Loading...
HomeMy WebLinkAboutBrouillard metal product approvalBusiness & Professional - gulation sas Home Log In i User Registration aot Topics submit Surcharge Stats &Facts b?r - Product Approval USER: Public User . i , . P Plgd6a91211EM% Memo > product or Ap i anon > g Y n '5 > Application Detair Publications - Contact Us gas; site Map Links f S—th FL * FL17022-R7 App9#cation Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flv a l i d a ti on@ya h o o. co m Authorized Signature Richard McKuhen Rvatidation@yehoo.com Technical Representative Richard McKuhen Address/phone/Email 216U SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfah.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration pate 04/22/2024 Vaiidated By Zachary R. Priest, P.E. Validation Checklist - Hardcupy Received Certificate of Independence Referenced Standard and Year (of Standard) Epuivaience of Product Standards Certified By Sections from the Code FL17022 R7 COI FL 17022,1 5_V,CRIMP ssr.p� Standard TAS 125 UL 1897 UL 580 ymmr 2003 2012 2006 https:llwww.floridabuilding.org/prlpr_app dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 113 Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08128/2017 Date Approved 10/10/2017 Summary of Products fL # - Model, Number or Name Description 17022.1 1 - "5V Crimp" (116) 26 Gauge steel, 318" rib height, 24" wide lapped roof panel 7 mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ- No FL17022 R] II FL 17022.1 5 V CRIMP ssr PSUf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, RE. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other. Refer to evaluation report for conditions. Install the FL17022 R7 AE Fl. JZ022.1CRIMP rp-P assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17022 R7 I1 FL 17022.2 5 V CRIMP 0,032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design pressure: +N/A/ -Table A Evaluation Reports other: Refer to evaluation report for conditions,Install the assembly in compliance with the installation method listed FL17022 R7 AE FL 17022.2 5 V CRIMP 0 032 ALUM_ ssr W Created by Independent Third Party: Yes I� in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022,3 3 - "1.5' Mechanical Seam" (115) 1.5" rib height, 16",wide, 24 gauge steel, standing seam roof panel mechanically attached to 15132" plywood or wood deck � with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No &170R2 R7 II FL 17022_3 1 5 MECHANICAL Approved for use outside HVHZ: Yes seam 24ga ssr,pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly in compliance with the installation EL17022 R7 A FL IZQ22.3M9CHANICAL method listed in this report and applicable code sections of seam 24ga ssr.pdf FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.4 4 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16' wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32' plyr+ood or Wood Deck with dips and fasteners. Limits of Use installation Instructions Approved for use in HVHZ: No EL.17022 RZ-jLFLj7Q?2.4MECF1ANgTAL SEAM Approved for use outside HVHZ: Yes -ALUMINUM r pdf Impact Resistant: No Design Pressure: +N/A/ Table A Verified By: Locke Bowden, P.E. 49704 other: Refer to evaluation report for conditions and limitations Created by Independent Third Party: Yes Evaluation Reports of use. Install the assembly in compliance with the installation 17 22 R7 AE FL 17022 SEAM method fisted in this report and applicable code sections of ;4.MKHANCI6L ALUMINUM ssrpof FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.5 5 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15132" plywood or woad deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1 0 NAIL$TRIP ssr.pd( Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations https,llwww.foridabuilding.org/prlpr app_dtl-aspx?param--WGEVXQWtDgv2aBQpHpQQe6rMZMkUEoR°/a2bGxHGxFe5QkcHzEgvOQveeg%3d%3d 213 Of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections Of FBC- Refer to manufacturers installation instructions. RIM22 R7 AE „FL 17022.5 I,Q NAil sTRIp r., .per Created by Independent Third Party: Yes 17022.6 h 6 - "1 in. Nail Strip- (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant- No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.7 � 7 - "1.5 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use Outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limltations of use. Install Cite assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.E 18 - "EMAX Rib" (R5) Limits of Use - Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other; Refer to evaluation report for conditions and limitations Of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 19 - " PBR MAX" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ; Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. i" rib height, 16' wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, installation Instructions 2 R7 Ij FL 17022.61. MIL STRIP 0.032 ALUM ssrg_d,€_ Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FLIYD22 R7 AE F1 jZ022.6 1,0 NAILL STR A ALUM ssr12d Created by Independent Third Party; Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15132" plywood or wood deck with fasteners. Installation Instructions EL17022 R7_I1, TI. 17022 7 1.5 Nail S rn—ZiE ssr.p-d Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports fl.17022 R7 AE- FL 17022 7 13 Noil Strip25GA ssrf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions F R FL 177 X Ri Pdf Verified By: Locke Bowden, P.E. 49704 Created,by Independent Third Party: Yes Evaluation Reports FL17022 R7. 70 .0 E A srpdf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 11 FL 170224 PBR RIB css pff Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports F 7 R7 AE FL 1=2.9PBR RIB pgf Created by Independent Third Party: Yes Back Next Con a US :: 2601 &a'C stone Road T ssee 99 Ph 85 -a 7-192 The State of Florida is an AA/tEo employer. S'g 2 -20 of on :; Pdvacv statemwt :: Accessibility Stahel iiefund �tasement Under Florida law, email addesses are pubrk records. I€ you do not want your it -mail address released in response to a public -records request, do not send electronic mall to this entity, Instead, contact the office by phone or by traditional marl. If you have any questions, please contact SSOA87.1395. 'Pursuant m Ser.4on 455.275(1), Florida statutes„ effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensea. However emaiF addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which ran be made available to the public. To determine If you are a licensee under ChaPter455, FS., please click hEm Product Appm"( Accepts: Own Credit Card Safe https:l/www.floddabuiiding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoRn/o2bGxHGxFe5QkCHzEgvOQveegb/e3d°/a3d 3/3 Palm City, FL 34990 (772)872-8034 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 0.032" Aluminum Roof Panel FBC Sec.1507.4.2 Yield strength: 0.032" Aluminum Min.; Attached to min.15/32"' plywood or Wood Deck w/min 0.42 specific gravity with screws. 21" Coverage (Max.) Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1: #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" min embedment into wood plank. (*or of sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec.1S07. Install Details: Table A Allowable Loads DESIGN PRESSURE* ROW SPACING METHOD 1 -168.5 PSF 10" O.C. FASTENER SPACING (ALONG ROWS) 10.51, O.C. Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 U L 580-06 & 1897-041 Test Report D5893.04-450-18 10/24/14 *EQUIVALENCY: UL 1897-041 is equivalent to test standard UL 1897-12. *DESIGN PRESSURE -MARGIN OF SAFETY 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. 11111rrrtri, Locke Bowden, P.E. is not owned, operated, or controlled by a ate: T�� !! cturer, or distributing products under this report. sea f D •• Srr1T� Oki • �'r��I1�1ii'.iig. Limitations 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wljurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing compliant w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. FL17022.2 5V Crimp (0.032" Alum), 21" Wide Roof Panel -Details Fastener- #9 x 1-112" Minimum Hex Washer Head Wood Screws 5-V Crimp Roof panel U' O' �O Isometric View Dom:-15132" or greater Plywood, or - Wood plank 21" 10.5" 318" Panel Overlap OPTIONAL STRIATIONS Panel Profile Nominal 10.5" o.c. I Nominal 10.5' o.c. Fastener #9 x 1-1/5" Min. Hex Washer Head Screw Spaced 10.5" o.c. across the Panel Deck: -15/32" or greater Plywood, or - Wood plank