Loading...
HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: WYME, biz& C,0KP Date: I7 o (Print or type) 5PAN159 PIKE5 Address:SILVER DAK PR poR-r ;J ocie FL ONE M tl >P Physical Location of liforne) 9Lo.,r&A0a 131 ( A lrEp �oZ d.�}o CAVA L 16 R Year / Manufacturer Ht9MES Seria '�SGiEDo1 / 3 S$ HUD Plate # (>Co (! f a a yDa Width —;)'Li Length F> Single Double V101, Wind Zone_, C = In Compliance N = Not in Compliance Fire Safety / Electrical 1. Smoke Detector: Installed—%t*. Missing G 2. Electrical System Checked: Exposed Wiring —Other 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other_ L 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ --AC, 5. Electrical Ground: Chassis Main Panel Gas Pipe RcvisW 3/9/05 Page I of 3 Construction C 1. Exit Doors Operable: Front Back Other C 2. Exit Door Locks: Missing Inoperable C 3. Egress windows: Missing Inoperable C 4. Windows: Broken Glass Inoperable sL 5. Screens: Missing Damaged_ 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing _ Loose _ Damaged_ C 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other C 9. Leaks Apparent: Ceiling _ Doors Floor _ Roof 10. Vertical tie -down straps: Missing _ Short _ Damaged_ 11. Structural modifications since manufactured: YES_ NOj[ 12. Walls: Structurally Unsound _ Loose _ Weather tight Plumbing C 1. Trap: Missing Not connected Other C 2. Plumbing fixtures: Missing Not installed _ Not Vented 3. Relief Valve: Missing Inoperable Other C 4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs Use of fittings Not capped_ Heating and Air Conditioning r 1. Heating Appliances: Missing Not Connected Other C 2. Deleted Heating/AC system: Not installed Other i3. Thermostat: Missing Inoperable C 4. Air registers: Missing Inoperable L 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 C 6. Gas furnace Water heater vent: Missing Loose C_ 7. Return Air: To Furnace To A/C From rooms i B. Range: Vent Hood - 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (500/6) or more damaged or deteriorated? YES NO_V"_ 2. Will a remodeling permit be required? YES NO_V/' The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: 74 0 RD Inspected By: JWOOD CC, C, _,__ Slgn lure required �Phone Number. (�/` 4) THEIR SEAL. License# 3 L 3JU Page 3 of 3 �-i� aoav Engineers Seal STEVEN G. WOOD, P.E. ]FL LICENSE 34398 960 SULTAN DR pGRT ST LUCIE, FL