Loading...
HomeMy WebLinkAboutREVISION, -NEW REV 6.16.20 SUBMITTED OFFICE USE ONLY: DATE FILED: PERMIT# SLC 2003-0225 REVISION FEE: RECEIPT# PLANNING & DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 8242 Martingale Ln, Port St. Lucie, FL 34986, US DETAILED DESCRIPTION OF PROJECT REVISIONS: Change to panel layout and three line diagram CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: EC13006226 ST. LUCIE CO CERT. #: BUSINESS NAME: Tesla Energy Operations Inc. QUALIFIERS NAME: Nicholas Armstrong ADDRESS: 8500 Parkline Rd. CITY: Orlando STATE: FL ZIP: 32809 PHONE (DAYTIME): 9542183426 FAX: OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC: 9123109 Revised 06130/17 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED BUILDING CONC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER. EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL — LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. VICINITY MAP INDEX 01 Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES -, Sheet 5 THREE LINE DIAGRAM - Sheet 6 THREE LINE DIAGRAM 1. ALL WORK SHALL COMPLY WITH THE 2017 Sheet 7 LOAD CALCULATIONS FLORIDA BUILDING CODE (6TH EDITION), FLORIDA FIRE Cutsheets Attached PREVENTION CODE (6TH EDITION). 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR F AHJ: St. Lucie County REV BY DATE COMMENTS REV A I NAME I DATE COMMENTS REV B Yandc 6/12/20 I RELOCATED ALL LOADS TO 1 PANEL PER CUSTOMER REV C DZ 6/12/2020 MP1 LAYOUT CHANGING UTILITY: Florida Power and Light 1 10 U481 11 lug O s J B-3 4 917 3 O O CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER: Iker Leycegul 15.12 KW PV ARRAY T - 5 L n CONTAINED SHALL NOT BE USED FOR THE Fred Alcindor BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 8242 Martingale Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (48) Hanwha Q CELLS # Q.PEAK DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Multiple Inverters 7723322444 COVER SHEET 1 C 6/12/2020 PITCH: 27 ARRAY PITCH:27 MP1 AZIMUTH:46 ARRAY AZIMUTH:46 MATERIAL: Low Profile W-Tile STORY: 2 Stories PITCH: 27 ARRAY PITCH:27 MP2 AZIMUTH:226 ARRAY AZIMUTH: 226 MATERIAL: Low Profile W-Tile STORY: 2 Stories PITCH: 27 ARRAY PITCH:27 MP3 AZIMUTH:226 ARRAY AZIMUTH: 226 MATERIAL: Low Profile W-Tile STORY: 2 Stories T \6ft NO FLY ZONE sv m I I LEGEND ® I S� I \ IW I (E) UTILITY METER & WARNING LABEL ®I I �FS Ins INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS T F B RELAY AUTOMATIC RELAY DC DCDISCONNECT & WARNING LABELS I \ -> m \ ® ® \ �N © AC DISCONNECT & WARNING LABELS sv DC JUNCTION/COMBINER BOX & LABELS / 1 LFSB ENERGY STORAGE SYSTEM FOR STAND Ess ALONE OPERATION O ; DISTRIBUTION PANEL & LABELS p/ f' 1� InN� RE®® LC� � LOAD CENTER & WARNING LABELS Int LL RELAY AC O DEDICATED PV SYSTEM METER se H ® © RAPID SHUTDOWN Eft NO FLY ZONE � �ES � kE s i RSD `E s� J STANDOFF LOCATIONS s� J CONDUIT RUN ON EXTERIOR Front Of House r CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r, It 11 INTERIOR EQUIPMENT IS DASHED L='J SITE PLAN Scale:1/16" = 1' (E)DRIVEWAY 01' 16' 32' s 8242 Martingale Ln J B-3 4 917 3 00 CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER: Iker LeycegUl 15.12 KW PV ARRAY T = 5 L n CONTAINED SHALL NOT BE USED FOR THE Fred Alcindor BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 8242 Martingale Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (48) Hanwha Q CELLS # Q.PEAK DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN [,,Multiple VERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. VERTE Inverters 7723322444 SITE PLAN 2 C 6/12/2020 S1 (N) PV MODULE (E) MOUNTING PLANE (MP) SV TYPICAL PV SIDE VIEW NTS INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL LOCATION. " DIA BOLT & NUT (1) (2) (Z) (3) 2) CLEAN PAPER AROUND PILOT ZEP SPANNER BAR CLAMP (3) ADJUST STANDOFF TO BATTEN 11 1 HEIGHT. STANDOFF � I SEAL PILOT HOLES AND BOTTOM (E) TILE U U (4) OF STANDOFF WITH POLYURETHANE (E) ROOF DECKING (5) (4) SEALANT. 5/16" DIA STAINLESS STEEL LAG BOLT (5) LAG STANDOFF INTO RAFTER. (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (6) NOTCH TILE WEATHERING TO FIT (E) RAFTER #-5T� AROUND STANDOFF. Z) REINSTALL TILE. J B-3 4 917 3 00 CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER: Iker LeyCegui 15.12 KW PV ARRAY T 5 L n CONTAINED SHALL NOT BE USED FOR THE Fred Alcindor BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 8242 Martingale Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (48) Hanwha Q CELLS # Q.PEAK DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Multiple Inverters 7723322444 STRUCTURAL VIEWS 3 C 6/12/2020 Jobsite Specific Design Criteria Design Code ASCE-7-10 Importance Factor 1 1 Ultimate Wind Speed V—Ult 160 Fig.1609A Exposure Category C Section 26.7 Ground Snow Load P9 0 Table 7-1 MP Specific Design Information MP Name MP3 MP2 MP1 Roofing Low Profile W—Tile Low Profile W—Tile Low Profile W—Tile Standoff ZEP Mighty Hook ZEP Mighty Hook ZEP Mighty Hook Pitch 27 27 27 SL/RLL: PV 0.0 psf 0.0 psf 0.0 psf SL/RLL Non—PV 18.0 psf 18.0 psf 18.0 psf Standoff Spacing and Layout MP Name MP3 MP2 MP1 Landscape X—Spacing 48" 48" 48" Landscape 18" 18" 18" X—Cantilever Landscape Y—Spacing 39" 39" 39" Landscape 20" 20" 2D" Y—Cantilever Portrait X—Spacing 24" 24" 24" Portrait X—Cantilever 12" 12" 12" Portrait Y—Spacing 52" 52" 52" Portrait Y—Cantilever 24" 24" 24" Layout Not Staggered Not Staggered Not Staggered X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters. J B-3 4 917 3 O O CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: Iker LeyCegU I 15.12 KW PV ARRAY Fred Alcindor -_ CONTAINED SHAA LL NOT BE USED FOR THE � � BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: TSLri SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 8242 Martingale Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (48) Hanwho Q CELLS # Q.PEAK DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Multiple Inverters 7723322444 UPLIFT CALCULATIONS 4 C 6/12/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:304 287 007 C-46, C-10 Underground Service Entrance E 200A MAIN SERVICE PANEL E� 20OA/2P MAIN CIRCUIT BREAKER N) 225A LOAD CENTER 9 AUTOMATIC RELAY 10 (E) WIRING X Y 200A/2P 60Al2P TO EXISTING N SOLAR r------ -- G — — — N I I J I I EGC! N L2 L1 I OA 2P I V I I I I TO I I EXISTING SOLAR ----- I . 2P L1 2256 2P I 11 L2 N W ENERGY STORAGE SYSTEM I v`———— EGC 4 TO 120/240V i . 2P 11 Ll L2 W SINGLE PHASE (E) LOADS I UTILITY SERVICE N ENERGY STORAGE SYSTEM EGC (E) 200A I 0A/2P DISTRIBUTION PANEL I 11 L1 Lz W N ENERGY STORAGE SYSTEM EGC I OA/2P m 11 L1 L2 N W ENERGY STORAGE SYSTEM L------- EGC Y (1)Tesla 1118431-00—L � 1 AWG #2/0, THWN-2, Black BACK—UP GATEWAY; for ACPW2.0, ASY, NA with 3G w/Antenna, PW2.0, 1OkA SCC 9 6F(1)AWG #2/0, THWN-2, Black AC —(1)Siemens #EQ8695f MBK200A IL�-LL(1)AWG #2/0, THWN-2, Black Circuit Breaker M K 20OA/2P, 22kAIC —(1)AWG #6, THWN-2, Green —(1)Conduit Kit; 2" PVC, Sch. 80 X (1)SQUARE D #HQM260 (1)AWG #1, THWN-2, Black Breaker; A 2P, 2 Spaces (1)AWG #1, THWN-2, Red —(1)SQUARE D #i0M2040L225PRB Load Center;225A bus,Convertible,NEMA3R,20sp/40cir,120v/240v,1OkAIC,Surface (1)AWG #1, THWN-2, White —(1)SQUARE D HOM220OBB —(1)AWG #6 THWN-2, Green —(1)Conduit Kit; 2" PVC, Sch. 80 # Breaker; OA/2P, 4 Spaces (1)AWG #10, THWN-2, Black —(1)SQUARE D t�{OM4RK2LA Retaining Rit; 150A-225A Convertible LCs, Series S01 & S02 (1)AWG #10, THWN-2, Red —(5)SQUARE D #HQM230 "' (1)AWG #10, THWN-2, White Breaker; A 2P, 2 Spaces —(1)AWG #10, THWN-2, Green —(1)SQUARE D #HQM260 —(1)Conduit Kit; 2" PVC, Sch. 80 Breaker; A/2P, 2 Spaces 3 V (1)Gutter Box Metal; 4"x4"x4' , Box w/cover; Nema 3R W (4)1092170-05—J TESLA AC POWERWALL 2.0; Home Energy Storage,1 3.5KWH, Stackable, 5.8kVA CON — THE INFORMATION HEREIN JOB NUMBER: J B-3 4917 3 00 CUSTOMER: DESCRIPTION: DESIGN: CONTTAINEDAINED AL SHALL NOT BE USED FOR THE Iker LeyCegui 15.12 KW PV ARRAY Fred Alcindor T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 8242 Martingale Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITH e THE SALE AND USE OF THE RESPECTIVE (48) Hanwho Q CELLS # Q.PEAK DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Multiple Inverters 7723322444 THREE LINE DIAGRAM 5 C 6/12/2020 INVERTER SPECS MODULE SPECS LICENSE INV 1 - (1) SolarEdge Technologies Ltd. #SE5000H-US [24OV] - (48) Hanwha Q CELLS #Q.PEAK DUO BLK-G5/SC315 Inverter; 5000W,24OV/208V,997/98.57;HD Wave W/Unifed Disco and ZB,AFCI PV Module; 315W, 292.2 PTC, 4OMM, Black Frame, MC4, ZEP, 1000V INV 2 - (1) SolarEdge Technologies Ltd. #SE1000OH-US [240V] Inverter; 1000OW,24OV/208V,9874HD Wave w/Unifed Disco and ZB,AFCI Voc: 40.29 Vpmax: 33.46 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER Inverter 1 CUTLER-HAMMER SolarEdge Technologies Ltd. SE5000H-US [240V] B Ll z4ov TO MAIN PANEL Lz AND ENERGY STORAGE SYSTEMY N 4 1 --- GND ------------------------------------- EGCI DC+ DC+ - - - GEC ---I DC- I I DC- I MP 3: 1x16 GND -- EGC--------------------------- ---'------- EGC -------------- ----� Inverter 2 8 CUTLER-HAMMER g SolarEdge Technologies Ltd. 6 (2 DC+ - - - SE1000OH-US [240V] DC- MP 1: 1x17 C zao v ----- ----------- EGC ----r-------------Ll ----- -------------- AND ENERGY TO MAIN PANEL Lz Dc+ � STORAGE SYSTEM JA I I N DC- i 5 3 -- GND -_- EGCI DC+ + ---------------------------------- - GEC ---lN DC- C MP 2: 1x15 D EG -- C- ------------------------ --F-------- G Y- GN -------------- ----� (1)Conduit Kit; 3/4" EMT Voc* = MAX VOC AT MIN TEMP B (1)CUTLER-HAMMER #DG221UR8 AC DC Disconnect; 30A, 240Vac, Non-Fusible, NEMA 3R - )CUTLER AMMER #DG030N6 \,�48 SOLAREDGE #P400-5NM4MTM-NM22 Ground/Neutral it 30A, General Duty(EM P V ( ) PowerBox Optimizer; 40OW, MC4, ZEP, Al backplate EC- )CUTLER-HAMMER # 40Vac, No Disconnect; 60A, 240Vac, Non-Fusible, NEMA 3R -(1)CUTLER-�1AMMER #DG100NB Ground/Neutral it; 60-100A, General Duty(DG) (1)AWG #10, THWN-2, Black (1)AWG #10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O L-L(1)AWG #10, THAN-2, Red ® (1)AWG #10, THWN-2, Red Vmp =350 VDC Imp=14.21 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp =350 VDC Imp=14.21 ADC IIII�---CELL(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC (1)AWG #10, THHN/THWN-2, Green EGC -(1)Conduit Kit; 3/4" EMT -(1)AWG #8, THWN-2, Green EGC/GEC-(l)Conduit Kit; 3/4" EMT (1)AWG #10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG #10, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC (1)AWG #6, THWN-2, Black O® (1)AWG #10, THWN-2, Red Vmp =350 VDC Imp=13.32 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp =350 VDC Imp=15.1 ADC L-L(1)AWG #6, THWN-2, Red (1)AWG #10, THHN/THWN-2, Green EGC -(1)Conduit Kit; 3/4" EMT II�-LL(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=42 AAC (1)AWG #10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC -(1)AWG #8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4" EMT © (1)AWG #10, THWN-2, Red Vmp =350 VDC Imp=15.1 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp =350 VDC Imp=13.32 ADC (1)AWG #10, THHN/THWN-2, Green EGC -(1)Conduit Kit; 3/4" EMT J B-3 4 917 3 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED AL - THE INFORMATION HEREIN JOB NUMBER: Iker LeyCegUI 15.12 KW PV ARRAY T = 5 L n CONTAINED SHALL NOT BE USED FOR THE Fred Alcindor BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 8242 Martingale Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (48) Hanwho Q CELLS # Q.PEAK DUO BLK-G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Multiple Inverters 7723322444 THREE LINE DIAGRAM 6 C 6/12/2020 PANEL A CALCS PANEL B CALCS Whole Home Load Calcs NEC220.83 -R--sidential Load Calculation Version2.1 Whole Home Load Calcs LVL2 240 V NEC 220.83 -Residential Lead Calculation Version 2.' N EC 220.83 B 'The _ L1JL2 240 V general calculated load.. =hall be not less than 100% ofthe first S kVA plus 40°lu afthe remainder of the folloving loads..." NEC 220.83(B) '"The general calculated load shall be not less than 100% ofthe first 8 kVA plus 40% ofthe remainder of NEC 220.83(13x1) the follawingloads..." -he calculated floor area shall not include open porches, garages, ar unused ... spaces..." NEC 220.83(BX1) 'Th a calculated floor area shall not in clude open porches, garages, or unused ... spaces..." Fla or Area 3,192 square fleet x 3VAJsq It 9,576 VA Flo or Area 3,192 square feet x 3VAJ5q it 9.576 VA NEC 220.83(BX2) "1500,volt-amperes for each 2-wire, 20-ampere small appliance branch circuit and each laundry branch NEC 220.83(B2) ^150,3 vnk-amperes far each 2-wire, 20-ampere small appliance branch circuit and each laundry branch circuit...." circuit.._" Small Appliance Circuits 2 circuits x 1500VAJcireuit 3.ODD VA Laundry Circuits 1 circuits x 150OVAJcircuit 1,500 VA Small Appliance Cirouits 2 circuits x 1500VAJoircuit 3.ODD VA Laundry Circuits 1 circuits x 1500VAJoircuit 1.500 VA NEC 220.8,3(BK3) "The nameplate rating of all appliances... ranges, wall-mounted ovens, counter-mounted cooking units_.. NEC 220.8X8](3] "The nameplate rating of all appliances.... ranges, wall-mounted'ovens, counter-mounted cooking units... clothes dryers that are not conneoted to the laundry branch circuit.._ [and] water heaters" clothes dryers that are not cannectedtathe laundry branch circuit.._ [and] waterheaters" Load(240V unless otherwise indicated) ',Sum of Breakers VA I Dryer *NAME?l 5,000; Lead(24OV unliessothervvise indicated) ;Sum of Breakers; VA DishwashedGa rba ge Disposal #NAM E?1 2,7001 Range #NAM E'7: 9,600I Water Heater #NAME?; 4,800: Pump #NAM E 7I 7,6301 240V FAU JAi r H an dle r #NAME?1 19,2001 1 Other i #NAM E 17,250; 12C ` ti icrc.aaue 201 1,200: 50,180 total VA 17,280 total VA Total ofnon air-conditioning loads: 64,256 total VA Total ofnon air-conditioning loads: 31,356 total V -.. First 8 kVA oflDad at 1 00% 8,000 First 3 kVA of load at 100% 9,000 Remainder of load at 40% 22,502 Remainder of load at 40% 9,342 Adjusted total of non air-conditioning load 30,502 VA Adjustedtotal of non air-conditioning load 17,342 NEC 220.83(B) . "Heatingand air-condition load..." NEC 220.83(B) 6 "Heating and air-canditiong load..." Breaker VA Breaker i VA Sum ofAJC Equipment Units 701 10,224: Sum ofAJC Equipment Units 6; Sum of E lectric Furnaces I 01 Sum of Eleotrio Furnaces 1 0: Sum of E lectric Vehicle Charging Supply 01 Sum of E lectric Vehicle Charging Supply 01 —otal of?+.-C Loads and All Other Loads: 40,728 total VA Total ofA;C Loads and All Other Loads: 17.342 total ;.k Total Proposed Calculated Load: 189.99 Amps Total Proposed Calculated Load: 72.26 Amps T � SLr TESLFi @Copyrq tT__l=t,' _ _ _ - - �tT=- J B-3 4 917 3 00 CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN [MODULES: OB NUMBER: Iker LeyCegul 15.12 KW PV ARRAY T = 5 L n CONTAINED SHALL NOT BE USED FOR THE Fred Alcindor BENEFIT OF ANYONE EXCEPT TESTA INC., NOR OUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 8242 Martingale Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITHr THE SALE AND USE OF THE RESPECTIVE (48) Hanwha Q CELLS # Q.PEAK DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Multiple Inverters 7723322444 LOAD CALCULATIONS 7 C 6/12/2020 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 8242 Martingale Ln (x4) ENERGY STORAGE DEVICE AC DISCONNECT AC DISCONNECT INVERTER AND DC DISCONNECT INVERTER AND DC DISCONNECT ---------------------- -- - UTILITY SOLAR PHOTOVOLTAIC ARRAY(S-) 'J SERVICE PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-349173-00 CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-3 4 917 3 00 CUSTOMER: DESCRIPTION: DESIGN: Iker LeyCegU I 15.12 KW PV ARRAY T 5 L n CONTAINED SHALL NOT BE USED FOR THE Fred Alcindor _ BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: a e SHALL IT BE DISCLOSED IN WH OLE OR IN ZEP Mighty Hook 82 42 Ma rtn g Ln 54 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: Port St. Lucie FL 34986 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (48) Hanwho Q CELLS # Q.PEAK DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Multiple Inverters 7723322444 SITE PLAN PLACARD 8 C 6/12/2020 Label Location: Label Location: WARNING:PHOTOVOLTAIC POWER SOURCE Label WARNI WARNING Code:Per Code: Per Code: Per NEC 690.31.G.3 ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS 690.113.13 THE DC CONDUCTORS OF THIS '•1 Label • •n: TO BE USED WHEN LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND PHOTOVOLTAIC DC D IN THE OPEN POSITION INVERTERIS MAY BE ENERGIZED UNGROUNDED DISCONNECTCode:NEC ••1 Label • • Label Location: PHOTOVOLTAIC POINT OF -• MAXIMUM POWER-_ p p INTERCONNECTION Per • _ POINT CURRENT(Imp) A Per WARNING: ELECTRIC SHOCK • MAXIMUM POWER Code: HAZARD. DO NOT TOUCH CEC • 1 POINT VOLTAGE(Vmp)_VNEC 690.53 TERMINALS.TERMINALS ON MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)_V MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT(Isc)_A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC Label • •Per OPERATING VOLTAGE V WARNING ..- NEC ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED 690.5(C) NORMALLY GROUNDED Label • • CONDUCTORS MAY BE CAUTION -• UNGROUNDED AND ENERGIZED DUAL POWER SOURCE Per •.- SECOND SOURCE IS NEC 690.64.B.4 PHOTOVOLTAIC SYSTEM Label • • WARNING ' Per ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALSCEC ••1 = CAUTION ' -• TERMINALS ON BOTH LINE AND Per - LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFEDNEC 690.64.B.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING '• Per ..- INVERTER OUTPUT NEC Label • - • CONNECTION 690.64.B.7 PHOTOVOLTAIC AC -•I) sconnect DISCONNECTPer Code: THIS ODEV CERRENT (C): Conduit NEC 691 C): Combiner :• Distribution Panel• Interior • • Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A -• Center. Load OPERATING CURRENT PerCode: MAXIMUM AC OPERATING VOLTAGE VNEC 690.54 Interconnection Label Location: Label Location: BACKUP LOAD CENTER CAUTION - -Per ••- TRI POWER SOURCE Per Code: NEC 408.4 NEC SECOND SOURCE IS PHOTOVOLTAIC SYSTEM , THIRD SOURCE IS ENERGY STORAGE SYSTEM Label • • CAUTION DO NOT ADD NEW LOADSPer Code: ,•- • • Per WARNING ..- THIS EQUIPMENT FED BY NEC 1 .•_ Location: MULTIPLE SOURCES.TOTAL CAUTION ■Ili RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN THIS PANEL HAS SPLICED FEEDPer Code: SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. SHALL NOT EXCEED AMPACITY LOCATION OF DISCONNECT AT ENERGY OF BUSBAR. STORAGE BACKUP LOAD PANEL Label Label . . . NOMINAL E VOLTAGE. 1� 4�V Location: CAUTION -u Per ..- DUAL POWER SOURCE Per ••- CIRCUIT FROM ESS= 3A Per 1•.7(D) label t• •- marked in field SECdND SOURCE ISNEC 705.12(B)(3) ARC FA4ILTCLEARING ENERGY STORAGE SYSTEM TIME FROM ESS: 6�fT1S DATE OF CALCU CATION: Location:Label ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE dF SIGHTPerCode: rLabel Location: ENERGY STORAGE SYSTEM ON SITE - LOCATED ON ADJACENT WALLPer Code: Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALLPerCode: Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDE Per ••- Disconnect : Backup Load Center ■ Main Panel '=t',SoiarCity ZepSolar Next-Level PV Mounting Technology '+;',SolarCity ZepSolar Next-Level PV Mounting Technology ZS Span Components for concrete tile roofs _- 1x 3x 4x Spanner Bar Zep Groove cam root Part Nos. is 850-1400-4x 580-1399-3x 850-1398-1x Cround Zep —_ Spanner Bar _ Spanner Ctamp T-Lock w/ Array Skirt Splice Kit Spanner Clamp Part No.850-1401 Part No.850-1194 Listed to UL 2703 Listed to UL 2703 ComarCap Intertock AtljustaMaMlghtyHook �O 1 O Oil ,gMPAT-, Description PV mounting solution for concrete tile roofs � F Works with all Zep Compatible Modules Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Mighty Hook V2, HDG Interlock Cam Foot VI. LISTED Specifications Part No.850-1461 Part No.850-1388 Part No.850-1413 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 n Designed for pitch roofs Installs in portrait and landscape orientations Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 Wind tunnel report to ASCE 7-05 and 7-10 standards NOW • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" Valb • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No.850-1172 Part Nos.850-0113,850-1421, Part No.850-1448 ETL listed to UL 467 850-1460,850-1467 Listed to UL 1565 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1730-001 Rev A Date last exported:April 20,2015 2:14 PM Document#800-1730-001 Rev A Date last exported:April 20,2015 2:14 PM POWERWALL TYPICAL SYSTEM LAYOUTS Tesla Powerwall is a fully-integrated AC battery system for T WHOLE HOME BACKUP residential or light commercial use. Its rechargeable lithium-ion battery pack provides energyp storage for solar self-consumption, opcionai, time-based control,and backup. Powerwall's electrical interface provides a simple connection to Solar any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. O o O Solar inverter Main panel Backup Gateway Utility meter Grid including service disconnect T=5 L in PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 120/240 V Dimensions' 1150 mm x 753 mm x 147 mm Feed-In Type Split Phase (45.3 in x 29.6 in x 5.75 in) / Weight' 114 kg(251.3 Ibs) Grid Frequency 60 Hz Mounting options Floor or wall mount Total Energy' 14 kWh Powerwall Whole home Dimensions and weight differ slightly if manufactured before March 2019. backup Usable Energy' 13.S kWh Contact Tesla for additional information. 753 mm 147 mm Real Power,max continuous2 5 kW(charge and discharge) (29.6 in) (5.75 in) Real Power,peak(10s,off-grid/backs 7 kW(charge and discharge) Apparent Power,max continuous 5.8 kVA(charge and discharge) Apparent Power,peak(105,off-grid/backup) 7.2 kVA(charge and discharge) T o S L PARTIAL HOME BACKUP Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Optional 1150 mm l� Overcurrent Protection Device 30 A (45.3 in) Imbalance for Split-Phase Loads 100% � Power Factor Output Range +/-1.0 adjustable Solar Power Factor Range(full-rated power) +/-0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency'; 90% O o 0 o O Warranty 10years ENVIRONMENTAL SPECIFICATIONS O 'Values provided for 250C(770F),3.3 kW charge/discharge power. Solar Inverter In Backup mode,grid charge power is limited to 3.3 kW. Operating Temperature -200C to 500C(-40F to 122°F) Sub panel Backup Gateway Main panel Utility meter Grid 'AC to battery to AC,at beginning of life. Recommended Temperature 0°C to 300C(32°F to 86°F) COMPLIANCE INFORMATION - Operating Humidity(I Up to 100%,condensing T=5 L Storage Conditions -200C to 300C(-4°F to 86°F) Certifications UL 1642,UL 1741,UL 1973, Up to 95%RE,non-condensing UL 9540,IEEE 1547,UN 38.3 State of Energy(SoE):25%initial Grid Connection Worldwide Compatibility Maximum Elevation 3000 m(9843 ft) 0 O O Emissions FCC Part 15 Class B,ICES 003 Environment Indoor and outdoor rated Powerwall Backup loads Home loads Environmental RoHS Directive 2011/65/EU Enclosure Type NEMA 3R Seismic AC156,IEEE 693-2005(high) Ingress Rating IP67(Battery&Power Electronics) IP56(Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C(86°F) T = S L Fi TESLA.COM/ENERGY T = S L n NA-BACKUP-2019-06-11 TESLA.COM/ENERGY • solar=@@ solar=@@String Optimizer S05000 SOS000 INPUT String Optimizer Rated Input DC Power(' 5000 W Absolute Maximum Input Voltage 600 Vdc . (Voc..at.lowest temperature)... ............................. ................................................................................. ....... 5000 MPPT Operating Range 120-530 I Vdc ...................... ................................................................................. ........ Maximum Short Circuit Current(Isc)of • 12.5 Adc connected PV Module .................................... ................................................................................. ....... Maximum DC Input Current 13 Adc .................................... .. ....................................... Maximum Efficiency 99.1 %... .................................... ...................................... Weighted Efficiency 99 .................................... ................................................................................. Overvoltage Category II OUTPUT DURING OPERATION(STRING OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 12.5 Adc .................................... ................................................................................ ....... Maximum Output Voltage I 500V .................................... ........................... ...................................... ....... Operating Output Voltage range I 325-450 Vdc • OUTPUT DURING STANDBY(STRING OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per String Optimizer 25 Vdc STANDARD COMPLIANCE EMC FCC Par 15 Class B,61000-6-2,61000-6-3 Safety I 62109-1(class II safety),UL1741 .................................... ................................................................................. ........ pov+rr�y G ROHS Yes m .................................... ................................................................................. . �j Arc Detection(When Connected to `�Veats b SolarEd ge I nverter) UL1699B;NEC 690.11 w6ttf ................................................... .... ....... ................... ........ y Rapid Shutdown(When Connected to NEC 690.12 SolarEdge Inverter) INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 600 Vdc .................................... ................................................................................ ....... Dimensions(WxLxH),without bracket I 186x200x71/7.32x 7.87x2.8 I mm/in .. .................................... ................................................................................ ....... Weight(including cables) I 3.6/8 I kg/lb .................................... ................................................................................ ........ Input and Output Wire Type/Connector I Double insulated;4mm2(MC4) ..............Length...................... ..........................................6...................................... ....... I 150/ mm/in Input Wire .................................... ................................................................................. ....... Output Wire Length I (Female)800/31.5,(Male)900/35.4 mm/in .................................... ................................................................................. ........ Operating Temperature Range(2) I -40-+85/-40-+185 °C/°F .................................... ................................................................................. ........ Protection Rating I NEMA6 ...Relative.......Humi..dity........................ ...... ................................ 0-1...00........................................ ....... I .................................... ................................................................................ ....... Reverse current protection I 40 A lu Rated STC power of the module.Module of up.to+5%power tolerance is allowed. ix)Power de-rating from+1589F/+70°C. PV SYSTEM DESIGN HD-WAVE SE30001-11- HD-WAVE SE50001-11- SE5000A-US- SE10000A-US- US-SE380OH-US US-SE760OH-US SE760OA-US SE1140OA-US Maximum Input String per Optimizer 2 .......................................... .................... ..................... ..................... .................. Min#String Optimizers per Inverter 1 2 2 2 ............................... . Max#String Optimizers per Inverter 2 I 4 I 4 6 ......................................... Cost Effective PV power optimization at the string level Maximum Power per String Optimizer 5000W;do not exceed inverter Maximum DCPower .......................................... .................. ..................... ..................... `.i'........... Strings of Different Lengths and Orientations Yes — Connects to a string of modules,providing string Maximum Power Point Tracking(MPPT)while maintaining superior ,,, Refer to inverter datasheets. efficiency(99.1%) — Compatible with SolarEdge single phase inverters — Fast installation with a single bolt Next generation maintenance with optimizer-level monitoring — Safety voltage output(:525V)for installer and firefighter safety rc " O SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE, logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge www.solaredge.us are trademarks of their respective owners.Date:04/2018/VOI/ENG NA.Subject to change without notice. powered by MECHANICAL SPECIFICATION �ll0 Format 66.3in x 39.4in x 1.57in(including frame) 98° 6.3.,,6a6mm, (1685mm x 1000mm x 40mm) ax6.5mm, -14"(950mm) - 4.6.13615 Weight 44.5 1 bs(2 0.2 kg) Front Cover 0.13 in(3.2 mm)thermal ly pre-stressed glass with anti-reflection technology Back Cover Composite film 37,149 Frame Black anodized aluminum © 9°'fi1100°min �v� Now- Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells �ee_E1 Junction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83in (70-85mm x 50-70mm x 13-21mm),decentralized,IP67 Cable 4mm'Solar cable;W+ :43.3in(1100mm),(-)>-43.3in(1100mm) �r3.5„oOmm OCTAL. Connector Multi-Contact MC4,IP68 1.063-(27 ,T 4 T0.35°',9mm, ELECTRICAL CHARACTERISTICS Q. PEAK DUO BLK-G5/SC P-3201� POWER CLASS 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) Power at MPP2 PMPP [W] 310 315 320 SOLAR MODULE Short Circuit Current' IS° [A] 9.83 9.89 9.94 e Open Circuit Voltage- V0c [V] 40.02 40.29 40.56 s' Current at MPP' IMPP [A] 9.36 9.41 9.47 Voltage at MPP' VMPP IV] 33.12 33.46 33.80 The new Q.PEAK DUO BLK-G5/SC solar module from Q CELLS impresses Efficiency2 n [%] 2:18.4 2:18.7 >-19.0 thanks to innovative Q.ANTUM DUO Technology,which enables particularly MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOC3 high performance on a small surface, and a black Zep CompatibleTM frame Power atMPPI PMPP [W] 229.7 233.5 237.2 design for improved aesthetics, easy installation and increased safety. a Short Circuit Current' IGG [A] 7.93 7.97 8.02 Open Circuit Voltage` V0c IV] 37.43 37.69 37.94 Q.ANTUM s world-record-holding cell concept has now been combined Current at MPP' IMPP [A] 7.36 7.41 7.45 with state-of-the-art circuitry half cells and a six-busbar design, thus Voltage at MPP' VMPP [V] 31.20 31.52 31.84 achieving outstanding performance under real conditions - both with 11000W/m2,25°C,spectrum AM 1.5G z Measurement tolerances STC±3%;NOC±5% 380OW/m3,NOCT,spectrum AM 1.5G *typical values,actual values may differ low-intensity solar radiation as well as on hot, clear summer days. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY -_ Thereafter max.0.54%degradation per year. °hii6 At least 93.1%of nominal power up to l0 years. �i°°--I---- J Higher yield per surface area, lower BOS costs, higher power At least 85%of nominal power up to 25 years. AT W classes, and an efficiency rate of up to 19.3%. s= All data within measurement tolerances. GO L---1----1--------i Full warranties in accordance with the warranty A. es terms of the Q CELLS sales organization of your INNOVATIVE ALL-WEATHER TECHNOLOGY o B0respective country. 80 200 °nn 6n° o° z Optimal yields, whatever the weather with excellent low-light IRRADIANCE IW/m'] and temperature behavior. 0 vE2, Typical module performance under low irradiance conditions in 1. .,M,n.�,.0 P "°n° P=°n��°20 m acs20, comparison to STC conditions(25°C,1000W/m2). ENDURING HIGH PERFORMANCE QCELLS ". YIELD SECURITY TEMPERATURE COEFFICIENTS Long-term yield security with Anti LID and Anti PID Technology', TOP BRAND IVANTI AIR TECHNOLOGY Temperature Coefficient of Isn a [%/Kl +0.04 Temperature Coefficient of VG, [3 [%/Kl -0.28 Hot Spot Protect and Traceable Quality Tra.QTM. Temperature Coefficient of PMPP y [%/K] -0.37 Normal Operating Cell Temperature NOCT [°F] 113±5.4(45±3°C) N TRAC ABLE QUALITY L.IA EXTREME WEATHER RATING PROPERTIES DESIGN o High-tech aluminum alloy frame, certified for high snow 1111111diffi& Maximum System Voltage V,,, [V] 1000(IEC)/1000(UL) Safety Class II (5400 Pa) and wind loads(4000 Pa) regarding IEC. GOMpgT� Maximum Series Fuse Rating [A DC] 20 Fire Rating C(IEC)/TYPE 1(UL) o �Q 6� Design load,push(UL)2 [Ibs/ft'] 50(2400Pa) Permitted module temperature -40°F up to+185°F A RELIABLE INVESTMENT / on continuous duty (-40°C up to+s5°C)RR o OInclusive 12-year product warranty and 25-year �� v Design load,pull(UL)2 [Ibs/ft2] 50(2400Pa) 2 see installation manual linear performance guarantee2. °comppc��' QUALIFICATIONS t CERTIFICATES PACKAGING INFORMATION ° ILL 1703;CE-compliant; Number of Modules per Pallet 26 STATE OF THE ART MODULE TECHNOLOGY IEC 61215(Ed.2);IEC 61730(Ed.1),application class A _ Q.ANTUM DUO combines cutting edge cell separation APT test conditions according to Number of Pallets per 53'Trailer 32 pMPA i EC TS 62804-1:2015, 00',' Number of Pallets per 40'High Cube Container 26 and innovative wiring with Q.ANTUM Technology. method B(-150ov, 168h) pE Pallet Dimensions(L x W x H) 69.3in x 45.3in x 46.9in` CS 2 See data sheet on rear for further gcOO. (1760mm x 1150mm x 1190mm) THE IDEAL SOLUTION FOR: information. Pallet Weight 12681bs(575kg) - NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use ®Rooftop arrays on of this product. commercial/industrial N buildings Hanwha Q CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us Engineered in Germany OCELLS Sin le Phase Inverter witg HID-Wave Technology for North America Single Phase Inverter SE3000H-US SE380OH-US SE5000H-US SE6000H-US/ • C SE760OH-US / SE10000H-US / SE1140OH-US with HD-Wave Technology ,,, ,,, ,,,,m APPLICABLE TO INVERTERS WITH for North America PART NUMBER SEXXXXI-I-XXXXXBXX4 OUTPUT SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / 3800@240V 6000@240v 11400@240V Rated AC Power Output 3000 5000 7600 10000 VA 3300 @ 208V 5000 @ 208V 10000 @ 208V SE760OH-US / SE10000H-US / SE1140OH-US Maximum AC Power Output 3000 m 3800@240V 5000 6000@240V 7600 0000 11400@240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max, ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 240264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.51) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A p Ci Current @240V Maximum Continuous Output _ 16 24 - - 48.5 A Current @208V Power Factor 1,adjustable-0.85 to 0,85 ® GFDI Threshold 1 A p O Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT solar, [ r i�)wo e ® solar,3-- !;� 9 Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 15500 W Transformer-less,Ungrounded Yes Q Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VaI 8.5 10.5 13.5 1 16.5 20 1 27 30.5 Adc \ Maximum Input Current @208V( 9 13.5 27 Adc 4s as p ® Max.Input Short Circuit Current 45 Adc ' W _ Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 CEC Weighted Efficiency 99 99 @ 240V Optimized installation with HD-Wave technology 98.5@208V Nighttime Power Consumption <2.5 W "I For other regional settings please contact SolarEdge support / Specifically designed to work with UL1741 SA certified, for Cl Rule 21 grid compliance (1)A higher current source may be used;the inverter will limit its input current to the values stated / power optimizers / Record-breaking efficiency / Extremely small / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5%accuracy) solaredge.com solar Sin le Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional") Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi station for local connection Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to TI L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG Range DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/1T6 lb/kg Noise <25 1 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60141 °F/`C Protection Rating NEMA 4X(Inverter with Safety Switch) Revenue grade inverter P/N:SExxxxH-USOOOBNC4 i41 Full power up to at least 50°C/1227;for power de-rating information refer to:https://v w .solaredge.com/sites/default/files/se-temperature-derating-note-na,pdf ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date:1/2019N01/ENG NAM.Subject to change without notice. POWERWALL Backup Gateway The Backup Gateway for Tesla Powerwall provides energy management and monitoring for solar self-consumption,time-based control,and backup. The Backup Gateway controls connection to the grid,automatically detecting outages and providing a seamless transition to backup power.When equipped with a circuit breaker,the Backup Gateway can be installed at the service entrance. The Backup Gateway communicates directly with Powerwall,allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 230 V,120/240 V Dimensions 740 mm x 378 mm x 129 mm Feed-In Type Single&Split Phase (29.1 in x 14.9 in x 5.1 in) Weight 16.4 kg(36 Ibs) Grid Frequency 50 and 60 Hz Disconnect Current 200 A Mounting options Wall mount Maximum Input Short Circuit Current 10 kA 378 mm 129 mm Overcurrent Protection Device' 100-200 A;Service Entrance Rated (14.9 in) (5.1 in) Overvoltage Category Category IV El AC Meter Revenue grade(+/-1%) Connectivity Ethernet,Cellular(3G)2,Wi-Fi User Interface Tesla App Operating Modes Support for solar self-consumption, time-based control,and backup 740 mm Backup Operation Automatic disconnect for seamless (29.1 in) backup transition Modularity Supports up to 10 AC-coupled Powerwal Is Warranty 10 years 'Circuit breaker required for installation at service entrance. 2Celiular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS Certifications UL 1642,UL 1741,IEC 62109-1, Operating Temperature -20oC to 50oC(-4°F to 122°F) CSA C22.2.107.1 Operating Humidity(RH) Up to 100%,condensing Grid Connection Worldwide Compatibility Maximum Elevation 3000 m(9843 ft) Emissions FCC Part 15 Class B,ICES 003, IEC 61000-6-3,EN 55024, Environment Indoor and outdoor rated EN 301489-1,EN 301489-7, Enclosure Type NEMA 3R EN 301489-17 Ingress Rating IP44 Environmental RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation Seismic AC156,IEEE 693-2005(high) T S S L n 2018-03-22 TESLA COM/ENERGY