HomeMy WebLinkAbout1545 Putilzer Rd - blower door testIl�� f� rim}w,l
Planning & Development Services
Building % Code Regulation Division
2300 Virginia Ave, lira 201
Fort Pierce, FL 349'2
Phone: 372-462-2165 i-ax:732-462-6443
BLOWER DOOR v ES T FORM
House Infi0e�ra-don Test, Cer`vhler-l`don
Prescriptive and Perfoirro-a ce 6 pAhod
Date: SI(� � ti o i o �erm� �: � � v 9- 0 3 ')
Contractor: C, I C o "'s f r 44 C `-i o
Job AQWdress: 1 S !� S C - I � t ze� � 1) 1 F¢ f � e r E L
New Construction — Complete Eyds'C' g — After Addh"lon
House Infiltration : est- P,esults SLC ivlim@"L-e Zone 2
CFM (50) _ — 3 J Test Date:Volume
(Q1 12J i
ACE : (50) =CFM (50) 3160 J Volume = _ 3 - t" Mechanical Ventilation regUiFed less than 3 A'
Massing results must be & ACH (50) or less (k/) Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate o. not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(14), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
I --K ResiciGn-Cial
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
i esting Com nanv
Company Name: Pro -Duct Services
Address: '19'15 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate %one 2.
Signature:
Printed Name: Mai tin Nein
License/Certification #: 5061633
BUILDING PERFORMANCE
INSTI TUTE, INC.
107 Hermes Road, Suite 210
Malta, IVY 12020
(877) 274-1274
Of
www.bpi.org
W OL
'
Martin Klein
SPI 00- 5061w3
sn (SEE REVERSE SIDE EOR DESIGNATIONS AND EKRIRATION OATES)
CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE
lnf-lkmtion & Duct Leakage gDj-) 4r'26l2D2I
BUILDING PERFORMANCE INSTITUTE, INC.