HomeMy WebLinkAboutSunlast Metal - 26ga Nail Strip� unlast Metal Value Engineered Metal Roofing ™
FLORIDA PRODUCT APPROVAL
ECONO LINE ( CLIPLESS NAIL STRIP/SNAP LOCK )
26 GA -16"COVERAGE WIDTH ROOF PANEL OVER 15/32" PLYWOOD
FLORIDA PRODUCT APPROVAL NO 21383.1...._ ________________ ��-----------------SER IE S
Product Evaluation Report
1" CL/PLESS NAIL STRIP 26GA Roof Panel over 15/32" Plywood
Florida Product Approval # 21383.1
Florida Building Code 2014 Per Rule 61620-3
Method: 1-0
Category: Roofing Subcategory: Metal Roofing Compliance Method:
Rule 61G20-3
NON-HVHZ
Product Manufacturer:
Sunlast Metal
2120 SW Poma Drive Palm City, Florida 34990
Engineer Evaluator
James Biagi, P.E. FL# 37467
1915 NE 45th ST. #107
Fort Lauderdale, FL 33308
954-776-8004
Validator:
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Evaluation Report 1-4
Page 1 of 4
Page 2 of 4
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2, 1507.4.3,
Product Description: 26GA Nail Strip/Snap Lock Metal Panel, 16" Coverage Width, Roof panels, 1.0” Rib height
Panel restrained with #10 x 1” Pancake Head fasteners into 15/32” 4 ply CDX Plywood decking.
Non‐structural Application.
FOR USE IN NON‐HVHZ.
Material: 26GA metal conforming to Florida Building Code 2014 Section 1507.4.3 Yield Strength: 40KSI
Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1506.6, 1507.4.3, 1507.4.4
Panel Dimensions: Panel Width: 16” coverage width
Fastener: #10 X 1” Pancake‐Head wood fasteners or equivalent. Corrosion Resistant per Florida Building Code 2014 Section
1506.7. 3/16” minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
15/32” 4ply CDX plywood, plywood supports at maximum 24’ O.C. Design of plywood and plywood supports are outside the
scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2014.
Design Uplift Pressures: Uplift Design Pressure: with Safety Factor of 2
TABLE A
Max Design Pressure ‐71psf
Field Fastener Spacing 6” from panel ends and 6” o.c.
Fastener Size #10
Quality Assurance: In accordance with FBC 2014 and Rule # 61620‐3: Keystone Certification,
Inc. QUA 1824
Test References:
Architectural Testing Inc (TST 1527) # F8542.01‐450‐44 UL 580‐06
Code Compliance: The product described herein demonstrated compliance with The Florida Building Code (FBC) 2014 Section
1504.3.2. The product evaluation is limited to compliance with the structural wind load requirements of the FBC 2014, as relates
to Rule 61G20‐3.
Minimum Slope Range 2/12 Minimum Slope per Florida Building Code 2014, and in accordance with Manufacturers
recommendations.
Installation: Install per manufacturer’s recommended details in compliance with FBC 2014.
Underlayment: Per Manufacturer’s installation guidelines per Florida Building Code 2014
Roof Panel Fire Classification: No classification.
Shear Diaphragm: values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the
Florida Building Code 2014 for roof cladding wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the applicable erection details to reference in drawings for
correct fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be
Female leg of panel snap fit to the male leg of the adjacent panel.
Page 3 of 4
compliant with Florida Building Code 2014 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
Required wind loads shall be determined per project per FBC 2014 and any rational analysis computation shall be prepared by a
licensed design professional.
Certificate of Independence: James Biagi, P.E. does not have nor will acquire financial interest in any company manufacturing or
distributing products under this evaluation. James Biagi, P.E. is not owned or operated or controlled by any company
manufacturing or distributing product under this report.
PRODUCT EVALUATION REPORT
Page 4 of 4
Value Engineered Metal Roofing ™
FLORIDA PRODUCT APPROVAL
ECONO LINE (26GA CLIPLESS 1.0 NAIL STRIP/SNAP LOCK)
INSTALL DETAILS
Fastener: # 10 Pancake Head Wood Fastener