Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed window is incompliance with the 2017 Florida Building Code, 160 mph wind zone,
exposure "C", risk category II.
Exposure "C:' Multiplier for 15' mean roof height is 1.21
Wind Zone 4 28 x 1.21= 33.8
Wind Zone 5 34 x 1.21 = 41.1
Required Design Pressures: +/-41.1
Product: PGT SH5400 PVC Single Hung Non-impact NOA# 17-0630.6
Product Pressures:
806 Delaware Avenue
Fort Pierce, Florida 34950
+/-50