Loading...
HomeMy WebLinkAboutLEVESQUE-MANUAL J&DCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1 ...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Project Summary JUNE 14, 2018Date:UNIT 1 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information LEVESQUE RESIDENCEFor:LOT #48 4868 WATERSONG WAY, ST. LUCIE COUNTY, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh28454 Structure Btuh28106 Ducts Btuh4420 Ducts Btuh3478Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh32874 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh30005 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh4739 Ducts Btuh3761Central vent (0 cfm) Btuh0 CoolingHeating (none)24662466Area (ft²) Equipment latent load Btuh8500 2789427894Volume (ft³)Air changes/hour 0.150.28 Equipment Total Load (Sen+Lat)Btuh38504 Equiv. AVF (cfm) 70131 Req. total capacity at 0.70 SHR ton3.6 Heating Equipment Summary Cooling Equipment Summary Make Make CarrierTrade Trade CARRIER Model Cond 24APB648A00300AHRI ref Coil FB4CNP048L AHRI ref 201776123Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW11.9 Sensible cooling Btuh31500Heating output Btuh40772 Latent cooling Btuh13500 Temperature rise °F23 Total cooling Btuh45000Actual air flow cfm1600 Actual air flow cfm1600 Air flow factor cfm/Btuh0.049 Air flow factor cfm/Btuh0.051Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 2 ...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Project Summary JUNE 14, 2018Date:UNIT 2 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information LEVESQUE RESIDENCEFor:LOT #48 4868 WATERSONG WAY, ST. LUCIE COUNTY, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19420 Structure Btuh21686 Ducts Btuh4184 Ducts Btuh2912Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh23604 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh23368 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3017 Ducts Btuh2474Central vent (0 cfm) Btuh0 CoolingHeating (none)17651765Area (ft²) Equipment latent load Btuh5491 1765017650Volume (ft³)Air changes/hour 0.150.28 Equipment Total Load (Sen+Lat)Btuh28859 Equiv. AVF (cfm) 4481 Req. total capacity at 0.70 SHR ton2.8 Heating Equipment Summary Cooling Equipment Summary Make Make CarrierTrade Trade CARRIER Model Cond 24APB636A00300AHRI ref Coil FX4DNB037L AHRI ref 201779971Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.2 Sensible cooling Btuh23940Heating output Btuh24610 Latent cooling Btuh10260 Temperature rise °F20 Total cooling Btuh34200Actual air flow cfm1140 Actual air flow cfm1140 Air flow factor cfm/Btuh0.048 Air flow factor cfm/Btuh0.046Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name UNIT 1 FLEX ROOM 2 Exposed wall 272.8 ft 36.0 ft 3 Room height 11.3 dft 10.0 heat/coolft 4 Room dimensions ft18.0x18.0 5 Room area 2465.5 ft²324.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 532 348 624 310 180 132 237 117 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 48 0 1102 715 48 0 1102 715 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 24 0 403 600 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 112 0 3983 4819 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 119 57 102 51 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 62 54 2205 1840 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 816 680 1219 605 180 160 287 142 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 20 0 319 946 20 0 319 946 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 18 7 287 650 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 42 15 670 1585 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 56 20 894 2113 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 416 307 550 273 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 40 40 1870 639 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 48 48 1102 730 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 5 5 80 101 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 16 10 255 489 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 1190 1096 1964 975 0 0 0 0 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 20 0 504 982 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 8 0 128 375 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 24 0 383 1126 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 42 0 670 1970 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 490 490 1249 629 150 150 382 192 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 113 113 178 167 43 43 67 63 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 727 727 346 185 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 846 101 2797 0 324 36 997 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 99 19 529 0 0 0 0 0 6 c) AED excursion 0 -100 Envelope loss/gain 24413 22876 3391 2076 12 a) Infiltration 4041 1160 473 136 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 9 2070 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13)28454 28106 3865 2902 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 28454 28106 3865 2902 15 Duct loads 16%12%4420 3478 0%0%0 0 Total room load 32874 31584 3865 2902 Air required (cfm)Air required (cfm)1600 1600 188 147 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 2...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUND.CABANA 2 Exposed wall 17.0 ft 10.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft7.0x10.0 ft10.0x10.0 5 Room area 70.0 ft²100.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 100 76 136 68 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 24 0 403 600 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 70 70 125 62 100 100 179 89 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 10 10 16 15 0 0 0 0 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 70 17 471 0 100 10 277 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -70 -13 Envelope loss/gain 1151 675 456 76 12 a) Infiltration 224 64 132 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1375 739 588 114 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 201 39 14 Subtotal 1375 739 788 153 15 Duct loads 23%16%313 118 0%0%0 0 Total room load 1688 858 788 153 Air required (cfm)Air required (cfm)82 43 38 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 3...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name STAIR FOYER 2 Exposed wall 11.0 ft 27.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft11.0x9.0 ft228.0x1.0 5 Room area 99.0 ft²228.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 80 32 57 28 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 0 0 0 0 48 48 1102 730 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 110 110 197 98 190 170 305 151 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 0 0 0 0 20 0 504 982 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 0 0 0 0 240 240 612 308 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 0 0 0 0 0 0 0 0 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 99 11 305 0 228 27 748 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -14 806 Envelope loss/gain 502 84 3327 3006 12 a) Infiltration 145 42 355 102 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)646 126 3682 3108 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -646 -126 701 202 14 Subtotal 0 0 4383 3311 15 Duct loads 0%0%0 0 0%0%0 0 Total room load 0 0 4383 3311 Air required (cfm)Air required (cfm)0 0 213 168 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 4...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name ELE GREAT ROOM 2 Exposed wall 0 ft 67.8 ft 3 Room height 10.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft5.0x5.0 ft591.5x1.0 5 Room area 25.0 ft²591.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 252 140 251 125 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 112 0 3983 4819 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 0 0 0 0 119 57 102 51 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 0 0 0 0 62 54 2205 1840 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 180 124 222 110 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 56 20 894 2113 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 0 0 0 0 264 222 398 197 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 42 0 670 1970 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 100 100 255 128 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 0 0 0 0 60 60 95 89 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 0 0 0 0 75 75 36 19 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 25 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -13 -1248 Envelope loss/gain 255 116 8855 10085 12 a) Infiltration 0 0 1072 308 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 4 920 Appliances/other 0 0 Subtotal (lines 6 to 13)255 116 9927 11313 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -255 -116 0 0 14 Subtotal 0 0 9927 11313 15 Duct loads 0%0%0 0 23%16%2260 1810 Total room load 0 0 12186 13122 Air required (cfm)Air required (cfm)0 0 593 665 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 5...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name STAIRWAY KITCHEN 2 Exposed wall 25.0 ft 15.0 ft 3 Room height 12.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft251.0x1.0 ft15.0x20.0 5 Room area 251.0 ft²300.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 180 162 290 144 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 0 0 0 0 18 7 287 650 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 300 276 495 246 0 0 0 0 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 24 0 383 1126 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 0 0 0 0 0 0 0 0 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 56 56 27 14 225 225 107 57 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 5 0 14 0 0 0 0 0 6 c) AED excursion 304 43 Envelope loss/gain 918 1690 685 895 12 a) Infiltration 395 113 237 68 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13)1313 1803 921 2963 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 9 4 0 0 14 Subtotal 1321 1808 921 2963 15 Duct loads 23%16%301 289 23%16%210 474 Total room load 1622 2097 1131 3437 Air required (cfm)Air required (cfm)79 106 55 174 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 6...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY BEDROOM 4 2 Exposed wall 9.0 ft 28.0 ft 3 Room height 12.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft82.0x1.0 ft204.0x1.0 5 Room area 82.0 ft²204.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 108 94 168 84 168 140 251 125 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 14 5 223 528 28 10 447 1056 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 168 115 206 102 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 0 0 0 0 40 40 1870 639 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 0 0 0 0 5 5 80 101 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 0 0 0 0 8 5 128 244 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 0 0 0 0 0 0 0 0 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 82 82 39 21 190 190 90 48 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 14 2 53 0 6 c) AED excursion 205 -135 Envelope loss/gain 431 838 3125 2182 12 a) Infiltration 142 41 442 127 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)573 879 3567 2769 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 1 0 14 Subtotal 573 879 3568 2769 15 Duct loads 23%16%130 141 23%16%812 443 Total room load 703 1020 4380 3212 Air required (cfm)Air required (cfm)34 52 213 163 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 7...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name ELEVATOR BATH 4 2 Exposed wall 0 ft 9.0 ft 3 Room height 12.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft5.0x5.0 ft13.0x5.0 5 Room area 25.0 ft²65.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 60 52 93 46 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 0 0 0 0 8 5 128 244 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 0 0 0 0 48 48 86 43 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 0 0 0 0 0 0 0 0 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 25 25 12 6 60 60 29 15 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 5 1 19 0 6 c) AED excursion -1 140 Envelope loss/gain 12 6 355 489 12 a) Infiltration 0 0 142 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)12 6 497 530 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -12 -6 4 2 14 Subtotal 0 0 501 531 15 Duct loads 23%16%0 0 23%16%114 85 Total room load 0 0 615 616 Air required (cfm)Air required (cfm)0 0 30 31 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 8...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 1 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name POWDER A/C 2 2 Exposed wall 18.0 ft 0 ft 3 Room height 12.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft9.0x9.0 ft5.0x4.0 5 Room area 81.0 ft²20.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 22.9622.96 14.9014.90 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 16.8016.80 25.0025.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 47.3047.30 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 36.1436.14 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 15.9615.96 37.7337.73 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 108 108 194 96 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 15.9815.98 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 22.9622.96 15.2115.21 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 20.2920.29 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 15.9615.96 30.5530.55 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 108 100 179 89 0 0 0 0 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 25.2025.20 49.1249.12 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 8 0 128 375 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 15.9615.96 46.9146.91 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.281.28 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 0 0 0 0 0 0 0 0 FF 19C-19cscp19C-19cscp 0.0490.049 --0.480.48 0.250.25 9 9 4 2 5 5 2 1 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 72 16 443 0 3 0 0 0 6 c) AED excursion 93 0 Envelope loss/gain 948 656 2 1 12 a) Infiltration 284 82 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1232 738 2 1 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 1 0 -2 -1 14 Subtotal 1233 738 0 0 15 Duct loads 23%16%281 118 23%16%0 0 Total room load 1513 856 0 0 Air required (cfm)Air required (cfm)74 43 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 9...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 2 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name UNIT 2 MASTER BATH 2 Exposed wall 189.9 ft 36.0 ft 3 Room height 10.0 dft 10.0 heat/coolft 4 Room dimensions ft200.0x1.0 5 Room area 1765.0 ft²200.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 280 149 266 132 140 89 159 79 .GG 10A-v10A-v 0.8200.820 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 24 0 605 1376 24 0 605 1376 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 28 0 693 1577 28 0 693 1577 GG 1A-r1obd1A-r1obd 1.0801.080 nene 30.2430.24 40.1840.18 80 0 2419 3214 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 670 592 1060 526 60 60 108 53 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 10 5 244 434 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 48 24 1177 2097 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 20 10 487 868 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 280 180 323 160 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 42.2042.20 80 4 3741 3376 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 24.3624.36 43.3843.38 20 10 487 868 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 670 640 1147 569 160 160 287 142 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 10 0 244 589 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 20 0 487 1179 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 1765 1765 2798 2623 200 200 317 297 FF 19C-19cscp19C-19cscp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 206 27 742 0 0 0 0 0 6 c) AED excursion 0 -373 Envelope loss/gain 16921 19589 2168 3152 12 a) Infiltration 2499 717 473 136 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 6 1380 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)19420 21686 2641 3288 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 19420 21686 2641 3288 15 Duct loads 22%13%4184 2912 22%13%569 441 Total room load 23604 24597 3210 3729 Air required (cfm)Air required (cfm)1140 1140 155 173 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 10...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 2 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name TOILET M WIC 2 Exposed wall 4.0 ft 12.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft4.0x6.0 ft83.0x1.0 5 Room area 24.0 ft²83.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 30.2430.24 40.1840.18 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 42.2042.20 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 40 30 54 27 120 120 215 107 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 10 0 244 589 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 24 24 38 36 83 83 132 123 FF 19C-19cscp19C-19cscp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 156 -28 Envelope loss/gain 335 808 347 202 12 a) Infiltration 53 15 158 45 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)388 823 504 247 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 157 79 14 Subtotal 388 823 661 326 15 Duct loads 22%13%84 111 22%13%143 44 Total room load 472 934 804 370 Air required (cfm)Air required (cfm)23 43 39 17 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 11...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 2 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC WIC 2 2 Exposed wall 0 ft 6.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x8.0 ft6.0x7.0 5 Room area 48.0 ft²42.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 30.2430.24 40.1840.18 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 60 60 108 53 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 42.2042.20 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 48 48 76 71 42 42 67 62 FF 19C-19cscp19C-19cscp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -7 -14 Envelope loss/gain 76 64 174 102 12 a) Infiltration 0 0 79 23 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)76 64 253 124 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 76 64 253 124 15 Duct loads 22%13%16 9 22%13%55 17 Total room load 93 73 308 141 Air required (cfm)Air required (cfm)4 3 15 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 12...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 2 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MASTER SUITE BEDROOM 2 2 Exposed wall 33.9 ft 13.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft415.0x1.0 ft13.0x15.0 5 Room area 415.0 ft²195.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 140 60 108 53 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 30.2430.24 40.1840.18 80 0 2419 3214 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 200 176 315 156 130 110 197 98 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 24 12 589 1048 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 20 10 487 868 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 42.2042.20 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 415 415 658 617 195 195 309 290 FF 19C-19cscp19C-19cscp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1 0 1 0 0 0 0 0 6 c) AED excursion -578 211 Envelope loss/gain 4090 4511 993 1467 12 a) Infiltration 447 128 171 49 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)4537 5099 1164 1976 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4537 5099 1164 1976 15 Duct loads 22%13%978 685 22%13%251 265 Total room load 5514 5784 1415 2241 Air required (cfm)Air required (cfm)266 268 68 104 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 13...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 2 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name HALLWAY STARIWAY. 2 Exposed wall 28.0 ft 13.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft336.0x1.0 ft13.0x8.0 5 Room area 336.0 ft²104.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 30.2430.24 40.1840.18 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 90 50 90 44 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 42.2042.20 40 2 1870 1688 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 190 170 305 151 130 130 233 116 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 20 0 487 1179 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 336 336 533 499 104 104 165 155 FF 19C-19cscp19C-19cscp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 72 6 166 0 0 0 0 0 6 c) AED excursion 515 -33 Envelope loss/gain 3451 4077 398 238 12 a) Infiltration 368 106 171 49 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3819 4183 569 287 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 412 208 -569 -287 14 Subtotal 4231 4390 0 0 15 Duct loads 22%13%912 589 22%13%0 0 Total room load 5143 4980 0 0 Air required (cfm)Air required (cfm)248 231 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 14...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 2 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 2 WIC 3 2 Exposed wall 5.0 ft 5.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft5.0x10.0 ft5.0x10.0 5 Room area 50.0 ft²50.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 30.2430.24 40.1840.18 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 50 40 72 36 50 50 90 44 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 10 5 244 434 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 42.2042.20 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 0 0 0 0 0 0 0 0 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 50 50 79 74 50 50 79 74 FF 19C-19cscp19C-19cscp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 138 -14 Envelope loss/gain 395 682 169 105 12 a) Infiltration 66 19 66 19 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)460 701 235 124 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 460 701 235 124 15 Duct loads 22%13%99 94 22%13%51 17 Total room load 560 795 285 140 Air required (cfm)Air required (cfm)27 37 14 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-15 10:41:49Right-Suite® Universal 2019 19.0.07 RSU08101 Page 15...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet JUNE 14, 2018Date:UNIT 2 By:QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 BATH 3 2 Exposed wall 26.0 ft 8.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft12.0x14.0 ft10.0x5.0 5 Room area 168.0 ft²50.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13B-5ocws13B-5ocws 0.0640.064 nene 1.791.79 0.890.89 0 0 0 0 0 0 0 0 .GG 10A-v10A-v 0.8200.820 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 11 GG 1A-c1ov1A-c1ov 0.9000.900 nene 25.2025.20 57.3457.34 0 0 0 0 0 0 0 0 GG 1A-r1obd1A-r1obd 1.0801.080 nene 30.2430.24 40.1840.18 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 nene 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 sese 1.791.79 0.890.89 120 96 172 85 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 24 12 589 1048 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 sese 24.3624.36 43.3843.38 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 sese 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 swsw 1.791.79 0.890.89 140 90 161 80 50 40 72 36 GG 10A-m10A-m 1.6701.670 swsw 46.7646.76 42.2042.20 40 2 1870 1688 0 0 0 0 GG 10A-m10A-m 1.6701.670 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 10A-v10A-v 0.8200.820 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 swsw 24.3624.36 43.3843.38 10 5 244 434 10 5 244 434 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 13B-5ocws13B-5ocws 0.0640.064 nwnw 1.791.79 0.890.89 0 0 0 0 30 30 54 27 GG 1A-h1ov1A-h1ov 0.9000.900 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2om1D-c2om 0.8700.870 nwnw 24.3624.36 58.9558.95 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 1D-c2ov1D-c2ov 0.5700.570 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.491.49 168 168 266 250 50 50 79 74 FF 19C-19cscp19C-19cscp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 98 15 420 0 35 6 155 0 6 c) AED excursion -167 194 Envelope loss/gain 3722 3418 603 764 12 a) Infiltration 342 98 105 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4064 3976 709 794 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4064 3976 709 794 15 Duct loads 22%13%876 534 22%13%153 107 Total room load 4940 4510 861 901 Air required (cfm)Air required (cfm)239 209 42 42 2020-May-15 10:41:52 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1 ...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Duct System Summary JUNE 14, 2018Date:UNIT 1 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information LEVESQUE RESIDENCEFor: LOT #48 4868 WATERSONG WAY, ST. LUCIE COUNTY, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.163in/100ft0.163 Actual air flow cfm1600cfm1600 Total effective length (TEL) ft306 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st8145.011.0VlFx0x04.00.3213130616cBATH 4 st8165.019.0VlFx0x08.00.2721632134380hBEDROOM 4 st11195.064.0VlFx0x05.00.193838788hCABANA st11215.063.0VlFx0x08.00.1801471883865hFLEX ROOM st9155.026.0VlFx0x06.00.276841072191hFOYER st9135.017.0VlFx0x06.00.329841072191hFOYER-A st7195.049.3VlFx0x07.00.2051661483281cGREAT ROOM st7195.046.8VlFx0x07.00.2071661483281cGREAT ROOM-A st7175.039.0VlFx0x07.00.2341661483281cGREAT ROOM-B st7175.038.0VlFx0x07.00.2351661483281cGREAT ROOM-C st7155.029.0VlFx0x06.00.27287281719cKITCHEN st7155.022.0VlFx0x06.00.28287281719cKITCHEN-A st11235.071.0VlFx0x04.00.16343821688hLAUND. st8175.024.0VlFx0x05.00.25152341020cLAUNDRY st2115.05.6VlFx0x05.00.41543741513hPOWDER st1115.07.0VlFx0x07.00.410106792097cSTAIRWAY 2020-May-15 10:41:52 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 2 ...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st9 Peak AVF 522 366 0.163 665 12.0 0x0 VinlFlx st3 st10 Peak AVF 309 198 0.163 566 10.0 0x0 VinlFlx st9 st11 Peak AVF 309 198 0.163 566 10.0 0x0 VinlFlx st10 st3 Peak AVF 522 366 0.163 665 12.0 0x0 VinlFlx st2 Peak AVF 351 289 0.251 794 9.0 0x0 VinlFlx st8 Peak AVF 277 246 0.251 628 9.0 0x0 VinlFlx st2 st1 Peak AVF 727 945 0.205 884 14.0 0x0 VinlFlx st7 Peak AVF 648 839 0.205 785 14.0 0x0 VinlFlx st6 st6 Peak AVF 648 839 0.205 785 14.0 0x0 VinlFlx st1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb3 0x 16000 1600 0 0 0 0 x0 0 VlFx 2020-May-15 10:41:52 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 3 ...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Job:Duct System Summary JUNE 14, 2018Date:UNIT 2 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information LEVESQUE RESIDENCEFor: LOT #48 4868 WATERSONG WAY, ST. LUCIE COUNTY, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.161in/100ft0.161 Actual air flow cfm1140cfm1140 Total effective length (TEL) ft310 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st4120.015.1VlFx0x04.00.3703727795cBATH 2 st5135.010.0VlFx0x04.00.3454242901cBATH 3 st4140.016.0VlFx0x07.00.321104682241cBEDROOM 2 st5155.013.0VlFx0x08.00.2982092394940hBEDROOM 3 00ShMt0x0001151242490hHALLWAY st4180.016.0ShMt0x06.00.2551151242571hHALLWAY-A st4200.040.0VlFx0x04.00.2081739804hM WIC st4260.050.0VlFx0x06.00.1611731553729cMASTER BATH st4260.044.6VlFx0x07.00.1641341332892cMASTER SUITE st4220.032.0VlFx0x07.00.1981341332892cMASTER SUITE-A st4240.046.0VlFx0x04.00.1754323934cTOILET st4180.023.0VlFx0x04.00.2463493hWIC st4160.027.8VlFx0x04.00.266715308hWIC 2 st5135.013.6VlFx0x04.00.336614285hWIC 3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 722 767 0.161 718 14.0 0x0 VinlFlx st5 Peak AVF 294 257 0.298 665 9.0 0x0 VinlFlx 2020-May-15 10:41:52 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 4 ...ocuments\Wrightsoft HVAC\LEVESQUE RESIDENCE.rup Calc = MJ8 Front Door faces: SW Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb2 0x 11400 1140 0 0 0 0 x0 0 VlFx