Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FI ORIDA ENERGY EFFICIENCY CODE FOR"BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: LOT #37 WATERSONG BuilderName: Street: 4824 WATERSONG WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, PermitNumber: Owner: Jurisdiction: DesignLocallon: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New(From Plans) 9. Wall Types (4887.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Polystyrene Bead AggreR=11.0 4797.00ft' b. Frame -Wood, Adjacent R=11.0 90.00 ft' 3. Number of units, If multiple family 1 c. N/A R= fi' 4. Numberof Bedrooms 4 d.N/A R= ft' 10.Celling Types (2035.0 sqft.) Insulation Area 5. Is thisaworst case? No a. Roof Deck(Unvented) R=22.0 2035.00ft2 6. Conditioned floor area above grade(ft') 4223 b. N/A R= ft' Conditioned floorarea belowgrade(ft') 0 c. N/A 'R= ft' 11. Ducts R ft' 7. Windows(979.0 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 325 a. U-Factor: Dbl, U=0.79 603.00 ft' b. Sup: Attic, Ret: Attic, AH: Attic 6 275 SHGC: SHGC=0.28 b. U-Factor: Dbi, U=1.06 254.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.39 a. Central Unit 34.2 SEER:16.00 b. Central Unit 46.5 SEER:16.00 c. U-Factor: Dbl, U=1.06 80.00 ft2 SHGC: SHGC=0.30 13. Heating systems kBlu/hr Efficiency d. U-Factor: other(see details) 42.00 ft' a. Electric Strip Heat 34.0 COP:1.00 SHGC: other(see details) b. Electric Strip Heat 27.0 COP:1.00 Area Weighted AverageOverhang Depth: 4.431 ft. Area Weighted Average SHGC: 0.305 14. Hotwatersystems a. Electric Cap:80 gallons 8. FloorTypes (1608.5 sqft.) Insulation Area EF: 0.950 a. Raised Floor R=19.0 800.50 ft' b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 736.00 ft' None c. other(see details) R= 72.00 ft' 15. Credits Pstat Glass/Floor Area: 0.232 Total Proposed Modified Loads: 143.13 PASS Total Baseline Loads: 144.23 1 hereby certify that the plans and specifications covered by Review of the plans and BTgr� this calculation are in compliance with the Florida Energy specifications covered by this �F'TUE ti __ _ , O� Code. calculation indicates compliance 4% rO with the Florida Energy Code. +mrrb;-• •;; 4a PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby'certify that this buildi design , is in compliance Florida Statutes. COD with the Florida Energy Cc WE igJ OWNERIAGENT: BUILDING OFFICIAL: DATE: '� ° �� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). Fit , C 5/5/20207:26 AM EnergyGauge®USA 6.0.02(Rev.1)- FlaRes2017 FBC 6th Edition(2017) Compliant Software Pagel of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LOT #37 WATERSONG Bedrooms: 4 Address Type: Street Address Building Type: User ConditionedArea: 4223 Lot# OwnerName: Total Stories: 3 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 4824 WATERSONG W Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / DesignTemp Int Design Temp Heating Design Daily Temp v Designi-ocation TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT 1 2335 25218.8 2 UNIT2 1888 18056.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 FLEX ROOM 297 2673 No 0 1 Yes Yes Yes 2 LAUND. 65 585 No 0 1 Yes Yes Yes 3 CABANA 57 513 No 0 1 Yes Yes Yes 4 STAIR 91 855.4 No 0 1 Yes Yes Yes 5 FOYER 244 2440 No 0 1 Yes Yes Yes 6 ELE 25 250 No 0 1 No Yes Yes 7 GREAT ROOM 564 6322.4 No 0 1 Yes Yes Yes 8 STAIRWAY 243 2916 No 0 1 Yes Yes Yes 9 KITCHEN 300 3600 Yes 0 1 Yes Yes Yes 10 LAUNDRY 82 984 No 0 1 Yes Yes Yes 11 BEDROOM 4 190 2280 No 1 1 1 Yes Yes Yes 12 ELEVATOR 25 300 No 0 1 No Yes Yes 13 BATH 4 60 600 No 0 1 Yes Yes Yes 14 POWDER 72 720 No 0 1 Yes Yes Yes 15 A/C 2 20 180 No 0 1 No Yes Yes 16 MASTER BATH 200 1880 No 0 1 Yes Yes Yes 17 TOILET 24 225.6 No 0 1 Yes Yes Yes 18 M WIC 83 780.2 No 0 1 Yes Yes Yes 19 WIC 48 451.2 No 0 1 No Yes Yes 20 WIC 2 42 394.8 No 0 1 Yes Yes Yes 21 MASTER SUITE 515 5150 No 0. 1 1 Yes Yes Yes 5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 22 BEDROOM 2 195 1833 No 0 1 1 Yes Yes Yes 23 HALLWAY 228 2143.2 No 0 1 Yes Yes Yes 24 STARIWAY. 104 977.6 No 0 1 Yes Yes Yes 25 BATH 2 50 470 No 0 1 Yes Yes Yes 26 WIC 3 50 470 No 0 1 Yes Yes Yes 27 BEDROOM 3 168 1579.2 No 0 1 1 Yes Yes Yes 28 BATH 3 50 470 No 0 1 Yes Yes Yes 29 OFFICE 131 1231.4 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation FLEX ROOM 53ft 0 254 ft2 _--_ 0 1 0 2 Slab-On-GradeEdgelnsulation LAUND. 18ft 0 65 ft2 ---- 0 1 0 3 Slab -On -Grade Edgelnsulation CABANA loft 0 57 fF ---- 0 1 0 4 Slab -On -Grade Edge Insulation STAIR lift 0 91 ft2 --_- 0 1 0 5 Slab -On -Grade Edge Insulation FOYER 29It 0 244 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulation ELE tft 0 25 1`12 ---- 0 1 0 7 Raised Floor STAIRWAY ---- ---- 56 fF 19 0 0 1 8 Raised Floor KITCHEN ---- ---- 90 ft' 19 0 0 1 9Raised Floor KITCHEN ---- ---- 35 ft2 19 0 1 0 10Raised Floor LAUNDRY ---- ---- 72 fN 0 0 0 1 11Raised Floor LAUNDRY ---- --_- 10 ft2 19 0 1 0 12Raised Floor BEDROOM 4 ---- ---- 190 ft2 19 0 0 1 13Ralsed Floor ELEVATOR ---- ---- 25 ft2 19 0 0 1 14Raised Floor BATH 4 ---- ---- 60 ft2 19 0 0 1 15Raised Floor POWDER ---- ---- 8ft2 19 O 0 1 16Raised Floor POWDER ---- ---_ 55 it- 19 0 1 0 17Raised Floor A/C 2 ---- ---- 5 112 19 0 0 1 18Raised Floor MASTER BATH ---- ---- 28 ft2 19 0 1 0 19Ralsed Floor MASTER SUITE ---- ---- 4.5 W 19 0 1 0 20Ralsed Floor BEDROOM 3 ---- ---- 112 ft2 19 0 1 0 21Raised Floor BATH ---- ---- 40 iF 19 0 1 0 5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PedmeterR-Value Area JolstR-Value Tile Wood Carpet 22Raised Floor OFFICE ---- ---- 81 ft. 19 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2428 ft2 0 ft' Unfinishe N 0.5 No 0.7 No 22 30.3 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2096 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frec Truss Type 1 UnderAttic(Unvented) FLEX ROOM 0 Blown 101 ft' 0.1 Wood _ 2 UnderAttic(Unvented) LAUND. 0 Blown 25 ft- 0.1 Wood 3 UnderAttic(Unvented) GREAT ROOM 0 Blown 36 ft' 0.1 Wood 4 UnderAftic(Unvented) MASTER BATH 0 Blown 192 ft- 0.1 Wood 5 UnderAftic(Unvented) TOILET 0 Blown 24 ft- 0.1 Wood 6 UnderAttic(Unvented) MWIC 0 Blown 83 ft' 0.1 Wood 7 UnderAttic(Unvented) WIC 0 Blown 48 ft2 0.1 Wood 8 UnderAttic(Unvented) WIC 0 Blown 42 ft- 0.1 Wood 9 UnderAttic(Unvented) MASTER SUITE 0 Blown 515ft' 0.1 Wood 10 UnderAttic(Unvented) BEDROOM 0 Blown 195 ft2 0.1 Wood 11 UnderAttic(Unvented) HALLWAY 0 Blown 228W 0.1 Wood 12 UnderAttic(Unvented) STARIWAY. 0 Blown 104 its 0.1 Wood _ 13 UnderAttic(Unvented) BATH 0 Blown 50 ft' 0.1 Wood _ 14 UnderAttic(Unvented) WIC 0 Blown 50 R' 0.1 Wood 15 UnderAttic(Unvented) BEDROOM 0 Blown 168 ft' 0.1 Wood _ 16 UnderAftic(Unvented) BATH 3 0 Blown 50 IF 0.1 Wood 17 UnderAttic(Unvented) OFFICE 0 Blown 124 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block- PolystyrEbEX ROOM 11 18 0 9 0 162.0 ft- 0 0 0.3 0 2 E Exterior Concrete Block- PolystyrEbEX ROOM 11 30 0 9 0 270.0 ft- 0 0 0.3 0 _3 S Exterior Concrete Block- PolystyrEbEX ROOM 11 5 0 9 0 45.0 ft- 0 0 0.3 0 4 N Exterior Concrete Block- PolystyreriaAU ND. 11 10 0 9 0 90.0W 0 0 0.3 0 5 E Exterior Concrete Block- Polystyrenh4U ND. 11 1 0 9 0 9.0 ft. 0 0 0.3 0 6 W Exterior Concrete Block- Polystyrerla4U ND. 11 7 0 9 0 63.0 ff 0 0 0.3 0 7 W Exterior Concrete Block- Polystyrer®48ANA 11 10 0 9 0 90.0 ff 0 0 0.3 0 8 W Exterior Concrete Block- Polystyren(STAI R 11 11 0 9 0 99.0 ft' 0 0 0.3 0 5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 V FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Spate Cavity Width Height Sheathing Framing Solar Below _ 9 S Exterior Concrete Block-PolystyrenEOYER 11 8 0 9 0 72.0 ft' 0 0 0.3 0 10 W Exterior Concrete Block-PolystyrenEOYER 11 21 0 9 0 189.0 ft' 0 0 0.3 0 11 N Exterior Concrete Block-Polystyi@REAT ROO 11 21 0 12 0 252.0 ft- 0 0 0.3 0 12 NE Exterior Concrete Block-Polystyr@REAT ROO 11 9 11 12 0 119.0 ft' 0 0 0.3 0 13 E Exterior Concrete Block-PolystyGREAT ROO 11 14 0 12 0 168.0 ft' 0 0 0.3 0 14 W Exterior Concrete Block-PolystyGREAT ROO 11 21 0 12 0 252.0 ft' 0 0 0.3 0 15 W Exterior Concrete Block- PolystyrdhTAIRWAY 11 24 0 12 0 288.0 ft- 0 0 0.3 0 16 E Exterior Concrete Block -PolystyreKdTCHEN 11 14 0 12 0 168.0 ft' 0 0 0.3 0 17 E Exterior Concrete Block -PolystyrehAUN DRY 11 9 0 12 0 108.0 ft' 0 0 0.3 0 18 E Exterior Concrete Block- PolystyrBBDROOM 4 11 13 0 12 0 156.0T 0 0 0.3 0 19 S Exterior Concrete Block- PolystyRSDROOM4 11 14 0 12 0 168.0 ft' 0 0 0.3 0 20 S Exterior Concrete Block -PolystyrenBATH4 11 5 0 12 0 60.0 ft. 0 0 0.3 0 21 W Exterior Concrete Block-PolystyrenSATH 4 11 4 0 12 0 48.0 ft- 0 0 0.3 0 22 S Exterior Concrete Block- PolystyreNOWDER 11 9 0 12 0 108.0 ft' 0 0 0.3 0 23 W Exterior Concrete Block-PolystyreNOWDER 11 8 0 12 0 96.0 ft' 0 0 0.3 0 24 N Exterior Concrete Block -PolystyWASTER BA 11 14 0 9 0 126.0 ft' 0 0 0.3 0 25 E Exterior Concrete Block-PolystyrMASTER BA 11 6 0 9 0 54.0 ft' 0 0 0.3 0 26 W Exterior Concrete Block-PolystyrMMTER BA 11.. 16 0 9 0 144.0 ft' 0 0 0.3 0 27 W Exterior Concrete Block- PolystyrenEOILET 11 4 0 9 0 36.0 ft' 0 0 0.3 0 28 W Exterior Concrete Block-PolystyrenaM WIC 11 12 0 9 0 108.0 ft. 0 0 0.3 0 29 E Exterior Concrete Block -PolystyrendNlC2 11 6 0 9 0 54.0 ft' 0 0 0.3 0 30 N Exterior Concrete Block-PolystyfdMTER SUI 11 14 0 9 0 126.0ft' 0 0 0.3 0 31 E Exterior Concrete Block-Polystyf®ASTER SUI 11 20 0 9 0 180.0 ft' 0 0 0.3 0 32 E Exterior Concrete Block- PolystyRBDROOM 2 11 13 0 9 0 117.Oft- 0 0 0.3 0 33 W Exterior Concrete Block- PolystyreHALLWAY 11 7 0 10 0 70.0 ft' 0 0 0.3 0 34 W Exterior Concrete Block- PolystyrHTs4R IWAY. 11 13 0 9 0 117.0ft' 0 0 0.3 0 35 E Exterior Concrete Block-PolystyrenBATH 2 11 5 0 9 0 45.0 ft' 0 0 0.3 0 35 E Exterior Concrete Block-PolystyrendNlC 3 11 5 0 9 0 45.0 ft' 0 0 0.3 0 37 E Exterior Concrete Block- PolystyS6DROOM3 11 12 0 9 0 108.0 ft' 0 0 0.3 0 38 S Exterior Concrete Block-PolystyrB6DROOM 3 11 14 0 9 0 126.0 ft' 0 0 0.3 0 39 S Exterior Concrete Block- PolystyrenBATH3 11 5 0 9 0 45.0 ft' 0 0 0.3 0 40 W Exterior Concrete Block- PolystyrenBATH 3 11 3 0 9 0 27.0 ft- 0 0 0.3 0 41 S Exterior Concrete Block-PolystyrenSFFICE 11 9 0 9 0 81.0 ft- 0 0 0.3 0 42 W Exterior Concrete Block- PolystyrerOFFICE 11 12 0 9 0 108.0ft' 0 0 0.3 0 43 N Garage Frame -Wood OFFICE 11 10 9 90.0W 0 0.23 0.3 0 515/20207:26 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5of8 r FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown lstheentered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 N 1 Vinyl Low-EDouble Yes 1.06 0.39 Y 80.0 ft2 4 It 0 in 0 ft 0 in Drapes/blinds Exteriorl 2 E 2 Vinyl Low-EDouble Yes 0.79 0.28 Y 40.0 ft' 2 It 0 in 0 It 0 in None None _ 3 N 4 Vinyl Low-EDouble Yes 0.79 0.28 Y 24.0 IF 2ft Din 0ft0 in None None _ 4 S 9 Vinyl Low-EDouble Yes 0.79 0.28 Y 48.0 ft2 5 ft 0 in 3 it 0 in None None 5 W 10 Vinyl Low-E Double Yes 0.79 0.28 Y 40.0 ft' 2ft Din 25It0 in None None _ 6 N 11 Vinyl Low-E Double Yes 1.06 0.39 Y 112.0 ft- 8ft0in 0It0 in None None 7 NE 12 Vinyl Low-EDouble Yes 1.06 0.39 Y 62.0 ft2 10 It 0In 0 It 0 in None None 8 E 13 Vinyl Low-EDouble Yes 0.79 028 Y 56.0 ft' 2ft0in 13It0 in None None _ 9 W 14 Vinyl Low-EDouble Yes 0.79 0.28 Y 42.0 ft2 2 ft 0 in 13 It 0 in None None 10 W 15 Vinyl Low-EDouble Yes 0.79 0.28 Y 24.0 ft2 2 It 0 in 13 ft 0 in None None 11 E 16 Vinyl Low-EDouble Yes 0.79 0.28 Y 18.0 fF 2 It 0 in 13 ft 0 in None None 12 E 17 Vinyl Low-EDouble Yes 0.79 0.28 Y 14.0 ft2 2 ft 0 in 13 ft 0 in None None 13 E 18 Vinyl Low-EDouble Yes 0.79 0.28 Y 28.0 ft2 2 It 0 in 13 It 0 in None None 14 S 19 Vinyl Low-EDouble Yes 0.79 0.28 Y 40.0 ft2 5 It 0 in 2 It 0 in Drapes/blinds Exteriorl 15 S 19 Vinyl Low-EDouble Yes 0.79 0.28 Y 5.0 112 5 ft 0 in 13 it 0 in None None _ 16 S 19 Vinyl Low-EDouble Yes 0.79 0.28 Y 8.0 ft2 2ft 0In 14 It 0 in None None 17 S 20 Vinyl Low-EDouble Yes 0.79 0.28 Y 8.0 ft2 2ft 01n 14It0 in None None _ 18 W 23 Vinyl Low-EDouble Yes 0.79 0.28 Y 8.0 fF 2 It 0 in 13 It 0 in None None 19 N 24 Vinyl Low-E Double Yes 0.22 0.17 Y 18.0 ft2 2 It 0 in 1 It 5 in None None 20 N 24 Vinyl Low-EDouble Yes 0.22 0.17 Y 24.0 ft- 2 it 0 in 1 It 5 in None None 21 W 27 Vinyl Low-EDouble Yes 0.79 0.28 Y 10.0 ft2 2 ft 0 in 1 it 5 in None None 22 N 30 Vinyl Low-E Double Yes 1.06 0.3 Y 80.0 ft2 8 ft 8 in 1 It 5 in None None 23 E 31 Vinyl Low-E Double Yes 0.79 0.28 Y 20.0 ft2 2 it 0 in 1 ft 5 in None None _ 24 E 32 Vinyl Low-EDouble Yes 0.79 0.28 Y 20.0 ft2 2 It 0 in 1 ft 5 in None None 25 W 33 Vinyl Low-EDouble Yes 0.79 0.28 Y 20.0 ft2 2 ft 0 in 1 R 5 in None None 26 E 35 Vinyl Low-E Double Yes 0.79 0.28 Y 10.0 IF 2 ft 0 in 1 it 5 in None None _ 27 E 37 Vinyl Low-EDouble Yes 0.79 0.28 Y 20.0 ft2 2 it 0 in 1 ft 5 in None None _ 28 S 38 Vinyl Low-EDouble Yes 0.79 0.28 Y 40.0 ft2 5 It 0 in 1 R 5 in None None 29 S 38 Vinyl Low-E Double Yes 0.79 0.28 Y 10.0 112 2It0 in IIt5 in None None 30 S 39 Vinyl Low-E Double Yes 0.79 0.28 Y 10.0 ft2 2 R 0 in 1 R 5 in None None 31 S 41 Vinyl Low-E Double Yes 0.79 0.28 Y 40.0 112 5 It 0 in 1 ft 5 in None None GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 loft 9 ft 19 5/5/2020 7:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA Eq LA ACH ACH 50 1 Wholehouse ProposedACH(50) .000326 3606.3 197.98 372.33 .1933 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COPA 34 kBtu/hr COPA 27 kBlu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 16 34.2 kBtu/hr 1026 cfm 0.85 Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.85 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 80gal 60.9gal 120deg None SOLAR HOT WATER SYSTEM FSEC Cart # CompanyName Collector Storage System Model# CollectorModel# Area Volume FEF None None ft' DUCTS / V # --Supply--- Location R-Value Area ---Return--- Air CFM 25 OFM25 Location Area LeakageType Handler TOT OUT QN RLF HVAC# Heat Cool 1 2 Attic 6 325ft' Attic 6 275ft' Attic Attic 75 ft' DefaultLeakage Attic (Default) c(Default) c 95 ft' Defauldeakage Attic (Default) c(Default) c 1 1 2 2 TEMPERATURES Programabl[eT]hermostat::[ ]]Y [[ ]] Heating 4X] Jan [X] Feb [X] Mar Venting 1 Jan II 11 Feb [[XX]] Mar Ceiling Fans: 4f }1 [X] ] ] Apr [ ]May Jun [ ]Jul 4X] Aug 4X] Sep O t l[l 1 Jun I 1 Jul j 1 Aug I 1 Sep j[Xj] [X] Nov ec [[X]] Dec [ ] Dec 5/5120207:26 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 7of8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 56 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 ft' 0 ft 0.3 FLEX ROOM Default(Blbs/sq.ft. ft' It 0.3 LAUND. Default(Sibs/sq.ft. ft' ft 0.3 CABANA Default(Blbs/sq.ft. ft' It 0.3 STAIR DeMult(8lbs/sq.ft. ft' It 0.3 FOYER Default(8lbs/sq.ft. ft- It 0.3 ELE Default(81bs/sq.ft. ft. ft 0.3 GREAT ROOM Default(8lbs/sq.ft. ft' ft 0.3 STAIRWAY Default(Blbs/sq.ft. ft' It 0.3 KITCHEN Default(81bs/sq.ft. fl' It 0.3 LAUNDRY Default(8lbs/sq.ft.. fl' ft 0.3 BEDROOM 4 Default(8lbs/sq.ft. ft' It 0.3 ELEVATOR Default(8lbs/sq.ft. fN It 0.3 BATH 4 Default(8lbs/sq.ft. fl' It 0.3 POWDER Default(8lbs/sq.ft. ft' ft 0.3 A/C2 Default(8lbs/sq.ft. ft' It 0.3 MASTER BATH Default(Blbs/sq.ft. ft' ft 0.3 TOILET Default(Slbs/sq.ft. ft' ft 0.3 M WIC Default(81bs/sq.ft. ft' It 0.3 WIC Default(Blbs/sq.ft. ft' It 0.3 WIC Default(Slbs/sq.ft. ft' ft 0.3 .. MASTER SUITE Default(Blbs/sq.ft. ft' It 0.3 BEDROOM 2 Default(81ba(sq.ft. ft' It 0.3 HALLWAY Default(8lbs/sq.ft. ft' it 0.3 STARIWAY. Default(8lbs/sq.ft. ft' It 0.3 BATH 2 Default(81bs/sq.ft. ft- It 0.3 WIC Default(8lbs/sq.ft. ft' ft 0.3 BEDROOM 3 Default(8lbs/sq.ft. ft' It 0.3 BATH 3 Default(8lbs/sq.ft. ft' It 0.3 OFFICE 515120207:26 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 8of8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LOT #37 WATERSONG Builder Name: Street: 4824 WATERSONG WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: _ Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceilingiattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation In an dropped ceiling/soffit Y 9 /soffit the Insulation and any gaps in the air barrierair shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the topside floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by Insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures Installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be out neatly to fit around wiring and plumbing In exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/5/2020 7:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 80.7 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 4223 d) Room unitIPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.858 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.305 14. Heating system: Capacity 61.0 c) Area 7c. 979.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 88. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. varies 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 11.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the lorida Building Code, Energy Conservation, through the above energy saving features which will be instal (or ex eeded) in this home before final inspection. Otherwise, a new EPL display card will be completed n in alled code compliant features. Builder Signature: Date: 7 0 Address of New Home: 4824 WATERSONG WAY City/FL Zip: ST. LUCIE COUNTY, FL 5/5/20207:26:59 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1