Loading...
HomeMy WebLinkAboutProject Informationwrightsoft Load Short Form Entire House Job: Date: Oct 28, 2019 By: For: MW-01 9631 KNOLLWOOD LN, FORT PIERCE, FL 34951 Htg Clg Outside db(°F) 43 91 Inside db(°F) 70 72 Design TD (°F) 27 19 Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 0 65 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.8 kW 30073 Btuh 18 OF 1550 cfm 0.052 cfm/Btuh 0 in H2O Infiltration Method Construction quality Fireplaces Simplified Semi -tight 0 COOLING EQUIPMENT Make Lennox Trade 14ACX SERIES Cond 14ACX-047-230' Coil CBX27UH-048-230'++TDR AHRI ref 3869174 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.0 EER, 16 SEER 32550 Btuh 13950 Btuh 46500 Btuh 1550 cfm 0.047 cfm/Btuh 0 in H2O 0.69 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 305 4704 3908 244 184 HIS WIC 40 666 351 34 17 MASTER BATH 166 1781 2092 92 99 HER WIC 74 62 267 3 13 DEN 201 4178 3148 216 148 FOYER 69 1465 1370 76 65 DINING 175 2506 2224 130 105 MECH 34 414 695 21 33 UTILITY 59 72 772 4 36 BATH 2 58 995 1134 52 53 BED 2 180 1716 2795 89 132 BED 3 178 1761 2810 91 132 BATH 3 58 1659 1351 86 64 NOOK 147 3479 2685 180 126 KITCHEN 222 185 1965 10 93 ! M=ATI %A AAL A/100 G/A/AA fl19 n0a Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 'I" wrightSOW RlghtSulte® Universal 201212.1.05 RSU02818 )M C:1UsemUaWnlDowmentslWeghtaoft HVACtMW-01.rop Calc=MJS Front Doorfaws: N 2019-0c1-30 10:41:17 Page 1 U IILI I NALL Uo I Jul 333 lb "]a Entire House 2507 29931 32901 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 31420 Latent cooling 14837 1 n .ICCM1 ALL/ V I 1 LJVI LJJJI YVLJI IJJV I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C + W19Q:1tSOft' RlghtSuite® Universal 201212.1.05 RSU02818 JIM C:1UsersUasonlDocumentslWrIghtsok HVAC1MW-01.rup Cale =MJ8 Front Door faces: N 2018-0cIJ0 10:41:17 Page 2 Project umma Job: wrightSoft� S� Data: Oct zs, 2019 Entire House By: For: MW-01 9631 KNOLLWOOD LN, FORT PIERCE, FL 34951 Notes: Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25136 Btuh Structure 24547 Btuh Ducts 4795 Btuh Ducts 8353 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29931 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 31420 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 12578 Btuh Ducts 2259 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ffa) 2507 2507 Equipment latent load 14837 Btuh Volume (ffe) 24389 24389 Air changes/hour 0.22 0.11 Equipment total load 46257 Btuh Equiv. AVF (cfm) 89 45 Req. total capacity at 0.70 SHR 3.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-047-230' AHRI ref Coil CBX27UH-048-230'++TDR AHRI ref 3869174 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.8 kW Sensible cooling 32550 Btuh Heating output 30073 Btuh Latent cooling 13950 Btuh Temperature rise 18 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.052 ofm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wri htsOft zalsonao w:ave1 g ACK RightSuite®Universe1201212.1.05 RSU02818 Pagel C:IUsersUasonwocumentsWdghtsoft HVAMM-01.rup Colo =MJ8 Front Door faces: N GHO HOMES MW-01 9651 KNOLLWOOD LN FORT PIERCE, FL 54951