HomeMy WebLinkAboutRevision; Column RemovalArchitectonic Inc
Project Address: 2412 Shamrock Road, Ft Pierce, FL
February 18,2020
RE: Column Removal
To Whom It May Concern,
RECEIVED
FEB 19 373 II
ST. Lucie County, Pormlttina
Please be advised the removal of the existing CMU column is acceptable, as the roof load carrying capability has
been replaced by the new CMU wall running the full length of the span. Contractor shall take necessary
measures to support beam in a level horizontal position while pouring the new bond beam up to the bottom of
the existing wood beam. Existing wood beam shall be strapped to new CMU wall as per detail in drawings.
POUR BOND BEAM TO ENSURE
CONTINUOUS AND LEVEL
Please co r office with any questions.
P
;ipal P�9�
Q.
BEAM AND BOTTOM OF
EXIST WOOD BEAM
PROVIDE30# FELT
BETWEEN WOOD BEAM
AND CONIC. BOND BI5=
(1 os -U)5(�
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
RG0FSTIWCTIRE
806 Delaware Avenue Tel: 7724607751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1