HomeMy WebLinkAbout1545 Putilzer Rd - blower door testIl�� f� rim}w,l Planning & Development Services Building % Code Regulation Division 2300 Virginia Ave, lira 201 Fort Pierce, FL 349'2 Phone: 372-462-2165 i-ax:732-462-6443 BLOWER DOOR v ES T FORM House Infi0e�ra-don Test, Cer`vhler-l`don Prescriptive and Perfoirro-a ce 6 pAhod Date: SI(� � ti o i o �erm� �: � � v 9- 0 3 ') Contractor: C, I C o "'s f r 44 C `-i o Job AQWdress: 1 S !� S C - I � t ze� � 1) 1 F¢ f � e r E L New Construction — Complete Eyds'C' g — After Addh"lon House Infiltration : est- P,esults SLC ivlim@"L-e Zone 2 CFM (50) _ — 3 J Test Date:Volume (Q1 12J i ACE : (50) =CFM (50) 3160 J Volume = _ 3 - t" Mechanical Ventilation regUiFed less than 3 A' Massing results must be & ACH (50) or less (k/) Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate o. not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(14), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. I --K ResiciGn-Cial Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. i esting Com nanv Company Name: Pro -Duct Services Address: '19'15 Rio Vista Drive, Ft. Pierce, FL 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate %one 2. Signature: Printed Name: Mai tin Nein License/Certification #: 5061633 BUILDING PERFORMANCE INSTI TUTE, INC. 107 Hermes Road, Suite 210 Malta, IVY 12020 (877) 274-1274 Of www.bpi.org W OL ' Martin Klein SPI 00- 5061w3 sn (SEE REVERSE SIDE EOR DESIGNATIONS AND EKRIRATION OATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE lnf-lkmtion & Duct Leakage gDj-) 4r'26l2D2I BUILDING PERFORMANCE INSTITUTE, INC.