HomeMy WebLinkAboutBrouillard metal product approvalBusiness &
Professional -
gulation
sas Home Log In i User Registration aot Topics submit Surcharge Stats &Facts
b?r
-
Product Approval
USER: Public User
. i , . P
Plgd6a91211EM% Memo > product or Ap i anon > g Y n '5 > Application Detair
Publications - Contact Us gas; site Map Links f S—th
FL *
FL17022-R7
App9#cation Type
Revision
Code Version
2017
Application Status
Approved
Comments
08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flv a l i d a ti on@ya h o o. co m
Authorized Signature
Richard McKuhen
Rvatidation@yehoo.com
Technical Representative
Richard McKuhen
Address/phone/Email
216U SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfah.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration pate
04/22/2024
Vaiidated By
Zachary R. Priest, P.E.
Validation Checklist - Hardcupy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Epuivaience of Product Standards
Certified By
Sections from the Code
FL17022 R7 COI FL 17022,1 5_V,CRIMP ssr.p�
Standard
TAS 125
UL 1897
UL 580
ymmr
2003
2012
2006
https:llwww.floridabuilding.org/prlpr_app dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 113
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08128/2017
Date Approved 10/10/2017
Summary of Products
fL # -
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (116)
26 Gauge steel, 318" rib height, 24" wide lapped roof panel 7
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ- No
FL17022 R] II FL 17022.1 5 V CRIMP ssr PSUf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, RE. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other. Refer to evaluation report for conditions. Install the
FL17022 R7 AE Fl. JZ022.1CRIMP rp-P
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 I1 FL 17022.2 5 V CRIMP 0,032 ALUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design pressure: +N/A/ -Table A
Evaluation Reports
other: Refer to evaluation report for conditions,Install the
assembly in compliance with the installation method listed
FL17022 R7 AE FL 17022.2 5 V CRIMP 0 032 ALUM_ ssr W
Created by Independent Third Party: Yes
I� in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022,3
3 - "1.5' Mechanical Seam" (115)
1.5" rib height, 16",wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15132" plywood or wood deck
�
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
&170R2 R7 II FL 17022_3 1 5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24ga ssr,pdf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the assembly in compliance with the installation
EL17022 R7 A FL IZQ22.3M9CHANICAL
method listed in this report and applicable code sections of
seam 24ga ssr.pdf
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.4
4 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16' wide, 0.032" aluminum, standing seam roof
panel mechanically attached to 15/32' plyr+ood or Wood Deck
with dips and fasteners.
Limits of Use
installation Instructions
Approved for use in HVHZ: No
EL.17022 RZ-jLFLj7Q?2.4MECF1ANgTAL SEAM
Approved for use outside HVHZ: Yes
-ALUMINUM r pdf
Impact Resistant: No
Design Pressure: +N/A/ Table A
Verified By: Locke Bowden, P.E. 49704
other: Refer to evaluation report for conditions and limitations
Created by Independent Third Party: Yes
Evaluation Reports
of use. Install the assembly in compliance with the installation
17 22 R7 AE FL 17022 SEAM
method fisted in this report and applicable code sections of
;4.MKHANCI6L
ALUMINUM ssrpof
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.5
5 - "1 in. Nail Strip" (R5)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15132" plywood or woad deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.5 1 0 NAIL$TRIP ssr.pd(
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and limitations
https,llwww.foridabuilding.org/prlpr app_dtl-aspx?param--WGEVXQWtDgv2aBQpHpQQe6rMZMkUEoR°/a2bGxHGxFe5QkcHzEgvOQveeg%3d%3d 213
Of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections Of
FBC- Refer to manufacturers installation instructions.
RIM22 R7 AE „FL 17022.5 I,Q NAil sTRIp r., .per
Created by Independent Third Party: Yes
17022.6 h 6 - "1 in. Nail Strip- (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant- No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation Instructions.
17022.7 � 7 - "1.5 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use Outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limltations
of use. Install Cite assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.E 18 - "EMAX Rib" (R5)
Limits of Use -
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other; Refer to evaluation report for conditions and limitations
Of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.9 19 - " PBR MAX" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
i" rib height, 16' wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
installation Instructions
2 R7 Ij FL 17022.61. MIL STRIP 0.032
ALUM ssrg_d,€_
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FLIYD22 R7 AE F1 jZ022.6 1,0 NAILL STR A
ALUM ssr12d
Created by Independent Third Party; Yes
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15132" plywood or wood deck
with fasteners.
Installation Instructions
EL17022 R7_I1, TI. 17022 7 1.5 Nail S rn—ZiE ssr.p-d
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
fl.17022 R7 AE- FL 17022 7 13 Noil Strip25GA ssrf
Created by Independent Third Party: Yes
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
F R FL 177 X Ri Pdf
Verified By: Locke Bowden, P.E. 49704
Created,by Independent Third Party: Yes
Evaluation Reports
FL17022 R7. 70 .0 E A srpdf
Created by Independent Third Party: Yes
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
FL17022 R7 11 FL 170224 PBR RIB css pff
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
F 7 R7 AE FL 1=2.9PBR RIB pgf
Created by Independent Third Party: Yes
Back Next
Con a US :: 2601 &a'C stone Road T ssee 99 Ph 85 -a 7-192
The State of Florida is an AA/tEo employer. S'g 2 -20 of on :; Pdvacv statemwt :: Accessibility Stahel iiefund �tasement
Under Florida law, email addesses are pubrk records. I€ you do not want your it -mail address released in response to a public -records request, do not send electronic
mall to this entity, Instead, contact the office by phone or by traditional marl. If you have any questions, please contact SSOA87.1395. 'Pursuant m Ser.4on 455.275(1),
Florida statutes„ effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis
provided may be used for official communication with the licensea. However emaiF addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which ran be made available to the public. To determine If you are a licensee under ChaPter455, FS., please click hEm
Product Appm"( Accepts:
Own
Credit Card
Safe
https:l/www.floddabuiiding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoRn/o2bGxHGxFe5QkCHzEgvOQveegb/e3d°/a3d 3/3
Palm City, FL 34990
(772)872-8034
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 0.032" Aluminum Roof Panel FBC Sec.1507.4.2
Yield strength: 0.032" Aluminum Min.; Attached to min.15/32"' plywood or
Wood Deck w/min 0.42 specific gravity with screws. 21" Coverage (Max.)
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or
5/8" min embedment into wood plank. (*or of sufficient length to meet requirements)
Underlayment: To be compliant with FBC Sec.1507.1.1
Slope: Shall be in compliance with FBC Sec.1S07.
Install Details: Table A Allowable Loads
DESIGN PRESSURE*
ROW SPACING
METHOD 1
-168.5 PSF
10" O.C.
FASTENER SPACING (ALONG ROWS) 10.51, O.C.
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
U L 580-06 & 1897-041 Test Report D5893.04-450-18 10/24/14
*EQUIVALENCY: UL 1897-041 is equivalent to test standard UL 1897-12.
*DESIGN PRESSURE -MARGIN OF SAFETY 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products
under this evaluation.
11111rrrtri,
Locke Bowden, P.E. is not owned, operated, or controlled by a ate: T�� !! cturer, or distributing products under this
report.
sea f
D •• Srr1T�
Oki
• �'r��I1�1ii'.iig.
Limitations
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities wljurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing compliant w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL17022.2 5V Crimp (0.032" Alum), 21" Wide Roof Panel -Details
Fastener- #9 x 1-112" Minimum
Hex Washer Head Wood Screws 5-V Crimp Roof panel
U'
O'
�O
Isometric View
Dom:-15132" or greater Plywood, or
- Wood plank
21"
10.5"
318"
Panel Overlap
OPTIONAL STRIATIONS
Panel Profile
Nominal 10.5" o.c. I Nominal 10.5' o.c.
Fastener
#9 x 1-1/5" Min.
Hex Washer Head Screw
Spaced 10.5" o.c. across the Panel
Deck:
-15/32" or greater Plywood, or
- Wood plank