HomeMy WebLinkAboutConstruction PlansSCOPE OF WORK CONSTRUCT NEW POLE BARN PER PLAN. - NOTE: ALL CONSTRUCTION MUST COMPLY WITH THE FBC 17, AND THE FBC 17 RESIDENTIAL, 2017 PLUMBING CODE, 2017 MECHANICAL CODE AND THE NEC (NFPA 70) 2014 EDITION. a NOTES: -THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE Building Department Product Approval Submittal Affidavit Permit # Building Address: SEE PLAN Contractor: TBD Product Model # Manufacturer Attachment Method Type Spacing, Embedment & Stiffener etc. Building Design Pressure Product Design Pressure Roof FL# 10124.1 SHINGLES ASPHALT ROOF SHINGLES GAF N/A ROOFING NAILS PER FBC1507.2.6/FRC905.2 (MIN. 6 PER SHINGLE) 61.1 Vult: 194 mph I have reviewed the above product approval information and approve it. Name: Paul Welch P.E. Certification Number: 29945 i1 c Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: POLE BARN Project Address: 7200 SHANAS TRAIL Permit #: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Additio o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that aooly) 1. DESIGN CODE: Florida Building Code 2017 6th Edition with 20_Supplements using ASCE 7-11 2. Structure Designed as (check one): X Enclosed Partially Enclosed _ Open 3. Risk Category; X 1 11 III IV Exposure Category: X B C D 4, Design Wind Velocity 150 mph 116 Aso N/A LRFD End Zone Width: 5 It S. Mean Roof Height: 10 tt Roof Pitch: t :12 Parapet: N/A It 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openin 16.0 16.0 16.0 Zone 4: 24.2 Zone 5: 24.2 N/A Zone 1: 24 2 Zone 2: 40 6 Zone 3: -61.1 26 2 32 4 Garage: N/A 7. Design Loads: Floor N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony: _ N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10, Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Ye DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. 29945 / 5115 ON PLAN 3/19/20 Signature, Date, and Seal Print Name Cart # & Co. Cert Auth. Paul Welch Inc. 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address • .i L.L. q �1 s ( w CD L'U V) 2005 -coy REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY SOCC PWA 001'/ ��r�+/ �'+p.�p yj�r�''+ SHEET NUMBER X-A ME'CHANIC,4L ELECTRICAL C/VIL S'NG/NEER1NG 984 S. yy, SILTMOREST. SUITF_ # I f4f PORTST. LUCIE, FL 34984 f PHONE (772) 7.85. 9888 EMAIL f KIE'LCHINCOAOL. COM PAUL LYELCH, P.E. FL A R-1�'G NO. 29945 COPY - TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL CONNECTOR CONNECTOR FASTENERS NOTES UPLIFT ID UPLIFT DESIGN A-1 EACH 768 (1)- MTS 16 1000 (14)-10d X 1 1/2" g_1 768 (1) MTS 16 1000 (14)-10d X 1 1/2" ;CH TRUSS COMPANY LAYOUT DATE 4 28 20 CUT -SHEET DATE 4 28 20 NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED. TRUSS NOTES: 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. 2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) CONTRACTOR TO VERIFY ALL EXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE -ORDERING, AND INSTALLING TRUSSES. 4) TRUSS TO TRUSSCONNECTIONSTOBEPROVIDEDBYTRUSS COMPANY. 5) SEE TRUSS CONNECTOR SCH.FORTRUSSTOWALLCONNECTIONS. OPIL1 VeL 2x12'i "AM AWED - I I�IAILEV W1 IOJ WAJLS Imo" 1'IL E rao--LNFP 0LJT---0 V_ rem 49 0" - - - �I I I I� i I� II I�iii®liiili 00 i. Lu b u Ln eiL aN PL QT>A-r 11=Ill o (si __ _T T1 = 11 �i11,=•1 ' l fe1ZAD I111' lil fJ Ili do (e) $ ") " all k: `-- 11111 0