HomeMy WebLinkAboutRevision; Column RemovalArchitectonic Inc Project Address: 2412 Shamrock Road, Ft Pierce, FL February 18,2020 RE: Column Removal To Whom It May Concern, RECEIVED FEB 19 373 II ST. Lucie County, Pormlttina Please be advised the removal of the existing CMU column is acceptable, as the roof load carrying capability has been replaced by the new CMU wall running the full length of the span. Contractor shall take necessary measures to support beam in a level horizontal position while pouring the new bond beam up to the bottom of the existing wood beam. Existing wood beam shall be strapped to new CMU wall as per detail in drawings. POUR BOND BEAM TO ENSURE CONTINUOUS AND LEVEL Please co r office with any questions. P ;ipal P�9� Q. BEAM AND BOTTOM OF EXIST WOOD BEAM PROVIDE30# FELT BETWEEN WOOD BEAM AND CONIC. BOND BI5= (1 os -U)5(� REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC RG0FSTIWCTIRE 806 Delaware Avenue Tel: 7724607751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1