Loading...
HomeMy WebLinkAboutTri-Built Underlayment Product Approval"12/2020 Florida Building Code Online K BUIS Home Log In User Registraricn not Tops Submit Surcharge Stals a F.Ux Publications correct Us BCIS Site Mao links Search dbpr 4-ol Product Approval USER: Public User pp Prs&L1AAP II MM ny> Productr Aoyhat onSearch> ASisston Let> Al"llCMIon pawl FL # FL23888-RO Application Type New Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Tri -Built Materials Group, LLC Address/Phone/Email PO Box 70 Rutherford, N] 07070 (800)516-1485 david. raiz@tribuiltmg.com Authorized Signature David Ruiz david.miz@tribuiltmg.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford, N] 07073 (201) 842-2449 david.miz@tribuiltmateriaisgroup.com Quality Assurance Representative C Richard Schurman Address/Phone/Email 9050 Louisiana Street Merrillville, IN 46410 rich.Schuman@alliedbuilding.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R, Priest Evaluation Report 02/12/2018 Florida License PE -74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC. Quality Assurance Contract Expiration Date 01/27/2022 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL23888 RO COI GG118001 2017 FBC Eval Syn Underlayments.odf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/12/2018 Date Validated 02/13/2018 Date Pending FBC Approval 02/19/2018 Date Approved 04/10/2018 https://floHdabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsGBUBaMj WlOxLQXCk2186Fx4a9eDOMyfLl4S9wb/o2bAYgywa/o3d%3d 1/2 3/2/2020 Date Revised Florida Building Code Online 12/20/2019 FL # Model, Number or Name 23888.1 TRI -BUILT® Synthetic Hybrid Roof Underlayment Limits of Use Approved for use in NVN2: Yes Approved for use outside HVHZ: yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Description A mechanically attached, synthetic underlayment used an alternative to ASTM D 226, Type I and Type II roofing underlayments, Installation Instructions FL23888 R0 11 GG138001 2017 FBC Eva[ SynUndenayments pdf Verified By: Zachary R. Priest PE -74021 Created by Independent Third Party: Yes Evaluation Reports FL23888 RO AE • •I18001 2017 FB v I ymLntLpdf Created by Independent Third Party: Yes Concert_r 2601 Blair Stene Road, Tallahaaaee FL 32399 Poops: 850-4B7-3824 The state of Florida is an WEED employe[ Cep ul d: 2007-2013 State of north :: Perry t3atement :; soccessibillbSatement :: afford Statement Under Florida law, email addresses are public records. If you do net want your a -mall address released in response t0 a public -records request, do not send ekctmnic mail to this entity. Instead, Contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.' W rment to Section 455,275(1), Floo de Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. mug provide the Department with an email address If Mey have one. The make proNded may be used for oMclal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made avallable to the public. To determine If you are a licensee under Chapter 455, F.5., please click here. product Approval lleeeprs: Credit Card Safe https:llfloddabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsGBUBaMjWlOxLQXCk2186Fx4a9eDOMyn-i4S9wp/`2bAYgywp/o3dd/p3d 212 CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: TRI -BUILT Materials Group 9050 Louisiana Street Merrillville, IN 46410 (800) 516-1485 www.tribuiltmaterialgrour).com Manufacturing Locations: Hangzhou, China Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, C EDITION Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Issued February 12, 2018 Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies (TST5878) GGI-176-02-01,3 ASTM D 226 2009 ASTM D 1970 2015a PRODUCT DESCRIPTION TRI -BUILT® Synthetic A mechanically attached, synthetic underlayment used an alternative to ASTM D 226, Hybrid Roof Underlayment Type I and Type II roofing underiayments. The roll is available in 37.25 -inch wide x 145 -ft long format and weighs approximately 40 lbs with a minimum tear strength per ASTM D 4533 of 20 pounds. LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Roof slope limitations shall be in accordance with FBC requirements. 6) Contact the manufacturer when installing at temperatures below the minimum application temperature. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 9) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. GG118001 FL23888 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, Installatlon, recommended use, or other product attributes that are not specifically addressed herein. GREEK TECHNICAL SERVICES, LLC APPLICATION INSTRUCTIONS TRI -BUILT MATERIALS GROUP Synthetic Hybrid Roof Underlayment Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. New construction in the HVHZ shall be minimum 19/32 -inch plywood. Roof decks shall have no more than 1/8" gap at abutting joints. Attachment method Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and (Non-HVHZ): manufacturer's installation instructions. Attachment method Underlayment shall be installed with a minimum 4 -inch head lap and minimum 6 -inch (HVHZ): end lap and be fastened as specified in FBC Section 1518.2. Allowable roof coverings Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. (Non-HVHZ): Allowable roof coverings Mechanically attached asphalt shingles, composite shingles, metal roof panels and (HVHZ): shingles, or wood shakes and shingles COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. `�tlllllrrr��, ��P``PFIY R. G E NSF No 74021 2018.02.12 U STATE OF <U 18:48:08 -05'00' �'.. :---�^-- ' <(/ '�4 O R 1 P ` Zachary R. Priest, P.E. 0.- 10NA1— OrganizFlorida ation No. Registration No. 71 21 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product END OF REPORT GG118001 FL23888 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.