FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Emaj$
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FLi0674-R15
Revision
2017
Approved
Owens Corning
One Owens Corning Parkway
Toledo, Oil 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg-keeler@ovvenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert J.M. Nieminen
PE-59166
PRI Construction Materials Technologies, LLC
01/01/2099
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10674__CC�T 2019 O1_COI NIEMTNEN.pdf
Standard
Year
ASTM D1970
2015
ASTM D3161
2016
ASTM D3462
2010
ASTM D7158
2011
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
oT Proaucts
Method 1 Option D
08/15/2019
08/15/2019
08/21/2019
10/15/2019
FL # Model, Number or Name
10674.1 Owens Corning Asphalt Roofing
Shingles and Starters
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Description
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge
shingles
Installation Instructions
FL10674_gj,5_IL2019 g$ FINAL_EBL_Q�_ASPHALT
SHINGLE _FLjD.674-Rj5Rdlf`
Verified By: Robert ]. M. Nieminen PE - 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL106.7_RI-�_AE_2M_Q$_F-IL`1AL_.FR_0-C_A5 PHALT
SHINGLE5_FL10674-R15.pf
Created by Independent Third Party: Yes
€srck Ptext
Contact Us :: 2601 Blair Stone Road, TaVahassee FL 32322 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. LQpyllght 2007-2013 State of Florida.:: Privacy. Statement :: Accessibility Statement :: Refu 91 Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(7), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. It you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please Uick bgLe_
Product Approval Accepts:
M_ ® W Er M
Credit Card
Safe
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit 413
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION' f '
Owens Corning Evaluation Report 037940.02.12-R10
One Owens Corning Parkway FL10674-RiS
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 10: 08/15/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2,6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NFMOletc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
?gPS..•Fx'r a :: ('
Robert J.M. Nieminen, P.E. ;f n - �. ram;; The facsimile seal appearing was authorized Robert
�,,,a*y ;;•-••• c^a" Nieminen, P.E. on OS/15/2s)14. This does not serve as an
Florida Registration No. 59166, Florida DCA ANE1983
9 electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOJetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO Ietc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW I etc, nor Robert Nieminen, P.E. ate, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02018, NEMO ETC, LLC
a- 04o, �
NEMO I etc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 6t" Edition (2017) Florida Building Code and Florida
Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
Pro ert
Standard
Year
1507.2.4, R905.2.3
Physical Properties
ASTM D1970
2015
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
Entity
Examination
Reference
Date
Owens Corning
Declaration
Equivalency Declaration
08/06/2019
PRI(TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-112453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126S32
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
4.1 ACCESSORY STARTERS:
4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets
ASTM D3462.
4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SIBS modified bitumen starter strip,
nominal 7.2-inch wide x 33-ft 4-inch long roll, for use with asphalt shingles. Meets ASTM D1970.
4.2 ASPHALT SHINGLES:
4.2.1 Classic" and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles. Meets ASTM D3462.
4.2.2 Berkshire" are fiberglass reinforced, 4-tab asphalt roof shingles. Meets ASTM D3462.
4.2.3 Duration', TruDefinition' Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection,
TruDefinition' Oakridge% Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof
shingles. Meets ASTM D3462.
4.3 Hip & RIDGE SHINGLES:
4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdge° Hip & Ridge
Shingles and WeatherGuard' HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
Meets ASTM D3462.
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificote afAutharization #32455 6- EDrrION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS
Owens Corning Asphalt Roof Shingles Revision 10. 08/15/2019
Page 2 of 10
0 4k I)
4�
MEMO I etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, Or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report,- refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Wind Classification:
5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones
UP to Vasd = 150 mph (Vuh =194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip
& ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vasd = 150 mph (V It = 194 mph). Refer to
Section 6 for installation requirements to meet this wind rating.
5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or 13905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SIRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
F411lrndodavenam Dock
Self -adhered
Weathe,La k'
- sarderlaYn3ent
.... Drip edge
Nails "led
2 =3- from eave
> t
ina4111f t " Self. alingadhesive
Starter Strip _ "ion" along cave
shin{¢, with 1
$' rwnoaed Starter Strip Ain*—erisangs eaves and
Psi�v4ead•pment �� sa-��rea
weausess�s3
wiq«hYmnu
l "
p�hpadp•
mro
K'
i �a3ad
- r_3' hom raa•
has•IfmrStann SsriP Hu• 5'r++'��+�«ire
rmhs'rmseysA—.....-.-.� pas-rb��a a►+a care
5,nn Wv FI.s eranmas eaves anRrakes V4--34'
Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate of Authorization432455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 3 of 10
NNEMO I etc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Deck
Drip edge
Underlayment
�
Drip edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
Self sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
Berkshire* shingles require minimum five (5) nails per shingle.
WeatherGuard" HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 ClassicO & Supreme:
Normal Mansard or Area Para
Wind Areas High Wind de:vanes y
Area pare vientos normnies Areas vientos fuertas
1' (A) V. r1. 2' �(B Z' 7"7
14' 1 T �
VEX re
Exposicidn
Figure 4: Minimum Nailing, Classic & Supreme
(Standard Size)
Normal Mansard or Area pars
Wind Areas High Wind desvanes y
Aran pars vientos nornmias Areas vientos fuertas
72 421
6 5/W Exposure
Exposit➢dn
Figure 5: Minimum Nailing, Classic & Supreme
(Metric Size)
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate of Authorization #3.M55 6T" EDITION (20171 FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 4 of 10
6.3.1.2 Berkshire®:
Sealant ship
La tirade s6h&
Figure 6: 5-Nail Pattern, Berkshire
Sealant strip
is lira de selfador
a
i
2' Asphalt roofing cement
Cwwrito de techodo astaito
ONEMOjetC.
Figure 7: 6-Nail Pattern, Berkshire
Figure S: Mansard or Steep Slope Pattern, Berkshire
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate of Authorization #32455 61H EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1315
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 5of10
0 ALI"
WIT
NEMO j etc.
6.3.1.3 Duration®, TruDefinitionO Duration, DurationO Premium Cool & TruDefinitiori Duration* Designer Color Collection:
Figure 9: Standard 4-Nail Pattern, Duration
6-Nail Fastening Pattern
Sumlowt, fastening area width
Nail, iryplcal
12" I I. 12 -i1.'
Figure 10* 6-Nail Pattern, Duration
Fastening for Slopes Greater Than 21:12
SureNailna_ fastening area width
Nall, Typical
1 12" 1"
�as.rn�tu�rkntF Sn, N • �i ut5 �vruwJ*sue i awens Cum.-•. •• xW &..a..'—_... _..
6-118" ssra^
Four 1" Spots of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern, Duration
NENIO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate ofAuthoritation #32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10. 08/15/2019
Page 6 of 10
ONEMOletc.
6.3.1.4 TruDefinition*Oakridee®, Oakridte'9:
4 Nail Pattom
Esquema co►r Q clai<os
5 W Exposure Nails5 518" Exposure
Eeposich* do 551Cp4g. stows Exposicion de 5516?pu1q.
Figure 12: Standard 4-Nail Pattern, Oakridge
6 Nail Pattem
Esquema con 6 clavos
Imo- Q Fes— 12"Nails
5618" Exposure cfavos 5 518" Exposure
Expmicdan de 6619pu1g. Exposicfcn de 55/8pula.
Figure 13: 6-Nail Pattern, Oakridge
Figure 14. Mansard or Steep -Slope Pattern, Oakridge
MEMO ETC, LLC Evaluation Report 037940.02.12-R1O
CertifrcateofAuthorizotion #32455 6rn EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 09/15/2019
Page 7 of 10
6.3.1.5 WeatherGuard® HP:
16h CI# a
5 5 6' E wq v s,je
Exoositibi tl� 5 5 B w�g.
Figure 15: 6-Nail Pattern, WeatherGuard HP
6Nal Pattern
Esquerna con 6 clavos Nail 6 118" from bottom
of shingle
Gave a 6 118 pul , de la
5 5T Exposure 6 Fasteners parte inferior de la teja
Exposicibn de 5 518 pulg. 6 sujetadores
Four 1' Spots of AsphaEt Roof Cement
Cuetro puntos de eemento de Who de asfdto de 1 pulgada
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
ONEMOjetc.
6.4 Hip & RIDGE SHINGLES:
6.4.1 installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire' Hip and Ridge Shingles with Sealant and DuraRidgel Hip & Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
WeatherGuard® HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4)
nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
NEW ETC, LLC Evaluation Report 037940.02.12-RSO
Certificate of Authorization #32455 6"' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 8 of 10
OI EMO j etc.
6.4.1.1 Berkshire® Him &fie with Sealant and Durallidgee Hip & Ridge Shingles with Sealant:
Fig. A
Prevailing wind Direction
— Direction del viento predominante
Figure 17: Isometric View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip & Ridge Shingles:
Fig. A `� 4
PMV41[kv WM
>irecion
!tails 4 i
p i !
1 I
+
Exposure
� 1
Figure 18: Plan View, Berkshire and OuraRidge
Fig. C Hip & Ridge Shingle Fastening
Tap VleEv
Nags Malls
'
2" 2,
t" �1
V. Exposure
Figure 19: Isometric View, WeatherGuard HP Hip & Ridge Figure 20: Plan View, WeatherGuard HP Hip & Ridge
NEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate ojAuthorization #314ss 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R1S
Owens Coming Asphalt Roof Shingles Revision 10: 08/15/2019
Page 9 of 10
6.4.1.3 ProEdgel Hip & Ridge Shingles:
Prevailing
Wind Direction sed"t Strip
6" Exposure
r,
Fasten 71W
Cover Exposed
Fasteners with
Roof Cement
Figure 21: Isometric View, ProEdge
ONEMOjetc.
Standard --
(Fastening
Pattern
Sealant
7 h" 6" Exposure
1
(r 12"
Figure 22: Plan View, ProEdge
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1 / R905.2.6.1.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3
QA requirements.
PRI Construction Materials Technologies, LLC— QUA9110 ; 813 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate of Authorization #32455 6"' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 10 of 10