FI ORIDA ENERGY EFFICIENCY CODE FOR"BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: LOT #37 WATERSONG
BuilderName:
Street: 4824 WATERSONG WAY
Permit Office: ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL,
PermitNumber:
Owner:
Jurisdiction:
DesignLocallon: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New(From Plans)
9. Wall Types (4887.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Polystyrene Bead AggreR=11.0 4797.00ft'
b. Frame -Wood, Adjacent
R=11.0 90.00 ft'
3. Number of units, If multiple family 1
c. N/A
R= fi'
4. Numberof Bedrooms 4
d.N/A
R= ft'
10.Celling Types (2035.0 sqft.)
Insulation Area
5. Is thisaworst case? No
a. Roof Deck(Unvented)
R=22.0 2035.00ft2
6. Conditioned floor area above grade(ft') 4223
b. N/A
R= ft'
Conditioned floorarea belowgrade(ft') 0
c. N/A
'R= ft'
11. Ducts
R ft'
7. Windows(979.0 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 325
a. U-Factor: Dbl, U=0.79 603.00 ft'
b. Sup: Attic, Ret: Attic, AH: Attic
6 275
SHGC: SHGC=0.28
b. U-Factor: Dbi, U=1.06 254.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.39
a. Central Unit
34.2 SEER:16.00
b. Central Unit
46.5 SEER:16.00
c. U-Factor: Dbl, U=1.06 80.00 ft2
SHGC: SHGC=0.30
13. Heating systems
kBlu/hr Efficiency
d. U-Factor: other(see details) 42.00 ft'
a. Electric Strip Heat
34.0 COP:1.00
SHGC: other(see details)
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted AverageOverhang Depth: 4.431 ft.
Area Weighted Average SHGC: 0.305
14. Hotwatersystems
a. Electric
Cap:80 gallons
8. FloorTypes (1608.5 sqft.) Insulation Area
EF: 0.950
a. Raised Floor R=19.0 800.50 ft'
b. Conservation features
b. Slab -On -Grade Edge Insulation R=0.0 736.00 ft'
None
c. other(see details) R= 72.00 ft'
15. Credits
Pstat
Glass/Floor Area: 0.232 Total Proposed Modified Loads: 143.13
PASS
Total Baseline Loads: 144.23
1 hereby certify that the plans and specifications covered by
Review of the plans and
BTgr�
this calculation are in compliance with the Florida Energy
specifications covered by this
�F'TUE
ti __ _ , O�
Code.
calculation indicates compliance
4%
rO
with the Florida Energy Code.
+mrrb;-• •;; 4a
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby'certify that this buildi design , is in compliance
Florida Statutes.
COD
with the Florida Energy Cc
WE igJ
OWNERIAGENT:
BUILDING OFFICIAL:
DATE: '� ° ��
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
Fit , C
5/5/20207:26 AM EnergyGauge®USA 6.0.02(Rev.1)- FlaRes2017 FBC 6th Edition(2017) Compliant Software Pagel of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
LOT #37 WATERSONG
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
ConditionedArea:
4223
Lot#
OwnerName:
Total Stories:
3
Block/Subdivision:
#of Units:
1
Worst Case:
No
PlatBook:
BuilderName:
RotateAngle:
0
Street:
4824 WATERSONG W
Permit Office:
ST. LUCIE COUNTY
CrossVentilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
ST. LUCIE COUNTY,
FamilyType:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
DesignTemp
Int Design Temp
Heating
Design Daily Temp
v Designi-ocation
TMY Site
97.5%
2.5%
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
UNIT 1
2335
25218.8
2
UNIT2
1888
18056.2
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
FLEX ROOM
297
2673
No
0
1
Yes
Yes
Yes
2
LAUND.
65
585
No
0
1
Yes
Yes
Yes
3
CABANA
57
513
No
0
1
Yes
Yes
Yes
4
STAIR
91
855.4
No
0
1
Yes
Yes
Yes
5
FOYER
244
2440
No
0
1
Yes
Yes
Yes
6
ELE
25
250
No
0
1
No
Yes
Yes
7
GREAT ROOM
564
6322.4
No
0
1
Yes
Yes
Yes
8
STAIRWAY
243
2916
No
0
1
Yes
Yes
Yes
9
KITCHEN
300
3600
Yes
0
1
Yes
Yes
Yes
10
LAUNDRY
82
984
No
0
1
Yes
Yes
Yes
11
BEDROOM 4
190
2280
No
1
1
1
Yes
Yes
Yes
12
ELEVATOR
25
300
No
0
1
No
Yes
Yes
13
BATH 4
60
600
No
0
1
Yes
Yes
Yes
14
POWDER
72
720
No
0
1
Yes
Yes
Yes
15
A/C 2
20
180
No
0
1
No
Yes
Yes
16
MASTER BATH
200
1880
No
0
1
Yes
Yes
Yes
17
TOILET
24
225.6
No
0
1
Yes
Yes
Yes
18
M WIC
83
780.2
No
0
1
Yes
Yes
Yes
19
WIC
48
451.2
No
0
1
No
Yes
Yes
20
WIC 2
42
394.8
No
0
1
Yes
Yes
Yes
21
MASTER SUITE
515
5150
No
0.
1
1
Yes
Yes
Yes
5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
Infil ID
Finished
Cooled
Heated
22
BEDROOM 2 195 1833
No 0
1
1
Yes
Yes
Yes
23
HALLWAY 228 2143.2
No 0
1
Yes
Yes
Yes
24
STARIWAY. 104 977.6
No 0
1
Yes
Yes
Yes
25
BATH 2 50 470
No 0
1
Yes
Yes
Yes
26
WIC 3 50 470
No 0
1
Yes
Yes
Yes
27
BEDROOM 3 168 1579.2
No 0
1
1
Yes
Yes
Yes
28
BATH 3 50 470
No 0
1
Yes
Yes
Yes
29
OFFICE 131 1231.4
No 0
1
Yes
Yes
Yes
FLOORS
# FloorType Space
Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation FLEX ROOM
53ft 0
254 ft2
_--_
0
1
0
2 Slab-On-GradeEdgelnsulation LAUND.
18ft 0
65 ft2
----
0
1
0
3 Slab -On -Grade Edgelnsulation CABANA
loft 0
57 fF
----
0
1
0
4 Slab -On -Grade Edge Insulation STAIR
lift 0
91 ft2
--_-
0
1
0
5 Slab -On -Grade Edge Insulation FOYER
29It 0
244 ft2
----
0
1
0
6 Slab -On -Grade Edge Insulation ELE
tft 0
25 1`12
----
0
1
0
7 Raised Floor STAIRWAY
---- ----
56 fF
19
0
0
1
8 Raised Floor KITCHEN
---- ----
90 ft'
19
0
0
1
9Raised Floor KITCHEN
---- ----
35 ft2
19
0
1
0
10Raised Floor LAUNDRY
---- ----
72 fN
0
0
0
1
11Raised Floor LAUNDRY
---- --_-
10 ft2
19
0
1
0
12Raised Floor BEDROOM 4
---- ----
190 ft2
19
0
0
1
13Ralsed Floor ELEVATOR
---- ----
25 ft2
19
0
0
1
14Raised Floor BATH 4
---- ----
60 ft2
19
0
0
1
15Raised Floor POWDER
---- ----
8ft2
19
O
0
1
16Raised Floor POWDER
---- ---_
55 it-
19
0
1
0
17Raised Floor A/C 2
---- ----
5 112
19
0
0
1
18Raised Floor MASTER BATH
---- ----
28 ft2
19
0
1
0
19Ralsed Floor MASTER SUITE
---- ----
4.5 W
19
0
1
0
20Ralsed Floor BEDROOM 3
---- ----
112 ft2
19
0
1
0
21Raised Floor BATH
---- ----
40 iF
19
0
1
0
5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
FloorType Space Perimeter PedmeterR-Value
Area
JolstR-Value
Tile
Wood Carpet
22Raised Floor OFFICE ----
----
81 ft.
19
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 2428 ft2
0 ft' Unfinishe
N
0.5
No 0.7
No 22
30.3
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Unvented
0
2096 ft-
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frec
Truss Type
1
UnderAttic(Unvented) FLEX ROOM
0
Blown
101 ft'
0.1
Wood
_
2
UnderAttic(Unvented) LAUND.
0
Blown
25 ft-
0.1
Wood
3
UnderAttic(Unvented) GREAT ROOM
0
Blown
36 ft'
0.1
Wood
4
UnderAftic(Unvented) MASTER BATH
0
Blown
192 ft-
0.1
Wood
5
UnderAftic(Unvented) TOILET
0
Blown
24 ft-
0.1
Wood
6
UnderAttic(Unvented) MWIC
0
Blown
83 ft'
0.1
Wood
7
UnderAttic(Unvented) WIC
0
Blown
48 ft2
0.1
Wood
8
UnderAttic(Unvented) WIC
0
Blown
42 ft-
0.1
Wood
9
UnderAttic(Unvented) MASTER SUITE
0
Blown
515ft'
0.1
Wood
10
UnderAttic(Unvented) BEDROOM
0
Blown
195 ft2
0.1
Wood
11
UnderAttic(Unvented) HALLWAY
0
Blown
228W
0.1
Wood
12
UnderAttic(Unvented) STARIWAY.
0
Blown
104 its
0.1
Wood
_
13
UnderAttic(Unvented) BATH
0
Blown
50 ft'
0.1
Wood
_
14
UnderAttic(Unvented) WIC
0
Blown
50 R'
0.1
Wood
15
UnderAttic(Unvented) BEDROOM
0
Blown
168 ft'
0.1
Wood
_
16
UnderAftic(Unvented) BATH 3
0
Blown
50 IF
0.1
Wood
17
UnderAttic(Unvented) OFFICE
0
Blown
124 ft'
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
_ 1
N
Exterior Concrete Block- PolystyrEbEX ROOM
11 18
0 9
0
162.0 ft-
0
0
0.3
0
2
E
Exterior Concrete Block- PolystyrEbEX ROOM
11 30
0 9
0
270.0 ft-
0
0
0.3
0
_3
S
Exterior Concrete Block- PolystyrEbEX ROOM
11 5
0 9
0
45.0 ft-
0
0
0.3
0
4
N
Exterior Concrete Block- PolystyreriaAU ND.
11 10
0 9
0
90.0W
0
0
0.3
0
5
E
Exterior Concrete Block- Polystyrenh4U ND.
11 1
0 9
0
9.0 ft.
0
0
0.3
0
6
W
Exterior Concrete Block- Polystyrerla4U ND.
11 7
0 9
0
63.0 ff
0
0
0.3
0
7
W
Exterior Concrete Block- Polystyrer®48ANA
11 10
0 9
0
90.0 ff
0
0
0.3
0
8
W
Exterior Concrete Block- Polystyren(STAI R
11 11
0 9
0
99.0 ft'
0
0
0.3
0
5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8
V
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Spate
Cavity
Width
Height
Sheathing Framing
Solar
Below
_ 9
S
Exterior
Concrete Block-PolystyrenEOYER
11
8
0
9
0
72.0 ft'
0
0
0.3
0
10
W
Exterior
Concrete Block-PolystyrenEOYER
11
21
0
9
0
189.0 ft'
0
0
0.3
0
11
N
Exterior
Concrete Block-Polystyi@REAT ROO
11
21
0
12
0
252.0 ft-
0
0
0.3
0
12
NE
Exterior
Concrete Block-Polystyr@REAT ROO
11
9
11
12
0
119.0 ft'
0
0
0.3
0
13
E
Exterior
Concrete Block-PolystyGREAT ROO
11
14
0
12
0
168.0 ft'
0
0
0.3
0
14
W
Exterior
Concrete Block-PolystyGREAT ROO
11
21
0
12
0
252.0 ft'
0
0
0.3
0
15
W
Exterior
Concrete Block- PolystyrdhTAIRWAY
11
24
0
12
0
288.0 ft-
0
0
0.3
0
16
E
Exterior
Concrete Block -PolystyreKdTCHEN
11
14
0
12
0
168.0 ft'
0
0
0.3
0
17
E
Exterior
Concrete Block -PolystyrehAUN DRY
11
9
0
12
0
108.0 ft'
0
0
0.3
0
18
E
Exterior
Concrete Block- PolystyrBBDROOM 4
11
13
0
12
0
156.0T
0
0
0.3
0
19
S
Exterior
Concrete Block- PolystyRSDROOM4
11
14
0
12
0
168.0 ft'
0
0
0.3
0
20
S
Exterior
Concrete Block -PolystyrenBATH4
11
5
0
12
0
60.0 ft.
0
0
0.3
0
21
W
Exterior
Concrete Block-PolystyrenSATH 4
11
4
0
12
0
48.0 ft-
0
0
0.3
0
22
S
Exterior
Concrete Block- PolystyreNOWDER
11
9
0
12
0
108.0 ft'
0
0
0.3
0
23
W
Exterior
Concrete Block-PolystyreNOWDER
11
8
0
12
0
96.0 ft'
0
0
0.3
0
24
N
Exterior
Concrete Block -PolystyWASTER BA
11
14
0
9
0
126.0 ft'
0
0
0.3
0
25
E
Exterior
Concrete Block-PolystyrMASTER BA
11
6
0
9
0
54.0 ft'
0
0
0.3
0
26
W
Exterior
Concrete Block-PolystyrMMTER BA
11..
16
0
9
0
144.0 ft'
0
0
0.3
0
27
W
Exterior
Concrete Block- PolystyrenEOILET
11
4
0
9
0
36.0 ft'
0
0
0.3
0
28
W
Exterior
Concrete Block-PolystyrenaM WIC
11
12
0
9
0
108.0 ft.
0
0
0.3
0
29
E
Exterior
Concrete Block -PolystyrendNlC2
11
6
0
9
0
54.0 ft'
0
0
0.3
0
30
N
Exterior
Concrete Block-PolystyfdMTER SUI
11
14
0
9
0
126.0ft'
0
0
0.3
0
31
E
Exterior
Concrete Block-Polystyf®ASTER SUI
11
20
0
9
0
180.0 ft'
0
0
0.3
0
32
E
Exterior
Concrete Block- PolystyRBDROOM 2
11
13
0
9
0
117.Oft-
0
0
0.3
0
33
W
Exterior
Concrete Block- PolystyreHALLWAY
11
7
0
10
0
70.0 ft'
0
0
0.3
0
34
W
Exterior
Concrete Block- PolystyrHTs4R IWAY.
11
13
0
9
0
117.0ft'
0
0
0.3
0
35
E
Exterior
Concrete Block-PolystyrenBATH 2
11
5
0
9
0
45.0 ft'
0
0
0.3
0
35
E
Exterior
Concrete Block-PolystyrendNlC 3
11
5
0
9
0
45.0 ft'
0
0
0.3
0
37
E
Exterior
Concrete Block- PolystyS6DROOM3
11
12
0
9
0
108.0 ft'
0
0
0.3
0
38
S
Exterior
Concrete Block-PolystyrB6DROOM 3
11
14
0
9
0
126.0 ft'
0
0
0.3
0
39
S
Exterior
Concrete Block- PolystyrenBATH3
11
5
0
9
0
45.0 ft'
0
0
0.3
0
40
W
Exterior
Concrete Block- PolystyrenBATH 3
11
3
0
9
0
27.0 ft-
0
0
0.3
0
41
S
Exterior
Concrete Block-PolystyrenSFFICE
11
9
0
9
0
81.0 ft-
0
0
0.3
0
42
W
Exterior
Concrete Block- PolystyrerOFFICE
11
12
0
9
0
108.0ft'
0
0
0.3
0
43
N
Garage
Frame -Wood OFFICE
11
10
9
90.0W
0
0.23
0.3
0
515/20207:26 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5of8
r
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown lstheentered, Proposed orientation.
Wall
Overhang
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
N
1
Vinyl
Low-EDouble
Yes
1.06
0.39
Y
80.0 ft2
4 It 0 in
0 ft 0 in
Drapes/blinds
Exteriorl
2
E
2
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
40.0 ft'
2 It 0 in
0 It 0 in
None
None
_ 3
N
4
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
24.0 IF
2ft Din
0ft0 in
None
None
_ 4
S
9
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
48.0 ft2
5 ft 0 in
3 it 0 in
None
None
5
W
10
Vinyl
Low-E Double
Yes
0.79
0.28
Y
40.0 ft'
2ft Din
25It0 in
None
None
_ 6
N
11
Vinyl
Low-E Double
Yes
1.06
0.39
Y
112.0 ft-
8ft0in
0It0 in
None
None
7
NE
12
Vinyl
Low-EDouble
Yes
1.06
0.39
Y
62.0 ft2
10 It 0In
0 It 0 in
None
None
8
E
13
Vinyl
Low-EDouble
Yes
0.79
028
Y
56.0 ft'
2ft0in
13It0 in
None
None
_ 9
W
14
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
42.0 ft2
2 ft 0 in
13 It 0 in
None
None
10
W
15
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
24.0 ft2
2 It 0 in
13 ft 0 in
None
None
11
E
16
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
18.0 fF
2 It 0 in
13 ft 0 in
None
None
12
E
17
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
14.0 ft2
2 ft 0 in
13 ft 0 in
None
None
13
E
18
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
28.0 ft2
2 It 0 in
13 It 0 in
None
None
14
S
19
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
40.0 ft2
5 It 0 in
2 It 0 in
Drapes/blinds
Exteriorl
15
S
19
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
5.0 112
5 ft 0 in
13 it 0 in
None
None
_ 16
S
19
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
8.0 ft2
2ft 0In
14 It 0 in
None
None
17
S
20
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
8.0 ft2
2ft 01n
14It0 in
None
None
_ 18
W
23
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
8.0 fF
2 It 0 in
13 It 0 in
None
None
19
N
24
Vinyl
Low-E Double
Yes
0.22
0.17
Y
18.0 ft2
2 It 0 in
1 It 5 in
None
None
20
N
24
Vinyl
Low-EDouble
Yes
0.22
0.17
Y
24.0 ft-
2 it 0 in
1 It 5 in
None
None
21
W
27
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
10.0 ft2
2 ft 0 in
1 it 5 in
None
None
22
N
30
Vinyl
Low-E Double
Yes
1.06
0.3
Y
80.0 ft2
8 ft 8 in
1 It 5 in
None
None
23
E
31
Vinyl
Low-E Double
Yes
0.79
0.28
Y
20.0 ft2
2 it 0 in
1 ft 5 in
None
None
_ 24
E
32
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
20.0 ft2
2 It 0 in
1 ft 5 in
None
None
25
W
33
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
20.0 ft2
2 ft 0 in
1 R 5 in
None
None
26
E
35
Vinyl
Low-E Double
Yes
0.79
0.28
Y
10.0 IF
2 ft 0 in
1 it 5 in
None
None
_ 27
E
37
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
20.0 ft2
2 it 0 in
1 ft 5 in
None
None
_ 28
S
38
Vinyl
Low-EDouble
Yes
0.79
0.28
Y
40.0 ft2
5 It 0 in
1 R 5 in
None
None
29
S
38
Vinyl
Low-E Double
Yes
0.79
0.28
Y
10.0 112
2It0 in
IIt5 in
None
None
30
S
39
Vinyl
Low-E Double
Yes
0.79
0.28
Y
10.0 ft2
2 R 0 in
1 R 5 in
None
None
31
S
41
Vinyl
Low-E Double
Yes
0.79
0.28
Y
40.0 112
5 It 0 in
1 ft 5 in
None
None
GARAGE
#
FloorArea
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ft2
400 ft2
loft
9 ft
19
5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA Eq LA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000326
3606.3 197.98 372.33 .1933 5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COPA 34 kBtu/hr
COPA 27 kBlu/hr
1
2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR
Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Single SEER: 16 34.2 kBtu/hr 1026 cfm 0.85
Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.85
1
2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 80gal 60.9gal 120deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # CompanyName
Collector Storage
System Model# CollectorModel# Area Volume
FEF
None None
ft'
DUCTS
/
V #
--Supply---
Location R-Value Area
---Return--- Air CFM 25 OFM25
Location Area LeakageType Handler TOT OUT QN
RLF
HVAC#
Heat Cool
1
2
Attic 6 325ft'
Attic 6 275ft'
Attic
Attic
75 ft' DefaultLeakage Attic (Default) c(Default) c
95 ft' Defauldeakage Attic (Default) c(Default) c
1 1
2 2
TEMPERATURES
Programabl[eT]hermostat::[ ]]Y [[ ]]
Heating 4X] Jan [X] Feb [X] Mar
Venting 1 Jan II 11 Feb [[XX]] Mar
Ceiling Fans: 4f }1 [X] ] ]
Apr [ ]May Jun [ ]Jul 4X] Aug 4X] Sep O t
l[l 1 Jun I 1 Jul j 1 Aug I 1 Sep
j[Xj]
[X] Nov
ec
[[X]] Dec
[ ] Dec
5/5120207:26 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 7of8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
56
66
Heating(WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(81bs/sq.ft.
0 ft'
0 ft
0.3
FLEX ROOM
Default(Blbs/sq.ft.
ft'
It
0.3
LAUND.
Default(Sibs/sq.ft.
ft'
ft
0.3
CABANA
Default(Blbs/sq.ft.
ft'
It
0.3
STAIR
DeMult(8lbs/sq.ft.
ft'
It
0.3
FOYER
Default(8lbs/sq.ft.
ft-
It
0.3
ELE
Default(81bs/sq.ft.
ft.
ft
0.3
GREAT ROOM
Default(8lbs/sq.ft.
ft'
ft
0.3
STAIRWAY
Default(Blbs/sq.ft.
ft'
It
0.3
KITCHEN
Default(81bs/sq.ft.
fl'
It
0.3
LAUNDRY
Default(8lbs/sq.ft..
fl'
ft
0.3
BEDROOM 4
Default(8lbs/sq.ft.
ft'
It
0.3
ELEVATOR
Default(8lbs/sq.ft.
fN
It
0.3
BATH 4
Default(8lbs/sq.ft.
fl'
It
0.3
POWDER
Default(8lbs/sq.ft.
ft'
ft
0.3
A/C2
Default(8lbs/sq.ft.
ft'
It
0.3
MASTER BATH
Default(Blbs/sq.ft.
ft'
ft
0.3
TOILET
Default(Slbs/sq.ft.
ft'
ft
0.3
M WIC
Default(81bs/sq.ft.
ft'
It
0.3
WIC
Default(Blbs/sq.ft.
ft'
It
0.3
WIC
Default(Slbs/sq.ft.
ft'
ft
0.3
..
MASTER SUITE
Default(Blbs/sq.ft.
ft'
It
0.3
BEDROOM 2
Default(81ba(sq.ft.
ft'
It
0.3
HALLWAY
Default(8lbs/sq.ft.
ft'
it
0.3
STARIWAY.
Default(8lbs/sq.ft.
ft'
It
0.3
BATH 2
Default(81bs/sq.ft.
ft-
It
0.3
WIC
Default(8lbs/sq.ft.
ft'
ft
0.3
BEDROOM 3
Default(8lbs/sq.ft.
ft'
It
0.3
BATH 3
Default(8lbs/sq.ft.
ft'
It
0.3
OFFICE
515120207:26 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 8of8
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LOT #37 WATERSONG Builder Name:
Street: 4824 WATERSONG WAY Permit Office: ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number:
Owner: Jurisdiction:
_
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
Ceilingiattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation In an dropped ceiling/soffit
Y 9 /soffit
the Insulation and any gaps in the air barrierair shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the topside
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts In narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by Insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be out neatly to fit around wiring
and plumbing In exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
5/5/2020 7:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1.
New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2.
Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3.
No. of units (if multiple -family)
3.
1
4.
Number of bedrooms
4.
4
13. Cooling system: Capacity
80.7
a) Split system SEER
16.0
5.
Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6.
Conditioned floor area (sq. ft.)
6.
4223
d) Room unitIPTAC EER
e) Other
7.
Windows, type and area
a) U-factor:(weighted average)
7a.
0.858
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.305
14. Heating system: Capacity
61.0
c) Area
7c.
979.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8.
Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
88.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9.
Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
varies
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10.
Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
11.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11.
Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the lorida Building Code, Energy Conservation, through the above energy
saving features which will be instal (or ex eeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed n in alled code compliant features.
Builder Signature: Date: 7 0
Address of New Home: 4824 WATERSONG WAY City/FL Zip: ST. LUCIE COUNTY, FL