HomeMy WebLinkAboutNOA, ShinglesMU4M
DEPARTMENT OF REGULATORY AND
BOARD AND CODE ADMINISTRATION
-NOTICE OF ACCEPTANCE I
TAMKO Building Products, Inc.
220 West 4th Street
Joplin, MO 64801
SCOPE:
This NOA is being issued under the app
documentation submitted has been revie,
used in Miami -Dade County and other ar
This NOA shall not be valid after the exp
(in Miami -Dade County) and/or the AF
product or material tested for quality asp
manner, the manufacturer will incur the
suspend the use of such product or mater
if it is determined by Miami -Dade Cou
requirements of the applicable building c
This product is approved as described
including the High Velocity Hurricane Z
RESOURCES (RER)
N
.W
MIAMI -DARE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
wvw miamidade.eov/economy
,ble rules and regulations governing the use of construction materials. The
and accepted by Miami -Dade County RER -Product Control Section to be
where allowed by the Authority Having Jurisdiction (AHJ).
ation date stated below. The Miami -Dade County Product Control Section
(in areas other than Miami -Dade County) reserve the right to have this
ance ,purposes. if this product or material fails to perform in the accepted
,,pense of such testing and the AHJ may immediately revoke, modify, or
within their jurisdiction. RER reserves the right to revoke this acceptance,
v Product Control Section that this product or material fails to meet the
ein. and has been designed to comply with the Florida Building Code
of the Florida Building Code.
DESCRIPTION: TAMKO Roof Shinglo s
LABELING: Each unit shall bear a perr ianent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Gontrol Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be consired after a renewal application has been filed and there has been no change
in the applicable building code negatively ffecting the performance of this product.
TERMINATION of this NOA will occ r after the expiration date or if there has been a revision or change in the
materials, use, and'or manufacture of the roduct or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purpose shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for terminatior and removal of NOA.
ADVERTISEMENT: The NOA numbe preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in adVeT ising literature. if any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NFA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 15-0709.19
The submitted documentation was revit
APPROYED'
consists of pages I through 6.
by Gaspar J Rodriguez.
!VOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 1 of 6
GREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LL
COMPLIANCE STATEMENT
The products evaluated herein by Zach R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 60 Edition (2017) as evidenced in a referenced documents submitted by the named manufacturer.
%IIlrrlrrrl,
Y R, pI *�i, 2017.10.19
o 74021 12:15:58
* = -04'00'
TATE OF o:44/
0.�'•, Q P .• 441 Zachary R. Priest, P.E.
O R �,. •�(j �.` Florida Registration No. 74021
ONA�-��.`', Organization No. ANE9641
•►rrnr�t���
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, n will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, op ted, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will ac re, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will ac re, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
Page 4 of 4
TBP14001.4 FL12328-R8
This evaluation report is provided for St of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product anges or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express or imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TBP14001.4
This evaluation report is provided for St
Technical Services, LLC of any product
This evaluation report does not express
specifically addressed herein.
Page 3of4
FL12328-R8
-- Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
inges or quality assurance changes throughout the duration for which this report is valid.
r imply warranty, installation, recommended use, or other product attributes that are not
TAMKO BUILDING PRODCUTS, INC.
CREEKTAMKO
Underlayments
TECHNICAL SERVICES, LL
LIMITATIONS
1) Fire Classification is not within t
scope of this evaluation.
2) Wind uplift resistance in not wit
scope of this evaluation.
. ort, the
comply P
FBC, and the manufacturer's published
3) Installation of the evaluated pro
Wher
ct shall
discrepancies exist between these
sources, the more restrictive and FBC
application instructions.
compliant installation detail she
prevail.
at temperatures below the minimum application temperature.
4) Contact the manufacturer whe
5) Unless otherwise stated, the mi
stalling
mum roof slope shall be in accordance
with FBC requirements.
starting at the eave, and lapped
6) All underlayments shall be inst
ed with the roll length parallel to the eave,
the deck in a manner that effectively sheds water from the deck. End
in successive courses installe
p
in accordance with the manufacturer's
applic ion instructions.
n tructions.
laps shall be staggered betwee
courses
described in other current FBC product
approval
7) The underlayment may be use
8) The underlayment shall not be
s
stalled over existing roof coverings.
limits for each
underlayment.
9) Contact the manufacturer rega
ing specific exposure
under a quality
assurance program in compliance with
10) All products listed in this report
hall be manufactured
Rule 61 G20-3.
REFERENCES
Enti
Report No.
Standard Year
ASTM D 1970 2015a
PRI Construction Materials Technologies (T
Construction Materials Technologies (T
6049) TAP -193-02-01
6049)
ASTM D 1970 2015a
ASTM D 4869 2016
PRI
PRI Construction Materials Technologies R
Construction Materials Technologies (T
6049) TAP -214-02-01
6049) TAP-215 02-01
ASTM D 226 2009
ASTM D 6380 2003(2013)
PRI
PRI Construction Materials Technologies (T
6049) TAP -216-02-03
TAP -217-02-01 REV
ASTM D 6380 20G3(2013)
PRI Construction Materials Technologies (T
Materials Technologies (T
6049)
6049) TAP -218-02-01
ASTM D 226 2009
ASTM D 226 2009
PRI Construction
PRI Construction Materials Technologies (T
6049) TAP -219-02-01
TAP -220-02-01
ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (T
6049)
6049) TAP-222-02-0
ASTM D 4869 2016
19951
PRI Construction Materials Technologies (T
Materials Technologies (
6049) TAP -245-02-01
TAS 103
ASTM D 4798 2011
PRI Construction
PRI Construction Materials Technologies (
T6049) TAP -311-02-01
1
ASTM D 1970 2011
ACC 188 2012
_
PRI Construction Materials Technologies
Materials Technologies (
T6049) TAP -387-02-01
T6049)
2015a
ASTM D 1970 2015a
ASTM D 1970
PRI Construction
PRI Construction Materials Technologies (
T6049) TAP -388-02-01
13CA12269
ASTM D 226 2009
UL LLC (TST9628)
TBP14001.4
This evaluation report is provided for St
Technical Services, LLC of any product
This evaluation report does not express
specifically addressed herein.
Page 3of4
FL12328-R8
-- Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
inges or quality assurance changes throughout the duration for which this report is valid.
r imply warranty, installation, recommended use, or other product attributes that are not
CREEK
TECHNICAL SERVICES, LLI
TAMKOO TAM -FELT Alternate
t
perforated (
APPLICATION METHOD
Installation shall be in accordance wit
requirements below.
Deck substrates shall be clean, dry, ar
checked for protrusion and corrected pr
The roof deck shall be constructed of cl
shall be installed in accordance with F
joints.
The minimum application temperature
a) The minimum application
Underlayment shall be 4C
b) The minimum application
The minimum roof slope shall be in as
a) The minimum slope of TI
Undedayments shall be exposed in
exposure exceed 30 days.
Exception: TAMKO® TW Me
Self -adhering undedayments may be
All roof coverings shall be mechanica
TAMKO BUI TAMK UODCUTS. INC.
nderlayment
3TM D 226, Type I and Type II underiayment constructed from a non-
anic felt that is saturated with asphalt.
the published manufacturer's installation mstrucnons, uiv
and
free from any irregularities and debris. All fasteners in the deck shall be
to underlayment application.
ely fitted plywood sheathing for new or existing construction. Plywood abutting
requirements. Roof decks shall have no more than 118" gap
I be 50°F except as follows:
iperature of TAMKOO TW Metal and Tile Underlayment and TAMKO® TW
1perature of TAMKO® Moisture Guard® shall be 35°F.
lance with FBC requirements except as follows:
:O® ASTM Slate Surfaced Roll Roofing shall be 2:12.
ordance with the manufacturer's recommendations, but in no case shall
and Tile Underlayment may be exposed for a maximum 90 days.
ered to primed or unprimed plywood substrates in the non-HVHZ.
astened through the underayment to the roof deck.
Allowable Roof Coverings:
Metal Roof
Panels and
Mineral
Surfaced Roll
Wood
Shing les and
State Clay and
Shln les Concrete Tile
As
shi
alt
les Shin les
Roofs
Shakes
Y
Unded ent
N
N
N
TAMKO® ASTM Slate
N
Surfaced Roll Roofing
N
N Y
TAMKO® ASTM Tile
N
N
Underlayment
N
N N
TAMKO® Master Smooth
� N
N
N
N
N
N
N
TAMKO® Moisture Guard®
TAM KOO No. 15 ASTM
Y
Y
Y2
N N
Asphalt Saturated Organic
Felt
TAMKOO No. 15 UL Asphalt
Y
Y
Yz
Y N
Saturated Organic Felt
Y
TAMKOraI No. 30 ASTM
Y
Y
Y
Y
Asphalt Saturated Organic
Y
Felt
TAMKO® No. 30 UL Asphalt
Y Y
Y
N
Y N
Saturated Organic Felt
N Y
TAMKO® TW Metal and Tile
Y Y
N
N
underlayment
N
N
N N
TAMKO® TW Underlayment
Y Y
N
Y N
N
N
N
TAMKO® TAM -FELT
Notes: a p
1507.2.9.2
oshingles onlyalley
2; Wod Wood
Page 2 of 4
TBP14001.4
This evaluation report is provided for S
FL12328-R8
royal under Rule 61 G20-3. The manufacturer shall noYrfy CREEK
changes throughout the duration for which this report is valid.
e of Florida product app
that are not
Technical Services, LLC of any produc
hanges or quality assurance
or imply warranty,
installation, recommended
use,
or other product attributes
This evaluation report does not expres
specifically addressed herein.
ROOFING ASSEMBLY APPROVAL
Cate2orv:
Roofing
Sub-Cateeorv:
Asphalt Shingle
Materials:
Laminate
Deck Tvae:
Wood
SCOPE
This approves TAMKO's Heritage, He
T.-kMKO Building Products, Inc., as d
Building Code High Velocity Hurricane
PRODUCT DESCRIPTION
Product
Heritage
Manufacturing Location # 1, 2, 3
Heritage Woodgate
Manufacturing Location # 1.3
Heritage Premium
Manufacturing Location # 1. 2, 3
MANUFACTURING LOCATIONS
1. Dallas, TX
Tuscaloosa, AL
3. Frederick, MD
EVIDENCE SUBMITTED
Test Asencv
Underwriters Laboratories, Inc.
I'RJ Asphalt Technologies, Inc.
Woodgate and Heritage Premium asphalt shingles, manufactured by
d in this Notice of Acceptance and designed to comply with the Florida
13111/" x 39 ' s"
13111/4" x 39 = s"
131 1/4' x 39 ',s"
PRI Construction Materials Technologies
Test Product Description
Saecifications
TAS 110 Dimensional asphalt shingle.
TAS 1.10 Dimensional asphalt shingle.
TAS 110 Dimensional asphalt shingle.
Test Identifier
Test Name/Resort
Date
TAS 107 & UL 790
04CA44252
02/25/05
ASTM D3462
02NK33813
09/23/02
ASTM D 3462 & TAS 107
82919 Letter
03/10/11
ASTM D3462
4789110543
08/26/14
TAS 107
02/19/15
ASTM L- 108
08/26/14
ASTM D3161, Class F
4787043752
10/20/15
TAS 100
1'AP-129-02-01
05/26/05
TAS 100
TAP -130-02-01
05/26/05
TAS 100
TAP -131-02-01
05/26/05
TAS 100
TAP -303-02-01
12/12/14
TAS 100
TAP -307-02-01
02/10/15
TAS 100
TAP -317-02-01
09/02/15
NOA No.: 15-1215.10
MIAMI•DADE COUNT? Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 2 of 6
LIMITATIONS
1. Fire classification is not part of
fire ratings of this product.
2. Shingles shall not be installed on
3. All products listed herein shall 1
and Rule 61 G20-3 of the Florida
INSTALLATION
1. Shingles shall be installed in comp
2. Flashing shall be in accordance wi-
3. The manufacturer shall provide cle
4. Exposure and course layout shall 1
5. Nailing shall be in compliance wit
LABELING
Shingles shall be permanently
manufacturing facility, and the fo
the Miami -Dade County Product i
BUILDING PERMIT REQUIREMEN
As required by the Building Offici
installation of this system. This N
APPROVED
acceptance; refer to a current Approved Roofing Materials Directory for
mean heights in excess of 33 ft.
a quality assurance audit in accordance with the Florida Building Code
inistrative Code.
ince with Roofing Application Standard RAS 115.
Roofing Application Standard RAS 115.
rly written application instructions.
in compliance with Detail 'A', attached.
Details 'B', attached.
)eled with the manufacturer's name and, or logo, city and state of
ving statement: "Miami -Dade County Product Control Approved" or with
itrol Seal as seen below:
CMLA•DAD E CCOUNTY
...0
or the applicable Building Code in order to properly evaluate the
ice of Acceptance on its own cannot be used to obtain a building permit.
NOA tio.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 3 of 6
DETAIL A
HERITAGE, HERIT GE WOODGATE, AND HERITAGE PREMIUM
All dimensions are in inches.
5TH COURSE
4TH COURSE
-
____ 3RD COURSE
2ND COURSE
23
1ST COURSE
— 29 — --
Full
DETAIL B
HERITAGE SHINGLE
1G. I FASTENING PATTERN
All c imensions are in inches
nf. nlnn
7 3/s"
-- -- -
----------.. ----------------
-!!M—
NOA
--------------
-----------------------
6-1 /8" lExposure
I - -- .=
No.: 15-1215.10
MIAMI-DADE COIRdTY Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 4 of 6
TAIL B (CONTINUED)
1HERITAGE SHINGLE
FIG. 2L TERNA TE FAs TENING PATTERN
M C�)mmon Bond
F STENERS
A
. . . . . . . . . . . . . ........... . . . . . . . .
m
7
X
HERITAGE SHINGLE
(TUSCALOOSA, AL)
FIG.3 LTERNATEFASTENING PATTERN
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG. I OR FIG. 2.
VERTICAL NAIL SP, LCING ALLOWED ANYWHERE WITHIN NAIL ZONE.
PAINT
LINE,
7-7f8"
ACCEPTABLE
FASTENER LOCATION
1-1Q0 NOT FASTEN
ALONG
BOND COMMON BONOD
PREFERRED
FASTENER
LOCATION
JAPPROVED
. LZONE
_]--EDIGE OF
Bim[
ag�
BOND
EXPOSURE
5-5184
NOA No.: 15-1215-10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 5 of 6
HERITAGE WOO�GATE & HERITAGE PREMIUM SHINGLES
G. 4 FASTENING PATTERN
All dimensions are in inches
39-3/8"
7 '/2" 6; 9 3!s 6 '/- 7
1 ..............-------
y
6" 1
I _
E7II) OF THIS ACCEPTANCE
MIAMNDADE COUNTY
13-11'4"
i
Exposure
1�
PT
NOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 6 of 6