HomeMy WebLinkAboutGenerac, project information16/20/22 kW INCLUDES: • True Power T" Electrical Technology • Two Line LCD Multilingual Digital Evolution" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* FEATURES GENERAL GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz IIR , O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G -Force engine lineup offers added peace of mind and reliability for when you need it the most. The G -Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. GENERAL -- U CLIS EDUS QU'E­T__T-E__15T- Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA MGI -22 EVALUATION confidence is that the GENERAL product line includes its own transfer v SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. LL' GENERAL ryA736m LL� ALF I— PROMISE Lsr°Meas �gAFAN 16/20/22 kW Model # G006463-4 G005819-0 G007101-0 G007102-0 G007103-0 G005621-0 G007027-0 - Bisque GENERAC available accessories Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac - Mobile Link" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). Battery Pad Warmer The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below O'F. Breather Warmer Auxiliary Transfer Switch Contact Kit Fascia Base Wrap Kit (Standard on 22 kW) 6005703-0 - Bisque Paint Kit I G006485-0 i Scheduled Maintenance Kit G006873-0 Smart Management Module i (50 Amps) 727.2— [28.6 2mm[28.6 In] The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. - - - 637.6 — -- ---- 125.1 1�1 [26.6 InJ LEFT SIDE VIEW GENERAC° 1248 mm 148.0In, [48.8 88 FRONT VIEW Model UPC G007035-0 696471070354 0007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 Generac Power Systems, Inc. • 645 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2016 Generac Power Systems, Inc. All nghts reserved. All specifications are subject to charge without notice. Part No. 10000000194-D 10/24/16 GENERAC4 16/20/22 kW switch options Limited Circuits Switch Features • 16 circuits, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions H1 Height H2 W1 Width W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 1 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 Model G007036-0 (16kW) No, of Poles 2 Currenl Rating (Amps) 100 Voltage Rating (VAC), 120/240,10 - g Utility Voltage Monitor (Fixed)* No. of Poles -Pick-up 80% -Dropout 65% Return to Utility' approx, 15 sec Exereses bi-weekly for 5 minutes`t standard UL Listed Standard Total Circuits Available 16 Tandem Breaker Capabilities 8 spaces Circuit Breaker Protected -Pick-up -Dropout Available RMS Symmetrical 10,000 Fault Current (_u)250 Volts Return to utility{ *Function of Evolution Controller • Exercise can be set to weekly or monthly Exercises bi-weekly for 5 minutes' DEPTH Service Rated Smart Switch Features Model G007037-0 (16 kW)/G007039-0 (20 kW)/ • Includes Digital Power Management Technology standard (DPM). 6007043-0 (22 kw) No. of Poles 2 • Intelligently manages up to four air conditioner loads with no additional current Rating (Amps) 200 hardware. Voltage Rating (VAC) 120/240,10 • Up to four more large (240 VAC) loads can be managed when used in Utility Voltage Monitor (Fixed)- conjunction with Smart Management Modules (SMMs). -Pick-up -Dropout 80% 6595 • Electrically operated, mechanically -held contacts for fast, clean connections. Return to utility{ approx. 13 sec • Rated for all classes of load, 100% equipment rated, both inductive and resis- Exercises bi-weekly for 5 minutes' standard tive, UL Listed Standard • 2 pole, 250 VAC contactors. Enclosure Type NEMA/UL Sri • Service equipment rated, dual coil design. Circuit Breaker Protected 22,000 • Rated for both aluminum and copper conductors. Lug Range 250 MCM - #6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution Controller • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mount- Exercise can be set to weekly or monthly ing flexibility. Dimensions 200 Amps 120/240, 1e Open Transition Service Rated H1 H2 W1 Height Width W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 16/20/22 kW GENERAL' _ specifications C vlz:xr of 3r' 07043 0 Model Rated Maximum Continuous Power Capacity (LP) Rated Maximum Continuous Power Capacity (NG) Rated Voltage Rated Maximum Continuous Load Current — 240 Volts (LP/NG) Total Harmonic Distortion Main Line Circuit Breaker Phase Number of Rotor Poles Rated AC Frequency Power Factor Battery Requirement (not included) Unit Weight (Ib/kg) Dimensions (L x W x H) in Sound output in dB(A) at 23 It (7 m) with generator operating at normal load' Sound output in dB(A) at 23 it (7 m) with generator in Quiet -Test" low -speed exercise mode`" G007035-0, G007036-0, G007038-0, G007039-0 G007042-0, GO 309 (8.75) 301 (8.52) 310 (8.78) G007037-0 (16 kW) (20 kW) (22 kW) 106.8 (2.94) [11.11) 129.6 (3.56) [13.48] 140 (3.87) [14.65] 16,000 Watts' 20,000 Watts' 22.000 2 16,000 Watts* 18,000 Watts' 19,500 999 cc 240 240 240 Off 66.6/66.6 83.3/75 91.6/81.3 Overhead Valve Less than 5% Less than 5% Less than 5% , 70 Amp 100 Amp 100 Amp Electronic 1 1 1 2 2 2 60 Hz 60 Hz 60Hz 1.0 1.0 1.0 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 GCA Minimum 406/186 448/203 466/211 Automatic Low Oil Pressure/High Oil Temperature Shutdown 48 x 25 x 29/1218 x 638 x 732 Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown 66 66 67 58 58 58 5 min 5 min 5 min Engine 218 (6.17) 204 (5.78) 216 (6.12) Full Load 309 (8.75) 301 (8.52) 310 (8.78) Liquid Propane fta/hr (gal/hr) [Vhrj 1/2 Load 91.6 (2.52) [9.53) 86 (2.37) [8.99] 93.2 (2.56) [9.70) GENERAL G Force 1000 Series 106.8 (2.94) [11.11) 129.6 (3.56) [13.48] 140 (3.87) [14.65] Type of Engine inlet at all load ranges - 3.5-7" water column (7-13 mm mercu(y) for natural gas, 10-12'' water column (19-22 mm mercury) 2 2 Number of Cylinders 2 999 cc 999 cc 999 cc CAutomatic Start on Utility failure. '7'day exerciser. Manual Aluminum w/ Cast Iron Sleeve Off Cylinder Blocsplacement Cylinder Block Overhead Valve Overhead Valve Overhead Valve Valve Arrangement Solid-state w/ Magneto Solid-state w! Magneto Solid-state w/ Magneto Ignition System Electronic Electronic Electronic Governor System 9.5:1 9.5:1 9.5:1 Compression Ratio 12 Vdc 12 Vdc 12 Vdc Starter Oil Capacity Including Filter Approx. 1.9 1 L Approx. 1.9 gV1.8 L Approx. 1.9 gV1.8 L Operating rpm 3,600 3,600 3.600 Fuel Consumption Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Natural Gas ION (ma/hr) 1/2 Load 218 (6.17) 204 (5.78) 216 (6.12) Full Load 309 (8.75) 301 (8.52) 310 (8.78) Liquid Propane fta/hr (gal/hr) [Vhrj 1/2 Load 91.6 (2.52) [9.53) 86 (2.37) [8.99] 93.2 (2.56) [9.70) Full Load 106.8 (2.94) [11.11) 129.6 (3.56) [13.48] 140 (3.87) [14.65] Note, Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercu(y) for natural gas, 10-12'' water column (19-22 mm mercury) for LP gas. For Btu content, multiply fta/hr x 2500 (LP) or I0/hr x 1000 (NG). For Megajoule content, multiply ri x 93.15 (LP) or m3/hr x 37.26 (NG) Controls 2 -Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons:Auto CAutomatic Start on Utility failure. '7'day exerciser. Manual Start with starter control, unit stays on. 11 utility falls, transfer to load takes place. Off :;. Stops unit. Power is removed. Control and charger still operate. a Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) rom 140-171 V119O-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard _ RuNAlarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking, 16 sec on, 7 rest (90 sec maximum duration). Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration BS5514, IS03046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with level; also will decrease about 1 percent for each 6'C (10 °F) above 16'C (60 °F). content. ambient temperature. altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feel (304.8 meters) above sea and 16/20/22 kW Model # G006463-4 G005819-0 G007101-0 G007102-0 G007103-0 G005621-0 G007027-0 - Bisque GENERAC available accessories Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac - Mobile Link" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). Battery Pad Warmer The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below O'F. Breather Warmer Auxiliary Transfer Switch Contact Kit Fascia Base Wrap Kit (Standard on 22 kW) 6005703-0 - Bisque Paint Kit I G006485-0 i Scheduled Maintenance Kit G006873-0 Smart Management Module i (50 Amps) 727.2— [28.6 2mm[28.6 In] The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. - - - 637.6 — -- ---- 125.1 1�1 [26.6 InJ LEFT SIDE VIEW GENERAC° 1248 mm 148.0In, [48.8 88 FRONT VIEW Model UPC G007035-0 696471070354 0007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 Generac Power Systems, Inc. • 645 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2016 Generac Power Systems, Inc. All nghts reserved. All specifications are subject to charge without notice. Part No. 10000000194-D 10/24/16 installation System • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. GENERACm 16/20/22 kW features and benefits Engine • Generac G -Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time, • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval, • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25°% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution*" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer, • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner, • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. installation System • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.