 2012
UL 1897 2012
https:Ilfloridabuilding.orglprlpr app_dtl_aspx?param=wGEVXQwtDgsKQFEnckB108Erx1Ud3xYidim5DHmBOirHHIZrZrmt%2bA%3d°/3d 112
2/26/2020
Florida Building Cafe Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
08/14/2019
Date
Validated
08/14/2019
Date
Pending FBC Approval
08/17/2019
Date
Approved
t0/15/2019
Date
Revised
02/12/2020
of
FL # t Model, Number or Name
2559.1 _ Soprema Roof Undedayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impart Resistant: N/A
Design Pressure: fN/A/-150
Other: 1,) Refer to ER Section 5 for Limits of Use. 2..) The
design pressure noted herein pertains to underlayment systems
used beneath adhesive -set the systems. Refer to ER Section
15.6,4 for details.
Description
Self adhering roof underlayments
installation Instructions
FL2569 R17 II 2Q1.906 FINAL_ER Fi_2569�77 Pf
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
Created by lnddeependent Third Party: Yes
i
IME
Centact Us :: 2601 Blair Stone Road, Tallahassee FI- 32399 Phone: SSC-487-1624
The State of Florida is an AA/EEO employer. Epyrioht 20Q7-2013 State of_Fl9rida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Vnder Florida law, email addresses are public records. If you do net wart your e-mail address released to response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.467.1395. "Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Departrnent with an email address If they have one. The emails
provided may be used for official communicatlan with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address winch can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product
Approval Accepts:
Credit Caret
Safe
https:/Ifloridabuiiding.org/prfpr_app_dti.aspx?param=wGEVXQWtDgsKQFEnckBl 08Etx1 Ud3xYidim5DHmBOirHHiZrZrmt%2bA%3d%3d 212
u
NEMO I eft.
Certificate of Authorization #31455
353 Christian Street, Unit##13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
Soprema, Inc. Evaluation Report 518010.06.09-1115
1640 rue Haggerty FL2569-11 7
Drummondville, Qu6bec J2C 5P8 Canada T
Date of Issuance: 06/15/2009
(819) 478-2400 Revision 15: 06/19/2019
SCOPE: CY/
This Evaluation Report is issued under Ruie 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE- This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report bythe named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO(etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
0,'
o;,X
Robert J.M. Nieminen, P.E.
or " Thefarsitnde seal appearing was authorized by Robert
Nieminen, P.E. on 06/19/2019. This does not serve as an
Florida Registration No. 59166, Florida DCA ANE1983
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Hobert Nieminen, R.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEWv etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
NEMO I etc.
ROOFING COMPONENT EVALUATION:
1. •-
Product Category:
Roofing
Sub -Category:
Undedayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 61'
Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
STANDARDS:2.
Section
Pro a
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, 1507.2.9.2, R905.1.1,
Physical Properties
ASTM D1970
2015
R905.2.8.2
1507.3.3, R905.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physicai Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
ASTM D4798
2011
Enti
Examination
Reference
Date
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM D1970 / TAS 110 (QC)
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
FRSA/TR104-12(OH)
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970 (OH)
537210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970(MS)
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TRI 04-12 (N15)
S43530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 (BC)
S44870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D1970 (QC)
544870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
F-RD(TST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
540540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SCS520.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
M-0 (CrR7S92)
HVH7 Compliance
18-0329.03
06/28/2018
ICC-ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
NEMO (TST6049)
ASTM D1970 /TAS 110 (QC)
SOPC-SC8970.08.15-R1
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
NEMO (TST6049)
ASTM D4798/01970 (OH & MS)
45-SOPC-18-002.05.19.A
05/31/2019
PRi(TST5878)
ASTM 01970(MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
07/18/2017
MEMO ETC, LLC Evaluation Report S18010.06.09-1115
Certfcote of Authorrration #32455 61" EDMON 120171 FBC NON-HVHZ EVALUATION FL2569-1117
Soprema Roof Onderlayrnents Revision 15,.06/1912019
Page 2 of 8
ONEMO I etc.
Product
Specification
Plant(s)
Description
4.1 Lastobond TO HT
ASTM 01970 and
Gulfport, MS
self -adhering, non -woven polyester fabric surfaced,
FRSA/TRI April 2012
sBs modified bitumen roof underlayment
4.2 Lastobond Shield
ASTM D1970
Drummondville, QC
seif-adhering, woven polyethylene surfaced, 5B5
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.3 RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment
40
4_4 Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SSS modified bitumen roof
underlayment
4.5 Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
seif-adhering, woven polyethylene surfaced, SB5
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.6 Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
4.7
temperature, SBS modified bitumen roof
underlayment
q.g Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -surfaced,
Wadsworth, OH
SB5 modified bitumen roof underlayment
4,g Lastobond Eaves
ASTM D1970
Gulfport, MS
seif-adhering, glass -mat reinforced, sand -surfaced,
Protection Sheet
Wadsworth, OH
SBS modified bitumen roof underlayment
4.10 I Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, MS
5B5 modified bitumen roof underlayment
Wadsworth, OH
4.11 Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced,
Wadsworth, OH
SBS modified bitumen roof underlayment
HT
4.12 PrimeSource Grip -Rite
ASTM D1970
Gulfport, M5
self -adhering, glass -mat reinforced, film -surfaced,
Wadsworth, OH
SBS modified bitumen roof underlayment
Smooth Seal HT
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
4,13 RESISTO LB1236
Gulfport, MS
595 modified bitumen roof underlayment
Wadsworth, OH
4.14 PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, M5
SBS modified bitumen roof underlayment
Eave & Valley Protector
�
Wadsworth, OH
4.15 RESISTO LB1244
ASTM D1970
Drummondville, QC
self adhering, glass mat reinforced, sand -surfaced,
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4. 6 �Call)heneFRGR
ASTM D1970 and
Gulfport, MS
self -adhering, fiberglass reinforced, granule-
FRSA/TRI April 2012
Wadsworth, OH
surfaced, SB5 modified bitumen roof underlayment
5.1 This is a building code evaluation- Neither MEMO ETC, LLC nor Robert Nierninen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Evaluation Report S18010.05.09-R15
MEMO ETC, LLC FL2569-R17
Certificate atAuthariration #32455 6'" EDITION (2017) FBC NOl1-HVHZ EVALLiATIOH
Soprerna Roof underlayments Revision 15: 06/1912019
Page 3 of 8
4cllkk
WNEMOjeft.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof coverwhere the product is specifically referenced
within FBC approval documents. if not listed, a request maybe made tothe Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVEROPTIONS
Wood or Slate or
Asphalt Mail -On Foam -On Composite
Underiayment Metal Composite
Shingles Tile Tile Shakes & Slate
Shingles
Lastobond TU HT Yes Yes Yes Yes Yes YesSee 5.5.1
Lastobond Shield / Pro HT-N / Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT / Pro HT-S Yes No No Yes Yes Yes
EnviroShield Yes No No Yes Yes Yes
Lastobond Eaves Protection Sheet / Yes No No No Yes Yes
Lastobond 19S
Lastobond ECO / RESISTO LB1235,
Grip -Rite Eave & Valley Protector / Yes No No No Yes Yes
RESISTO LB1244
Lastobond Smooth Seal HT / Grip- Yes No No Yes Yes Yes
ffC,lph,,,
Smooth Seal HT
FR GR Yes Yes No No Yes Yes
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
5.6
Underlayment Adhesive Florida Product Approval
Lastobond TU HT
Dow TileBond'" FL22525
ICP Adhesives Poiysete NH-160 FL6332
Allowable Substrates:
Underlayment Primer Substrates
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA (Optional) ASTM D41, plywood, OSB, Southern Yellow
SMOOTH PLY 40, Lastobond Shield HT, Lastabond Pro HT-S, Elastocol Stick, Elastocol Stick Pine (SYP)
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Zero
Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,
Grip -Rite Eave & Valley Protector, RESISTO LB1244, ASTM D41 structural concrete
Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT
(Optional) ASTM D41 Plywood
Colphene FR GR ASTM D41 structural concrete
i Refer to File Manufacturers orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
,NEMO ETC, LLC Evaluation Report 518010.06.09-R15
Certifcate ofAuthorrzot on t13�455 5`" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R17
Soprema Roof Underlayments Revision 15: 06/19/2019
Page 4 of 8
OMEMO I etc.
Underlayment Primer Substrates
Lastobond Shield, Lastobond Pro HT-N, RESiSTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Dens Deck Prime; SECUROCK
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Gypsum -Fiber Roof Board;
Sheet, Lastobond 195, Lastobond ECO, RESISTO 1.131236, (Optional) Elastocol Stick Zero ASTM D226, Type I or 11 felt;
Grip -Rite Eave & Valley Protector, RESISTO LB1244, Sopra-G; Modified Sopra-G
Lastobond Smooth Seal HT, Grip -Rite Smooth Sea{ HT or
Colphene FR GR
5.6.1 Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for
installation within 24 hours.
5.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix D, Testing Application Standard TAS 114, Appendix J or UL1897.
5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum
codified requirements. For installations under foam -on the systems (Lastobond TU HT only), base sheet shail be
attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein.
5.6.5 _Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012 (04-12) or FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure = -45.0 sf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer_ Elastocol Stick Zero
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
NEW ETC, LLC Evaluation Report 518010.06.09-R15
certifrcute ajAuthorizotion a32455 6- EDITION (2017) FBC NON-HV14Z EVALUATION FL2569-R17
Soprema Roof Underlayments Revision 15:06/19/2019
Page 5 of 8
ON EMO I etc.
#3 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered; thoroughly rolled using hand roller and/or weighted
roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -
laps.
Underlayment: Lastobond TU HT, self -adhered; thoroughly roiled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps,
94 Maximum Design Pressure = -150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#5 Maximum Desi n Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction_
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC
1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps
5.6.5.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tle systems carry a Maximum
Design Pressure of -45 ps€.
5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSAITRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professionai to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI ►ND1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip -Rite Eave & Valley
Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT shall not be left exposed for longer than 90-
days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
NEMD ETC, LLC Evaivadon Report S18010.06.09-R1S
Certifcate of Authorization #32455 6111 WiTION (2017) FBC NON-HVHZ EVALUATION FL2569-R17
Soprema Roof Underlayments Revision 1S: 06/19/2019
Page 6 of 8
S.8
ONEMOjetc.
Tile Slippage Limitations (TAS 103 per FRSA TRl April 2012 04-12 :
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
inI1MA;c Thpca clnnp limitations can only be exceeded by using battens during loading of the roof tiles_
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
&.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER (if applicable).
6-3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, Enviro5hield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO L81236, Grip -Rite Eave & Valley Protector, RESISTO LB1244
ar Colphene FR GR:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the requirements for A5TM D1.970 underlayment in FBC Table 1507.1.1 or
R905.1.1 forthe type of prepared roof covering to be installed, and Soprema published requirements.
6.3.2 Tile Applications Lastobond TU HT or Col hene FR GR onl :
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and Soprema
published requirements.
For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane,
fastening of the ASTM D226, Type II base sheet shall be in accordance with Soprema requirements, but not less than
that the densities set forth in FRSA/TR1 April 2012 (04-12), Table 1.
For foam -on tile applications (Lastobond TU HT only), reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012 t04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 3 herein, and Soprema published requirements for tile staging.
Evaluation Report 518010A6,0o-R15
MEMO ETC, LLC FL2569-R17
Certificate of Authorization 1l32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION
Soprema19
Page 7 Roof Underlayments Revision 15: 06ge 7 of
of 8
ONEMOletc.
As required by the Building Official ar Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the noted CAA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
Refer to Section 4 herein for product & production locations having met codified physical properties specifications.
UL, LLC—QUA9f25; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Evaluation Report S18610,06.€39-R15
NEW ETC, LLL M EDITION pirEVALUATION
FL2569-R17
Certificate of Authorization #32455 Soprema Roof lnderlayments Revision 15: 06/19/2019
Page 8 of 8
111512019
`+75 '. ,� 1. i�T � Ys•v� Yh. #a".�r i
_ ten.
BMS home
Log In _ User Registration .. Hot Topics
Product Approval
USrR: Ppblic user
Florida Building Code Onilne
Submit Surcharge Stats & Facts PilAcations Contact us 111 BCIS ste Map Unks Seardh
product Approval Menu > ProdJct or Anplicatinn Search > Acpli[atlon UE > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL10574-RIS
Revision
2017
i
Approved
1 V
'J��k-k �ZY-N�n
Owens Coming 0
One Owens Coming Parkway
Toledo, OH 43659
(740)404-7829
greg-k-eeter@owenscorning.com
Greg Keeler
greg.kc,E!Ier@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sa ncrant@owenscorn i g. cam
Roofing
Asphalt Shingles
6 .-?" - -t -I
Evaluation Report from a Florida Registered Architect or a Licensed Florida
ProfessionaE Engineer
valuation Report - HardcOpy Received
Florida Engineer or Architect Name who developed the Robert J.M_ Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC,
Quality Assurance Contract Expiration Date 04/20/2020
Validated 8y John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL10674 R15 COI 201g 01 COI NIEMINEN pdf
Standard
ASTM D1970
ASTM D3161
ASTM D3462
ASTM D7158
Year
2015
2016
2010
2011
https:llfloridabuilding.orgiprlpr app_dtl.aspx?param=WGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReg] CQSucR6ixEDL7figG32Q9MA%3d%3d 112
11/512019
Florida Building Code online
Product Approval Method
Method i Option D
Date Submitted 08/15/2019
Date Validated 08/]S/2019
Date Pending FBC Approval O8/21/2019
Date Approved 1Q/15/2019
Summa of Prodacks
FL rk- Model, Number or Name Description -
10674,1 Owens Corning Asphalt Roofing
Shingles and Starters
Limits of Use
Approved For use in HVHZ: No
Approved for use outside HVHZ: Yes
Empact Resistant: NJA
Design Pressure: N/A
Other: Refer to ER, Section 5.
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge shingles
Installation Instructions
FL10574 R15 II 2019 08 FINAL FR OC ASPHALT
SHINGLES FL10674-R15 ❑df
Verified By: Robert). M. Nierrilnen PE - 59166
Created by Independent Third Party: yas
Evaluation Reports
FL10674 R15 AE 2019 08 FINAL ER OC SPHALT
SHINGLES FL10674-R15pdf
Created by Independent Third Party: Yes
Contact Us ;: 2601 Blair Stone Road, Ta€ 1-as ee =t 33 99 Phone: 950�87;�874
The State of FOriCa is an AAIFC-0 employer. CcapyC-ght 2007-2013 5 t ur F orida.:: Prime Statement aalmtbll icy Statement :: Refund Statement
Under Florida law, email addresses are public records. 1f you do not want your a -mat€ address released in re-sponsa to a public -records request, do not send electrvOnic
mall to this entity, instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850-487.1395.'Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. mu6t provide the Department with an email address if they have one. The ema $s
Provided may be used for official communication with the licensee, However email addresses are public record. If you du not wish to supply a personal address, please
provide the Cepartfnent with an email address which can be made available to the public To determine if you are a licensee under Chapter 455. F.5„ please rJidc here .
Product Approval Accepts:
® tLtrct
Credit Card
Safe
https:fllloridabuilding.orgiprlpr app_dti.aspx?pararn=wGEVXQwtCgtBNbEY5Wo2boQT%2b6w7ahRegtCQ8ucrt6ixEDL76gG32Q9MA%3d%3d 212
MEMO I etc,
certificate of Authorization #32455
353 Christian Street, Unit #13
UN Oxford, CT 06478
ENGINEER EVALUATE (203) 262-9245
TEST CONSULT CERTIFY
s ,s.
Owens Corning One Owens Corning Parkway Evaluation Report 037940.02.12-R40
Toledo, OH 43659 FL10674-R15
(740) 404-7829 Date of issuance: 02/06/2012
Revision 10: 08/15/2019
SCOPE.
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume- The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). MEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTrsEWNT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEcriON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen, P.E. :s ; Tr The facsimile seal appearing was authorized by Robert
';�� '' p":'s�': •;1 Florida Registration No. 59165, Florida OCA ANE7983
Nieminen, P.E. on 08/15/2029. This does not serve as an
elettronically signed document
CERT1FiCATIaN OF INDEPENDENCE.-
1. NEMO] etc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO Ietc. is not owned. operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor wili acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financiai interest in any other entity invoived in the approv@i process of the
product.
5. This is a building code evaluation- Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record far any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02018, NEMO ETC, LLC
ROOFING SYSTEMS EVALUATION;
DEMO I etc,
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code and Florida
Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
StAkiARDS:'%.
Section
Property
Standard
Year
1507.2.4, 13905.2.3
Physical Properties
ASTM D1970
2015
1507.2.5, R905.2-4
Physical Properties
ASTM D3462
2010
1507-2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2-7.1, R905.2.6.1
Wind Resistance
ASTM D71S8
2011
En itv
Examination
Reference
Date
Owens Coming
Declaration
Equivalency Declaration
09/06/2019
PRI (TST5878)
ASTM D1970
OCF-382-02-01
10/24/2027
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
OECA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
U L LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL Ll_C (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
4.1. ACCESSORY STARTERS:
4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets
ASTM D3462.
4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SSS modified bitumen starter strip,
nominal 7.2-inch wide x 33-ft 4-inch long roll, for use with asphalt shingles. Meets ASTM D1970.
4.2 ASPHALT SHINGLES:
4.2.1 Classic" and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles- Meets ASTM D3462,
4.2.2 Berkshire' are fiberglass reinforced, 4-tab asphalt roof shingles. Meets ASTM 03462.
4.2.3 Duration, TruDefinition' Duration, Duration' Premium Cool, TruDefinition' Duration- Designer Color Collection,
TruDefinition` Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof
shingles. Meets ASTM D3462.
4.3 HIP & RIDGE SHINGLES:
4.3.1 Berkshire` Hip & Ridge Shingles with Sealant, DuraMdge° Hip & Ridge Shingles with Sealant, ProEdge9 Hip & Ridge
Shingles and WeatherGuard£ HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
Meets ASTM D3462.
t4EI00 ETC, LLC Evaluation Report 037940.02.12-R10
Cerpcote o}Authorization,Y32455 6' EDITION (2017) FBC NC)N-HVHZ EVALUATION FL10574-R15
Owens Corning Asphalt Roof shingies Revision 10: OBJ15/2019
Page 2 of 20
NDEMO I etc.
5.1 This is a building code evaluation. )Neither NEMO ETC, LLC nor Robert Nieminen, P.E_ are, in any way, the Designer
of Record for any project on which this Evaluation Report or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials directory for
fire ratings of this product.
5.44 Wind Classification,
5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2,7.1
and R905,2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones
up to Veld = 150 mph (Vr,i, = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 Starter Strip Shingle, Starter Strip Pius and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip
& ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vasd = 150 mph (Vui = 194 mph). Refer to
Section 6 for installation requirements to meet this wind rating.
5.4.3 Referto Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 611320-3.
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements_
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.23.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5_ Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, suhiect to the
limitation5 set forth in FBC 5ection 1511 or R908 and published installation instructions.
6.2 AccESsORYSTARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SIRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Felt urrderlapn:ent
Self..dhu!d
WearhmLo k°
uar!lriaS'mepr
a!vl Pdpc
frnm eve
::ly// pOSltlppPd aipnp ldYC
$tdf:P: SX4 lcAule overh:Aa eater and nka
Figure 1: Minimum Na)iing, Starter strip
ix6untlz{eymlet
pars Sdbaeherd
�efhuLxiT
tlesls,ment
dyr -
a
l7e�a la��
Z'.3" Iran rvn
FsuaOS �S�zeeeS�Rx _
vitir6'ranarYd -
SUnv Strp
Srlere6ag adaexi.
pfal"eanM a}aig erie
Ft sa.ahaaa: nraxr� aaYr•. IN -3t.•'
Figure Z: Minimum Nailing, Starter Strip Pigs
NEMO ETC, LLC
Evaluation Report 037940.02.12-R10
CerbficateofAurhorizationr32455 G' EDITION (2017) FBC NON-HVHZ EVALUATIOhi
FLI8874-1333
Owens Coming Asphalt Roof Shingles Revision 10- 08/15/2019
Page 3 of I0
NNEMO I etc.
6,2.2 Installation of Starter Shingle Roll shall comply with the C)wens Corning current published instructions.
Drip edge
i
D86
Self-sealing adhesive
positioned along eaves
Figure 8: Starter Shingle Roll
Underlayment
edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
6.3 ASPHALT SHINGLES:
6.3.1 installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
Y Berkshire' shingles require minimum five (5) nails per shingle.
r WeatherGuard` HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Classic"' & Supreme:
Normal Mamard or Area pare
Wind Areas High Wind desysnas y
Area Para vientos normales Areas vienios frterres
5" Ezpasure
�zposiciSr
Figure 4: Minimum Nailing, Classic & Supreme
(Standard Size)
Normal Mansard or Area pare
Wind Areas High Wind dasvanes y
Aran pars vienios normaies Areas vienios fuartas
r��z „1�iA1 ��zt � � �r 2 {BIB I'x" �•-;
5 5/8° Exposure
E'xposiciort
Figure S: Minimum Nailing, Classic & Supreme
(Metric Size)
MEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certljkate of Audwizorion#32455 6„ EDMON 120171 FBC NON-HVHz EVALUATION FL10674-1115
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 4 of 10
6.3.1.2 Berkshire®:
&aianr strip
L-11ka A-gPmw'r
NNEMO I etc.
sealarit drip
Laiffa&sewl '
t" J
Figure 6: 5-Nail Pattern, Berkshire
Figure 7: 6-Nail Pattern, Berkshire
SeaFant strip
La &ra da �irodar
1"
%V1Sb�•
2"
Asphah ra„rmg msnt
Cerrtato de rFrhodeacta,7o
Figure 8: Mansard or Steep slope Pattern, Berkshire
NEMO ETC, LLC
Cerrrftate ofRufharization #32455 6' EDITION (2017) F$C NON-HVHZ EVALUATION Evatuation Report 037940.02.12-Ri0
FL10674-R1s
Owens Corning Asphalt Roof Shingles Revision 10; 08/15/2019
Page 5 of 10
6.3.1.3
NNEMOILAC.
Duration° TruDeftnition" Duration DurationO Premium Coot & TruDeffnition' Duration' Desjigner Color Collection-
5-51a"
4-Nail Fastening Pattern
SureNaM Fastening area width
Nail. 7ypicat
1 1- 12' _i F 12"
Figure 9: Standard 4-Nail Pattern, Duration
6-Nail Fastening Pattern
SureNaH& fascemng area width
Nau, Typlcat
1" 12"
Y7wertc Corne�g5vs.'h;� A �staneEur
S-1l8" 5-5I8"
exy�-.me
Figure 19: 6-Nail Pattern, Duration
Fastening for Slopes Greater Than 21:12
I
f!� SureNaii,D Tastersing area tridth
! F Nail, Typical
t2"�
a nch-scon�a
s•vs^ sra"
FL
• 2„
Four V Spots of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern, Duration
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certif;wlsojAutherization #32455 6'" EDITION t2017j FSC NON-HVHZ EVALUAPON FL10674-R15
Owens Cornfng Asphalt Roof Shingles Revision 10. OS/15/2019
Page 6 of 10
6.3.1.4 TruDefinition'Oakrid e® Qakrid eG:
4 Nail warn
Fstlatcvna con 4 claws
-------------
55fa" ExposureNails 5 5/9" Exposure
Exposic96a de 55iBpu'g. Cfams Fxpusie6n de 55J8pufg
Figure 12: Standard 4-Nail Pattern, Oakridge
5 Nair Pattem
Esguema con 6 clavos
r t.:
Imo- ,L° •�i �-- tr —?�
55/$" Erposuro I
CiaVQ YaS 5 5iB" EEpasure
lweposid6n de 5516pufu ExposiG6n de 5518 puig.
Figure 13: 6-Nail Pattern, Oakridge
I gaulc — eriafi�aiu ui ]LCC}f-Jiupe Nariern, Ej2mritlge
�NNEMOjetr-
NEMO ETC, LLC Evaluation Report 037940.02.12-Rlfl
CertiticateofAuthorizariou#32455 6'H EDITION (2017) FSC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 7 of 10
6.3.1.5 WeatF erGuard® H€'-
5 5is E.9wire
ExunsdSa dr 5 58 pu:}
5 5V En =4
UV0*in & 5 518 WL7.
Figure 15. &Nail Pattern, WeatherGuard HP
6 Nail Pattern
Espema can 6 clayns Nai3 6 11&' from bot'ur m
Of shiltmla
5 58" fx osute 6 Fasteners clave a 6 318 pping, de la
Exposiai6nde 5 5f8 ping. 6 sujetadores parse inferior de la tea
Frrur i' Spots of .4sphah P&JIf Cement
cuatfa puntvs de cemarrto de [echo de astfto de 1 puk ada
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
NNEMO I etc.
6.4 HIP & RIDGE SHINGLES:
6.4.1 installation of asphalt shingles shall comply with the Owens Corning current published instructions.
> Berkshire' Hip and Ridge Shingles with Sealant and DuraRidge° Hip & Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
WeatherGuard` HP Hip and Ridge Shingles and Pro Edge° Hip & Ridge Shingles require minimum four (4)
nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
NEMO ETC, LtC Evaluation Report 037940.02.12-RID
CertiTcateofAvthntLatian 932455 6'i EDITION (20.17) FSC 1VON-HVN2 EVALUATION F110674-RIS
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 8 of 10
6.4.1.1 Berkshire@ Hinz itid a with Sealant and DuraRiri a®I (i & Rid a Shingles with Sealant: NEAAO I etc.
Fig. A �_— PtevailingWind Direction Fig, 13
Dit '6n del viento predominate Top View
1 I Vista superior
� f � 7nf�
$I/ � Nall
Nai is a Clavo
Claws • Owens CQming SureN4- •
m
y— I4-9Exposure " I M
fErp kidill dos grlg U i c
e I a
\ .n
Figure 17: Isometric View, Berkshire and DuraRidge Figure 18: Plan View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard o HP jip & Rid a Shin ies:
Fig. A
- I I
i I
S,
I
I I I ]
I I
t
�Xj�O5Lf2
c
-I ... .__„, v'w, wearneruuard HP Hip & Ridge
r;gure ZQ; Plan View, WeatherGuard HP Hip & Ridge
NEMO ETC, LLC
CertifrcoteafAuthor.zQe,,.#32455 5'11 EDITIOPI (2017) FBC NGN-HVHZ EVALUATION EValuatipn Repor, 037940.02.12-R1p
Owens Corning Asphalt Roof Shingles =L10674-R15
Revision 10: 08/15/2019
Page 9 of 10
6.4.1.3 ProEdge®Hip & Ridge Shingles:
Prevailing
Wind Direction Sealant Strip
6' Exposure
Faster. 711r'
Cover Exposed
Fasteners with
Roof Cement
Figure 21:1sometric View, ProEdge
*NEA,AO I etc.
Standard
Fas[[ening
Pattern
12' Sealant
f
7'1? 6" Exposure
1
Figure 22, Plan View, ProEdge
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with ore of the required classifications detailed in FBC Table
1507.2.7.1 / R905.2.6.1.
As required by the Building Dfficial or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3
QA requirements.
PRI Construction Materials Technologies, LLC—aUA9j10; J§131 621-5777, bwiison@pricmt.com
- END OF EVALUA71ON REPORT -
MEMO ETC, Li_C
Evaluation Report 037940.02.12-RYO
CertificareOfAuthu iza6onR32455 6„' EDIT ON (ZO17) FRC NON-HV#47 EVALUATION
FLID ii7w-Rl5
Owens Corning Asphalt Roof Shingles Revision 10; 08/15/2019
Page 10 of 10