Loading...
HomeMy WebLinkAboutProduct approvalsME e e BCIS Home I Log In I User Registration I Hot Topics I submit Surcharge I Stats & Facts I Publications I Conrad Us I eCis site Map I links (Search Floridpr Product Approval gg USER: Public User sil,yt n t Product Agioreval Menu > Product or A011cazlon Search > ARRllcation List > Application Detail FL # FL16107-RII Application Type Revision Code Version 2017 Application Status Approved Comments Evaluation Report Archived Florida License Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. 12/31/2020 Mason, OH 45040 Gary Pfuehler (513)770-6062 Validation Checklist - Hardcopy Received mwesterfield@clopay.com Authorized Signature Scott Hamilton shamliton@clopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Emall Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ..a Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Hamilton Evaluation Report ANSI/DASMA 108 Florida License PE -63286 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By Gary Pfuehler 2002 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards FL16107 R11 COI Certification of Independence of Validation Entity_ jy Pfuehler.Zd( FL16107 R11 COI Statement on Independence of Evaluation Entity_ ScottHamilton 120424.pd Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Certified By Florida Licensed Professional Engineer or Architect FL16107 R11 Equiv 20170809 - FBC - DASMA 108 equiv.pdf FL16107 R11 Equiv 20170809 - FBC - DASMA 115 eauly d Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/10/2020 Date Validated 04/10/2020 Date Pending FBC Approval 04/13/2020 Date Approved 06/02/2020 Summary of Products Go to Page I® 0 0 Page 2/ 3 FL # Model, Number or Name Description 16107.21 21 WB -16 DSIE-1F471: GD2SP, Double -skin Insulated EPS (exterior skin 27 ga. min.; interior GR2SP, GD2LP, GR2LP, AR2SP, skin 27 ga. min.) Double -Car (97" to 16'2" wide) WINDCODE® AR2LP, ED2SP, ED2LP, 4302, HDGC, W8 Garage Door with Optional Impact -Resistant Lites 6202, MFC68, 4305, HDGR, 6205, SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 R11 II 104786-RevO4-signed.pff Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +46 PSF/-52 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R11 AE CBPC 130214-A pd doors with optional Impact -resistant glazing are Impact- Created by Independent Third Party: No resistant (large missile impact), 16107.22 22 W6-09 DSIE-1F171: 4400, 4401, Double -skin Insulated EPS (exterior skin 27 ga. min.; Interior 4301, 4300, 4301, 4310, HDG, skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE© W6 HDGL, HDGF, 66, 66G, 67, 67G, 68, Garage Door with Optional Impact -Resistant Lites SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 R11 II 101526-A-Rev20 slg0ed.p,Lif Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R11 AE CBPC 130214-A.p,df doors with optional Impact -resistant glazing are Impact- Created by Independent Third Party: No resistant (large missile impact). 16107.23 23 W6-09 DSIE-IF171: 4400, 4401, Double -skin Insulated EPS (exterior skin 27 ga. min.; interior 4300, 4301, 4310, HOG, HDGL, skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE@ W6 HDGF, 66, 66G, 67, 67G, 68, SP200, Garage Door SF200, SE200, 6200, 6201, 6203 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R11 II 101526-B-Rev20 sig0_ed pff Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 jrnpaet-Reslstant:-No----� Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PS Evaluation Reports Other: Doors with standard glazing meet the w Igad FL16107 Rll AE CBPC 130214-A.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.24 24 W6-09 PAN -2F153: 84A, 94, 73, St el Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 75, 1500, 190, 4RST, 4RSF, 4F, W NDCODE® W6 Garage Door with Optional Impact -Resistant 6RST, 6RSF, 48, 42, 55, 48B, 42B, tes 555, GOSS, GDSSV, GRSS, GRSSV, AR5$, ARSSV, EDSS, EDSSV Limits ofUse Installation Instructions _.Approved for Ose4n IHVffZLYa FL16107 R11 II 101348-A-Revl7-signed gdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 RSI AE CBPC 130214-A.pdf Created by Independent Third Party: No doors with optional Impact-resistant glazing are impact- resistant (large missile impact). 16107.25 25 W6-09 PAN-21`153: 84A, 94, 73, Steel Pan (min. 25 ga.) Single-Car (up to 9'0" wide) 75, 1500, 190, 4RST, 4RSF, 4F, WINDCODEO W6 Garage Door 6RST, 6RSF, 48, 42, 55, 488, 428, 555, GOSS, GDSSV, GRSS, GRSSV, AR55, ARSSV, EDSS, EDSSV Limits of Use Installation Instructions Approved for use in HVHZ: No EL16107 R11 II 101348-B-Rev17-signnd pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 1111 AE CBPC 130214-A.pdf requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.26 26 W6-09 PAN-21F156: 76, 76V, 2RST Steel Pan (min. 25 ga.) Single-Car (up to 9'0" wide) WINDCODE0 W6 Garage Door Limits of Use installation Instructions Approved for use in HVHZ: Yes FL16107 RI1 II 101348-A-Revl7-signnd Rd Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 RSS AE CBPC 130214-A pdf doors with optional Impact-resistant glazing are impact- Created by Independent Third Party: No resistant (large missile Impact), 16107.27 27 W6-09 PAN-21`156: 76, 76V, 2RST Steel Pan (min. 25 ga.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 111 II 101348-B-Re 17-signed.pd Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 RSl AE CBPC 130214-A.pd requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.28 28 W6-09 DSIE-IA171: 2050, 2051, Double-skin Insulated EPS(exterior skin 27 ga, min.; Interior 2053, 4050, 4051, 4053, 62, 64, 65, skin 29 ga. min.) Single-Car (up to 9'0" wide) WINDCODEO W6 62G, 62LG, 64G, SDP38, SFL38, Garage Door SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 1111 II 104814-A-Rev00-signed.odf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +36 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are FL16107 R11 AE CBPC 130423-A.pdf Impact-resistant (large missile Impact). I Created by Independent Third Party: No 16107.29 29 W6-09 DSIE-1A171: 2050, 2051, Double-skin Insulated EPS(exterlor skin 27 ga. min.; interior 2053, 4050, 4051, 4053, 62, 64, 65, skin 29 ga. min.) Single-Car (up to 9'0" wide) WINDCODEO W6 62G, 62LG, 64G, SDP38, SFL38, Garage Door SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Installation Instructions Approved for use In HVHZ: No FL16107 R13 II 104814-B-Rev00-signed pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +36 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R11 AE CBPC 130423-A.pdf requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.30 30 W6-09 DSIE-11`471: GD2SP, Double-skin Insulated EPS (exterior skin 27 ga. min.; Interior GR2SP, GD2LP, GR2LP, AR2SP, skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE@ W6 AR2LP, ED2SP, ED2LP, 4302, HDGC, Garage Door with Optional Impact-Resistant Lites 6202, MFC68, 4305, HDGR, 6205, SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 RII II 103954-A-Rev05-signedpdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 RSI AE CBPC 130423-A pdf Created by Independent Third Party: No _ w o 111i1,rnIn v, �pNd aNOQG �r `.``pjy^�O ^z a; O�� v 000ua r R n Eq z m m: _ > P'noll•II �r :O O\/moi yii:'� o n n�t$,A -1 :•a � h � �mN o '_n opo P f n 2p. •N➢ W0. N � c N U r �...W H 9 � u PF ice. L1� ' 3 u I Nm n rAi n '1o�n f.lA T O � o N OY DL) I �T .'-@amu d Li x5>5, 1/i VIN k31'AOOZ — MAX; DOOR HEIGHT Q HEIGHT FOUR SECTION DOOR _JOV'T x � � rp \W riY"IOaN o \gym N 1� N " xa nl A VAI1N C OUT 9y SII FrN I LN I O 11A 00 1 ZO YJ \l O '> VI VI� V41�yi �� 11 LZ1 I T O<l 'A prpll ] WZ } Om n S,m;I' pN I m T ly, I S Y � 2 1 Ymll A 22 rDO♦'j'n V 00 _ ?Y Op.� p ✓� N OjI u10 ��✓� AZ9�Vm1 Umm O,V a� �N ;TU olio a:.n N9 `'`im nOJ 9 111111 ilk N OmN W �UC h�y z " \8N^ Su j o mono "vm <� " N ..: KbFE �gnoo voo S!oy;"� i� I O F a o V!/ N_o 1• /��y IIIC 2 ^T8IIm6 VOOr n W�O v:_ h Op co ON Z T 11 W p10.1%ND:V \I ii > v u C) o :.A i r w LD CI IMIN J� 0t,d �. ?oz zz mvm Z;Q yy,J o nor\�w D:y -r ;Q ` h ........... ,err E.... ... * . :.A i r w LD CI IMIN V N 0 v i^ n R n I N � I u In pad._- n V>n �;; .......... s�o C641 N 2 2 xti ' Z,)Jv m•x Dtm 10 U y� " IIx/t/ ..C,` A T02 L(l I� OrnWA A ONdA Nn x O xgFFq l �. ItTt. Rg..� �INu mNiaoC. NK' N� N u 2�ZO Zm JAN 7 I V�FAP' �iop r noo'9 (�1 oomv�in mid ' oN OWA(1 - 0P ovvxl r N'o �n TO O N OqC 9o�1 t/1 5o roa0 i 00,.. g A d FF u2 c A Z LO I. o Am - 2N-1 7 ^ y o4G O nn O Z N 4C 41 � ' t0 N N K V +vml�Ns Noiom= 6yozrz N I• Z Nn O➢pAZf T m0Ni ':IT➢ m0'tia2 S co N O - OmOmmn 1 mux VI\�A� 1 UAANf x � Y C ",y p� •04 �jjOnZG O 'V VSO 4Zi rrml AV'O�I mn ♦410 i ��� m�"moI T Pm O Y= 1 Dll N i T �i I n U1133 N 0 v i^ n R n I N � I n V>n )yK i C641 N 2 2 xti Z,)Jv +vml�Ns Noiom= 6yozrz N I• Z Nn O➢pAZf T m0Ni ':IT➢ m0'tia2 S co N O - OmOmmn 1 mux VI\�A� 1 UAANf x � Y C ",y p� •04 �jjOnZG O 'V VSO 4Zi rrml AV'O�I mn ♦410 i ��� m�"moI T Pm O Y= 1 Dll N i T �i I n U1133 � ° 1 ® UD 0 - »`; \ \ \![ ; - 9 -- ( \j\ \« { °`!9« © _,_.DOOR _— ,. . — —w—. � � §y: \ d m ° 1 ® UD 0 99i \ \ \![ ; - > ( \j\ \« { © _,_.DOOR _— ,. . — —w—. � 99i \ \ \![ ; - > ( \j\ \« { © :n! ( - \\\\}\ \ \« { © { ( \ §/ §! \ \ / February 14, 2013 (Revised 8/10/17) Evaluation Report for Clopay Building Products Company Sectional Garage Doors, W6 through WS I have evaluated the wind load door designs as shown on the drawings listed below. I have reviewed the test reports, which were generated by accredited independent laboratories as required by the relevant Florida Administrative Rule, the engineering rational analysis, and the product drawings, The test reports are listed below. Assembly testing was conducted by American Test Lab North Carolina. Component testing was conducted by HETI and ETC. For the doors listed in Tables 1 through 5, Static Pressure Tests were conducted in accordance with TAS 202-1994, ASTM -E330-2002 and ANSI/DASMA 108-2005. Missile Impact and Cyclic Pressure Tests were conducted in accordance with TAS 201-1994 and TAS 203-1994 and ASTM E1886-2005 and ASTM E1996-2009 and ANSI/DASMA 115-2005, The pressures listed on the drawings are either direct results of these tests or results obtained through engineering rational analysis based on actual tests. I have concluded that the door designs listed below in Tables 1 through 5 are in compliance with these High Velocity Hurricane Zone test requirements of the Florida Building Code and therefore are qualified as impact -resistant assemblies (large missile Impact). TABLE 1: Drawlnos for doors with Manufacturing Product Code (MPC) PAN -M5.3;_ 101348-A-aev17, max. door size 9'0"" x 16'0"; +38/-44 PSF (design load) TABLE 2' Drawings for doorrtlLM.al>> c_ ring Product Code (MPC) PAN -2F156; 101348-A-Rev17, max. door- size 9'0"" x 16'0"; +38/-44 PSF (design load) TABLE 3' Drawings for doors with Manufacturing Product Code (MPC) DS )-_ 171: 101526-A-Rev20, max, door size 910"" x 16'0"; +38/-44 PSF (design load) TABLE 4: Drawing-s-foY-d-oor5. witlI ManufactuJM Product Code (MPC) DSIU-1F171: 104778-RevO3, max. door size 16'2" x 16'0"; +46/-52 PSF (design load) 104785-A-Rev03, max. door size 16'2" x 16'0"; +38/-4Z PSF (design 104786-RevO4, max. door size 16'2" x 16'0"; +46/-52 PSF (design 1 For the doors in Tables 6 through 9, Static Pressure Tests were conducted In accordance with ASTM -E330-2002 and ANSI/DASMA 108-2005. The pressures listed on the drawings are either direct results of these tests or results obtained through engineering rational analysis based on actual tests, I have concluded that the door designs listed below in Tables 6 through 9 are in compliance with these test requirements of the Florida Building Code, TABLE_ �r„prawil)ys for doors with Manufacturingdl��t ode (MPC) PAN -2F153 101348-e--Rev17, max. oar size 9'0'ir x 16 0”; +38/-44 PSF (design load) PACE 1 of 3 FILE: CBPC_130214-A.3 EVALUATION REPORT FOR CLOPAY BUILDING PRODUCTS COMPANY SECTIONAL GARAGE DOORS, W6 ^ WB TABLE 7' Drawinas for doors with Manufacturing Product Code (MJ'.) PAN -2f 156: 101348-3-Rev17, max, door size 9'0"" x 16'0"; -P38/-44 PSF (design load) TABLES: Drawings for doors with Manufacturing Product Code (MPC) DSIE-11`171.: 101526-B-Rev20, max. door size 9'0"" x 16'0"; +38/-44 PSF (design load) TABU DgWinas for doors with Manufacturing ProdticKode (MPCU DSIE-11`471: 104785-B-Rev03, Max. door size 16'2" x 16'0"; -P38/-42 PSF (design load) Test Reports: ATL -0107,01-13 (2/20/13), ATL -1206,01-12 (1/23/13), ATL -0801,01-12 (8/15/12), ATL -0827,01-12 (10/9/12), ATL -0115,01-13R (3/18/13), ATL -0117,01-13R (3/18/13). These reports document compliance with the TAS testing standards and are signed and sealed by David Johnson, FL PE 61915. Product Description for doors with MPC PAN -2F153: These doors consist of 2" thick steel pan sections with min. 25 ga. (0.019") skins, The steel skin is at least G40 DDS per ASTM A653, The maximum section height Is 21". These doors may have optional Impact -Resistant Glazing (Molded). Optional Impact -Resistant Glazing is a one-piece injection -molded front frame and glazing, The following models are at least structurally equivalent to the tested door: 84A, 94, 98, 73, 75, 1500, 190, 4RST, 4F, 4RSF, 6RST, 6RSF, 48, 48B, 42, 42B, 55, 55S, GD5S, GDSSV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV, Not all models may be shown on a given drawing. Product Description for doors with MPC PAN -2F156: These doors consist of 2" thick steel pan sections with min, 25 ga. (0,019") skins. The steel skin is at least G40 DDS per ASTM A653, Sections may have 1-5/16" insulation captured in the cavity of the pan section. The maximum section height is 21". These doors may have optional Impact -Resistant Glazing (Molded). Optional Impact -Resistant Glazing is a one-piece Injection -molded front frame and glazing, The following models are at least structurally equivalent to the tested door; 76, 76V, 2RST. Not all models may be shown on a given drawing. Product Description for doors with MPC DSIE-11`171: These doors consist of 2" double -skin Insulated sections with an EPS core laminated to both skins. Both Inner and outer skins are min. 27 ga. (0,016") G40 DDS per ASTM A653. The maximum section height is 21". These doors may have optional Impact -Resistant Glazing (Molded). Optional Impact -Resistant Glazing is a one-piece Injection -molded front frame and glazing, The following models are at least structurally equivalent to the tested door; 4300, 4301, 4310, HDG, FIDGL, FIDGF, 66, 66G, 67, 67G, 68, 6200, 6201, 6203, SP200, SF200, SE200, Not all models may be shown on a given drawing. Product Description for doors with MPC DSIU-11`171; These doors consist of 2" double -skin insulated sections with polyurethane insulation foamed in place between both skins. Both inner and outer- skins are min. 27 ga. (0.016") G40 DDS per ASTM A653. The maximum section height Is 21". These doors may have optional Impact -Resistant Glazing (Molded). Optional Impact -Resistant Glazing Is a one-piece Injection -molded front frame and glazing. The following models are at least structurally equivalent to the tested door: HDP20, HDPF20, I-IDPL20, 7200, PAGF. 2 or 3 FILE: CBPC_130214-A•3 EVALUATION REPORT FOR CLOPAY BUILDING PRODUCTS COMPANY SKMONAL GARAGE DOORS, W6 - W8 7201, 7203, 8200, 8201, 8203, 9200, 9201, 9203. Not all models may be shown on a given drawing. Product Description for doors w t"P_C D?)Er,E47-J,_;, These doors consist of 2" double -skin insulated sections with an EPS core laminated to both skins. Both Inner and outer skins are min. 27 ga. (0.016") G40 DDS per ASTM A653, The maximum section height is 24". These doors may have optional Impact -Resistant Glazing (Aluminum), Optional Impact -Resistant Glazing is an aluminum front frame and a separate polycarbonate glazing, The following models are at least structurally equivalent to the tested door: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, MFC68, 4305, HDGR, MFR68, 6205, SFR68, Not all models may be shown on a given drawing, ijpa,c Resistant GlazingLMolded)_ The optional impact resistant glazing Is an Injection -molded polycarbonate front frame and glazing (GE LEXAN SLX2432T) that is an approved C1 plastic in accordance with testing required by FBC-B 2612, Approval based on review of the following tests: HETI-06-AO02 ASTM G155; HETI-06-T566 ASTM D638 (before); HETI-06-T634 ASTM D638 (after); ETC -06-1024-17496,0 ASTM D2843, ASTM D635, ASTM D1929. Impact Resistant Glazing (Aluminum): The optional Impact resistant glazing Is an aluminum front frame and a separate polycarbonate glazing that is an approved C1 plastic In accordance with testing required by FBC-B 2612. Approved polycarbonate materials are Sabic IP Lexan 9034 (versions also approved: MR10, 9030, 90318, 90316, 9031.7, 90311, 90314, 90355) and Bayer Makrolon GP (versions also approved: SL, AR, 15). Approval based on review of NOA 13-0717,01 (Sabic IP, exp. 7/17/18) and NOA 12-0605,05 (Bayer, exp. 8/27/17). Limitations: The drawing(s) cited above are an explicit part of this evaluation report. The text of this report does not attempt to address all design details and relies on the illustrations and text of these drawings as well Jambs, lintels, sills or other structural elements required to prepare openings are not covered. The design of the supporting structural elements shall be the responsibility of the professional of record for the building or structure and in accordance with current building codes for the loads listed on the drawing(s) referenced above. Installation requirements per the relevant Florida Administrative Rule, including attachments, are detailed on the drawing(s) listed above, Installation must be in accordance with manufacturer's installation instructions and must be as shown on the drawing(s) listed above. The manufacturer's licensed design professional listed on the drawing(s) has reviewed the attachment details and installation requirements, Signature: Scott Hamilton, P. E. Florida P. E. No. 63286 Date: 80!/e PAGE 3 OF 3 Fae: CBPC,,,130214-A.3