HomeMy WebLinkAboutLEVESQUE-ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 85/15/2020 10:44 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
SANDRA LEVESQUE
LEVESQUE RESIDENCE LOT #48
Street:
City, State, Zip: ST. LUCIE COUNTY , FL ,
4868 WATERSONG WAY
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
4231
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Dbl, U=0.79 603.00 ft²
SHGC=0.28
Dbl, U=1.06 254.00 ft²
SHGC=0.39
Dbl, U=1.06 80.00 ft²
SHGC=0.30
other (see details)42.00 ft²
other (see details)
8. Floor Types
a. Raised Floor
b. Slab-On-Grade Edge Insulation
c. other (see details)
R=19.0 800.50 ft²
R=0.0 744.00 ft²
R= 72.00 ft²
9. Wall Types
a. Concrete Block - Polystyrene Bead AggreR=11.0 4797.00 ft²
b. Frame - Wood, Adjacent R=11.0 90.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=22.0 2043.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 80 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:4.431 ft.
Area Weighted Average SHGC:0.305
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits Pstat
4
(979.0 sqft.)
(4887.0 sqft.)
(2043.0 sqft.)
(1616.5 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
b. Central Unit
a. Electric Strip Heat
b. Electric Strip Heat
k B t u / h r
34.2 SEER:16.00
45.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
34.0 COP:1.00
27.0 COP:1.00
b. Sup: Attic, Ret: Attic, AH: Attic
f t ² R
6 325
6 275
EF: 0.950
Glass/Floor Area: 0.231
Total Proposed Modified Loads:
Total Baseline Loads:
142.66
144.01 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
5-15-2020
6/18/2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
1
SANDRA LEVESQUE
LEVESQUE RESIDENCE LO
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
3
4231
4
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
ST. LUCIE COUNTY ,
St. Lucie
4868 WATERSONG W
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 UNIT 1 2343 25695
2 UNIT 2 1888 16992
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 FLEX ROOM 297 2673 No 0 Yes Yes1 Yes
2 LAUND. 65 585 No 0 Yes Yes1 Yes
3 CABANA 57 513 No 0 Yes Yes1 Yes
4 STAIR 99 891 No 0 Yes Yes1 Yes
5 FOYER 244 2196 No 0 Yes Yes1 Yes
6 ELE 25 225 No 0 Yes Yes1 No
7 GREAT ROOM 564 6768 No 0 Yes Yes1 Yes
8 STAIRWAY 243 2916 No 0 Yes Yes1 Yes
9 KITCHEN 300 3600 Yes 0 Yes Yes1 Yes
10 LAUNDRY 82 984 No 0 Yes Yes1 Yes
11 BEDROOM 4 190 2280 No 1 1 Yes Yes1 Yes
12 ELEVATOR 25 300 No 0 Yes Yes1 No
13 BATH 4 60 720 No 0 Yes Yes1 Yes
14 POWDER 72 864 No 0 Yes Yes1 Yes
15 A/C 2 20 180 No 0 Yes Yes1 No
16 MASTER BATH 200 1800 No 0 Yes Yes1 Yes
17 TOILET 24 216 No 0 Yes Yes1 Yes
18 M WIC 83 747 No 0 Yes Yes1 Yes
19 WIC 48 432 No 0 Yes Yes1 No
20 WIC 2 42 378 No 0 Yes Yes1 Yes
21 MASTER SUITE 515 4635 No 0 1 Yes Yes1 Yes
5/15/2020 10:44 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
22 BEDROOM 2 195 1755 No 0 1 Yes Yes1 Yes
23 HALLWAY 228 2052 No 0 Yes Yes1 Yes
24 STARIWAY. 104 936 No 0 Yes Yes1 Yes
25 BATH 2 50 450 No 0 Yes Yes1 Yes
26 WIC 3 50 450 No 0 Yes Yes1 Yes
27 BEDROOM 3 168 1512 No 0 1 Yes Yes1 Yes
28 BATH 3 50 450 No 0 Yes Yes1 Yes
29 OFFICE 131 1179 No 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 254 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -053 ft FLEX ROOM
2 65 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -018 ft LAUND.
3 57 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -010 ft CABANA
4 99 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -011 ft STAIR
5 244 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -029 ft FOYER
6 25 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -01 ft ELE
7 56 ft² 0 0 1______ 19Raised Floor 19 - - - - - - - -STAIRWAY
8 90 ft² 0 0 1______ 19Raised Floor 19 - - - - - - - -KITCHEN
9 35 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -KITCHEN
10 72 ft² 0 0 1______ 0Raised Floor 0 - - - - - - - -LAUNDRY
11 10 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -LAUNDRY
12 190 ft² 0 0 1______ 19Raised Floor 19 - - - - - - - -BEDROOM 4
13 25 ft² 0 0 1______ 19Raised Floor 19 - - - - - - - -ELEVATOR
14 60 ft² 0 0 1______ 19Raised Floor 19 - - - - - - - -BATH 4
15 8 ft² 0 0 1______ 19Raised Floor 19 - - - - - - - -POWDER
16 56 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -POWDER
17 5 ft² 0 0 1______ 19Raised Floor 19 - - - - - - - -A/C 2
18 28 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -MASTER BATH
19 4.5 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -MASTER SUITE
20 112 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -BEDROOM 3
21 40 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -BATH 3
5/15/2020 10:44 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
22 81 ft² 0 1 0______ 19Raised Floor 19 - - - - - - - -OFFICE
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2428 ft² Unfinishe 0.5 22 30.3______ No0 ft² 0.7 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2096 ft² N N0
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 0 101 ft² 0.1 Wood______ FLEX ROOM Blown
2 Under Attic (Unvented) 0 25 ft² 0.1 Wood______ LAUND. Blown
3 Under Attic (Unvented) 0 36 ft² 0.1 Wood______ GREAT ROOM Blown
4 Under Attic (Unvented) 0 200 ft² 0.1 Wood______ MASTER BATH Blown
5 Under Attic (Unvented) 0 24 ft² 0.1 Wood______ TOILET Blown
6 Under Attic (Unvented) 0 83 ft² 0.1 Wood______ M WIC Blown
7 Under Attic (Unvented) 0 48 ft² 0.1 Wood______ WIC Blown
8 Under Attic (Unvented) 0 42 ft² 0.1 Wood______ WIC 2 Blown
9 Under Attic (Unvented) 0 515 ft² 0.1 Wood______ MASTER SUITE Blown
10 Under Attic (Unvented) 0 195 ft² 0.1 Wood______ BEDROOM 2 Blown
11 Under Attic (Unvented) 0 228 ft² 0.1 Wood______ HALLWAY Blown
12 Under Attic (Unvented) 0 104 ft² 0.1 Wood______ STARIWAY. Blown
13 Under Attic (Unvented) 0 50 ft² 0.1 Wood______ BATH 2 Blown
14 Under Attic (Unvented) 0 50 ft² 0.1 Wood______ WIC 3 Blown
15 Under Attic (Unvented) 0 168 ft² 0.1 Wood______ BEDROOM 3 Blown
16 Under Attic (Unvented) 0 50 ft² 0.1 Wood______ BATH 3 Blown
17 Under Attic (Unvented) 0 124 ft² 0.1 Wood______ OFFICE Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 11 0FLEX ROOM 00018 9N Concrete Block - Polystyrene 0.30Exterior 162.0 ft² ____
2 11 0FLEX ROOM 00030 9E Concrete Block - Polystyrene 0.30Exterior 270.0 ft² ____
3 11 0FLEX ROOM 0005 9S Concrete Block - Polystyrene 0.30Exterior 45.0 ft² ____
4 11 0LAUND. 00010 9N Concrete Block - Polystyrene 0.30Exterior 90.0 ft² ____
5 11 0LAUND. 0001 9E Concrete Block - Polystyrene 0.30Exterior 9.0 ft² ____
6 11 0LAUND. 0007 9W Concrete Block - Polystyrene 0.30Exterior 63.0 ft² ____
7 11 0CABANA 00010 9W Concrete Block - Polystyrene 0.30Exterior 90.0 ft² ____
8 11 0STAIR 00011 9W Concrete Block - Polystyrene 0.30Exterior 99.0 ft² ____
5/15/2020 10:44 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
9 11 0FOYER 0008 9S Concrete Block - Polystyrene 0.30Exterior 72.0 ft² ____
10 11 0FOYER 00021 9W Concrete Block - Polystyrene 0.30Exterior 189.0 ft² ____
11 11 0GREAT ROO 00021 12N Concrete Block - Polystyrene 0.30Exterior 252.0 ft² ____
12 11 0GREAT ROO 00119 12NE Concrete Block - Polystyrene 0.30Exterior 119.0 ft² ____
13 11 0GREAT ROO 00014 12E Concrete Block - Polystyrene 0.30Exterior 168.0 ft² ____
14 11 0GREAT ROO 00021 12W Concrete Block - Polystyrene 0.30Exterior 252.0 ft² ____
15 11 0STAIRWAY 00024 12W Concrete Block - Polystyrene 0.30Exterior 288.0 ft² ____
16 11 0KITCHEN 00014 12E Concrete Block - Polystyrene 0.30Exterior 168.0 ft² ____
17 11 0LAUNDRY 0009 12E Concrete Block - Polystyrene 0.30Exterior 108.0 ft² ____
18 11 0BEDROOM 4 00013 12E Concrete Block - Polystyrene 0.30Exterior 156.0 ft² ____
19 11 0BEDROOM 4 00014 12S Concrete Block - Polystyrene 0.30Exterior 168.0 ft² ____
20 11 0BATH 4 0005 12S Concrete Block - Polystyrene 0.30Exterior 60.0 ft² ____
21 11 0BATH 4 0004 12W Concrete Block - Polystyrene 0.30Exterior 48.0 ft² ____
22 11 0POWDER 0009 12S Concrete Block - Polystyrene 0.30Exterior 108.0 ft² ____
23 11 0POWDER 0008 12W Concrete Block - Polystyrene 0.30Exterior 96.0 ft² ____
24 11 0MASTER BA 00014 9N Concrete Block - Polystyrene 0.30Exterior 126.0 ft² ____
25 11 0MASTER BA 0006 9E Concrete Block - Polystyrene 0.30Exterior 54.0 ft² ____
26 11 0MASTER BA 00016 9W Concrete Block - Polystyrene 0.30Exterior 144.0 ft² ____
27 11 0TOILET 0004 9W Concrete Block - Polystyrene 0.30Exterior 36.0 ft² ____
28 11 0M WIC 00012 9W Concrete Block - Polystyrene 0.30Exterior 108.0 ft² ____
29 11 0WIC 2 0006 9E Concrete Block - Polystyrene 0.30Exterior 54.0 ft² ____
30 11 0MASTER SUI 00014 9N Concrete Block - Polystyrene 0.30Exterior 126.0 ft² ____
31 11 0MASTER SUI 00020 9E Concrete Block - Polystyrene 0.30Exterior 180.0 ft² ____
32 11 0BEDROOM 2 00013 9E Concrete Block - Polystyrene 0.30Exterior 117.0 ft² ____
33 11 0HALLWAY 0007 10W Concrete Block - Polystyrene 0.30Exterior 70.0 ft² ____
34 11 0STARIWAY. 00013 9W Concrete Block - Polystyrene 0.30Exterior 117.0 ft² ____
35 11 0BATH 2 0005 9E Concrete Block - Polystyrene 0.30Exterior 45.0 ft² ____
36 11 0WIC 3 0005 9E Concrete Block - Polystyrene 0.30Exterior 45.0 ft² ____
37 11 0BEDROOM 3 00012 9E Concrete Block - Polystyrene 0.30Exterior 108.0 ft² ____
38 11 0BEDROOM 3 00014 9S Concrete Block - Polystyrene 0.30Exterior 126.0 ft² ____
39 11 0BATH 3 0005 9S Concrete Block - Polystyrene 0.30Exterior 45.0 ft² ____
40 11 0BATH 3 0003 9W Concrete Block - Polystyrene 0.30Exterior 27.0 ft² ____
41 11 0OFFICE 0009 9S Concrete Block - Polystyrene 0.30Exterior 81.0 ft² ____
42 11 0OFFICE 00012 9W Concrete Block - Polystyrene 0.30Exterior 108.0 ft² ____
43 11 0OFFICE 010 9N Frame - Wood 0.30.23Garage 90.0 ft² ____
5/15/2020 10:44 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 N Low-E Double 1.06 0.39 80.0 ft² 4 ft 0 in 0 ft 0 in Drapes/blindsVinyl Exterior 1______ Yes1 N
2 E Low-E Double 0.79 0.28 40.0 ft² 2 ft 0 in 0 ft 0 in NoneVinyl None______ Yes2 N
3 N Low-E Double 0.79 0.28 24.0 ft² 2 ft 0 in 0 ft 0 in NoneVinyl None______ Yes4 N
4 S Low-E Double 0.79 0.28 48.0 ft² 5 ft 0 in 3 ft 0 in NoneVinyl None______ Yes9 N
5 W Low-E Double 0.79 0.28 40.0 ft² 2 ft 0 in 25 ft 0 in NoneVinyl None______ Yes10 N
6 N Low-E Double 1.06 0.39 112.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______ Yes11 N
7 NE Low-E Double 1.06 0.39 62.0 ft² 10 ft 0 in 0 ft 0 in NoneVinyl None______ Yes12 N
8 E Low-E Double 0.79 0.28 56.0 ft² 2 ft 0 in 13 ft 0 in NoneVinyl None______ Yes13 N
9 W Low-E Double 0.79 0.28 42.0 ft² 2 ft 0 in 13 ft 0 in NoneVinyl None______ Yes14 N
10 W Low-E Double 0.79 0.28 24.0 ft² 2 ft 0 in 13 ft 0 in NoneVinyl None______ Yes15 N
11 E Low-E Double 0.79 0.28 18.0 ft² 2 ft 0 in 13 ft 0 in NoneVinyl None______ Yes16 N
12 E Low-E Double 0.79 0.28 14.0 ft² 2 ft 0 in 13 ft 0 in NoneVinyl None______ Yes17 N
13 E Low-E Double 0.79 0.28 28.0 ft² 2 ft 0 in 13 ft 0 in NoneVinyl None______ Yes18 N
14 S Low-E Double 0.79 0.28 40.0 ft² 5 ft 0 in 2 ft 0 in Drapes/blindsVinyl Exterior 1______ Yes19 N
15 S Low-E Double 0.79 0.28 5.0 ft² 5 ft 0 in 13 ft 0 in NoneVinyl None______ Yes19 N
16 S Low-E Double 0.79 0.28 8.0 ft² 2 ft 0 in 14 ft 0 in NoneVinyl None______ Yes19 N
17 S Low-E Double 0.79 0.28 8.0 ft² 2 ft 0 in 14 ft 0 in NoneVinyl None______ Yes20 N
18 W Low-E Double 0.79 0.28 8.0 ft² 2 ft 0 in 13 ft 0 in NoneVinyl None______ Yes23 N
19 N Low-E Double 0.22 0.17 18.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes24 N
20 N Low-E Double 0.22 0.17 24.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes24 N
21 W Low-E Double 0.79 0.28 10.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes27 N
22 N Low-E Double 1.06 0.3 80.0 ft² 8 ft 8 in 1 ft 5 in NoneVinyl None______ Yes30 N
23 E Low-E Double 0.79 0.28 20.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes31 N
24 E Low-E Double 0.79 0.28 20.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes32 N
25 W Low-E Double 0.79 0.28 20.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes33 N
26 E Low-E Double 0.79 0.28 10.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes35 N
27 E Low-E Double 0.79 0.28 20.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes37 N
28 S Low-E Double 0.79 0.28 40.0 ft² 5 ft 0 in 1 ft 5 in NoneVinyl None______ Yes38 N
29 S Low-E Double 0.79 0.28 10.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes38 N
30 S Low-E Double 0.79 0.28 10.0 ft² 2 ft 0 in 1 ft 5 in NoneVinyl None______ Yes39 N
31 S Low-E Double 0.79 0.28 40.0 ft² 5 ft 0 in 1 ft 5 in NoneVinyl None______ Yes41 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 400 ft² 400 ft² 10 ft 9 ft 19______
5/15/2020 10:44 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
3557.3 5195.29.000321Wholehouse .1891367.27Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 34 kBtu/hr ______ sys#1None 1
2 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#2None 2
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 16 34.2 kBtu/hr 1026 cfm 0.85______ sys#1Split 1 Single
2 Central Unit/ SEER: 16 45 kBtu/hr 1350 cfm 0.85______ sys#2Split 2 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 80 gal 60.9 gal 120 deg None______ None Garage
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 325 ft² Attic 75 ft² Default Leakage Attic (Default) c______ 1 1 (Default) c
2 Attic 6 275 ft² Attic 95 ft² Default Leakage Attic (Default) c______ 2 2 (Default) c
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
5/15/2020 10:44 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 FLEX ROOM
Default(8 lbs/sq.ft. f t ² f t 0.3 LAUND.
Default(8 lbs/sq.ft. f t ² f t 0.3 CABANA
Default(8 lbs/sq.ft. f t ² f t 0.3 STAIR
Default(8 lbs/sq.ft. f t ² f t 0.3 FOYER
Default(8 lbs/sq.ft. f t ² f t 0.3 ELE
Default(8 lbs/sq.ft. f t ² f t 0.3 GREAT ROOM
Default(8 lbs/sq.ft. f t ² f t 0.3 STAIRWAY
Default(8 lbs/sq.ft. f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft. f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 4
Default(8 lbs/sq.ft. f t ² f t 0.3 ELEVATOR
Default(8 lbs/sq.ft. f t ² f t 0.3 BATH 4
Default(8 lbs/sq.ft. f t ² f t 0.3 POWDER
Default(8 lbs/sq.ft. f t ² f t 0.3 A/C 2
Default(8 lbs/sq.ft. f t ² f t 0.3 MASTER BATH
Default(8 lbs/sq.ft. f t ² f t 0.3 TOILET
Default(8 lbs/sq.ft. f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 2
Default(8 lbs/sq.ft. f t ² f t 0.3 MASTER SUITE
Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft. f t ² f t 0.3 HALLWAY
Default(8 lbs/sq.ft. f t ² f t 0.3 STARIWAY.
Default(8 lbs/sq.ft. f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 3
Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft. f t ² f t 0.3 BATH 3
Default(8 lbs/sq.ft. f t ² f t 0.3 OFFICE
5/15/2020 10:44 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT