HomeMy WebLinkAboutProduct Approval - underlayment 5/712020 Florida Building Code Online
- a _ u
=°i.4t.11 Y �I1°•flue a .ft l_.Y. � I {
BCIS Home Log In i User RegistrationPr} Hot Topics Submit Surcharge ' Stats&Facts f Publications f Contact Us �• BCIS Site Map f Links ( Search
f-forici�
S` t )Product Approval
i USER:Public User
Product Approval Menu>Product or Appl radon earth>6pplication List>Application'Detail
l - ¢ FL# FL5259-R29
L` { Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1330 Ext 242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach,FL 33442
(866)802-8017
uspolyglasstechnicai@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach,FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underlayrnents
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By John W. Knezevich, PE
V Validation Checklist-Hardcopy Received
Certificate of Independence FI 52 9 R29 COI 2019 01 COI NIEMINEN j2,i_f
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2009
httpsJ/floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01ipmaCfgJXCANGg3CNQhK30Sg%3d%3d 112
51712020 Florida Building Code Online
FM 4474 2011
FRSA/TRI.April 2012 2012
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method I Option I)
Date Submitted 10115/2019
Date Validated 19/16/2019
Date Pending FBC Approval 10/20/2019
Date Approved 12/10/2019
Summary of Products
I
FL# Model,Number or Name Description
5259.1 Polyglass Roof Roofing underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL5259 R29 11 2019 10 FINAL -ER, POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside HVHZ.,Yes R 29.pliff
Impact Resistant:N/A Verified By:Robert Nierninen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this Evalu ation Reports
application relates to one particular F 5259 R29 AE 2019 10 FINAL ER POLYGLASS UN ERLAYMENTS FL5259-
underlayment system (over concrete deck)for R29.p_df
use under foam-on the systems(where the Created by Independent Third Party:Yes
underlayment forms part of the load-path).
Refer to ER Section 5.6.1 for other systems,
other deck types and associated maximum
design pressures.2.)Refer to ER Section 5 for
other limits of use.
Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399 Phone:856-487-1824
The State of Florida is an AA/EEO employer,Copyright 2007-2013 State of Florida.::Priv KVajAjeLmen
__A::Accesslbihty statement::Refund Statement
Under Florida law,email addresses are public records.If you do not Want your e-mail address released lin response to a public-records request,do not send ehictronic
mail to this entity.Instead,contact the office,by phdrie-or by traditional mall..Ifyou have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(l),
Florida Statutes,effective October 1,2012,licensees licensed under-Ch' r
under-Chapter 455,F.S.FS.must provide'the Department with a�_e �all address If they have one.The-emails
provided may be used for official communication with the licensee.However email addresses are public record.IF you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 4515,KS,please dick here
Product Approval Accepts:
"l- CW-1; RR M
Credit Card
Safe
https:/Iflbridabuilding.org/pr/pr_app_otl.asox?param=wGEVXawtDqvbSqAaZp3Crk2vS°/a2feqOlipmaCfqJXCANGg3CNQhK8OSg%3d%36 2/2
`
^
ohm'EMO VK
etc.
oertificotpofAuthorizatioo#32455
353Christian Street, Unit#13
Oxford, CT0G470
(2O3) 262-9245,
ENGINEER EVALUATE TEST CONSULT CERTIFY
Polyglass USA,Inc. Evaluation Report P12060.02.09-R2r
1111 West Newport Center Drive FL5259-1129
Deerfield Beach,FL 33442 Date of Issuance:02/24/2009
(954)233-1230 Revision 25:10/14/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6m Edition(2017)Florida Building Code sections noted herein.
DEson|rnom: Polyg|assRoof Und` r\aymentm
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
Cnm` mucoCoMpLmmcc: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
OveUtyAssurancedocumen1at|onchanges, nrprovisionsoftheCodethatre|atetntheproductchange. Acceptance ofthis
Evaluation Report by the named client Constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production fad|ity |ocadon(s). N2[NOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
AovcR0scnxEmr: The Evaluation Report number preceded by the words "NEK4D|et;. Evaluated" may be displayed in
advertising literature. !fanypurt|onoftheEvaivadonReport|sdisp|ayed,theh|tshaUbedoneinitsentinety.
;wspccT|oN� �
Upnnneque� acopyofthisendreEva|untipnReportsha\| 6epnovidedtotheuserbythemanufooturerorits
distributors and shall beavailable for inspection atthe job site at the request ofthe Building Official.
This Evaluation Report consists ofpages 1through 1G.
Prepared by:
Robert]'K4.N|em|nen,P'E.
Rocido8egi5trobonNo.59266,Florida DCA ANE1983 ���:.�° The facsimile seal appearing vias authorized byRobert m/="m"n,p.c*"
uVm12om.This does not serve m""electronically signed d"cu==f.
CERTIFICATION uFINDEPENDENCE:
� 1. NEK4D!etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
�
distributing products itevaluates.
| 2. NEMOletc.is not owned,operated orcontrolled byany company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This isa building code evaluation. Neither NEk8O|etc. no/RobertNinminen, P.E.ane, inany way,the Designer ofRecord for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
� @zozywcwuETC,LLC
(NNEMOjetc.
R06FINTCOMPONOT EVALUATION
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 61h Edition(2017) Florida Building Code through testing in accordance with the following Standards.
I Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2- STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.3/1507.1.1 Physical Properties ASTM D226 2009
1507.2.J 15b7,1.1,1507,2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
1507.11.2 Physical Properties ASTM D6163 2008
1507.11.2 Physical Properties ASTM X6164 2011
1507.11.2 Physical Properties ASTM D6222 207.1
1507.11.2 Physical Properties ASTM D6509 2009
TA5110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Date Entity Examinat€on Reference Date
ERD(TST 6049) Wind Uplift 11757.08.01-1 OB/13/2001 ERD(TST 6049) Tensile adhesion P40390.04.25 04/03/2015
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) TAS 103 P44360.10.14-111 05/18/2015
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Wind Uplift PLYG-SC8905.05,16-1 05/17/2016
ERD(TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 ERD(TST 6049) ASTM 01970 PLYG-SC10130.06.16-1 06/27/2016
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Tensile adhesion PLYG-SC20130.06.16-2 06/27/2016
ERD(TST 6049) Wind Uplift P30540.11.09-Rl 11/30/2009 ERD(TST 6049) TAS 103 PLYG-SC10130.06.16-3 06/27/1016•
ERD(TST 6649) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD(TST 6049) ASTM D1970/D4798 PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) ASTM D4977 P11030.11.09-3 11/30/2009 ERD(TST 6049) TAS 103 PLYG-SC13040.12.16 12/27/2016
ERD(TST 6049) ASTM 61970 P33360.06.10 06/25/2010 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) TA5103 P33370.03.11 03/02/2011 ERD(TST 6049) TAS 103 PLYG-SC12115.08.17 08/08/2017
ERD(TST 6049) Tensile Adhesion P33370.04.11 04126/2011 ERD(TST 6049) TA5103 PLYG-SC13035.08.17 10/31/2017
ERD(TST 6049) ASTM 01970 P37300.10.11 10119/2011 FM(TST 1867) Wind Uplift 3004091 01/12/2000
ERD(TST 6049) TA5103 P40390.08.12-1 08/06/2012 ICC-ES(EVL 2396) IBC Compliance ESR-1697 04/01/2019
ERD(TST 6049) Tensile Adhesion P40390.08.12-2 08107/2012 M-D'(CER 1592) HVHZ Compliance NOA 17.0614.22 07/06/2017
ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 MTI(TST 2508) ASTM D4798 JX20H7A 04/01/20D8
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO(TST 6049) ASTM D1970 4-13LYG-18.004.03.18 03/29/2018
ERD(TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO(TST 6049) Wind Uplift AL-PLYG-18.003.01.19 01/11/2019
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 NEMO(TST 6049) ASTM D6153 45-PLYG-28002.01.19-A 01/24/2019
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04130/2013 NEMO(TST 6049) ASTM D6222 45-PLYG-18-002.05.19-C- 05/2012019
ERD(TST 6049) ASTM D6164 P37590.03.13-3A 05/06/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18.404.10.19-G 16/08/2019
ERD(TST 6049) ASTM D6509 P37590.03.13.1-R1 06/26/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18.004.10.19-1 10/08/2019
ERD(TST 6049) Wind Uplift P41630.08.13 08106/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18.004.10.19-L 10/09/2019
ERD(TST 6049) ASTM D4601 P45940.09:13 09/04/2013 NEMO(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-01.A 10/1012019.
ERD(TST 6049) Wind Uplift 1711751.05.03-111 11/26/2013 PRI(TST 5878) Tensile Adhesion PR101111 04/08/2002
ERD(TST 6049) Wind Uplift P11781.11.03.111 11/26/2013 PRI(TST 5878) TA5103 PUSA-018-02-01 07/14/2003
ERD(TST 6049) 30/90 physicals P45270,05.14 05/12/2014 PRI(TST 5878) TA5103 PUSA-035-02-01 09/29/2006
ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 PRI(TST 5878) TAS 103 PUSA-055-02-02 12/10/2007
ERD(TST 6049) Tensile adhesion 6020.09.14-6 09/08/2014 PRI(TST 5878) ASTM D6222 PUSA-061-02-02 01/28/2008
ERD(TST 6049) Tensile adhesion P46520.10.14 10/03/2014 PRI(TST 5878) ASTM D6164 PUSA-088-02-0i 07/29/2009
ERD(TST 6049) ASTM D1970/D4798 P43290.10.14 10/17/2014 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate ofAuthorizotion#32455 a EDITION(2017)FBC NON-HVHZ EVALUATION F1.5259-1129
Polyglass Roof Underlayments;(954)233-1230 Revision 2S:10/14/2019
Page 2 of 16
ODEMO I etc.
Entity Examination Reference Date Entity Examination Reference Date
ERD(TST 6049) TAS 103 PLYG-SC7550.03.15 03/24/2015 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
UL(QUA962S) Quality Control Service Confirmation 09/13/2018
4. PRODUCT DESCRIPTION:
Product Specification Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet
4.3 Elastoflex G TU M-D 13-004 PA Polyester-reinforced,modified bitumen tile underlayment
FRSA/TRI April 2012 composed of a sand-surfaced SBS modified bitumen back-
side and granule-surfaced APP modified bitumen top-side
4.4 Elastoflex S6 G ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRI April 2012
4*5 Elastoflex 16 G FR ASTM D6164 F1 Polyester-reinforced,SBS modified bitumen cap sleet
FRSA/TRI April 2012
4.6 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TR1 April 2012
4.7 HydraGuard Dual Pro ASTM D1970 R Nominal 60-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.8 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
TAS 103 waterproofing membrane,fiberglass reinforced,with a
FRSA/TRI April 2012 polyester fabric surface
4.9 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
(FR) FRSA/TRI April 2012
4.10, Polyflex G ASTM D6212 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the
"Two Ply System"from FRSA/TRI April 2012(04-12)
beneath mechanically fastened or adhered tile roof
systems
4.11 Polyflex G FR ASTM D6222 FL Polyestet-reinforced,APP modified bitumen cap sheet for
FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the
"Two Ply System"from FRSA/TRl April 2012(04-12)
beneath mechanically fastened tile roof systems
4.12 Polyflex SA P ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.13 Polyflex SA P FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.14 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet
4.15 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet
4.16 Polystick IR-Xe ASTM D1970 FL,PA Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.17 Polystick MTS Plus TAS 103 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012 membrane,glass fiber reinforced,surfaced with
polyolefinic,film surface
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R25
Certificate of Authorization#324SS 6 TH EDITION(2017)FSC NON-HVHZ EVALUATION FL52s9_R29
Polyglass Roof Underlayments;(954)233.1230 Revision 25:10114/2019
Page 3 of 16
^
'
ONEMO I etc.
4. PRODUCT DESCRIPTION:
Plant(s) Description
�
4.18 Polystick MU-X ASTM D1970 FL,NV,PA Nominal 54-mil thick dUal-layer rubberized asphalt
(See Section 5.8) waterproofing membrane,fiberglass reinforced,with apolypropylene film surface
4.19 Polystick TU Max ASTM D1970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103 membrane with a 190 g/m2 polyester fabric surface
FR5A/TRI April 2012
4.20 Polystick TU P TAS 103 TX Nominal 130-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012 membrane,glass-fiber/polyester reinforced,with a
granular surface
4.21 Polystick TU Plus ASTM D1970 FL,PA Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103 membrane,glass fiber reinforced,with a polyester fabric
FRSA/TRI.Aprll 2012 surface
5. LIMITATIONS-*
5.1 This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
�
retained specifically for that purpose.
5.2 This Evaluation Report is not for use inthe HVMZ
53' Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within.
F8Capproval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
MEMO I etc.
TABLE 1: ROOF COVER OPTIONS
Wood Shakes
Underlayment Asphalt Shingles Nall-On Tile Foam-On Tile Metal &Shingles Slate
Polystick MTS Plus Yes Yes No Yes Yes Yes
Polystick MU-X f Yes No No Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick TU P No Yes Yes (See 5.5.1) No No No
Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
5.5.1 "Foam-On Tile"is limited to use of the fallowing Approved tile adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS'
Florida Product
Adhesive Approval Underlayments
DAP Foam Touch'n Seal StormBond FL14506 Polystick TU Max or Polystick TU Plus
Roof Tile Adhesive
Dow TileBondT" FL22525 HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or
Polystick TU Plus
Elastoflex G TU,Elastoflex 56 G,HydraGuard Tile Pro,Mule-Hide SA-APP
ICP Adhesives Polyset°AH-160 FL6332 Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex G,Polyflex SA P,
Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus
Elastoflex 56 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-
ICP Adhesives Polyset5 RTA-1 FL6276 Hide SA-APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,
Polystick TU Max,Polystick TU P or Palystick TU Plus
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates(designed to meet wind loads for project)
Underlayment Application
Type Primer Material(s)
plywood,OSB,Southern Yellow Pine or Huber
HydraGuard Dual Pro, Deck/ (Optional)ASTM D41 Engineered Woods"ZIP System"Panels
HydraGuard Tile Pro, sheathing
ASTM D41 structural concrete
Polystick(all variations), self ASTM 01289 Type 11 Class 1 polyisocyanurate,ASTM
Mule-Hide SA-APP Cap adhering Insulation (Optional)ASTM 041 C1289 Type V polyisocyanurate-composite,DensDeck
Sheet,Mule-Hide SA-APF or WB-3000
Cap Sheet(FR),Polyflex Prime or SECUROCK Gypsum-Fiber Roof Board
SA P or Polyflex SA P FR Base N A ASTM D226 felt,Elastobase,Elastobase P or Mule-Hide
Sheet Nail Base
I
Deck ASTM 041 structural concrete
Elastoflex G TU,Elastoflex hot asphalt Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
S6 G or Elastoflex 56 G FR Base N/A ASTM D226 felt,Elastobase,Elastobase P,Mule-Hide Nail
Sheet Base or Polyglass G2 Base
Deck ASTM D41 structural concrete
Polyflex G or Polyflex G FR torch- Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
applied Base N/A Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass
Sheet I G2 Base or Polyglass Base
Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,I.I.C. Evaluation Report P12060.02.09-R25
Certificate afAuthorization#32455 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5254 R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 5 of 16
ODEMO i etc.
5.6.1 Wind Resistance for Underlayment Systems-in Foam-On Tile Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April
2012(04-12)and are used in foam-on or mortar-set the applications. Maximum Design Pressure is the result of testing for
wind load'resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin
of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609
for determination of design wind loads.
#1 Maximum Design Pressure=-52.5 psf:
Deck: APA rated,7/16 CAT,0.418 in:,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min.4-inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP'Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#2 Maximum Design Pressure,=-90 psf:
Deck: Min.15/32-1nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APR Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga,x 1%"ring shank nails
through 32 ga.;1-5/8"diameter tin caps spaced 12-inch o.c.
44 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction:
Primer: WB-3000
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Poiyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 134"ring shank nails
through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG1f10 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#b Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max,Polystick TU P or Polystick TU Pius,self-adhered.
#7 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to'satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment:Elastoflex G TU or Elastoflex S6 G;applied in full mopping of hot asphalt or Polyflex G,torch-applied.
I
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certiflcate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1129
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 6 of 16
ONEMO etc.
#8 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#10 _Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1) 2
or two( )layers ASTM D226,Type II felt
Fasteners; 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c,at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch.o.c,at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered,
Underlaymeht:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
#12 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2),layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;-for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#13 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex'G,torch-applied.
#14 _Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEMO ETC,U.C. Evaluation Report P12060.02.09-R25
Certificate o/Authorization#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION F15259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 7 of 16
ONEMOJetc.
#15 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: 12 ga.annular ring shank nails.with 1-5/8"diameter tin caps
Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#16 Maximum;Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
#17 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#18 Maximum Design Pressure=-52.5 psf:
Deck: Min,15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows,
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
419 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#20 Maximum Design Pressure=-60 psf;
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1125
Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1129
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 8 of 16
ON EMO I etc.
#22 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners:. Simplex MARX Cap Fasteners
Spacing: B-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide 5A-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Poiystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#23 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and B-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
#25 Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#26 Maximum Design Pressure=-67.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows,
Primer: (Optional)PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick.TU Plus,self-adhered.
#27 Maximum Design Pressure=-67,5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
i
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authorization t132455 6TH EDITION(2017)FBC NON-HVH2 EVALUATION 1`15259-1129
Polyglass Roof Underlayments;(954)233.1230 Revision 25:10/14/2019
Page 9 of 16
01141EM0 I etc.
#28 Maximum Design Pressure=-67.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c,at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
#29 Maximum Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG,3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c.at the 4-inch wide.side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#30 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or,poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#31 _Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#32 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"•Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,.applied in full mopping of hot asphalt.
#33 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to-meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o:c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#34 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate oJAuthorization#32455 6W EDITION(2017)FBC NON-HVHZ EVALUATION FLS259-R29
Polyglass Roof Underloyments;(954)233-1230 Revision 25:10/14/2019
Page 10 of 16
INEM0 I etc.
#35 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OS8 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c,.at.the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#36 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows,
Underlayment:Polyflex G,torch-applied.
#37 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 318-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#38 Maximum Design Pressure=-97.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX.Cap Fasteners
l Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#39 Maximum Design Pressure=-97.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#40 Maximum Design Pressure=-97.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
#41 _Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally'spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
MEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authorization 02455 6TH{EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-RZS
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 11 of 16
NNEMO I etc.
#42 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB,sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#43 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet,project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o,c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0,418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the hales of the plate,parallel to
the width-direction of the.sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o,c.at three(3)equally spaced staggered center rows,
Underlayment:Polyflex G,torch-applied.
#45 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o,c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MT5 Plus,self-adhered
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered,
446 Maximum Design Pressure=-120 psf:
Deck: 'Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#47 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or,Elastoflex S6 G,applied in full mopping of hot asphalt
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authorization#32455 6t-EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 12 of 16
UN
NEMO I etc.
##48 Maximum Design Pressure=-127.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:_ Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#49 Maximum Design Pressure=-127.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#50 Maximum Design Pressure=-127.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.;Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
5.6.1.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum Design
Pressure of-45 psf.
5.6.1.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Lass
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk` carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Maximum Exposure(days)
Elastoflex G TU,HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick MTS Plus,Polystick TU 180
Max,Polystick TU'P or Polystick TU Plus
Polystick IR-Xe or Polystick MU-X 90
Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base 30
180
(for adhesive-set tile)
Elastoflex S6 G,Elastoflex S6 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet UNLIMITED
(FR),Polyflex G,Polyflex G FR,Polyflex SA P or Polyflex SA P FR
(for mechanically fastened roof
prepared roof covers)
5.8 Polystick MLI-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing
felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in
Section 4.3,Nate 1 of ASTM D1970-15,should be established as to slip resistance.
NEW ETC,LLC. Evaluation Report 1312060.02.09-1125
Certificate of Authorization#332455 67"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Undedayments;(954)233-1230 Revision 25.,10/1412019
Page 13 of 16
ONEM®I etc.
5.9 Tile Slippage Limitations FRSA RIApril 2012(04-12)):
When loading roof tileson'the underlayment in direct-deektile assemblies,the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using batten's during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE.LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Elastoflex G TU Flat 10-tile stack 7:12
Lugged 84111'stack(6 over 2) 6:12
Elastoflex S6 G or S6 G FR Flat'or Lugged 6-tile stack(4 over 2) 4:12
HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS'Plus Flat 6-tile stack(4 over 2) 5:12
Lugged 6-tile stack(4 over 2) 4:12
Flat 6-tile stack(4 over 2)or 10=tile;stack 7:12
Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat 6-tile stack(4-overt) 6:12
!!! Lugged 67tile•stack(4 over 2) 4:12
Polystick TU Plus Flat or,Lugged 6-tile stack(4 over 2) 7:12
Flat or Lugged 10-tile stack 6:12
6. INSTALLATION: -
6.1 Polyglass Roof Underlayments shall be installed,in accordance with Polyglass published installation requirements subject to the'
Limitations,set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris,prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226,Type 11 underlayment in FBC Table 1507.1.1 for
the type of prepared roof"covering to be installed and Polyglass published,requirements.
Elastobase;Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick,Polyflex SAP,Polyflex SA P FR,Mule=
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU,Elastoflex°S6 G or Elastoflex 56 G FR in hot
asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer
underlayment,as set forth in Table 1.
6:3.2 Tile Applications:
Elastobase, Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically,attached base sheet in the "Two Ply
System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.1 herein,coupied;with FRSA/TRI,April,
2012(04-12)Installation Manual,
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authorization#32455 6"EDITION(2017)FBC NOM-HVHZ EVALUATION F1.5259-1129.
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page'14 of 16
NNEMO I etc.
6.4 HydraGuard Dual Pro,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,
Polyflex SA P FR,Polystick IR-Xe,Polystick MTS Plus,Polystick MU-X,Polystick TU Max,Polystick TU P or Polystick TU Plus:
6.4.1 General:
All seat-lap seams(selvage laps)must be firmly rolled with a in t^ €
r .
accordance with Polyglass requirements to ensure full contact
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile `
Pro, align the edge of the top sheet to the end of the glue
pattern(the sheet will overlap the fabric).
r
a
. ..
View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
6.4.2 Non-Tile Applications:
Shall be installed incompliance with the codified requirements for ASTM D1970(except Polystick TU P) underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to.be installed and Polyglass published requirements.
6.4:3 Tile Applications(excludes HydraGuard Dual Pro Polystick IR-Xe and Polystick M":
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI April 2012(04-12)and
Polyglass published requirements.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base Sheet
fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications.,refer to Section 5.6.1 herein.
6.4.4 Multi-Ply Underlayment Systems:
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max,
Polystick TU P or Polystick TU Plus is allowable for use under,mechanically attached prepared roof systems. Limits of use are
those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is
desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max,Polystick TU P or Polystick TU Plus is
allowable for use under adhesive-set tile systems. Limits of use are those associated with the top-layer material. This is not a
requirement,but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6-G FR shall be installed in compliance with current Polyglass•published installation
requirements. For use in tile applications:.
✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"
from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"
from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet"
in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile.roof systems.
✓ Elastoflex S6 G FR is for use as an alternate'to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap
Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath.mechanically fastened the roof systems.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R25
Certificate of Authorization,#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATIONFL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page'15 of l6
ONEMO I etc.
6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex 56 G or Elastoflex56 G FR shall be fully asphalt-applied to the substrates
noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course
to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-
12)beneath mechanically fastened or adhered tile roof systems(Refer to Table 2 for base sheet options).
✓ PolyflexG FR is for use as an alternate to the Heat Applied "Cap Sheet"in the'Two Ply System"from FRSA/TRI April 2012
(04-12)beneath mechanically fastened'tile`roof systems(Refer to Table 2 forbase sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and
end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.-Refer to Table 2
herein,and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12)must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed,such as the use of battens or nail-boards, to prevent tile
sliding and/or damage to the underlayment during the loading process.
7. BUILDING PERMIT REQUIREMENTS:
As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this,product.
8. MANUFACTURING PLANTS:
Contact the noted OA agency for information on product locations covered for F.A.C. 61620-3 QA requirements. Refer to
Section 4 herein for product&production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R25
Certificate o/Authorization X32455 67"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019