Loading...
HomeMy WebLinkAboutTU Plus UnderlaymentFlorida Building Code Online Page 1 of 2 Professional W60 SCIS Home I Log in I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I contact us I SCIS Site Map I Links ! Search F ,l itr{7 Robert Nleminen Product Approval rO USER: Public User PE -59166 (J4gllW,JyWMVj LM= > Product or Auollca[Ion egarch > Aonllcatlon Ust > bnhcation Htstery > Applicatlon Detail FIL IF -5259-R28 ` Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W, Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext 242 malpert@polyglass,com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912)429-8610 MAIpert@polyglass.com Quality Assurance Representative Arlel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 ALender@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer I I Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W, Knezevlch, PE I Validation Checklist - Hardcopy Received CertlFlcate of Independence FL525 ftZ _C9Z�i.0.1.� 01..[QLN1E€ it .Flti,f1.cif Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk... 4/15/2020 Florida Building Code Online Egjlvalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FSC Approval 01/30/2018 Date Approved 04/10/2018 Date Revised 10/15/2019 Surnma of Products Page 2 of 2 �L # Mo del, Number or Name Descriptioniption 5259,1 Polyglass Roof Roofing underlayments Underlayments Llmlts of Use Installation Instructions Approved for use in HVHZ: No ✓ l-5225 R2R IT 7DIR 01 FINAL ER POiYGLAS5I,INE]ERLALnjl5j-L5259-- R28.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nleminen PE -59166 Design Pressure: +N/A/ -622.5 Created by Independent Third Party: Yes Others 1.) The design pressure In this Evaluation Reports application relates to one particular f ;�n_f3 ft tiE?01 01 FINAL ER POLYG SS NMLAYMENTS FL5259- R28.odf underlayment system (over concrete deck) for use under foam -on the systems (where Created by Independent Third Party: Yes the underlayment forms part of the load - path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other Ilmlts of use. Contact Us:: M01 Blair Sic glt Roo b, Inlialio149r, EL3234 Phoned 1150.487-1824 The State of Florida Is an AA/EEO employer. Coavrlaht 20074013 Slate of Florida.:: Privacy Statement i t Acresslbthly Statement ;; Refund Statement under Florida law, on+atl addresses are public records. If you do not wont your a•ma II address rakosed In rosponua to a pubilcrecords request, do not send electronic mall to this entity. instead, cuntacl Lhe orflce by phme or by traditional mail. If you have any queetlons, please enntact 654.487.1395. 'Pursue nt to Section 455.275 (1), Florida Statures, effective October 1, 2412, ilcen"ei ilrenaed undar Chapter 455, F,S, must provide the nepartment with an email a4drasi It they have aha. The on ells provided may be used for offleAt cnmmuntcatlon with the kcansee. However email addresses are public record, If you do not with to supply a personal address, dsase provide She Department with an small address which can be meds available to the put!Ic, To determine If you are a licensee under Chapter 455, F,S„ please click DNL. Product Approval Accepts WNo IR E Credit Card Safe http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk... 4/15/2020 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 MEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 CERTIFY Evaluation Report P12060.02.09 -R24 FL5259-R28 Date of Issuance: 02/24/2009 Revision 24: 01/24/2018 SCOPE: This Evaluation Report is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials In the State of Florida. The documentation submitted has been reviewed by Robert Nleminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed In advertising literature. If any portion of the Evaluation Report Is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or Its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: i�1++?�err;l+rsy Robert J.M. Nieminen P.E. & The facslmlle seal appearing was authorized by Robert Nleminen, Florida Reglstratlon No. 59-66, Florida DCA ANE1983 P.E. on 01/24/2018. This does not serve as an electronically signed document, CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does It Intend to acquire or will It acquire, a financial interest In any company manufacturing or distributing products It evaluates. 2. NEMOI etc. Is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nleminen, P,E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E, does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW I etc. nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION; 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compl)ance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRI01111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033.02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RXI4ESA 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09 -R1 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10,11 10/19/2011 NEMO ETC, I.I.C. Evaluation Report P12060.02.09 -R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVH2 EVALUATION FLSZS9-RIB Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 2 of 14 Entity ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ICC -ES (EVL 2396) Miami -Dade (CER 1552) Polyglass USA Polyglass USA Polyglass USA UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: Examination Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physical Properties Physical Properties IBC Compliance HVHZ Compliance Manufacturing Affidavit P/L Affidavlt Materials Affidavit Quality Control Reference P40390.08.12-1 P40390.08.12-2 C41420.09.12-3 P39680.03.13 P45370.04,13 P1738.02.07 -R2 11757.04.01-1-R1 P41630.08.13 P11751.05.03 -R1 P11781.11.03 -R1 P45270,05,14 6020.07.14-1 6020.09.14-2 6020.09,14-3 6020.09.14-4 6020.09.14-5 6020.09.14-6 P46520.10.14 P43290.10.14 PLYG-SC7550.03.15 P40390.04.15 P44360.10.14 -R1 PLYG-SC8080.05.15-1 PLYG-SC8905.05.16-1 PLYG-SC8080.07.16 PLYG-SC12025.10.16 PLYG-SC13040,12.16 PLYG-SC11900.03.17 PLYG-SC12115.08.17 ESR -1697 NOA 14-0717.08 Products Current Mule -Hide Cross Ltg Polystick SA Compound Service Confirmation *NEMOletc. Date 08/06/2012 08/07/2012 09/11/2012 03/04/2013 04/26/2013 04/29/2013 04/30/2013 08/06/2013 11/26/2013 11/26/2013 05/12/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 10/03/2014 10/17/2014 03/24/2015 04/03/2015 05/18/2015 05/20/2015 05/17/2016 07/16/2016 10/12/2016 12/27/2016 03/10/2017 08/08/2017 11/01/2014 01/22/2015 02/18/2009 03/01/2008 08/18/2011 Exp. 10/05/2018 4.1 Mechanically Fastened Underlayrnents: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2 Self-Adhering-Underlayments: 4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60 -mil thick rubberized asphalt waterproofing membrane, glass fiber reWorced, surfaced with polyolefinic film surface; meets FRSA/TRI April 2012. 4.2.2 Polystick IR -Xe is a nominal 60 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80 -mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, LLC. Evaluatlon Report P12060.02.09 -R24 certificate of Authorization #32455 GTI EDITION 12017) FOC NON-HVHZ EVALUATION FL52S9-R28 Polyglass Roof Underlayments; (954) 233-1230 Revlslon 24:01/24/2018 Page 3 of 14 OMEMO I etc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/mz polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Pro'" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.8 Polystick Tile Pro'"' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3 Mechanlcally Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen the underlayment composed of a sand-surfaced SBS modified oltumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) In the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems, 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex 56 G and Elastoflex 56 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex 56 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex 6 and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" In the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P,E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification Is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass 3oof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Havlrig Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC, I.I.C. Evaluatlon Report P12060.02.09-1124 certificate of Authorization #37455 6TM EDITION (2017) FOC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 4 of 14 ONEMOjetc. 5.5 Allowabie Roof Covers: 5.5.1 "Foam -on Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Adhesive TABLE 1: ROOF COVER OPTIONS Underlayments Approval Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes jBase Sheet In 2 -ply system) Yes (Base Sheet In 2 -ply system) Yes Yes Yes Elastobase P I Yes Yes (Base Sheet In 2-13IV system) Yes (Base Sheet In 2 -ply system) yes Yes Yes Polyglass G2 Base No s (Base Sheet net -ply system) Yes (Base Sheet In 2 -ply system) NO NO NO Polyglass APP Base No Yes (ease Sheet In 2. ply systaml Yes (Base Sheet In 2-plv systeml No No No PolVstick MTS or MTS PLUS Yes Yes No Yes Yes Yes PolVstick IR -Xe Yes No No No Yes Yes Polystick TU P No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Polystick MU -X Yes Yes Yes (See 5.5,1) Yes Yes Yes Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5,1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) Yes Yes Yes (See 5.5, 1) No Yes Yes 5.5.1 "Foam -on Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Adhesive Florida Product Underlayments Approval DAP Foam Touch 'n Seal Storm Bond Roof FL14506 Polystick TU Plus, Polystick TU Max Tile Adhesive Dow TileBond•" FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH -160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyse ® RTA -1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide 5A -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR) ' Refer to Tile Manufacturer's orAdheslve Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09 -R24 Certificate of Authorization #82155 6tH EDITION (2017) FBC NON-HVHZ EVALUATION F1.5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revlslon 24: 01/24/2016 Page 5 of 14 ONEMOJetc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Polystick lall variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) self -adhered to: ➢ New u-itreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (desigred and installed to meet wind loads for project). Note: Polyglass does not require prlming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR In hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick lall variations), Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polylsocyan u rate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: D ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For instal ation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installatlons under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Lave : Polystick lall variations), Polyflex SAP or SAP FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR In hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch-applled to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For Installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For Installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEMO ETC, LLC. Evaluatlon Report P12060.02.09 -R24 Certiftate oJAuthorliatlon #324_`5 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 2334230 Revision 24: 01/24/2018 Page 6 of 14 NNEMOletc. 5.6.4 Wind Resistance for Underlayment 5vsterns In Foam Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on the systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed In FRSA/TRI April 2012 (04-12) and are used in foam-on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Degign Pressure = -90 DO: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self-adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR), self-adhered. #2 Maximum Design Pressure = -97.5 Psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self-adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR), self-adhered and back-nailed within the selvedge-edge side laps using 12 ga. x 1'/," ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-Inch o.c. #3 MaxiM.0 QMIR Pressure = -105 Dsf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self-adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR), self-adhered and back-nalled within the selvedge-edge side laps using 12 ga, x 1'/." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o,c, #4 Maximum Design Pressure = -135 Dsf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self-adhered. Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR), self-adhered. #5 Maximum Design Pressure = -315 Ds #: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self-adhered. Underlayrrent: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR), self-adhered. #6 Maximum DesiPn Pressure = -622.5 Ds#: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction, Primer: PG100 or ASTM D41 Underlayrrent: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #7 Maximum Deslpn Pressure _=_-30.0 psf*: Deck: Min. 15/32 -Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25 -Inch long x 1 -Inch head diameter round metal cap nails Spacing: 6 -Inch o,c. at the 3 -Inch wide side laps and 6 -Inch o,c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayrr ent: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered. NEMO ETC, U.C. Evaluation Report P12060.02.09 -R24 Certificate of Authorltatlon #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FLSZS9-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 7 of 14 ONEMOletc. #8 Maximum Design Pressure = -37.5_psf*: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheer: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25 -inch long x 1 -inch head diameter round metal cap nails Spacing: 6 -Inch o.c. at the 3 -Inch wide side laps and 6 -Inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered. 49 _Maximum Design Pressure = -37.5 psf*: Deck: Min, 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25 -inch long x 1 -Inch head diameter round metal cap nails Spacing: 6 -Inch o.c, at the 3 -Inch wide side laps and 12 -Inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt. #SO Maximum Design Pressure = -45 Dsf*: Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type 11 felt Fasteners: 11 ga. x 1.25 -inch x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -Inch diameter tin caps Spacing: 4 -inch o.c, at the 2 -Inch wide side laps and 4 -inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt. #11 Max1murn Design Pressure = -45 psf": Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25 -Inch long x 3/8 -Inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tin caps Spacing: 9 -Inch o.c. at the 2 -Inch wide side laps and 9 -Inch o.c. at two (2) equally spaced staggered center rows, Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayrrent: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #12 Maximum Design Pressure = -45 12s#: Deck: Min, 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -flim surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9 -Inch o.c. at the 2 -Inch wide side laps and 18 -Inch o,c, at two (2) equally spaced staggered center rows. Underlayrr ent: Elastoflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #13 Maximum DesIgn Pressure = -52.5 sf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9 -inch o.c. at the 2 -Inch wide side laps and 12 -inch o.c. at two (2) equally spaced staggered center rows. Underlayrrent: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Deslgn_Pressu_re = -52,5 psf: Deck: Min, 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6 -inch o.c. at the 3 -Inch wide side laps and 6 -Inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayrrent: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered. NEMO ETC, LLC. Evaluation Report P12060.02.09 -R24 Certificate of Authorization #324.55 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Palyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 8 of 14 ONEMOJetc. #15 Maximo Design Pressure=-52.5psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6 -Inch o.c. at the 3 -Inch wide side laps and 6 -Inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch-applled. #16 Maximum Design Pressure _60 p0: Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Shee-: Elastobase (sanded top surface for hot -asphalt or torch-applled cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25 -inch long x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -Inch diameter tin caps Spacing: 8 -Inch o.c. at the 4 -inch wide side laps and 8 -inch o.c. at three (3) equally spaced staggered center rows, Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #17 Maximum Design Pressure = -60 psf: Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrlp with OMG Flat Bottom Metal Plates Spacing: 12 -Inch o.c. at the 4 -Inch wide side laps and 12 -Inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch-applled. #18 Maximum Design Pressure = -67.5psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Shee-: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: 12 ga. x 1.25 -inch long x 3/8 -Inch head diameter annular ring shank roofing nails at 1 -5/8 -Inch diameter tin caps Spacing: 8 -Inch o.c. at the 4 -Inch wide side laps and 8 -Inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applled or Polyflex G, torch - applied. 419 Maximum Design Pressure = -75 sf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheer: Polyglass G2 Base or Polyglass APP Base (requires use oftorch-applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrlp 414 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -Inch Insulation Plates or Simplex MARX Cap Fasteners Spacing: 10 -Inch o.c. at the 4 -Inch wide side laps and 10 -Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or torch-applled or Polyflex G, torch - applied. #20 Maximum Design Pressure = -90 nsf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch-applled cap or poly-fllm surface for torch-applled cap) Fasteners: Simplex MARX Cap Fasteners Spacing: 6 -inch o.c. at the 2 -inch wide side laps and 6 -inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch-applled. #21 MaxlmuiTt Design Pressure = -90 psf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch-applled cap or poly -flim surface for torch-applled cap) Fasteners: CMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6 -Inch o.c, at the 4 -Inch wide side laps and 6 -Inch o.c. at three (3) equally spaced staggered center rows, Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. 422 Maxim urn Design Pressure = -90 psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6 -Inch o.c, at the 4 -Inch wide side laps and 6 -Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt, NEMO ETC, U.C. Evaluation Report P12060.02.09 -R24 Certlfcate of Authorization #31435 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 9 of 14 ONEMOletc. #23 Maximuni. Design Press = -90 Psf: Deck: Mln.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3 -Inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9 -Inch o.c. at the 4 -Inch wide side laps and 9 -inch o,c. at four (4) equally spaced staggered center rows. Underlayrrent: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #24 Maximum Desi n Pressure = -97.5 sf: Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25 -Inch x 3/8 -Inch head diameter annular ring shank roofing nails at 1 -5/8 -inch diameter tln caps Spacing: 4 -Inch o.c. at the 4 -Inch wide side laps and 4 -Inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayrrent: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered. #25 Maximum Design Pressure = -105 Dsf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6 -Inch o.c. at the 2 -inch wide side laps and 6 -Inch o.c. at three (3) equally spaced staggered center rows. Underlayrr ent: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied, #26 -Maximum Design Pressure = -112.5 psf: Deck: Min. 19/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25 -Inch x 3/8 -inch head diameter annular ring shank roofing nails at 1 -5/8 -Inch diameter tln caps Spacing: 6 -Inch o.c. at the 4 -Inch wide side laps and 6 -Inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered Underlayrr ent: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet and Mule -Hide SA -APP Cap Sheet (FR), self -adhered. #27 Max+mum DesiRn Pressure = -120 psf: Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrlp or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6 -inch o.c. at the 4 -Inch wide side laps and 6 -Inch o,c. at five (5) equally spaced staggered center rows. Underlayrrent: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #28 _Maximum Design Pressure = 420 psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6 -Inch o.c. at the 4 -inch wide side laps and 6 -Inch o.c. at five (5) equally spaced staggered center rows. Underlayrrent: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC. Evaluation Report P12060,02.09 -R24 Certificate of Authorization #32435 67H EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 10 of 14 ONEMO I etc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30 -days after installation. Polystick IR -Xe or Polystick MU -X shall not be left exposed for longer than 90 -days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180 -days after installation. Polyflex SAP or SAP FR, or Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex 56 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering Is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU -X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt In a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. 5.9 Tile Slippage Limitations (FRSA/TRI Aprll 2012 (04-12)): When loading roof tiles on the underiayment in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Elastoflex G TU Elastoflex S6 G or S6 G FR Tile Profile Staging Method Maximum Slope Flat 10 -tile stack 7:12 Lugged 8 -tile stack (6 over 2) 6;12 Flat or Lugged 6-tlle stack (4 over 2) 4;12 Polystick MTS or MTS PLUS Flat 6 -tile stack (4 over 2) 5;12 Lugged 6 -tile stack (4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6 -tile stack (4 over 2) 7:12 Polystick TU Max Flat 6 -tile stack (4 over 2) or 10 -tile stack 7:12 Lugged 6-tlle stack (4 over 2) 7;12 Lugged 10 -tile stack 6:12 Polystick TU P Flat 6-tlle stack (4 over 2) 6:12 Lugged 6-tlle stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6 -tile stack (4 over 2) 7:12 Flat or Lugged 10 -tile stack 6:12 Polyflex G or G FR Flat or Lugged 6 -tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6 -tile stack (4 over 2) 4:12 NEMO ETC, LLC. Evaluation Report P12060,02.09 -R24 Certificate of Authorization x32455 6'H EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954)133-1230 Revision 24: 01/24/2018 Page 11 of 14 ONEMOJetc. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nall Base: 6.3.1 Non -Tile Roallcatlons: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR In hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile A Ilcations: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. 6.4 Polystick MTS, MTS PLUS, IR -Xe, TU' P, TU PIUS„ TU Mex,MualPro, Tile Pro or MU -X or Polyflex SAP, Polyflex SAP FR, Mule -Hide SA -APP Cap Sheet or Mule -Hide SA -APP Cap Sheet (FR): 6.4.1 Shall be Installed In compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment In FBC Table 1507.1,1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA -APP Cap Sheet or SA -APP Cap Sheet (FR) should be back -nailed In selvage edge seam in accordance with Polyglass / Mule - Hide back nailing guidelines. Nalls shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1 -inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, In area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 Ib. hand roller to ensure full contact and adhesion. for Dual Pro and Tile Pro, align 'the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric), View of ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6 -Inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied In between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used In any exposed application such as crickets, exposed valleys, or exposed roof to wall details NEMO ETC, I.I.C. Evaluation Report P12060.02.09 -R24 certificate of Authorization #32455 6'" EDITION (2017) FBC NON-HVH2 EVALUATION FLSZS9-R28 Polyglass Roof Underlayments; 1954) 233-1230 Revlslon 24:01/24/2018 Page 12 of 14 *NEMOletc. Repair of Polystick membranes Is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled In place over the repair area. Patch laps, if needed, shall be installed In a water shedding manner. All Polystick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 Ib roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tiie Applications t'rrot allowed for Polystick Dual Pro. fR-Xe or PD!Zsiick MU -X); Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the Instructions noted above as a guideline. For mechanically fastened tile roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. 6.4.4 Two 2 Ny Underla went Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU -X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2 -ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP Is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2 -ply underlayment system Is desired. 6;S Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR: 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed In compliance with current Polyglass published Installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) In the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt applied "Cap Sheet" In the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Rall Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applled to the substrates noted in Section 5.6. Side laps shall be minimum 3 -inch and end -laps minimum 6 -inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8 -inch beyond the lap edge. 6.6 Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6,3). ✓ Polyflex G FR Is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5,6.3). NEMO ETC, U.C. Evaluatlon Report P12060.02.09 -R24 Certificate of Authorization #32455 6T" EDITION 12017) FOC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlayments;19S4) 233,1230 Revision 24; 01/24/2018 Page 13 of 14 ONEMO I etc. 6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section S.G. Side laps shall be minimum 3 -inch and end -laps minimum 6 -inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8 -inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail - boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after Installation of self -adhering membranes and before loading of roofing tiles Is forty-elght (48) hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for Information on product locations covered for F.A.C. 61G20-3 QA requirements, The following plants have qualified products under their respective physical properties specifications. Plant S eclfltation Productfsl Fernley, NV, Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick MU -X Hazleton, PA M -D 13.0004 Elastoflex G TU ASTM D1970 Polystick IR -Xe Hazleton, PA & Winter Haven, FL ASTM D1970 & FRSA/TRI April 2012 Polystick TU Plus ASTM D1970 & FRSA/TRI April 2012 Polystick TU Max Tuscaloosa, AL ASTM D4601, Tvpe II Polyglass G2 Base ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS, Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P Winter Haven, FL FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6, Elastoflex 56 G FR ASTM D6222 Polvflex G. Polyflex G FR 9. QUALITY ASSURANCE ENTITY: UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC. Evaluation Report P12060.02.09 -R24 Certificate o/Authorization #32455 6' EDITION (2017) FBC NON•HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24; 01/24/2018 Page 14 of 14