HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 3 Block 2 Waterstone 2265 AGL
Builder Name: ADAMS HOMES
Street: 8309 Cdstelle Court
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1994.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1378.30 ft2
b. Frame - Wood, Exterior
R=13.0 407.83 ft'
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 208.00 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2281.0 soft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2281.00 ft'
6. Conditioned floor area above grade (W) 2281
b. N/A
R= ft'
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(306.4 sqft.) Description Area
a. Sup: Attic, Rat: Main, AH: Main
6 456.2
a. U-Factor: Dial, U=0.33 166.06 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.50
c. U-Factor: Dbl, U=0.55 51.11 ft'
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 18.33 ft'
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 5.808 ft.
Area Weighted Average SHGC: 0.309
14. Hot water systems
8. Floor Types (2281.0 soft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ft2
b. Conservation features
EF: 0.940
It. N/A R= ft2
None
'
c. N/A R= ft2
15. Credits
Pslat
Glass/Floor Area: 0.134 Total Proposed Modified Loads: 68.11
PASS
Total Baseline Loads: 72.46
1 hereby certify that the plans and specifications covered by
Review of the plans and
ST9jcp
this calculation are in complian he Florida ergs.
specifications covered by this
OQItHE
Code.
calculation indicates compliance
��'
y"r' �ir,�"!I ' _ A
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 114-n6-20 Winn KPnmany
this building will be inspected for
compliance with Section 553.908
Pv1� d
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida
WME
` \
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
r
4/6/2020 4:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHFCKI_IST RFPnRT
1
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
- Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 3 Block 2 Waterston 226 Bedrooms: 4
User Conditioned Area: 2281
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 16
Block/Subdivision: PSL- Bayshore
PlatBook:
Street: 8309 Cristelle Court
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2281 20529
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
2281 20529 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulalio Main 206.2 ft 0
2281112 ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Bar Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2551 ft2 572 ftMedium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2281 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2281 ft2 0.11 Wood
4/6/2020 4:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar Below
0
1
W
Exterior
Frame - Wood
Main
13
10
2
8 0
81.3 ft'
0
0.23 0.6
0
2
W
Exterior
Concrete Block - Int Insul
Main
4.1
38
7
10 0
385.8 ft2
0
0 0.6
0
3
S
Exterior
Frame - Wood
Main
13
4
6
10 0
45.0 ft'
0
0.23 0.6
0
_ 4
S
Exterior
Concrete Block - Int Insul
Main
4.1
28
6
10 0
285.0 ft'
0
0 0.6
0
-6
E
Exterior
Frame - Wood
Main
13
6
9
8 0
54.0 ft2
0
0.23 0.6
0
6
E
Exterior
Concrete Block - Int Insul
Main
4.1
50
3
8 0
402.0 ft2
0
0 0.6
0
-7
NE
Exterior
Frame - Wood
Main
13
3
10
10 0
38.3 ft'
0
0.23 0.6
0
_ 8
NE
Exterior
Concrete Block - Int Insul
Main
4.1
0
5
10 0
4.2 ft2
0
0 0.6
0
9
N
Exterior
Frame - Wood
Main
13
18
11
10 0
189.2 ft'
0
0.23 0.6
0
10
N
Exterior
Concrete Block - Int Insul
Main
4.1
37
8
8 0
301.3 ft2
0
0 0.6
0
11
-
Garage
Frame - Wood
Main
13
26
0
8 0
208.0 ft'
0
0.23 0.01
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
Main
None
.25
3
6 8
20 ft'
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W
1
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft'
23 ft 0 in
0 ft 9 in
Drapes/blinds
Exterior 5
2
W
2
Vinyl Low-E Double
Yes
0.33
0.23
N
32.4 ft'
1 ft 0 in
0 ft 10 In
Drapes/blinds
Exterior 5
3
S
3
Vinyl Low-E Double
Yes
0.33
0.31
N
5.0 ft'
7 ft 8 in
0 ft 6 in
None
None
4
S
4
Vinyl Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 ft 8 in
2 ft 10 in
None
None
5
S
4
Vinyl Low-E Double
Yes
0.33
0.21
N
32.4 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
S
4
Vinyl Low-E Double
Yes
0.33
0.21
N
38.5 ft'
1 ft 0 in
2 ft 10 in
Dmpes/blinds
Exterior 5
7
E
5
Vinyl Low-E Double
Yes
0.55
0.7
N
15.6 ft'
23 ft 0 in
0 ft 9 in
Drapes/blinds
Exterior 5
8
E
6
Vinyl Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
9
E
6
Vinyl Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
10
NE
7
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft2
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
11
N
9
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft'
9 ft 4 in
0 ft 9 In
Drapes/blinds
Exterior 5
12
N
9
Vinyl Low-E Double
Yes
0.33
0.23
N
16.7 W
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
13
N
9
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
14
N
10
Vinyl Low-E Double
Yes
0.33
0.23
N
48.6 ft'
1 ft 0 in
0 ft 1 O in
Drapes/blinds
Exterior 5
4/6/2020 4:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
476 ft-
476 ft'
64 ft 8 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2395.1 131.48 247.28 .1454 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER; 15.5 35 kBtu/hr 1167 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft'
DUCTS
#
LV
-- Supply--
Location R-Value Area
— Return — Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool l
1
Attic 6 456.2ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
4/6/2020 4:27 PM EnergyGaugee USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cool in Jan
HeatinJan
[�rx]'J Feb
Feb
r[�X1]J Mar
Mar
] A r
E ] Apr
[
[
Ma
i May
[X] Jun
[ ] Jun
[X] Jul
[ ) Jul
[X] Au
r 1 Aug
rX
Se
Sep
r ,Oct
f 1 Oct
Nov
Nov
[ ] Dec
(X] Dec
VentingJan
IIII 1111 Feb
l l
IIII�XXXIIII Mar
lxl
IXl A r
l
111 May
l) Jun
[) Jul
111 Au
E 111
Se
[[[XXXIII Oct
X
X Nov
[ ]Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating(WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibsls
.ft.
0 ft'
0 ft
0.3
Main
41612020 4:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
35.0
a) Split system SEER
15.5
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
2281
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.367
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.309
14. Heating system: Capacity
34.6
c) Area
7c.
306.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighled average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
90.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
1ld.
No
e) Multizone heating credit
I) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signat7zs. Date:
Address of New Home: 8309 Cristelle Court City/FL Zip: Fort Pierce, FL 34951
4/6/2020 4:27:52 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1