Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 �/� Certification for Design Load Compliance Project Name: r ) (f adc)upocd I o-f— Project Address: "I t o3 I KnQ) I u)CCd L n Permit #: Occupancy Type: S1_ Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X II III_IV Exposure Category:_B X C _D 4. Design Wind Velocity 160 mph X ASDLRFD End Zone Width: 6 ft S. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +19.6, -31.2 Zone 2: +19.6, -54.3 Zone 3: +19.6, -80.2 Zone 4: +34.1, -36.9 Zone 5: +34.1, 45.6 Garage: +28.5. a4.6 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? —Yes X Not Applicable Explain Why Not: Aspect Ratio <4:1 9. Is A Continuous Load Path Provided? X Yes NotApplicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces s t ted: at e, Date, an ea C Revised 12/07/ OS8 Donald J. Nuelle PE 52046 Print Name Cert # & Co. Cert Auth. Nuelle Engineering 11634 SW Rowena Street, P.S.L., FL 34987 Company Name & Address FILE COPY