Loading...
HomeMy WebLinkAboutLakewood Park Pharmacy_ CD5_ permit set_ 3-2-20GSPublisherVersion 0.0.100.100 ...............................................................................F F LOO E RTI DAT ASRTECG EIS TIT HERCER D A AR97108 LAKEWOOD PHARMACYINTERIOR ALTERATIONS5045 Turnpike Feeder Rd, Fort Pierce, FL 34951A-1 codes 3/2/20IDDATECOMMENTFL Design Build InspectConstruction + Architecture+ Home InspectionCRC1331263 | AA26003142 | HI10776772.321.4500frank.liebler@gmail.comwww.FLDesignBulidInspect.com© ALL IDEAS, DESIGNS, PLANS AND ARRANGEMENTS INDICATED ON THIS SHEET ARE THE PROPERTY OF FL DESIGN BUILD INSPECT, AND WERE CREATED, EVOLVED AND DEVELOPED FOR THIS SPECIFIC PROJECT.S H E E T A-1 A-2 GN-1 codes plans general notes CODE SUMMARY Existing Overall Buiding FBC Codes FFPC Codes Occupancy Mercantile FBC 302.1 Mercantile‐C 37 Construction Type 5B FBC 602 N/A N/A Gross Area of Total Bldg 4,000 sf N/A N/A N/A Allowable Height 40' / 1 stories FBC 504 N/A N/A Allowable Area 9,000 sf FBC 506 N/A N/A Sprinklers provided no N/A no N/A Proposed Area of Work Occupancy M FBC 302.1 Mercantile‐C 37.1.2 Min Construction Type 5B FBC 602 N/A N/A Gross Area of Work see calcs N/A N/A N/A Gross Area Added 0 sf N/A N/A N/A Net area see calcs N/A N/A N/A Sprinklers modified or added no N/A N/A N/A Alteration Level 2 FBC EXTG CH.5 N/A N/A Egress Occupant Load 14 FBC 1004 14 7.3 Exit Width req 3 in FBC 1005.1 N/A N/A Exit Width provided 36 in N/A N/A N/A Number of exits req 1 FBC 1006.2 1 37.2.4 Number of exits provided 1 N/A N/A N/A Panic Hardware req no FBC 1010.1.10 N/A N/A Exit Signs req no FBC 1013.1 no 37.2.10 Manual Fire Alarm req no FBC 907.2 no 37.3.4 Max common path of travel 75 FBC 1006.2.1 75 ft 37.2.5.3 Max travel distance 200 ft FBC 1017.2 150 ft 37.2.6 Emergency Lighting req no FBC 1008.3 no 37.2.9 Plumbing Fixtures req WC:  see calcs FBC P 403.1 N/A N/A Lav:  see calcs FBC P 403.1 N/A N/A unisex allowed yes FBC P 403.2 N/A N/A RR Public Access req yes FBC P 403.1 N/A N/A Water Cooler req no FBC P 403.1 N/A N/A Drinking Fountain req no FBC P 403.1 N/A N/A Service Sink req no FBC P 403.1 N/A N/A Fire Resistance structural frame 0.0 hr FBC 601 N/A N/A bearing wall ‐ exterior 0.0 hr FBC 601 N/A N/A bearing wall ‐ interior 0.0 hr FBC 601 N/A N/A non‐bearing wall ‐ exterior 0.0 hr FBC 601 N/A N/A non‐bearing wall ‐ interior 0.0 hr FBC 601 N/A N/A floor construction  0.0 hr FBC 601 N/A N/A roof construction 0.0 hr FBC 601 N/A N/A fire wall 3.0 hr FBC 706.4 N/A N/A Fire Separation separated occupancies N/A FBC 508.4 N/A N/A fire wall N/A FBC 706 N/A N/A fire barrier N/A FBC 707 N/A N/A tenant fire partition 1.0 hr FBC 708 N/A N/A Interior Wall & Clg Finishes Vertical exits and exit passageways n/a FBC 803 N/A N/A Exit access corridors & other exitways CLASS B FBC 803 N/A N/A Rooms and enclosed spaces CLASS C FBC 803 any 37.3.3 Occupancy Calcs area ratio occupants total gross unit 832 sf 60 13.87 13.9 total occupants 14 Plumbing Fixtures Calcs ratio qty male lav 750 0.01 female lav 750 0.01 male wc 500 0.01 female  wc 500 0.01 3-0x5-2 3-0x5-23-0x5-23-6x5-23-6x5-23-6x5-217'-6"10' 30'-3 1/2" 7'-6"10' 1'-6"3'-9"1'-6"2'2'-1"3'-9"3'-2"1'-7 1/2"13'-2"1'-11 1/2"1'-9 1/2"7'-7 1/2"9'3'-1/2"2'-7"4'-4"4'-8"4'-6 1/2"5'-9 1/2"5'-8 1/2"1'-7 1/2" 4'-8" 10' 3'3'-9"7'29'-9 1/2" 11'-4 1/2"5'-9" HAND SK bev coolerREF SHEET INDEX LOCATION KEY DIMENSIONED FLOOR PLAN SCALE: 1/4"= 1'-0" SCOPE OF WORK 1. EXTG TO REMAIN: PERIMETER WALLS, STRUCTURAL SHELL, CEILING, HVAC. 2. NEW NOT SHOWN IN PLAN: FLOOR FINISH unit5045 PROJECT DESCRIPTION INTERIOR ALTERATIONS TO EMPTY GROUND LEVEL UNIT IN A STRIP MALL. ZONING INFORMATION: parcel id: 1301-615-0221-000-0 Comm (unincorporated St Lucie County) flood zone: X UTILITY INFORMATION: gas: n/a sewage: public potable water: public DEFERRED SUBMITTALS: 1. MEP AS NEEDED CODE SUMMARY: GSPublisherVersion 0.0.100.100 ...............................................................................F F LOO E RTI DAT ASRTECG EIS TIT HERCER D A AR97108 LAKEWOOD PHARMACYINTERIOR ALTERATIONS5045 Turnpike Feeder Rd, Fort Pierce, FL 34951A-2 plans 3/2/20IDDATECOMMENTFL Design Build InspectConstruction + Architecture+ Home InspectionCRC1331263 | AA26003142 | HI10776772.321.4500frank.liebler@gmail.comwww.FLDesignBulidInspect.com© ALL IDEAS, DESIGNS, PLANS AND ARRANGEMENTS INDICATED ON THIS SHEET ARE THE PROPERTY OF FL DESIGN BUILD INSPECT, AND WERE CREATED, EVOLVED AND DEVELOPED FOR THIS SPECIFIC PROJECT.S H E E T SCALE: 1"= 1'-0" WIDTH VARIES EXISTING SLAB #3 REBAR 4" EMBED @ 18" oc #3 REBAR 18" OC EW, OMIT IF WWF OR FIBER FINISH TME CONC OVER 6 MIL VB OVER COMPACTED & TERMITE TREATED FILL TYP SLAB INFILL DETAIL (AS NEEDED) 0'-0" 8'-11" 12'-7" P1 DROP CLG: ACT STEEL ROOF DECK CONC SOG P2 P3 STEEL BAR JOIST 3'4'5'4'-6"1'-5"9"3'-7" P1 P3 TYP SILL EL: 56" P2 ALL METERS NEIGHBORING BUSINESS TENANTFRONT COMMON COVERED WALKWAY OTC SHELVESRX SHELVESWORK COUNTER, TYP EL: 36"WAITINGPHARMACY OTC EXTERIORWORK COUNTERHAND SK OTC SHELVESbev cooler DROP OFFPICK UP CONSULTTRAVEL DISTANCE 53'-0"EXITFE FE EXIT ELD1 D2D3D4 E-PANELALARMHC RR REF48'-6 1/2"32'-10" 9'-2 1/2" 5'-9"5'-9" 11' 3'-3" 4'-10 1/2" 15'-4"17'-1 1/2" SK counterALL METERS E-PANELALARMNEIGHBORING MERCANTILE TENANTEXTERIORFRONT COMMON COVERED WALKWAY RR EXITFE EXIT ELHAND SK bev cooler E1 E1E1 E1 E1 E2 E2 E2 E2 E2 E2 E2 E2E2E-SIGNL1 L1 L1 L1L1 L1 L3 L4 L4 L4 EXL S1 S2 L3L3 L3E2 E-REF E-REF E1 REFL1 L4 L3 EL: 8', 1/2" GWB OVER 3-5/8 25GA METAL JOISTS @ 16" OC. EL: 8'-6", 2'x4' ACT L1 L1 L1 L1L1 L1 L3 L4 L4 L4 eRA reSA eSA eSA eSAreSA EXL L3L3 L3 L1 L4 L3 eSA ID SIZE TYPE MATERIAL GLAZING HANDLE HARDWARE RENO STATUS NOTE D1 36" x 96"S. SWING ALUM/GLASS YES PUSH BAR/PULL HANDLE W/ LOCK SELF CLOSING DEVICE EXTG, AS IS ADA THRESHOLD D2 36" x 96"S. SWING SOLID WOOD NO LEVER W/ LOCK NEW DUTCH DOOR D3 36" x 96"S. SWING HOLLOW WOOD NO LEVER W/ PRIVACY LOCK NEW D4 36" x 96"S. SWING STEEL NO LEVER W/ LOCK EXTG, CHANGES DOOR SCHEDULE EL EXIT FE E1 E2 E- L1 L2 L3 L4 S S1 S2 eSA reSA eRA EXL PLAN LEGEND EXTG EMERGENCY LIGHT EXTG EXIT LIGHT PORTABLE FIRE EXTINGUISHER 110V/15A DUPLEX RECEPTACLE- AFF: 14" 110V/15A DUPLEX RECEPTACLE- AFF: ABOVE & BELOW COUNTER ELECTRIC FOR LABLED APPLIANCE EXTG 2x4 FLOURESCENT LIGHT, REPLACE WITH LED EXTG 2x2 FLOURESCENT LIGHT, REPLACE WITH LED NEW 2x2 LED LIGHT NEW 2x4 LED LIGHT LIGHT SWITCH LIGHT SWITCH- AUTO ON/OFF MOTION DETECTOR LIGHT SWITCH- DIMMER & TIMER PER FBC C405.2.2.1 EXTG AC SUPPLY AIR CEILING GRILLE EXTG & RELOCATED AC SUPPLY AIR CEILING GRILLE EXTG AC RETURN AIR CEILING GRILLE EXHAUST FAN & LIGHT- CEILING MOUNT, USE EXTG VENT THRU REAR WALL, 50CFM SCHEMATIC SECTION SCALE: NTS PROPOSED FLOOR / LIFE SAFETY PLAN SCALE: 1/4"= 1'-0" EXISTING FLOOR / LIFE SAFETY PLAN SCALE: 1/4"= 1'-0" PROPOSED SCHEMATIC POWER PLAN SCALE: 1/4"= 1'-0" PROPOSED RCP / SCHEMATIC LIGHTING PLAN SCALE: 1/4"= 1'-0" PARTITIONS P1. TYP EXTG 8" CMU WALL- 1/2" GWB OVER R4.1 FOIL OVER 2x FURRING STRIPS P2. TYP NON FIRE RATED INTERIOR NON LOADBEARING WALLS: 5/8" OR 1/2" GWB OVER 3 5/8" 25 GA METAL STUD @ 16" OC. X-BRACE TOP TRACK TO BAR JOISTS W/ 12 GA WIRE OR 25 GA STUD @ 48" OC. P3. TYP EXTG 1 HR FIRE PARTITION, FV W/ ARCHITECT OR INSPECTOR KEYNOTES 1. FLOOR PLAN NOTES 1. GSPublisherVersion 0.0.100.100 ...............................................................................F F LOO E RTI DAT ASRTECG EIS TIT HERCER D A AR97108 LAKEWOOD PHARMACYINTERIOR ALTERATIONS5045 Turnpike Feeder Rd, Fort Pierce, FL 34951GN-1 general notes 3/2/20IDDATECOMMENTFL Design Build InspectConstruction + Architecture+ Home InspectionCRC1331263 | AA26003142 | HI10776772.321.4500frank.liebler@gmail.comwww.FLDesignBulidInspect.com© ALL IDEAS, DESIGNS, PLANS AND ARRANGEMENTS INDICATED ON THIS SHEET ARE THE PROPERTY OF FL DESIGN BUILD INSPECT, AND WERE CREATED, EVOLVED AND DEVELOPED FOR THIS SPECIFIC PROJECT.S H E E T GENERAL NOTES- commercial 1. CODE COMPLIANCE: 1.1. This project was designed under the following codes. The construction documents cannot reference all of the codes require for the construction of this building. By submitting these construction documents for permit or commencing work, the contractor, hereby agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing codes, including but not limited to, the most current editions as adopted by the state of Florida, of the following: 2017 FBC: BUILDING/ ACCESSIBILITY/ EXISTING/ EXISTING BUILDING 6th ed 2017 FBC: ENERGY CONSERVATION, 6th ed 2017 FBC: PLUMBING/ GAS/ MECHANICAL, 6th ed 2017 FLORIDA FIRE PREVENTION CODE 2014 NATIONAL ELECTRIC CODE 2. ALL GENERAL NOTES 2.1. THE FOLLOWING SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO SUPPLEMENT THE DRAWINGS. IN CASE OF CONFLICT, NOTIFY ARCHITECT. THESE DRAWINGS, IN CONJUNCTION WITH OTHER SUBMITTALS, REPORTS, OR WRITTEN INSTRUCTIONS BY ARCHITECT OR CONSULTANTS, SHALL BE CONSIDERED THE COMPLETE CONSTRUCTION DOCUMENTS. 2.2. THE FOLLOWING GENERAL & SPECIFIC NOTES SHALL APPLY EQUALLY TO ALL CONTRACTORS , SUBCONTRACTORS, AND SUPPLIERS ENGAGED IN EXECUTION OF WORK ON THESE PLANS. 2.3. GENERAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF DRAWINGS AND ADDENDUM'S TO ALL SUBCONTRACTORS ON THE JOB AND COORDINATE THEIR WORK. ANY DISCREPANCIES AND/OR CONFLICTS IN THE DRAWINGS SHALL BE NOTIFIED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY INSTALLATION. FAILURE TO DO SO WILL BE THE ENTIRE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ANY COSTS ARISING TO CORRECT THE DISCREPANCY AND/OR CONFLICT SHALL BE BORNE BY THE RESPONSIBLE PARTY. 2.4. NO DEVIATION OF THE APPROVED SET OF DRAWINGS WILL BE MADE IN THE FIELD WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT AND BUILDING OFFICIAL. IN SUCH CASE THE ARCHITECT SHALL PREPARE A REVISION IN ACCORDANCE WITH THE CHANGE. APPROVAL FROM THE BUILDING OFFICIAL SHALL BE OBTAINED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK. 3. ARCHITECT & CONTRACTOR RELATIONSHIP 3.1. UNLESS CONTRACTED DIRECTLY BY CONTRACTOR, THE ARCHITECT AND CONTRACTOR ARE NOT IN A CONTRACTUAL RELATIONSHIP, THE ARCHITECT IS AN AGENT OF THE OWNER. BY SUBMITTING THESE CONSTRUCTION DOCUMENTS FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THAT THEY ARE COMPETENT, UNDERSTAND THE DOCUMENTS, AND ARE BOUND BY THE TERMS OF THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE ACCEPTING LIABILITY THAT MAY ARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR’S INCOMPETENCY TO UNDERSTAND THE CONSTRUCTION DOCUMENTS. IT IS NOT THE ARCHITECT'S ERROR OR OMISSION IF THE ARCHITECT DOES NOT SPECIFY/REFERENCE SOMETHING THAT IS REQUIRED BY THE CODES MENTIONED, THE CONTRACTOR AND SUBS ARE REQUIRED TO UNDERSTAND AND ADHERE THE BLDG CODES NO DIFFERENT THAN THE ARCHITECT. 4. WORKMANSHIP: 4.1. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES. 5. COORDINATION: 5.1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK FOR ALL TRADES. 5.2. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THAT THE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FAR AS IT AFFECTS THE TRADES. ALL TRADES SHALL INCLUDE EVERYTHING NECESSARY FOR A COMPLETE AND PROPERLY FUNCTIONING CODE - ACCEPTABLE PROJECT, UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT). 6. ABBREVIATIONS: 6.1. SEE ABBREVIATION LIST FOR DEFINITIONS WHICH ARE USED IN THESE DRAWINGS AND SPECIFICATIONS. 7. CONDITIONS NOT DETAILED: 7.1. CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY CONDITION OR INSTRUCT THE CONTRACTOR ON HOW TO PERFORM THE WORK. EVERY CONNECTION, CORNER, FLASHING, ETC. MUST BE RESOLVED. NOTIFY ARCHITECT IF A CONDITION NEEDS ADDITIONAL DIRECTION OR DETAIL. ARCHITECT IS NOT LIABLE FOR WORK THAT IS NOT DETAILED/SPECIFIED BY ARCHITECT. IF DRAWINGS HAVE A DETAILED SPECIFICATION FOR A CERTAIN PRODUCT , CONTRACTOR MAY REQUEST A SUBSTITUTION APPROVAL BY ARCHITECT . IF DRAWINGS HAVE A GENERIC SPECIFICATION CONTRACTOR IS FREE TO USE ANY PRODUCT THAT MEETS WHAT IS SPECIFIED WITHOUT APPROVAL BY ARCHITECT. 8. VERIFY SITE INFORMATION: 8.1. CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AND ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL CONDITIONS. SHOULD ANY CONDITIONS AFFECTING THE WORK BE DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN. 9. PRIOR TO ANY EXCAVATION WORK : 9.1. THE CONTRACTOR IS REQUIRED TO LOCATE ANY AND ALL UTILITIES IN OR UNDER CONSTRUCTION, AND MAKE ARRANGEMENTS FOR THEIR LEGAL RE-ROUTING, AS ACCEPTABLE TO GOVERNING AGENCIES, AUTHORITIES, UTILITIES AND OWNER. CONTACT ALL AFFECTED UTILITY COMPANIES AND INFORM THEM OF THE IMPENDING CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIES. 10. DIMENSIONS: 10.1. DIMENSIONS ON ARCHITECTURAL DRAWINGS MAY BE "ROUGH" OR "FINISH." SEE PLANS FOR REQUIREMENTS. ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENCE OVER STRUCTURAL OR OTHER DIMENSIONS, IF NO OTHER CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPANCIES TO ARCHITECT IN WRITING. DO NOT RELY ON SCALED DIMENSIONS. 11. HEIGHT ELEVATIONS: 11.1. BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAIN FLOOR SLAB AS ELEVATION 0'-0" (BUILDING ELEVATIONS MAY BE NOTED AS "BLDG EL. __" OR "EL. __" OR "AFF. __”) ANY ELEVATION NOT OTHERWISE DESIGNATED AS A SITE ELEVATION IS ON ANY PLANS OTHER THAN THE SITE PLAN IS ASSUMED TO BE A BUILDING ELEVATION. SITE ELEVATIONS MAY BE BASED ON THE SURVEY, WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A REFERENCE DATUM. SITE ELEVATIONS MAY BE NOTED AS: "SEL __" OR "__ NAVD" OR " +X.X' ". CONSULT ARCHITECT FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING. 12. AMBIGUITY: 12.1. IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH REGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT SHALL INTERPRET THE CONSTRUCTION DOCUMENTS. 12.2. IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, CONSULT WITH ARCHITECT . 13. FLORIDA PRODUCT APPROVALS / SUBMITTALS / SHOP DRAWINGS: 13.1. THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTANCE (NOA) / PRODUCT APPROVALS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO MAKE THESE AVAILABLE AT TIME OF INSPECTION. EVEN IF THE ARCHITECT PROVIDES THESE THE CONTRACTOR MAY CHANGE TO A DIFFERENT PRODUCT THAT MEETS THE SAME OR HIGHER BUILDING DESIGN PRESSURES, SOME JURISDICTIONS WILL REQUIRE A REVISION. IF THERE IS A DISCREPANCY BETW THE FASTENING OF PRODUCTS, ACCORDING TO MFR INSTALLATION AND ARCHITECT'S SPECS, VERIFY W/ ARCHITECT. 13.2. SHOP DRAWINGS/SUBMITTALS WILL BE REVIEWED FOR DESIGN CONFORMITY AND GENERAL CONFORMANCE TO CONSTRUCTION DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT JOBSITE FOR TOLERANCE, CLEARANCE, QUANTITIES, FABRICATION PROCESSES /TECHNIQUES OF CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES, AND FULL COMPLIANCE WITH CONSTRUCTION DOCUMENTS. 14. GENERAL STRUCTURAL 14.1. ONCE SIGNED & SEALED BY ARCHITECT OR ENGINEER. DESIGN PROFESSIONAL CERTIFIES THAT THE CONSTRUCTION DOCUMENTS MEET THE LOAD REQUIREMENTS STATED IN THE APPLICABLE FBC REFERENCED. 14.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION. PROVIDE APPROPRIATE SUPERVISION THROUGHOUT THE PROJECT. CONSTRUCTION SITE SAFETY, INCLUDING ALL ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. TEMPORARY BRACING AND SHORING SHALL BE DESIGNED TO RESIST ALL CONSTRUCTION LOADS INCLUDING THE WEIGHTS OF ALL SUPPORTED MATERIALS PLUS A LIVE LOAD OF 50 PSF ON HORIZONTAL SURFACES. MAINTAIN TEMPORARY BRACING AND RETAIN IN PLACE UNTIL PERMANENT STRUCTURAL SYSTEMS ARE CAPABLE OF RESISTING ALL CONSTRUCTION PHASE LOADS. 14.3. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS. 14.4. SPECIFIC PRODUCT DATA MUST BE PROVIDED TO ARCHITECT FOR APPROVAL OF HEAVY FINISHES SUCH AS TILE ROOFS OR STONE ON RAISED FLOORS. 15. CAST-IN-PLACE CONCRETE 15.1. ARCHITECT OR ENGINEER OF RECORD TO BE NOTIFIED IN WRITING PRIOR TO POUR, TO GIVE ARCHITECT THE OPTION TO INSPECT THE REINFORCEMENT FOR OVERHEAD BEAMS AND SLABS 15.2. CONCRETE PROPORTIONING, PLACING, FINISHING AND CURING SHALL BE AS PER THE LATEST EDITION OF THE PCA MANUAL. LEAVE SUPPORT FOR ELEVATED CONCRETE IN PLACE UNTIL THE CONCRETE HAS REACHED ITS DESIGN STRENGTH: -OVERHEAD SLABS AND BEAMS TO BE 4000 PSI CONCRETE MIN UNO -COLUMN AND WALL CONCRETE TO BE 3000 PSI CONCRETE MIN UNO -FOOTINGS AND SLAB-ON-GRADE TO BE 3000 PSI CONCRETE MIN UNO -AUGERGAST PILE TO BE 5000 PSI CONCRETE MIN UNO 15.3. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 6 INCHES MAXIMUM AND 1 INCH MINIMUM EXCEPT FOR SLABS ON-GRADE WHICH SHALL HAVE A MAXIMUM SLUMP OF 5 INCHES AND A MINIMUM OF 3 INCH. 15.4. COMPLY WITH ALL REQUIREMENTS OF ACI 117-10. 15.5. ALL REINFORCING SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL; WELDED WIRE MESH TO ASTM A-185. ARRANGEMENT AND BENDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE ACI DETAILING MANUAL AND THE CONCRETE REINFORCING STEEL INSTITUTE . DON'T SPLICE IN MIDDLE 1/3 OF BEAM OR COLUMN SPAN, IF A SPLICE IN SPAN IS UNAVOIDABLE, FOLLOW DEVELOPMENT LENGTH/LAP DISTANCE IF NOT NOTED VERIFY W/ ARCHITECT 15.6. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC., PRIOR TO PLACING CONCRETE. 15.7. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. START INITIAL CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER PLACING AND FINISHING. KEEP CONTINUOUSLY MOIST FOR NOT LESS THAN 7 DAYS IN ACCORDANCE WITH ACI 301 PROCEDURES. PERFORM CURING OF THE CONCRETE BY CURING AND SEALING COMPOUND, BY MOIST CURING, BY MOISTURE RETAINING COVER CURING OR BY COMBINATION THEREOF. 15.8. SEE THE DRAWINGS FOR CONCRETE COVER FOR REINFORCING STEEL, BUT IN NO CASE SHALL THE COVER BE LESS THAN THAT REQUIRED BY ACI318: -CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH; 3" -CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER, 1 1/2" INCHES; #6 BARS AND LARGER, 2" 15.9. CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND BY KEYED, DOWELED OR SAW-CUT CONTROL JOINTS SUCH THAT THE ENCLOSED AREA DOES NOT EXCEED 260 SQUARE FEET. POST-TENSIONED CONCRETE SLABS ON GRADE SHALL NOT HAVE CONTROL JOINTS UNLESS SPECIFICALLY NOTED ON THE PLANS. EXPANSION JOINT FILLER SHALL BE NON-EXTRUDED PREMOLDED MATERIAL OF ASPHALT IMPREGNATED FIBERBOARD (ASTM D1751) 15.10. CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (BEAMS, COLUMNS, ELEVATED SLABS , ETC.) NOT SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS REQUIRE PRIOR APPROVAL OF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING PROPOSED JOINTS TO ENGINEER FOR APPROVAL. 15.11. ALL CONCRETE SHALL UTILIZE A MINIMUM OF 20% FLY ASH CONTENT . 15.12. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERTICAL REINFORCING BARS AT CORNERS, JAMBS OF OPENINGS, BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. VERTICAL WALL REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. -TIES/STIRRUPS TO START AT A DISTANCE FROM SUPPORT OF 1/2 TIE SPACING 15.13. NO HOLES, CHASES, OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT ARCHITECT'S APPROVAL. 23. PE TRUSSES: 23.1. FIELD VERIFY WITH ARCHITECT EXACT LOCATION AND CONFIGURATION BEFORE MODIFYING EXISTING TRUSSES. DO NOT CUT ANY FRAMING MEMBERS OR TRUSSES WITHOUT EXPRESS WRITTEN AUTHORITY FROM THE ENGINEER AND ARCHITECT. 23.2. FIELD VERIFY DIMENSIONS OF NEW PRE-ENGINEERED TRUSSES PRIOR TO CONSTRUCTING. 23.3. CONTRACTOR TO SUBMIT THE TRUSS ENGINEERING TO ARCHITECT TO REVIEW FOR ADHERENCE WITH DRAWINGS PRIOR TO CONSTRUCTION. ARCHITECT'S SEAL WILL NOT BE APPLIED. 23.4. TRUSS CONFIGURATION DRAWN ARE SCHEMATIC ONLY, HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL LAYOUT MY MFR. EXACT TRUSS WEB, CHORD SIZES AND LAYOUT ARE TO BE DETERMINED BY THE MFR. TRUSS MFR TO DESIGN ANY PERMANENT BRACING REQUIRED FOR STABILITY. 23.5. ALL TRUSSES FURNISHED SHALL BE SUPPLIED WITH SIGNED AND SEALED TRUSS DIAGRAMS PROVIDING THE MFR'S TRUSS SPECIFIC REQUIREMENTS FOR BRACING AND LATERAL MOVEMENT. ALL TRUSS-TO- TRUSS CONNECTORS TO BE SUPPLIED BY THE TRUSS MFR. VERIFY THAT THE CAPACITY OF THE TRUSS ANCHORS CALLED OUT ON THE CONSTRUCTION DRAWINGS MEET OR EXCEED THE UPLIFT VALUES ON THE TRUSS ENGINEERING. ANY TRUSS ANCHORS CALLED OUT THAT ARE OF INSUFFICIENT CAPACITY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR SUBSTITUTION . 23.6. BRACE BOTTOM CHORD AS PER MFR SPECS, IF NOT PROVIDED, PROVIDE CONTINUOUS 'RAT RUN ' LATERAL BRACE PERPENDICULAR TO BC 2x4 @ 12' OC (2) 12d NAILS EA BC. 23.7. PREFABRICATED WOOD TRUSSES , JOISTS, AND GIRDER TRUSSES SHALL BE DESIGNED TO SUPPORT THEIR SELF-WEIGHT, PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. INCLUDING, BUT NOT LIMITED TO, WALLS EITHER PARALLEL OR PERPENDICULAR TO THE SPAN, ALL MECHANICAL AND OTHER EQUIPMENT, AND SHALL DESIGNED TO RESIST ALL DRAG FORCES, SHEARWALL UPLIFT AND DOWNWARD LOADS, AND OTHER SPECIAL LOADS NOTED ON STRUCTURAL, MECHANICAL, PLUMBING, OR ARCHITECTURAL DRAWINGS OR CALCULATIONS. MINIMUM ALLOWABLE SHEAR SHALL BE 95 PSI, BRIDGING SIZE AND SPACING SHALL BE AS DESIGNATED BY TRUSS MFR UNLESS NOTES OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICBO APPROVAL. THE MFR SHALL DESIGN CONNECTION OF TRUSS REQUIRING PREFABRICATED HARDWARE HANGER OR OTHER. 23.8. FABRICATOR TO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER). SPECIALTY ENGINEER MAY SUBMIT PREFERRED CONNECTION AND OTHER DETAILS IF DIFFERENT FROM SAME ON DRAWINGS FOR APPROVAL. 24. CONNECTORS/FASTENERS: 24.1. CONNECTORS BY SIMPSON OR APPROVED SIMILAR TO BE HDG OR ZMAX COATED IF UNEXPOSED TO WEATHER AND TO BE STAINLESS STEEL IF EXPOSED TO WEATHER UPON COMPLETION . 24.2. UPLIFT CONNECTORS MAY BE SUBSTITUTED WITH CONNECTORS WITH ≥ THE DOCUMENTED UPLIFT VALUE IS ≥ SPECIFIED CONNECTOR. UNLESS SPECIFIED UPLIFT CONNECTORS ARE NOT REQUIRED ON LOADBEARING WALLS THAT ARE NOT SUBJECT TO UPLIFT OR SHEAR. SPACE NAILS AT STRAPS AS TO NOT SPLIT WOOD, USE MINIMUM NAIL QTY REQUIRED BY MFR. IF MULTIPLE FASTENER OPTIONS USE EITHER UNLESS SPECIFIED BY ARCHITECT. 25. SITE/LANDSCAPING: 25.1. THE IRRIGATION (IF USED) SYSTEM SHALL BE INSTALLED SUCH THAT NO WATER HITS THE BUILDING DURING OPERATION. 25.2. SLOPE GRADES AWAY FROM BUILDING ON ALL SIDES A MINIMUM OF 6" OVER 10', 4:1 SLOPE MAX. 26. EXTERIOR DOORS AND WINDOWS: 26.1. INSTALL OVERHEAD DOORS (INCLUDING BUCKS), EXTERIOR DOORS, AND WINDOWS AS PER MFR'S SPECIFICATION/ PRODUCT APPROVAL. 26.2. PT 1x BUCK: ATTACH TO MASONRY /CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR 6D CASE HARD NAILS OR T NAILS @ 12"/3" END. ATTACH TO MASONRY /CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR 6D CASE HARD NAILS OR T NAILS @ 12"/4" END. PT 2x BUCK: ATTACH TO MASONRY /CONC W/ADHESIVE & RECESSED 1/4"x3 1/4" MIN TAPCON @ 8"/4" END. 26.3. MIN OVERHEAD DOOR BUCK: 2x6 @ SIDES TO FILLED CELL W/ WEDGE ANCHOR @ 24" OC MIN, 12" FROM ENDS. WEDGE ANCHOR TO BE 1/2" x 6" W/ 2" x 1/8" WASHER. 2x6 @ TOP TO LINTEL W/ 1/4" x 2.75" TAPCONS STAG @ 24" OC. 26.4. CONTRACTOR TO VERIFY THE FOLLOWING WITH MFR/SUPPLIER PRIOR TO CONSTRUCTION: -ROUGH OPENING DIMS, SAFETY GLASS COMPLIANCE (FBC 2406) 26.5. CONTRACTOR TO FIELD VERIFY OPENINGS BEFORE ORDERING DOORS/WINDOWS. 26.6. FLASHING AS PER FBC R703.4 AND REFERENCED FMA/AAMA DOCUMENTS. 26.7. GLASS TO HAVE: LOW-E, U-FACTOR ≤ 0.4, SHGC ≤ 0.25 27. ELECTRICAL & LIGHTING NOTES 27.1. PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF CIRCUITS, RECEPTACLES, FIXTURES, AND EQUIPMENT, SHALL BE DETERMINED BY AN ELECTRICAL CONTRACTOR AND APPROVED BY THE ARCHITECT. IF LAYOUT/SIZING IS PROVIDED ELECTRICAL CONTRACTOR TO VERIFY. 27.2. ALL 120V 15A AND 20A DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT TYPE. 27.3. PROVIDE AFIC AS DETERMINED BY NEC 210.12. 27.4. PROVIDE GFIC AS DETERMINED BY NEC 210.8. 27.5. ALL EXTERIOR OUTLETS TO BE GFIC WITH WEATHER TIGHT PROTECTIVE COVER. 27.6. SMOKE ALARMS SHALL BE HARD WIRED, INTERCONNECTED, W/ BATTERY BACKUP. 27.7. CARBON MONOXIDE ALARM TO BE INTEGRAL WITH SMOKE ALARM. 27.8. WHERE AHU IS IN ATTIC, PROVIDE POWER RECEPTACLE & LIGHT. 28. PLUMBING: 28.1. PLANS ARE SCHEMATIC. ACTUAL LOCATION, MATERIAL, AND SIZE OF PIPES, DRAINS, AND VENTS SHALL BE DETERMINED BY A LICENSED PLUMBER AND APPROVED BY THE ARCHITECT. IF LAYOUT/SIZING IS PROVIDED PLUMBING CONTRACTOR TO VERIFY. 28.2. SEPTIC & DRAIN FIELD IS SCHEMATIC, EXACT LAYOUT/SIZING SHALL BE BY A LICENSED SEPTIC CONTRACTOR AND ADHERE TO 64E-6, F.A.C. 28.3. NO PLUMBING REQUIREMENTS SHALL INTERRUPT THE STRUCTURAL INTEGRITY OF THE BUILDING. 29. ROOF PENETRATIONS: 29.1. VERIFY ALL REQUIRED ROOF PENETRATIONS FROM HVAC, PLUMBING, ELECTRICAL, AND OTHER DRAWINGS. PROVIDE ALL NECESSARY PENETRATIONS WITH REQUIRED ACCESSORIES TO PREVENT MOISTURE INTRUSION AND RETAIN STRUCTURAL STABILITY, IN ADDITION TO THOSE INDICATED ON THE ROOF PLAN. CONSULT ARCHITECT IF ROOF PLAN CONFLICTS WITH ANY REQUIRED ROOF PENETRATIONS. 30. FIRE RATED UL FLOOR, WALL, & ROOF PENETRATIONS: 30.1. CONTRACTOR MUST USE SPECIFIC UNDERWRITER'S LABORATORIES DESIGN NUMBERED SYSTEMS FOR PENETRATING RATED WALLS, FLOORS, AND CEILINGS. ARCHITECT'S DOCUMENTS MAY OR MAY NOT INDICATE CERTAIN SYSTEMS. CONTRACTOR TO FURNISH UL NUMBERS IF APPLICABLE. 30.2. PENETRATIONS AS PER FBC 714 31. EGRESS: 31.1. DOORS AS PER FBC 1010 AND FBC ACCESSIBILITY 404 31.2. STAIRWAY AS PER FBC 1011 31.3. EXIT SIGN AS PER 1013 31.4. GUARDRAILS AS PER FBC 1015 32. FIRE PROTECTION: 32.1. CONTRACTOR SHALL CONSULT WITH THE AHJ/ FIRE MARSHALL REGARDING REQUIREMENTS FOR FIRE EXTINGUISHER. 32.2. IF DRAWINGS SPECIFIES THE USE OF FIRE SPRINKLERS, CONTACTOR TO INSTALL FULLY AUTOMATIC FIRE SPRINKLER SYSTEM. SPRINKLER SYSTEMS SHALL BE DESIGNED BY ENGINEER OR LICENSED FIRE SPRINKLER CONTRACTOR. LOCATION OF HEADS AND DISTRIBUTION LINES SHALL BE COORDINATED AS TO NOT INTERFERE WITH THE LOCATION OF ANY MEP FIXTURE. 32.3. PROVIDE FIRE BLOCKING AS PER FBC 718.2. 32.4. PROVIDE DRAFTSTOPPING AS PER FBC 718.3 & 718.4. 33. MISC: 33.1. ROOF SYSTEM & FLASHING AS PER MFR INSTRUCTIONS. 33.2. EXTERIOR LATH AS PER FBC R703.7.1 AND ASTM C1063-11A AND FBC 2510 33.3. MEP SYSTEMS 1'+ BFE, 33.4. CAULK BOTTOM OF SOLE PLATE AT GARAGE COMMON FRAME WALL. 33.5. IGNITION BARRIER NOT REQUIRED FOR SPRAY FOAM IN ATTIC UNO 33.6. RESTROOM FIXTURES AS PER FBC ACCESSIBILITY CH.6 34. FINISHES: 34.1. GWB: MOISTURE RESISTANT GWB @ ALL WET AREAS, CEMENT BOARD INSIDE SHOWER COMPARTMENTS. USE 5/8” TYPE X GWB ON GARAGE CEILING IF CONDITIONED/HABITABLE AREA ABOVE. GARAGE SEPARATION WALL TO HAVE A MINIMUM OF ONE 1/2" LAYER OF GWB ON THE GARAGE SIDE OF WALL AS PER FBC R302.6. SEE DOOR GEN NOTE 26.6. 34.2. EXTERIOR LATH AS PER FBC R703.7.1/ASTM C1063-11A. FOR EXTERIOR CEILINGS/SOFFITS USE MIN. 5/8" STUCCO ON RIBBED LATH. ATTACH TO BOTTOM OF WOOD FRAMING W/ 11GA NAILS W/ 3/8" HEAD @ 6" OC W/ 1-3/4" EMBED INTO WOOD. 34.3. EXTERIOR T&G WOOD CEILING. ATTACH 1x4 OR 1x6 BOARD W/ 2" 16GA FINISH NAIL EA RAFTER /JOIST/BC. TO CHANGE ORIENTATION USE 2x4 FLAT PURLINS ATTACHED TO EA RAFTER /JOIST/BC W/ (2)16D NAIL. 35. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA: 35.1. WEATHERING: NEGLIGIBLE, TERMITE AREA: VERY HEAVY 16. CONCRETE MASONRY: 16.1. ALL MASONRY UNITS SHALL CONFORM TO THE REQUIREMENTS OF ASTM C90 FOR LOAD BEARING MASONRY. 16.2. MASONRY STRENGTH (f'm DESIGN) UNO: -BLOCK STRENGTH = 1900 -MORTAR STRENGTH = 1800 -GROUT STRENGTH = 2000 16.3. GROUT SHALL HAVE A SLUMP OF 8 TO 11 INCHES, BE IN CONFORMANCE WITH ASTM C 476-02 AND ATTAIN A COMPRESSIVE STRENGTH OF 3000 PSI. GROUT SHALL CONFORM TO REQUIREMENTS OF FLBC STANDARDS. USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT SEGREGATION. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL BE FILLED SOLID WITH GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. HOLD GROUT DOWN 1-1/2" BELOW TOP OF BLOCK AT GROUT LIFT JOINTS AND AT CONCRETE PLACED OVER MASONRY. 16.4. CONCRETE MASONRY UNITS SHALL BE PLUMB, TRUE TO LINE, WITH LEVEL COURSES ACCURATELY SPACED AND BUILT TO THE THICKNESS AND IN A RUNNING BOND AS INDICATED AND CONFORMING TO THE TOLERANCES SPECIFIED IN ACI 531.1 AND 530.1. 16.5. REINFORCING BARS SHALL BE PLACED IN THE MIDDLE OF THE CELLS, UNLESS NOTED OTHERWISE, AND TIED OR OTHERWISE SECURELY SUPPORTED AT THE TOP AND BOTTOM TO ENSURE THAT THE BAR DOES NOT MOVE DURING GROUTING. 16.6. MORTAR DROPPINGS AND OTHER DEBRIS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED. 16.7. CONTROL JOINTS SHALL BE PROVIDED IN ACCORDANCE WITH THE LOCATIONS AND DETAILS SHOWN ON THE DRAWINGS. CONTROL JOINTS SHALL NOT EXTEND THROUGH THE TOP BOND BEAM COURSE. THE JOINTS ON BOTH SIDES OF THE WALL SHALL BE SEALED AND TOOLED SMOOTH. 16.8. WALL REINFORCEMENT : VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SPECIFIED ON THE DRAWINGS. DESPITE IF SHOWN ON DRAWINGS- PLACE VERTICAL REINFORCING BARS AT CORNERS, EA CELL WITHIN 16" OF CORNER, JAMBS OF OPENINGS, EA CELL WITHIN 16" OF JAMBS FOR OPENINGS WIDER THAN 12', BELOW BEAM BEARING, BELOW GIRDER TRUSS BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. IF NOT SPECIFIED IN TEXT ON DRAWINGS USE #5 @ 48” OC. WALL REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. 8" TOLERANCE ALLOWED FOR WALL REINF SPACING. SEE DOWEL NOTE BELOW. 16.9. REINFORCED MASONRY LINTELS SUCH AS CAST CRETE TO BE INSTALLED AS PER MFR INSTRUCTIONS. USE #6 BOTTOM FIELD BAR IN LIEU OF #5 FOR ALL OPENINGS WIDER THAN 12'. LINTELS TO HAVE 4” MINIMUM BEARING. CONTINUOUS REINF ACROSS COLUMNS. IF SPECIFIED, OA LINTEL LENGTH IS +/- AS LONG AS MIN BRG IS MET. DOOR/WINDOW LINTELS CAN BE DEEPER(TALLER) THAN SPECIFIED BUT NOT SHORTER. 16.10. UNO HORIZ JOINT REINFORCEMENT @ 16” OC IN MASONRY WALLS. 16.11. BOND/TIE BEAMS/LINTELS- CONTINUE REINFORCING BARS CONT (UNINTERRUPTED) AROUND ALL CORNERS, OVER OPENINGS, ACROSS WALL INTERSECTIONS, THROUGH TIE COLUMNS, AND UP/DOWN AT CHANGES IN BOND BEAM ELEVATION. 16.12. ALTERNATE WINDOW SILL: 4"H MIN x 8"W CAST CONC W/ (1) # 5 EXTENDED 4" INTO FILLED JAMB CELLS. 17. FOUNDATIONS: 17.1. CONTRACTOR RESPONSIBLE FOR IN-PLACE SOILS TO BE UNIFORMLY COMPACTED TO 95% DENSITY, AND TESTED TO ENSURE MINIMUM SOIL BEARING PRESSURE CAPACITY SPECIFIED IS MET. ALL SITE PREP AS PER GEOTECH SPECS. 17.2. DOWEL VERTICAL REINFORCING BARS OUT OF THE FOUNDATION OR STRUCTURE BELOW WITH BARS OF THE SAME SIZE AND SPACING OF WALL ABOVE. THERE SHALL BE A DOWEL FOR EACH VERTICAL REINFORCING BAR. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. For #5: MINIMUM 30" LAP W/ 10" HOOK UNO. SEE WALL REINFORCEMENT NOTE 16.8 ABOVE. FOR MISSED EMBEDDED DOWEL, EPOXY EMBED W/ 1/8" OVERSIZED HOLE DIA., 6" EMBED W/ CLEAN HOLE. 17.3. BUILDING SLABS-ON-GRADE TO BE REINFORCED WITH 6x6 10/10 WWF MIN WITH MESH UP CHAIRS OVER 6- MIL MINIMUM POLYETHYLENE FILM VAPOR RETARDER OVER TERMITE TREATED COMPACTED GRADE UNO. PROVIDE DIAGONAL 36" #4 REBAR AT ALL INSIDE 'REENTRANT' CORNERS. 17.4. CONTINUOUS FOOTINGS, STEM OR MONOLITHIC, TO BE REINFORCED CONTINUOUS, WITH LAPS AS PER STATED DEVELOPMENT LENGTH IF NOTED OR 48x BAR DIAMETER MIN UNO. 30" MIN CORNERS BARS TO MATCH LONGITUDINAL REBAR. 17.5. PROVIDE A 4-INCH MEDIUM TO COARSE SAND OR GRAVEL COMPACTED DRAINAGE FILL BELOW ALL INTERIOR SLABS-ON-GRADE UNLESS NOTED OR DETAILED OTHERWISE. 17.6. SOIL AND SUBGRADE IS TO BE TERMITE TREATED. 17.7. SLAB FINISHES UNO: -MAIN BUILDING: STEEL TROWEL FINISH -GARAGE: STEEL TROWEL, THRESHOLD: LIGHT BROOM -DRIVEWAY, DRIVEWAY APRON , PORCHES/PATIOS: LIGHT BROOM 17.8. GARAGE, AND ALL EXTERIOR HARD SURFACES TO SLOPE AWAY FROM BLDG MIN 1/8"/FT. 17.9. CONCRETE PADS FOR VIBRATING EQUIPMENT SUCH AS PUMPS OR MOTORS TO BE SEPARATED FROM HOUSE SLAB WITH A MINIMUM OF AN ASPHALT EXPANSION JOINT. 17.10. RECESS SGD & GARAGE DOOR THRESHOLDS 3/4"- VERIFY EXACT DIMENSIONS WITH SUPPLIER/MFR. 17.11. COLUMN/WALL AND FOOTING CENTERLINES SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 18. STRUCTURAL STEEL: 18.1. ALL STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A-36 AND THE "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. ALL STEEL PIPE SHALL CONFORM TO ASTM A-53, TYPE E (Fy = 35 KSI). 18.2. ALL SHOP CONNECTIONS TO BE WELDED AND FIELD CONNECTIONS TO BE BOLTED UNLESS OTHERWISE SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF "THE STANDARD CODE FOR WELDING IN BUILDING CONSTRUCTION" OF THE AMERICAN WELDING SOCIETY. 18.3. ALL STEEL TO RECEIVE ONE SHOP COAT AND ONE FIELD TOUCHUP COAT OF APPROVED PAINT. 18.4. ALL BOLTED CONNECTIONS SHALL CONSIST OF ASTM A325 HIGH STRENGTH BOLTS AND HARDENED WASHERS AS SHOWN ON THE STRUCTURAL DRAWINGS. ALL BOLTED CONNECTIONS SHALL CONFORM TO THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. 18.5. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A36 OR A307 (THREADED ROD). 18.6. SUBMIT SHOP DRAWINGS FOR REVIEW OF CONFORMANCE TO DESIGN CONCEPT. 18.7. GROUT FOR COLUMN BASE PLATES SHALL BE NON-SHRINK GROUT 5000 PSI MINIMUM. 19. LIGHT GAGE METAL STUDS & MISC. METAL FRAMING : 19.1. ALL LIGHT GAGE METAL INTERIOR STUDS SHALL BE G90 GALVANIZED 25 GA MINIMUM. USE 20 GA STUDS WHERE HEAVY LOADS ARE HUNG FROM SUCH AS TV'S OR WALL CABINETS . ALL WALL TRACKS SHALL BE 25 GA. 20. HVAC: 20.1. PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF UNITS, DUCTS, RETURN AIR GRILLES AND SUPPLY GRILLES ETC, SHALL BE DETERMINED BY A HVAC LICENSED CONTRACTOR AND APPROVED BY THE ARCHITECT. IF LAYOUT/SIZING IS PROVIDED HVAC CONTRACTOR TO VERIFY. 20.2. PROVIDE MANUFACTURED CONCRETE PAD AND BRACKETS RATED FOR SPECIFIED WIND LOAD FOR CONDENSING UNIT. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE MANUFACTURER'S SPECIFICATIONS. 21. WOOD FRAMING 21.1. ALL STRUCTURAL (LOAD BEARING) LUMBER SHALL BE S.Y.P. OR DOUGLASS FIR, GRADE #2, KD 19% (Fb FOR LUMBER SIZES NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND THE SOUTHERN FOREST PRODUCTS ASSOCIATION. ALL NON-LOAD BEARING FRAMING LUMBER (INTERIOR WALLS) TO BE #2 S.P.F. OR BETTER. 21.2. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL WOOD EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO 0.80 CCA. 21.3. SPLICING FOR MULTI-PLY HEADERS /BEAMS/COLUMNS: -2x4- 10d COMMON NAIL @ 6" OC EACH LAYER STAGGERED. -2x6- 2 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x8- 3 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x10- 4 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x12- 5 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -LOCATE SPLICES OVER BRG SUPPORTS. GLUE BETW LAYERS. USE 16D IF 1/2" PLY SPACER USED 21.4. LAMINATED TIMBER ELEMENTS (BENTS, BEAMS, DECK, ETC., AND ANCILLARY ACCESSORIES, FASTENERS, ETC.: -FABRICATOR TO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER ) -SPECIALTY ENGINEER MAY SUBMIT CONNECTION DETAILS FOR BENTS AND BEAMS AND FASTENING MODE AND INTERVALS FOR DECK. (CONNECTIONS FOR BEAM-ENDS TO RESIST ROTATION.) 21.5. GLUE-LAMINATED BEAMS (GLULAM) SHALL BE DOUGLAS FIR COMBINATION 24F-V4 AT SIMPLE SPANS AND 24F-V8 AT CANTILEVER SPANS HAVING THE FOLLOWING MINIMUM PROPERTIES: Fb = 2,400 PSI, Fv = 190 PSI, Fc (PERPENDICULAR) = 650 PSI, E = 1,800,000 PSI, FABRICATION AND HANDLING SHALL CONFORM TO THE LATEST AMERICAN INSTITUTE FOR TIMBER CONSTRUCTION (AITC) AND ASTM STANDARDS. BEAMS SHALL BEAR AN APPROPRIATE GRADE STAMP CLEARLY NOTING ITS DESIGN PROPERTIES. UNLESS CAMBER AND TOLERANCE IS SPECIFICALLY NOTED ON THE DRAWINGS, BEAMS SHALL BE MANUFACTURED WITH INDUSTRY STANDARD MINIMUM CAMBER OR UPWARD TO SPAN/200. ERECT WITH CROWN OR CAMBER UP. IN HEADER CONDITIONS (BEAM BUILT INTO WALL) CRIPPLE FRAMING ABOVE HEADER SHALL MAINTAIN CAMBER. HEADER BEAMS MAY HAVE ZERO CAMBER, PROVIDED CRIPPLE FRAMING ABOVE HEADER IS BUILT WITH MINIMUM CAMBER STATED ABOVE. 21.6. LAMINATED LUMBER AND "I" JOISTS AND RAFTERS SHALL BE INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS. 21.7. END STUDS OF EXTERIOR FRAME WALL OR DESIGNATED INTERIOR SHEAR WALLS TO ATTACH TO CONC WALL W/ .25” x 3.25” TAPCON @ 16” OC. 21.8. ALL WOOD NAILING AS PER FBC R 602.3 UNO. 22. PLYWOOD SHEATHING: 22.1. ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS. 22.2. UPPER PANELS TO BE ATTACHED TO THE TOP MEMBER OF THE UPPER DOUBLE TOP PLATE AND TO RIM JOIST AT BOTTOM OF WALL. PROVIDE BLOCKING FOR ALL EDGE NAILING OVER LENGTH OF PLYWOOD 22.3. FOR EXTERIOR AND INTERIOR SHEAR WALLS USE 1/2" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF CORNERS. 22.4. FOR ROOF USE 5/8" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF EAVES/RIDGES/GABLES. 22.5. FOR SUBFLOOR USE 3/4" PLYWOOD AND 2.5" #8 SCREWS & GLUE OR 8d RINGSHANK GALV NAILS & GLUE. SPACE FASTENERS 6" FIELD, 6" EDGE. 22.6. FOR ATTIC FLOOR USE 5/8" PLYWOOD AND 6d RINGSHANK GALV NAILS. SPACE NAILS 12" FIELD, 12" EDGE. ONLY ALLOWED WHERE TRUSS ENGINEERING SPECIFIES. ABBREVIATIONS: AB ANCHOR BOLT A/C AIR CONDITIONER AHU AIR HANDLING UNIT AT ACOUSTICAL TILE B.M. BENCH MARK BM BEAM BC BOTTOM CHORD BO BY OWNER BOTT BOTTOM BP BOTTOM PLATE CJ CONTROL (CONSTRUCTION) JOINT CL CENTER LINE CLG CEILING CMU CONCRETE MASONRY UNIT CO CONNECTOR COL COLUMN CONC CONCRETE CONT CONTINUOUS CU CONDENSING UNIT OR COPPER CW COLD WATER CXN CONNECTION D NAIL SIZE (PENNY) DR DRYER DISP DISPOSAL DF DRINKING FOUNTAIN DTL DETAIL DW DRIVEWAY 'E' EXISTING EA EACH EJ EXPANSION JOINT EL BUILDING ELEVATION ELECT ELECTRICAL EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXP EXPOSED EXT EXTERIOR EXTG EXISTING F1 FOOTING #1 FA FASTENER FD FIELD (FLOOR) DRAIN FE FIRE EXTINGUISHER FF FINISH FLOOR FIN FINISH FLR FLOOR FP FIRE PROTECTION EPS EXPANDED POLYSTYRENE FTG FOOTING FT FOOT (OR FEET) GFI GROUND FAULT INDICATOR GSF GROSS SQUARE FEET GWH GAS WATER HEATER GWB GYPSUM WALL BOARD HB HOSE BIB HDG HOT DIPPED GALVANIZED HW HOT WATER HWH HOT WATER HEATER IN INCH INT INTERIOR JT JOINT MAX MAXIMUM MFR MANUFACTURER MIN MINIMUM MW MICROWAVE NIC NOT IN CONTRACT NTS NOT TO SCALE NSF NET SQUARE FEET L-1 LINTEL #1 LF LINEAL FOOT OC ON CENTER OAS OR APPROVED SIMILAR PL PROPERTY LINE OR PLATE PLY PLYWOOD PT PRESSURE TREATED PVC POLY VINYL CHLORIDE R RADIUS R/A RETURN AIR RCB REINFORCED CONCRETE BEAM RCC REINFORCED CONCRETE COLUMN RD ROOF DRAIN REF REFRIGERATOR REINF REINFORCING REQ REQUIRED R/W RIGHT-OF-WAY RTU ROOF TOP UNIT S. SIMPSON (MFR) SBS STYRENE BUTADIENE STYRENE SEL SITE ELEVATION SF SQUARE FOOT SK SINK SOG SLAB ON GRADE SS STAINLESS STEEL STAG STAGGERED TBD TO BE DETERMINED TC TOP CHORD TME TO MATCH EXISTING TOB TOP OF BEAM TOB TOP OF COLUMN TOS TOP OF SLAB TP TOP PLATE TPO THERMO PLASTIC OLEFIN TYP TYPICAL UG UNDER GROUND UNO UNLESS NOTED OTHERWISE VB VAPOR BARRIER VTR VENT THRU ROOF WA WASHER MACHINE WP WATER PROOF WD WOOD WWF WELDED WIRE FABRICMESH