Loading...
HomeMy WebLinkAboutProduct Approval (2) WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING 15211 97th Road N FILE est Palm Beach,FL 33412 /F t 225-1982 PRODUCT EVALUATION - (FOR HVHZ APPROVED PRODUCT) REVIEWED FOR PRODUCT: DM CLASS 500 26 GA. GALVALUMP5 C M 4 " �L��I�C E ROOF PANEL (FLPA#27499.17) IE ®UNTY MANUFACTURER: DYNAMIC METALS, LLC KE=0 =14 340 PIKE ROAD WEST PALM BEACH, FL 3341 JUN 1,'8 ,120 To all concerned, ST. Lucie County, Permitting The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24"Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02- 450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "5VS-HZ"dated 8115119, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE, 3. Supplemental Calculations to support"5VS-HZ"drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 24" (nominal) Fastener Spacing across panel: 12" (at Overlaps&Center Rib) Min. Slope: HVHZ: 2'712" Non-HVHZ: '/2'712"(with Lap Sealant) 3"112" (no Lap Sealant) 5FFCIALIZIN6 IN IMPACT IZ�515fMf CUFMINW&L5, 51"OC FPOW5, & WIN12OW5 Field Perimeter&Corner Installation Installation Max. Design Pressure: -117.75 psf -206 psf Fastener Spacing: 4" From Ends, 16" Max. O.C. 4" From Ends, 8" Max. O.C. Min Panel Fasteners: #10x1 %"HiLo HWH Screw #10x1 '/"HiLo HWH Screw with Weather-seal Washer with Weather-seal Washer Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ, 1"round plastic caps may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II with 4"overlaps and 6"end-laps, anchored with 12 Ga. x 1 '/"galvanized roof nails with 32 Ga.Tin caps spaced 6" O.C. in rows at the perimeter, at overlaps, and two intermediate rows staggered and spaced 12" O.C. (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ, 1"round plastic caps may be used to prevent galvanic reactions. Minimum Substrate: %' (15132"min)4-ply CDX Plywood, nailed to 2x rafters spaced 24"max. O.C.with 8d ring-shank nails spaced 4"O.C. Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 4. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 5. All panels shall be permanently labeled with the manfacturer's name and/or logo, and the following statement, "Dynamic Metals FL#27499.17, DM Class 500". SPECIALIZING IN IMPACT p1�515W CUPfAINWA15,5f0FVF0Nr5, & WINPOW5 Panel Forming: These panel maybe job .. 5 .- -roll formed with the following Dynamic'Metals,machinos per site approval of 3rd party QA.provider,toF the dimenslons,shfth:on Drawing 5V$-HZ,:. S M SQ'6 800617 S'SQ-$1,5021 6 M768-10617 S$Q-6696617 S804660-615 S-SQ-8681 I 1B VC-049671 8 5VC-0360516 5VC-0521218. Re-Roofing: The bWGIassl 500 Series 26;6a,..Oalv'afume V Crimp 24°Wide Roof Panel maybe installed,overs single!l y5r o Oisting.asphaItshitl es, pro ido;the existing too meets the requirements of Section.1521 (HVHZ)wlSectlion'15,11 (outside of rHVHZ),Of'the Florida Building Code. If you have any qpesti ns:or need more information.concerning this approvaliplease contact mo,. Thank you, OZ35-4 *ct�Wo*ers, FL PE# 62354 STATE O F AUG 16 2019, on N :0 NA L 5r1T,CIfN,IZNCA IN V Wcr i "515-rmr CUrfAJRvVALL-5,.51,m wwf 52; h• ;1 q . OWMA Baa WON 9,"O'E' ", a P 1 q An � ec�eal"Nast��rs . CeCY�I Ite�?QfC s x>G✓ '3 .,' r77 15f@ eC 3 ' '-24",h'ta�dmt€m'{Ve{�oyetage {a"'s a� i Patfe[P..ioflle: �'�ff1