HomeMy WebLinkAboutConstruction plans- SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED, THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2- AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2- THREADED ROD (FOR A 'HIGH SET-) IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2- HOLE IS DRILLED INTO THE CONCRETE 1-1/2. OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION. ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"0" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPUFT (PLF) ANCHOR SPACING 20'-0" 400 S-T 13'-B" 280 S-6- 11'-8" 240 3'-fi' 10'-0" 200 31-T 8'-0.. 160 S-r 120 TABLE 2 SKID RuNINER SPACING - SHED WIDTH X1 X2 X3 1'-164' 1'-1q" 2--8- 6'-4- - 10'-0" V-7- 6-10' - 8'-O" 0'-9" 6'-6- 6.-0. 0'-10" 51" - -VALUES ME FROM END OF JOIST TO CENTERS OF (2) 4-.4- SODS ONLY. 13'-e' WIDE SHEDS HAVE (4) SETS OF SKIDS. SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)4-1144- BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. i 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS I TABLE PAD 3A TYPES TYPE PAD DIMENSIONS MAX. LOAD• MATERIAL 1 2"x8"x16" 1778LBS CONCRETE CEMENT BLOCK AND SAND QUALITY MIX II 4'x8"x16" 3500LBS CO CEMENT CREFE BLOCK QU AND SAND MIX III 16-06- 3950LBS ABS PLASTIC PADS IV 8"x8"x16" 1900LBS CONCRETE CEMENT BLOCK AND SAND QUALITY MIX • BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOLD CONCRETE BLOCKS (SW.15') MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48' WITHOUT REINFORCING. 2. ASS PADS REQUIRED ON IV-B- AND 13'-B' WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER AD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-B" SW/DW 4.15/332 O" T7 a" 6'-0' 1936LB I, II, III, OR N 1879LB I. II, III, OR N 11'-8" SW/DW 6.00/480 0' 10 6' 6'-0' 255819 I, II, III, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 O" TO 6' 6'-0' 2400LB I, II, III, OR IV 2400LB I, II, III, OR N 8'-0. SW 4.00/320 0- TO 6' 6'-0' 2029LB I, II, III, OR IV 2133LB I, II, III, OR N 6'-0- SW 3.00/240 O' TO 6' 6'-0' 1658LB I, II. III, OR IV 1866LB I, II, III. OR N • LOTH WIDTH OF UPUFr ON RUNNER aPAD S 1PACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CETTTR. 3. USE SAIJE MAXIMUM SPACING FOR INTERIOR SPACING. RECEIVED 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW UPLIFT (PLF) END ANCHOR-- MAX. INTERIOR SPACING--; 13'-8" 7.00 243 Y-e TO S-Or 10'-0" 11'-B" 6.00 208 0'_cr TO 3'-0- 10'-0' _ 50011" __ 174 1V-V TO 3,-(r ,10'-0 8'-O' 4.00 138 (1-T TD S-o* 10'-0" 6'-0. 3.00 104 0-0- TO S-o' 10'-O' TABLE B 30' AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW UPLIFT (PLF) END ANCHOR -- MAX. INTERIOR SPACING••• 20'-0" 1 10.00 1 400 1 0'-0' TO 3'-T 1 5'-0' • LOAD WIDTH OF UPUFF ON RUNNER 0 S TION ROM END WALL OF AUGER MAY 1010 »•`MMAIOIMUM SPACING BETWEEN ANTI RSANCHOR Permitting Department 1NOTANECHOR SPACING IS DESIGNED AS PER ASCE-7. St. Lucie County 2. ALL MEASUREMENTS ME CENTER-TO-CENVUL 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ME REOUIRED IF SPACING IS MORE THAT 10'-0' BETWEEN ANCHORS_ 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. _ va .. _ 2.4. GALVANIZED WASHER " 2'4' GALVANRED WASHER WITH 1/Y NUT 1/2' THREADED ROD 1 /2�'{iHRFlDEU R0 EYES BOLTED TOCErHER WITH 1/2"4' OPTIONAL FOR T9GH 1/2' COUPLER NOTCH OR COUNTERSINK BOLT THRU 2'x4' BOTTOM PLATE OPTIONAL FOR_SEf _ BOLT h NUT WITH (2)2"x2" GALVANIZED CAPACITY) 21C BOTTOM PLATE NAILED N/2- COUPZER ]�", -�1%2 xi2 FORGED_LYEBO�-'b'ea+."� WASHERS (2XIDOW SHEAR - �4" MIN. 1/2'x5' (400 IBJ CONCRETE GE WEDGE ANCHOR INTO SLAB TO 2"xB' P.T. BASE --------MIN. a :. • • • THRU 2'P.T. BOTTOM PATE ELT BOLTED TOOT T1tIE1/2 z2 '' � Ash" TPE^ OR N PAD WRH G (SEE TABLE 1 FOR SPACING) Ia_______ )2*x2 x xllk'➢I BOLT & NUT"Wm1 (2)2 x2c(+1LVANIZED WASHERS (2000LS!SHEM CAPACRYj TILOCKI G AS REOUI ED�($EFa TMLE 3). 1/2 3- (400 LB.) CONCRETE WEDGE ANCHOR SIMPSON A-24 CONRETE SLAB BY OTHERS THROUGH CUP OR EQUAL LOCAL CODES END JURISDICTION CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES AND JURISDICTION 30 EARTH AUGF,ftC,ANCNOR �� - (SEE TABLE 7 FOR SPACING) ,f: (sEE TM 4`Fo �sP mc)„�,•- „�....�. S �'- -•- I J_ ITH:5KID SHED WITH SKID SHED WITH FLOOR' OPTION TO PADfORN'BLOCKI� ANCHORED TO CONCRETE ANCHOREDD TO CONCRETE TIE -DOWN DETAILS l) CODE VERSION T� Sat] ea, f2alm, Aaf£-] MANUFACTURER SUPDUA lens BUILDING TYPE fis u 51oNGE CONSTIMMON TYPE V-B FIRE PROTECTION ERNE ME SUPPRESSON SYSTEM NaNE OCCUPANCY SICRAIf ALLOWABLE NUMBER OF STORES 1 BASIC WINO SPEED V.-fmnpn EXPOSURE C ENCLOSURE H U:SS) INTERNN. PRESSURE COEFFOENT ./- ata IMPORTANCE FACTOR 1.15 ROOF DEAD LOTH IOPSF ROOF LIVE LOAD 2DPiF pR lOOIOv FLOOR DEAD LOAD ePss BOOR LIVE LOAD S16 TLPY - UMFSF OPT. •R• RATING OF WALLS, FLOOR, ROOF WA MODOLES PBT BUILDING 1 HURRICANE PROTECTION USAGE Ip HURPoGNE SHELTER USAGE M SQUARE FOOTAGE Ds TIM ]2D SQAT. .REVISIONS REV I DESCRIPTION DATE BY 1 12017 M 11/12/17 Ore 2 a1pAiD YCNW 6• AFL 411E INOIOR TxNi51M1 5/25/10 YR (n (TB p Dda: LLJ 4/26/16 Xol¢ (n N/A ul. LLJ ALL p GENERAL NOTES 1. FOUNDATION PLANS ME NOT PART OF THIS PUN SET AND ME GOVERNED BY LOCAL JURISDICTION. LJ.J 2. THIS BUILDING IS EXEMPT FROM THE FBC J ENERGY CONSERVATION CODE PER SECTION 1016.22. M 3. REFER TO TIE -DOWN DETAILS FOR PROPER D INSTALLATION REQUIREMENTS TO MEET CODE. O -d REVIEWED FOR O®E CORAPL1ANCE T. LUCIE COUNTY I BOCC LLJ p 0 1/9/19 g J �MgHhe- Ose,#6 P:E � U Flodaa,.LceD, s46o11 zShoot: AD-1 OF 1 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN #SS-B-180-C Side Wall Header Schedule (180C) End Wall Header Schedule (180c) Foswo,se w/o step _ k Building Width Slze(dj Max. Span NJlbj each e c) t D4 ALUMINUM ROOF SHEATHING 8¢e Up to 14'Wide Fasteners w/st2p lixc 60' 0 4-3'X0.131'nails �- (each end) --- — — •-0° MAX. wim. Bpan NJ{D) 2-2k (c) B.m Did) 6-3•x0.131-rlxila 1-0"X4" 6-0" 0 3 - 3' x 0 131' na Is a. TaDWatetl values are for No. 2 grade Spence-Pme lr lumber. I 1 r- m n 0 I.A RUNNERS I m END INA TRUSS 2'x4' TRUSS MAIL O.C. b. NJ- Number arjack studs required to support each end. 4k4'v/a46-0" 1 6-3'z 0.131'nails a. Tabulated Number ofj are for s r 2 fired t SpmceFia each end. c. No Jack b. NJ - Number ofjack studs required to support each end. tl. No Jack studs. but 26 studs laid AaL-------- ) .--�.,,_ C. Window header for vrintlw+openings that hale more than SO%combined stud wall abole -„ and below, othenAse use door header schedule. Ydata d. See headerdetails for attemate layouts, i.e. 2-2'k4t. SEE FAtiTETIm srRavAs rm HvvAARs° or4'x4' P.T. a sz 1EU'm saanuE NRnxaNt R e. The header can be attached to the top plate and thus hale the combined strength sAND "It. Nu.`E ER To -WHE .4" MO't CODE WFOR TION equivalent and use the maximum span stated. CODE vElmoN mr 111pi F �7• Ww1. stuns � I course E1' I n E ce 31A•'MIIN 1/i 0.1Wf%O mom nun m (1µr• 1 m 1swi es �l ssat WW. SnaS qn 6 SFL19aD 12' NAx. HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & OP 0 AL & DOORS DOOR 6' WIDE OR LESS Zd A x4" W/P W MANUFALRURER SUPOWe scans BNIBING TYPE spy s7mvf CONSTRUCTION TYPE v"B ME PROTECTION IME PRE svPPR®SUN SYSTEM KW Occui siw¢ AUZWABLE NUMBER OF STi 1 SAM WING SPEED vr1BOlOA "Y"asuRE c ENCLOSURE B1tlD5m a91FRNAL PRESSURE 000maw a/- els IMPORTANCE FACTOR 1.15 ROOF DM LBAB 1005E G.P.I. — + NOTES -OPTION 0 ECTRI . ROOF LIVE LOAD amsFm 3005 wM INn OUTLET ♦ O,�. K -ALL WIRING SHALL BE 14 GAGE S-WIRE MC GBIP �L`�?w�u ''�.�ii.'t1 FLOOR OFOD L04D ImsP N 1 r -ENCASE IN ALL METAL BO%ES Willian E. Nes , III I FLOOR LIVE LOAD STD. Ta>sc - 17bP5F OPT. DESIGN PREssuREs SOURCE Ir SMP-51, SMI-79, ICL 5195040 '"• Roof ROOF FRAMING PLAN L WIRING DIAGRAM 106190aW,,PPinte Terrace I R^" °F W°'1s' FIDTIR, ROOF N/A MOGu(Es Pm Bu9rnNc t +z7.a -s4.7 ALLS DOORS/WINDOWS -29.2 (OPTIONAL) Oou,a, RWddaa4734 xuRwcAt¢ PRmEcnoN usACB No +32.5 _ HURRICANE SHELTER USAaE No IInIF m Auae Ea• ov mam A WdvaW IaGTxNs vWf SOU,NE ROOTAGE 1719 San. m us mEvvAi REVISIONS _p± p rkA CO1A" ce.4"NE REV I DESCRIPTON I DATE I BY / / wAaWW wAu / � / /� affATlONc ovrvNs Y WAX DBTAa on, IN ruN1oR Z GmMn Br MTB a"avwWs ;/ i Z 12/12/17 wNE N A snvs v SQU RATE U) Pa91 RAW FRAMNW SS-B-180C wE RwE wE IaAre a Li I. P1,wr A NEWT PnAArr�T OF T� P1.w OE, AND u>E TIWm "vibis "+ 21Na 6WaN0 RMT}FIVr TIm . RC E rc, WNgA9ATRIN sTEm SEc>nffn m m1E P1AlE ANW Raw rPgeFc Wn11 ann• W J ucE PDI lW1a]E. 3. rurTR % TE IxrAvs FOR PP69i NSl/99Allm dA u I L., y WA^-14^T STANDARD WALL DETAIL N"m RAu Tr.UeNW 1aLm1a 7+x mrmwus Tlvu Q �nuvmAt(Ts m Coen. AREc 6s' m tYa' APaa e-r To 1ZX WITH 31V� DOOR &WINDOW OPnONs rWUNaONtlI su ro Roa Am tNsuRE A caNONuas Ina PATH wears�Ny A� NOr txMOxxNs slWn IhTIi aMNS TES, m ams U) O s. NL sws Rums, TR59i ac. AeE a4 iz W. DKE'r a Nmm a sTAWivas ova+ Am su. a T,a1 RAKE m m' MOtAIW ELEVATION CROSS-SECTION END ELEVATION - J/A P.T. 0.YAG'O 9W1 ff imNO OF GV.VAV® ST[FL OF Nar LESS V DOOR. 14a4 aam r� E _ 3/r TAW TWN Oda' NOMWL n4aaEu W a curries To BE Wrnwm WN-s l: BY Wnms TNW1 uxx �6 TYPICAL ARCH FRAME WITH ODOR TA rm .M .. ANW - a/A' P.T. Taa W O 7. uL Wgrows Arm W0(AS To 1kEr n We" SwDnoawNs s O (a TM 40 iW M amen c AO FA+s a Woods BDR b oEflAII FIXORIF101114- 9— ILI LJ a E u �—VNLLS Y-W' m IS-0' o'<m tYT N A N d Ben IpIM xl Ri O IV I trs• r-Id' r-rd' r-Id' ii'-e' Zd Oi• - e'-W' 41• Y I I rr,xa uc esJo mme WWI vm Rrx m� R,[ P®iwr to mT,r me * I I e i � M P.T. 3! aA M. m,. 13/P I I TO TR. WIM J/4' iaa RYHWm im 4N P.T. ATf.1aIEP VM Fa4 m rawupr. SEE T mrc 1aR cawmr A I I I in L� As P1R FWRM IR.aa91W cans. a mpFrluxwAi �ETK 'TM's w BE mer AAQMa STFucrunM. YF10fat5 YEDeFrik^ pialOFD TEAT 11E AmFD BD10roDO 5 Nor INrE� !CL ............... 0 NS � W a _ SSTATE 0 Fl 0 R 10 N //� CAS S......... ....: O /�/�� /O Al ``�1��� CD CD Matthew T. Baldwin P.E. Florida License #64608 END ELEVATION E D ELEV TIO Z WITHour DOOR WITH GARAGE DOOR Rom' • stE snsn.r FOR SUE w (MA. WN them FLOOR FRAMING PLAN m Sheet SSB-1 OF 1