HomeMy WebLinkAboutCompaction TestGRNA,&
Port St Luck
FSPE CA # 4930
607 NW Cmnmodiry Cove
Port St Lucie, FL 34986
Phone: 772-92435751 Fax: M924-3580
Soil Nuclear Gauge
Report Date: 6/17/2020
Test Method: ASTM D 6938
Client:
Mel -Ry Construction
10967 South Ocean Drive
Jensen Beach, FL 34957
18-8403.00
Mel -Ry Construction Master Agreement 2018-
2019
Various Locarions
FL
` 9NN KEN ''%,
,'• L\CENSE'•.• �
o 6321 � +S
tient, AE OF ✓ ti, -Z
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1
Test Results
Test#
Optimum Maximum In Place
Retest Test Soil Moisture Dry Density Moisture
Of Date ProctorlD Method Classification (%) (P %)
In Place Probe
Dry Density Depth
Pc in
Min/Max
Percent Comp.
Compaction (%)
Remark
35
6/16/20 8508 D1557 N/A 11.5 111.6 12.1
109.4
12
98 95/105
Pass
36
6/16/20 8508 D1557 N/A 11.5 111.6 11.8
109.9
12
98 95/105
Pass
37
6/16/20 8508 D1557 N/A 11.5 111.6 11.9
109.0
12
98 95/105
Pass
38
6/16/20 8508 D1557 N/A 11.5 111.6 11.8
109.4
12
98 951105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SNI Calibrated
Field Technician
35
Below Bottom of Footing: 2151 Nettles Boulevard, Jensen Beach, Stem Wall Footings,
West Side at Center.
0-1'
Troxier / T3430 / 25092 /
Fevrius, Carlo
36
Below Bottom of Fooling: 2151 Nettles Boulevard, Jensen Beach, Stem Wali Footings,
North Side at Center.
0-1'
Troxler / T3430 / 25092 /
Fevrius, Carlo
37
Below Bottom of Footing: 2151 Nettles Boulevard, Jensen Beach, Stem Wall Footings,
East Side at Center.
0-1
Troxier / T3430 125092 /
Fevrius, Carlo
38
Below Bottom of Footing: 2151 Nettles Boulevard, Jensen Beach, Stem Wall Footings,
South Side at Center.
0-1'
Troxler / T3430 / 25092 /
Fevrius, Carlo
Remarks
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
` 9NN KEN ''%,
,'• L\CENSE'•.• �
o 6321 � +S
tient, AE OF ✓ ti, -Z
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1