HomeMy WebLinkAboutConstruction Plans7804 McClintock Way Port St. Lucie, FL This structure has been designed in accordance with the requirements of the 2017 Florida Building Code, Sixth Edition - Residential, Chapter 3, Section R301.2.1. The following wind load requirements, in accordance with 2017 Florida Building Code, Sixth Edition - Building, Chapter 16, Structural Design, Section 1609 and ASCE 7-10 were employed in the design of the structure: Ultimate Design Wind Speed (Vuic): 160 MPH (3-Second Gust) Nominal Design Wind Speed (V.d): 124 MPH (3-Second Gust) Risk Category: II Wind Exposure Category: B Applicable Internal Pressure Coefficient: +/- 0.18 Design Pressure for Exterior Components & Cladding: • Walls = +23.5/-28.0 PSF • Roof= +11.2/-32.0 PSF Davis & Cleaton Engineering, Inc. 101 Sunnytown Road Suite # 109 Casselberry, FL 32707 FL P.E. License 9 35816 7804 McClintock Way Port St. Lucie, FL WIND LOADS ON EXTERIOR OPENINGS OPENING SIZE TOTAL TOTAL POSITIVE NEGATIVE LENGTH OF LOAD PER LIN. AREA LOAD WIND LOAD WIND LOAD BUCK ATTACHMENT FT. OF BU. (Ft.2) (Lbs.) (PSF) (PSF) (In.) (LB. per FT.) Window T-0"xT-0" 9.0 333 27.7 37.0 108.00 37 Door 16'4"xT-0" 112.0 3,136 23.5 28.0 360.00 105 Door 31-011x61-8" 20.0 680 26.4 34.0 196.08 42 1.) For exterior windows, use 1x4 P.T. buck on jambs and head. 2.) For exterior doors, use 2x4 (Min.) P.T. buck on jambs and head. 3.) For garage door use minimum 2x6 P.T. buck for jambs and required spring pads. 4.) Provide enough fasteners of type used to equal or exceed stated loads on table. Fasteners are required no closer than 2" or more than 4" from ends and spaced equal in distance along balance of buck. Minimum fasteners for top buck is 2. " Minimum fasteners for side buck is 3. Approved Fasteners: 3/16 Tapcon with 1 %" penetration = 230 lb. of holding power. ''/4" Tapcon with 2" penetration = 380 lb. of holding power. See manufacturers specification for required fasteners to attach garage door, entry doors, patio doors and windows to building. Note: Garage door "bucks" shall be attached to studs with 318"x4" lag bolts. Spaced each 24" o.c. with minimum of 3 bolts. Davis & Cleaton Engineering, Inc. 101 Sunnytown Road, Suite 109 Casselberry, FL 32707 Ph.# 407-539-2353 Lic.# 35816 G' I I I I I I I I I 31' L_________________ 24' REAR ELEVATION (4TH WALL) 3/16" = V 15' T 10, I I I I I I I 1 I I 1 I I I L 4of6 a Ou u I ID0 m C I � C I I I - � I C C } I I 0 I I I ? I I n I I LL I I � I I C I I I I I I C I I I I I I I I M I I 5 of 6 160 0 GA L_______ I _______ ACCES5 3030 WIN 4 of 8 I I I I. I I DOTTER 51 1 ' DETAIL 5 of 6 1 I 1 9" X I- I /2" RECESS I I IN CONCRETE 51AI3 I I Q GARAGE DOOR. I I I I I I I M I DOO 5 of 6 I I — I 2' 1 G' 2' 20' FLOOR PLAN 3/16" = 1' FRONT ELEVATION 3116" = 1' GENERAL NOTES IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH OF HIS SUBCONTRACTORS TO REVIEW ALL DRAWINGS, REVISIONS TO DRAWINGS, ETC. TO ASSURE COORDINATION OF ALL WORK AFFECTING EACH TRADE FAILURE TO REVIEW ALL CONTRACT DOCUMENTS FOR APPLICABLE ITEMS OF WORK SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING ALL WORK REQUIRED. 1. ALL TRADES MUST PERFORM TO CURRENT EXISTING CODES AND ORDINANCES APPLICABLE TO THIS PROJECT. 2. CONTRACTORS TO VERIFY ALL DIMENSIONS AND CONDITIONS. 3. ALL MATERIAL TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. 4. ELECTRICAL PER LICENSED CONTRACTOR TO LOCAL AND NATIONAL STANDARDS.. S. CONTRACTOR IS RESPONSIBLE FOR THE PROPER WATERPROOFING, FLASHING AND SEALING OF THE ROOF AND STRUCTURE, EXISTING AND NEW. IN AND BEYOND THE SCOPE OF THESE DRAWINGS. 3' 24' I O.-G. �,�� 1 4 F® E CC1Mp�lp'NG G®p 13Cle CCUta' ST.1- SpCG FILE COPY ti _C O C N co co O N CD o O 2 IT N C IL (o O 0 U mo o > v U c O 0 U rn 7F 6 DATE: 03-27-20 T 13'-4" lk 3/16" = 1' :CTION B-B 3/16" = 1' s 5 of6 5HINGLE5 TO BE APPLIED DIRECTLY TO PANELS WITH N8 X 3/4" GALVANIZED WAFER HEAD DRILL ----- --------- --- ----- POINT SCREWS. - ---- ----- ----- ------------ U5E MANUFACTURFK5 RECOMMENDED NAILING PATTERN _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - - - - IT - - - n - - - - - - - - - - - - - - - - _ _ _ _ _ _ _ _ - _IT _ - _ _ Ti- _ _ _ _ _ - _ - - - - - . EXISTING MOBILE sots K HOME VINYL 51DING TO BE 4 of 6 . I APPU ED DIRECTLY TO PANELS WITH #8 ALVANIZED 5.M.5. II i li SPACING PER F7MA I UFACTURER SPEC5. LEFT ELEVATION 3/16" = 1' RIGHT ELEVATION 3/16" = 1' I O' K II "3� I 4 of 6 5 of6 0 c Nco O o O M L6 N O LL to o Lo O P1 c O O U t w cm N > LO m CD O Y '6 p LLLL Q J C d 61 N U 7 ca Cc O � O O co r ILL EXISTING , MOBILE • HOME.. _I lz CO R fl L JF 6 DATE: 03-27-20 FILE D � z rn v Z z (� rn r m Q1 11 �( O2 M'� n z rn z O 6 70 O W �z rn m r = - -n N D � Z- .-.-.:.- .- ::.-.-.:: m rn Gz1 A X ? n O O T I1 O 0 D 'D O ZO r-� U)m w m '• •I T N_ II � J I• � I' Z I• I. I _ O I L D I rn I D �• �rn va�.va _•v a �._. �_.0 _va _. av_.va a�.•ua � r yrn Oz N p rnZ I � - z z 7� A A rn O m' 3 PAvI5 & Cleaton Ergwert,q U. #35816 Garage Addition Shull Construction of Orlando, Inc. 03 101 5unn4town goad, `� tc 109 Savanna Lot # 7512 Oviedo, FI 32762 - Cawberr% FL 52707 N 7804 McClintock Way (407) 365-4078 v - ieck„o.:c4o-ii�3v-��e r„s;cgOn,x��•r� o °' _ �'•��� Port St. Lucie, FL 34952 CRC 052310 ROGER SHULL CRC 05 BREAK METAL RIDGE CAP �(I) # 12 X 4" S.M.S. WITH 3" X c I .5"d FENDER WASHER I VI NG RECEIVING CHANNEL. @ G" ON CENTER. ATTACH TO BEAMS 0. 1 25"t 0. 1 25"t El (1) #8 X 1 /2" 5.M.5. PRIOR TO SETTING c m N w co @ 15" ON CENTER. c INTO WALL. a N m o N 0 0 0 0 4'X 4" X 0. 125" HOLLOW 4"X4"X0.125" c u.In CD 3" COMPOSITE PANEL. p p C/CHAN TO 2X9 BEAM KNEE BRACE. HOLLOW KNEE BRACE. a U o REQUIRES (9) # 10 X 3/4' 0 a o , B 0 o S.M.S. PER BEAM. 0 4" i.d. RECEIVING CHANNEL ° 4" I.d. RECEIVING CHANNEL a > v L) 0 o REM/CHAN PANEL WALL (4) # 12 X 3/4" S.M.S. (4) # 12 X 3/4" 5.M.5. O (2) 2" X 9" RIDGE BEAMS o REQUIRES (9) # 10 X 4"' (EACH SIDE OF REC/CHAN) (EACH 51DE OF REC/CHAN) U INTERNALLY FASTENED 0 a 5.M.5. PER BEAM. ° (2) I/W X 3-3/4" THRU ° (4) I/4"0 WOOD LAGS L WITH (2) #1 O X 3/4" 5.M.5. ° 0 BOTTOM REGCHAN U @ 12" ON CENTER. (4) # 12 X 3/4" INTO BEAM BOLTS WITH 1-1/2" THRU REC/CHAN WITH 0 ° ° $ (4) # 10 X 4" THRU WALL. FENDER WASHER, LOCK 2-1 /2" (MIN.) THREAD (1) # 12 X 3/4" 5.M.5. WASHER AND NUT. PENETRATION INTO @ 12" ON CENTER. *NOTE: # 10 X 4" 5.M.5. PROTRUDE THRU BOTH SIDES OF P/C. SOLID WOOD. 'SEAL ALL EXPOSED SCREWS. (TOPE BOTTOM OF BEAM) *OPTION: #1 2 X 3/4" 5.M.5. INSTALLED ON EACH SIDE OF R/C. DBL. CONT. 2XG #2 5.Y.P. A PANEL ROOF TO RIDGE BEAM B RIDGE BEAM 5ET INTO WALL PANEL C 4X4 KNEE BRACE TO WALL PANEL DETAIL D 4X4 KNEE BRACE TO GARAGE HEADER DETAIL rn N m (1) # I O X 4" 5.M.5. WITH DOUBLE 3" X 0.055" ti a0 (2) 2" X 9" X 0.072" X 0.224" 5.M.B. (I) # O X 4" S.M.S. WITH 1 0 FENDER WASHER I .5" 0 FENDER WASHER RECEIVING CHANNELS 'o 0 lei. .5" @ 1 2" ON CENTER. @ G" ON CENTER. TURNED @ 90° AND JOINED WITH Q � c y (I) # I O X 4" S.M.S. @ 8" O.C. o 0 4" I.d. X 0.090" RECEIVING CHANNEL c J WITH (4) #I 2 S.M.S. INTO WEB OF co EACH 2X9 AND (4) # 12 5.M.5. INTO 3" COMPOSITE ROOF PANEL. C7 > N 4X4 EACH SIDE OF RIDGE BEAM. P, O T3" COMPOSITE ROOF PANEL. p, REQUIRES (I) # I 0 X REQUIRES (1) # I O X 3/4" E). @ 8" O.C. (EACH SIDE). @ 8" O.C. (EACH SIDE). o a a 3" X 0.055" PRE SLOPED (I) # 10 X 3/4" 5.M.S. @ 8" O.C. 3" X OA55' RECEIVING CHANNEL. (EACH SIDE OF REC/ CHANNEL) # 12 X 3/4" S.M.S. RECEIVING CHANNEL. 3" COMPOSITE WALL PANEL. 3" COMPOSITE WALL PANELS. m 3" COMPOSITE WALL PANEL. 4" X 4" X 0. 1 25"t 65 ��s b :q E 4X4 KNEE BRACE TO RIDGE BEAM DETAIL F PANEL ROOF TO PANEL WALL (GABLED END) G PANEL ROOF TO PANEL WALL Fi WALL PANEL TO WALL PANEL (CORNERS) A _ #8 X 1- I /2" COMMON DOUBLE 3" X 0.055" e DOUBLE 3" X 0.055" RECEIVING CHANNELS @ 12" O.C. RECEIVING CHANNELS (1) # 10 S.M.S. X 3/4" @ 6" O.C. TURNED @ 90° AND JOINED WITH TURNED @ 90° AND JOINED WITH to b (1)#IOX4"5.M.5.@8"O.C. (1)#10X4"5.M.5.@8"O.C. FLASHING E SEALANT WITH 3" COMPOSITE WALL PANEL (1) #10 X 1/2" 5.M.5. @ 12" O.C. INTO FASCIA AND ROOF PANEL. FLANGE MOUNT WINDOW OPENINGS ARE ' Una WINDOW UNIT. ATTACH FRAMED ON ALL 51 DES CONTINUOUS 2X4 #2 S.Y.P. , THRU 3" X 0.055" WITH 3" X 0.055" WITH (2) # 10 X 2" 5.M.5. RECEIVING CHANNEL —RECEIVING CHANNEL. @ 12" ON CENTER. / FLASHING E SEALANT WITH WITH (1) # 10 X 3/4" TTACH TO WALL PANEL -. CONTINUOU53"X0.055" N } (I)#IOXI/2"S.M.S.@12"O.C. S.M.S.@6"O.C. WITH (I)#IOX3/4" RECEIVING CHANNEL. o 5.M.5. @ G" O.C. 0 PREHUNG DOOR UNIT. FASTEN U 5 (1) # 10 X 4" 5.M.5. @ 8" O.C. 00 # 10 X 4" 5.M.5. @ 8" O.C. PER MANUFACTURERS SPECS. THRU ROOF PANEL AND BOTH THRU WALL PANEL AND BOTH WINDOW UNIT I JAMB SIDES OF RECEIVING CHANNEL. SIDES OF RECEIVING CHANNEL. THRESHOLD _ Ir OF G 111 ROOF PANEL TO WALL PANEL (UNDER SAVE) ROOF PANEL TO WALL PANEL (NO SAVE) K WINDOW FRAMING TO WALL PANEL DETAIL L DOOR FRAMING TO WALL PANEL DETAIL DATE: 03-27-20 � FILE COPY (I)#1OX3/4' 5.M.5. @ 6' O.C. DEL. CONT. 2XG #2 5.Y.P. (3) 3/8" THRU BOLTS DBL. CONT. 2X 10 #2 S.Y.P. c GLUED TOGETHER AND WITH WASHERS AND NUTS 2' X 2" X 0. 1 25' X 10" ANGLE GLUED TO PANEL WALL. ' THRU ROOF AND THRU m cv WITH (1) # 10 X 4" 5.M.5. " °p ' 2" X 2" X 0. 125" ANGLE. Q 3/8" 0 WOOD LAGS co co M CD , @ 1 2" O.C. (STAGGERED) d ° WITH 2-1/2" MIN. THREAD v p 04 (2) 1/4" 0 WOOD LAGS WITH PENETRATION INTO SOLID 0 Cco In •` 1-1/2"WASHERS AND 2-1/2" i y i �� °p m® WOOD. '0o (MIN.) THREAD PENETRATION t i it GARAGE DOOR ° O ® y- 0 O INTO 5OUD WOOD. (2) ROWS ' WOOD FRAMING. ® '. (4) 3!8" 0 WEDGE ANCHORS ••'. O @ 1 2" O.C. (STAGGERED) �1Y CONNECT VERTICAL TO Q 318" m WOOD LAGS ° �� WITH 3" MIN. EMBEDMENT a' '.' U HORIZONTAL MEMBERS U51NG WITH 2-1/2" MIN. THREAD .< ,'.' INTO SOLID CONCRETE. _ CONTINUOUS 6" X 0.024" 51MPSON LSTA 12 (iYP.) PENETRATION INTO SCUD , NOTE: 13REAKFOPM REGCHANNEL. WITH I Od COMMON WIRE NAILS. (FILL ALL HOLES) C) WOOD. a: . ". a '•.' - .• 2 X 4 #2 5.Y.F. VERTICALS ° '• ' ' ' '�d U)„ GARAGE DOOR UNIT. FASTEN ®® 2" X 2" X O. 125" X 10" ANGLE •'• ' (I) 3/8" 0 WOOD LAG AND - ° PER MANUFACTURERS SPEC.: DEL. CONT. 2X 1 O #2 S.Y.P. (I) 3/8" 0 WEDGE ANCHOR GLUED TOGETHER AND DBL. CONT. 2X 10 #2 S.Y.P. THRU 2" X 2" X 0. 1 25' X 4" ANGLE GLUED TO PANEL WALL. MGARAGE DOOR FRAMING TO WALL PANEL DETAIL N GARAGE DOOR WOOD FRAME SUPPORTS Q WOOD FRAME CONNECTION AT ROOF P WOOD FRAME CONNECTION AT FLOOR rn a ROOF FINISH BY OTHERS. p n Y # 10 X 3/4" 5.M.5. @ 1 2" ON CENTER (EACH SIDE). oLL 4" THICKENED EDGE CONCRETE SLAB WITH 3000 P.5.1. CONCRETE " COMPOSITE WALL PANEL. Q J dl •� WITH GXG, I OX 10 W.W. MESH CONTINUOUS 0.055" EXTRUDED ALUMINUM FASCIA. N CaO OVER 6 MIL. VISQUEEN VAPOR 3" X 0.055" CONTINUOUS I/4" BEAD OF EIASTOMERIC SEALANT. c J BARRIER OVER COMPACTED SAND RECEIVING CHANNEL. 1 /8" 0 WEEP HOLES IN BA5E OF FASCIA @ 48" ON CENTER. m m O > d' to FILL OVER TREATED SOIL. REQUIRES (I) # I 0 X 3/4° @ 8" O.C. (EACH SIDE). U) 0 o 4" CONTINUOUS 1/4" BEAD OF COMPOSITE PANEL ROOF DECK SEALED WEATHERTIGHT IL IASTOMERIC SEALANT. @ PANEL JOINTS AND EDGE CHANNELS. STANDARD ASPHALT COMPOSITION SHINGLES. ' '.`.• er .. . ' I/2" 0 X 8" STEEL J-BOLT 0" STARTER COURSE FASTENED 2" OFF ROOF EDGE PER �! 8"Y9 ' °' .,'., / / i \\ \\\' \ '. ;... \/\\�� (2) CONTINUOUS #5 PE15ARS :•' CONCRETE ANCHOR WITH . a .. ' �.: "a•, NUT AND WASHER �. ., ::x�'""'"' '� e..'.`':. SHINGLE MANUFACTURER'S SPACING REQUIREMENTS. \ \ \\ WITH 3" MINIMUM CONCRETE ^. @ 6 ON CENTER. '*'e• ^; - , • ti�;.� t" #8 GALVANIZED, STAINLESS STEEL OR COATED LOW `O CO 3 G"13 //COVERAGE ON ALL SIDES. �\\ \\ 'a!'. % s < . .-.:'+�PROFILE HEAD METAL SCREWS PER MANUFACTURERS SPACING REQUIREMENTS. 3/5" Qf HEAD (MIN.). zc\ I/8" 0 WEEP HOLES IN BASE @ 48" O.C. NOTE: 3:12 MINIMUM ROOF SLOPE REQUIRED. Q CONTINUOUS FOOTING @ SLAB EDGE R WALL PANEL TO CONCRETE SLAB $ PANEL ROOF EDGE FRAMING AND REQUIRED SHINGLING DETAIL r r e # 10 X 3/4" 5. M.S. ROLLED FORM LOCK SPACING PER AND SEALANT RESEVOIR o e e MANUFACTURER'S RECOMMENDATION. NOTE: DO NOT�'�,�'''�...,,+ . INSTALL SCREWS TIGHT TO PANEL. ' ALLOW SPACE FOR N THERMAL EXPAN51ON w I o OF VINYL SIDING. O e o 5 a COMPOSITE ROOF PANEL SYSTEM U 3" X 48" X 0.024" THICK ALUMINUM lHE J J 3105 H- 14 OR H-25 ALUMINUM ALLOY VINYL SIDING MIN. #2 DENSITY E.P.5. FOAM CORE 5 (=A (R-4 PER INCH OF THICKNESS) ix OF 6 - Lu 0 T VINYL SIDING TO COMP051TE WALL PANEL u ALL ROOF AND WALL PANELS U.N.O. �/ �/ DATE:03-27-20 0 sm COP Product Manuf FL# Garage door Overhead door FL14170-118 Shingles Owens Corning FL16638-112 Wall StructalI FL10778-114 Outswing door Jeld-Wen FL13540-115 Si ngle hu ng wi ndows Ply Gem FL14039-113 Vinyl siding KPBldg Prod FL12201-114 Structural roof Pro Fab FL2291-RIO ALL PRODUCT APPROVAL DATA IS FOR INFORMATION ONLY (�Mp'TI0N FOR X01FO ` Electrical Legend = Wall Mounted Incandescent # = Recessed Can # = 51ncgle Pole e = GFI Duplex Outlet m = Exhaust Fan #w = Recessed Can - Vapor Proof = Flourescent Strip (24" - 30 - 48") = Duplex Outlet = Quad Outlet = Pre -Wired for Fan '3068 DOORS ARE EXISTING ci \AND WILL REMAIN. a V W N O m O r-` O N O 0 M IT cl) N II STEPS C LL L O IT O O C.) CD O II CO) O 0 I I I — t I I I , I � , N ca M CO cl) Y J / D LL / �O Q j C / ca Cc / O O a -------------- ------- - - - --- -� ELECTRICAL PLAN 3/16" = 1' "FOR LAYOUT ONLY" ELECTRICAL SERVICE TO BE DETERMINED BY A LICENSED FLORIDA ELECTRICIAN. PANEL LOCATION TO BE DETERMINED BY BUILDER & ELECTRICIAN. IZ 03 .5 M r e .7) A v cis_ = m fl m ur g DATE: 03-27-20 1911 F 9 .!. Dpv